Advertisement for orthosearch.org.uk
Results 1021 - 1040 of 1052
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 449 - 454
1 Apr 2006
Hart AJ Hester T Sinclair K Powell JJ Goodship AE Pele L Fersht NL Skinner J

We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologically well-fixed and the patients were asymptomatic. Cobalt and chromium levels were significantly elevated in the patients with metal-on-metal hip resurfacings, compared with the patients with standard metal-on-polyethylene designs (p < 0.0001). There was a statistically significant decrease in the level of CD8+ cells (T-cytotoxic/suppressor) (p = 0.005) in the metal-on-metal hip resurfacing group. A threshold level of blood cobalt and chromium ions was associated with reduced CD8+ T-cell counts. We have no evidence that our patients suffered as a result of this reduced level of CD8+ T-cells.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1050 - 1054
1 Aug 2005
Shetty AA Slack R Tindall A James KD Rand C

We describe the survival of 134 consecutive JRI Furlong hydroxyapatite-coated uncemented total hip replacements. The mean follow-up was for 14.2 years (13 to 15).

Patients were assessed clinically, using the Merle d’Aubigné and Postel score. Radiographs were evaluated using Gruen zones for the stem and DeLee and Charnley zones for the cup. Signs of subsidence, radiolucent lines, endosteal bone formation (spot welds) and pedestal formation were used to assess fixation and stability of the stem according to Engh’s criteria. Cup angle, migration and radiolucency were used to assess loosening of the cup. The criteria for failure were revision, or impending revision because of pain or loosening. Survival analysis was performed using a life table and the Kaplan-Meier curve.

The mean total Merle d’Aubigné and Postel score was 7.4 pre-operatively and 15.9 at follow-up. During the study period 22 patients died and six were lost to follow-up. None of the cups was revised. One stem was revised for a periprosthetic fracture following a fall but none was revised for loosening, giving a 99% survival at 13 years. Our findings suggest that the long-term results of these hydroxyapatite-coated prostheses are more than satisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 65 - 68
1 Jan 2006
Orendurff MS Rohr ES Sangeorzan BJ Weaver K Czerniecki JM

Patients with diabetes mellitus may develop plantar flexion contractures (equinus) which may increase forefoot pressure during walking. In order to determine the relationship between equinus and forefoot pressure, we measured forefoot pressure during walking in 27 adult diabetics with a mean age of 66.3 years (sd 7.4) and a mean duration of the condition of 13.4 years (sd 12.6) using an Emed mat. Maximum dorsiflexion of the ankle was determined using a custom device which an examiner used to apply a dorsiflexing torque of 10 Nm (sd 1) for five seconds.

Simple linear regression showed that the relationship between equinus and peak forefