Wrist block has been used to provide pain relief
for many procedures on the hand and wrist but its role in arthroscopy
of the wrist remains unexplored. Chondrotoxicity has been a concern
with the intra-articular infiltration of local anaesthetic. We aimed
to evaluate and compare the analgesic effect of portal and wrist
joint infiltration with a wrist block on the pain experienced by
patients after arthroscopy of the wrist. A prospective, randomised, double-blind trial was designed and
patients undergoing arthroscopy of the wrist under general anaesthesia
as a day case were recruited for the study. Levo-bupivacaine was
used for both techniques. The effects were evaluated using a ten-point
visual analogue scale, and the use of analgesic agents was also
compared. The primary outcomes for statistical analyses were the
mean pain scores and the use of analgesia post-operatively. A total of 34 patients (63% females) were recruited to the portal
and joint infiltration group and 32 patients (59% males) to the
wrist block group. Mean age was 40.8 years in the first group and
39.7 years in the second group (p >
0.05). Both techniques provided
effective pain relief in the first hour and 24 hours post-operatively
but wrist block gave better pain scores at bedtime on the day of
surgery (p = 0.007) and at 24 hours post-operatively (p = 0.006). Wrist block provides better and more reliable analgesia in patients
undergoing arthroscopy of the wrist without exposing patients to
the risk of chondrotoxicity. Cite this article:
In this paper, we critically appraise the recent
publication of the United Kingdom Heel Fracture Trial, which concluded
that when patients with an absolute indication for surgery were
excluded, there was no advantage of surgical over non-surgical treatment
in the management of calcaneal fractures. We believe that selection bias in that study did not permit the
authors to reach a firm conclusion that surgery was not justified
for most intra-articular calcaneal fractures. Cite this article:
This article presents an overview of mycetoma
and offers guidelines for orthopaedic surgeons who may be involved in
the care of patients with this condition. Cite this article:
The June 2015 Research Roundup360 looks at: Tranexamic acid: just give it – it’s not important how!; The anterolateral ligament re-examined; Warfarin a poor post-operative agent; Passive exoskeleton the orthosis of the future?; Musculoskeletal medicine: a dark art to UK medical students?; Alendronic acid and bone density post arthroplasty; Apples with oranges? Knee functional scores revisited
The August 2013 Children’s orthopaedics Roundup360 looks at: a multilevel approach to equinus gait; whether screening leads to needless intervention; salvage of subcapital slipped epiphysis; growing prostheses for children’s oncology; flexible nailing revisited; ultrasound and the pink pulseless hand; and slipping forearm fractures.
Epidemiological studies enhance clinical practice
in a number of ways. However, there are many methodological difficulties
that need to be addressed in designing a study aimed at the collection
and analysis of data concerning fractures and other injuries. Most
can be managed and errors minimised if careful attention is given
to the design and implementation of the research. Cite this article:
The December 2013 Trauma Roundup360 looks at: Re-operation for intertrochanteric hip fractures; Are twin incisions better than one round the acetabulum?; Salvage osteotomy for calcaneal fractures; Posterior dislocation; Should MRSA be covered in open fractures?; Characterising the saline load test; Has it healed: hip fractures under the spotlight; and stem cells present in atrophic non-union.
The development of tibiofemoral angle in children has shown ethnic
variations. However this data is unavailable for our population. We measured the tibiofemoral angle (TFA) and intercondylar and
intermalleolar distances in 360 children aged between two and 18
years, dividing them into six interrupted age group intervals: two
to three years; five to six years; eight to nine years; 11 to 12
years; 14 to 15Â years; and 17 to 18 years. Each age group comprised
30 boys and 30 girls. Other variables recorded included standing
height, sitting height, weight, thigh length, leg length and length
of the lower limb.Objectives
Methods
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
Mechanical alignment has been a fundamental tenet of total knee arthroplasty (TKA) since modern knee replacement surgery was developed in the 1970s. The objective of mechanical alignment was to infer the greatest biomechanical advantage to the implant to prevent early loosening and failure. Over the last 40 years a great deal of innovation in TKA technology has been focusing on how to more accurately achieve mechanical alignment. Recently the concept of mechanical alignment has been challenged, and other alignment philosophies are being explored with the intention of trying to improve patient outcomes following TKA. This article examines the evolution of the mechanical alignment concept and whether there are any viable alternatives.
Clinicians are often asked by patients, “When
can I drive again?” after lower limb injury or surgery. This question
is difficult to answer in the absence of any guidelines. This review
aims to collate the currently available evidence and discuss the
factors that influence the decision to allow a patient to return
to driving. There is currently insufficient evidence for any authoritative
body to determine fitness to drive. The lack of guidance could result
in patients being withheld from driving for longer than is necessary,
or returning to driving while still unsafe. Cite this article:
Rebound growth after hemiepiphysiodesis may be
a normal event, but little is known about its causes, incidence
or factors related to its intensity. The aim of this study was to
evaluate rebound growth under controlled experimental conditions. A total of 22 six-week-old rabbits underwent a medial proximal
tibial hemiepiphysiodesis using a two-hole plate and screws. Temporal
growth plate arrest was maintained for three weeks, and animals
were killed at intervals ranging between three days and three weeks
after removal of the device. The radiological angulation of the proximal
tibia was studied at weekly intervals during and after hemiepiphysiodesis.
A histological study of the retrieved proximal physis of the tibia
was performed. The mean angulation achieved at three weeks was 34.7° (standard
deviation ( In our rabbit model, rebound was an event of variable incidence
and intensity and, when present, did not appear immediately after
restoration of growth, but took some time to appear. Cite this article:
The April 2015 Research Roundup360 looks at: MCID in grip strength and distal radial fracture; Experiencing rehab in a trial setting; Electrical stimulation and nerve recovery; Molecular diagnosis of TB?; Acetabular orientation: component and arthritis; Analgesia after knee arthroplasty; Bisphosphonate-associated femoral fractures
In distal fibular resection without reconstruction,
the stabilising effect of the lateral malleolus is lost. Thus, the ankle
may collapse into valgus and may be unstable in varus. Here, we
describe a child who underwent successful staged surgical correction
of a severe neglected valgus deformity after excision of the distal
fibula for a Ewing’s sarcoma.
We report the kinematic and early clinical results
of a patient- and observer-blinded randomised controlled trial in which
CT scans were used to compare potential impingement-free range of
movement (ROM) and acetabular component cover between patients treated
with either the navigated ‘femur-first’ total hip arthroplasty (THA) method
(n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional
THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75).
The Hip Osteoarthritis Outcome Score, the Harris hip score, the
Euro-Qol-5D and the Mancuso THA patient expectations score were
assessed at six weeks, six months and one year after surgery. A
total of 48 of the patients (84%) in the navigated ‘femur-first’
group and 43 (65%) in the conventional group reached all the desirable
potential ROM boundaries without prosthetic impingement for activities
of daily living (ADL) in flexion, extension, abduction, adduction
and rotation (p = 0.016). Acetabular component cover and surface
contact with the host bone were >
87% in both groups. There was
a significant difference between the navigated and the conventional
groups’ Harris hip scores six weeks after surgery (p = 0.010). There
were no significant differences with respect to any clinical outcome
at six months and one year of follow-up. The navigated ‘femur-first’
technique improves the potential ROM for ADL without prosthetic
impingement, although there was no observed clinical difference
between the two treatment groups. Cite this article:
Deep vein thrombosis is a common complication
of immobilising the lower limb after surgery. We hypothesised that
intermittent pneumatic compression (IPC) therapy in outpatients
who had undergone surgical repair of acute ruptures of the Achilles
tendon could reduce the incidence of this problem. A total of 150 patients who had undergone surgical repair of
the Achilles tendon were randomised to either treatment with IPC
for six hours per day (n = 74) under an orthosis or treatment as
usual (n = 74) in a plaster cast without IPC. At two weeks post-operatively,
the incidence of deep vein thrombosis was assessed using blinded, double-reported
compression duplex ultrasound. At this point, IPC was discontinued
and all patients were immobilised in an orthosis for a further four
weeks. At six weeks post-operatively, a second compression duplex ultrasound
scan was performed. At two weeks, the incidence of deep vein thrombosis was 21% in
the treated group and 37% in the control group (p = 0.042). Age
over 39 years was found to be a strong risk factor for deep vein
thrombosis (odds ratio (OR) = 4.84, 95% confidence interval (CI)
2.14 to 10.96). Treatment with IPC, corrected for age differences
between groups, reduced the risk of deep vein thrombosis at the
two-week point (OR = 2.60; 95% CI 1.15 to 5.91; p =0.022). At six weeks,
the incidence of deep vein thrombosis was 52% in the treated group
and 48% in the control group (OR 0.94, 95% CI 0.49 to 1.83). IPC
appears to be an effective method of reducing the risk of deep vein
thrombosis in the early stages of post-operative immobilisation
of outpatients. Further research is necessary to elucidate whether
it can confer similar benefits over longer periods of immobilisation
and in a more heterogeneous group of patients. Cite this article:
The April 2015 Shoulder &
Elbow Roundup360 looks at: Distal clavicular resection not indicated in cuff repair?; Platelet-rich plasma in rotator cuff repair; Radial head geometry: time to change?; Heterotopic ossification in elbow trauma; Another look at heterotopic ossification in the humerus; Triceps on for total elbow arthroplasty?; Predicting outcomes in rotator cuff repair; Deltoid fatty infiltration and reverse shoulder arthroplasty
The aim of this study was to compare the maximum
laxity conferred by the cruciate-retaining (CR) and posterior-stabilised
(PS) Triathlon single-radius total knee arthroplasty (TKA) for anterior
drawer, varus–valgus opening and rotation in eight cadaver knees
through a defined arc of flexion (0º to 110º). The null hypothesis
was that the limits of laxity of CR- and PS-TKAs are not significantly
different. The investigation was undertaken in eight loaded cadaver knees
undergoing subjective stress testing using a measurement rig. Firstly
the native knee was tested prior to preparation for CR-TKA and subsequently
for PS-TKA implantation. Surgical navigation was used to track maximal
displacements/rotations at 0º, 30º, 60º, 90º and 110° of flexion.
Mixed-effects modelling was used to define the behaviour of the
TKAs. The laxity measured for the CR- and PS-TKAs revealed no statistically
significant differences over the studied flexion arc for the two
versions of TKA. Compared with the native knee both TKAs exhibited
slightly increased anterior drawer and decreased varus-valgus and
internal-external roational laxities. We believe further study is required
to define the clinical states for which the additional constraint
offered by a PS-TKA implant may be beneficial. Cite this article:
Lengthening osteotomies of the calcaneus in children are in general
grafted with bone from the iliac crest. Artificial bone grafts have
been introduced, however, their structural and clinical durability
has not been documented. Radiostereometric analysis (RSA) is a very
accurate and precise method for measurements of rigid body movements including
the evaluation of joint implant and fracture stability, however,
RSA has not previously been used in clinical studies of calcaneal
osteotomies. We assessed the precision of RSA as a measurement tool
in a lateral calcaneal lengthening osteotomy (LCLO). LCLO was performed in six fixed adult cadaver feet. Tantalum
markers were inserted on each side of the osteotomy and in the cuboideum.
Lengthening was done with a plexiglas wedge. A total of 24 radiological
double examinations were obtained. Two feet were excluded due to
loose and poorly dispersed markers. Precision was assessed as systematic
bias and 95% repeatability limits.Objectives
Methods
Cartilage repair in terms of replacement, or
regeneration of damaged or diseased articular cartilage with functional tissue,
is the ‘holy grail’ of joint surgery. A wide spectrum of strategies
for cartilage repair currently exists and several of these techniques
have been reported to be associated with successful clinical outcomes
for appropriately selected indications. However, based on respective
advantages, disadvantages, and limitations, no single strategy, or
even combination of strategies, provides surgeons with viable options
for attaining successful long-term outcomes in the majority of patients.
As such, development of novel techniques and optimisation of current techniques
need to be, and are, the focus of a great deal of research from
the basic science level to clinical trials. Translational research
that bridges scientific discoveries to clinical application involves
the use of animal models in order to assess safety and efficacy
for regulatory approval for human use. This review article provides
an overview of animal models for cartilage repair. Cite this article: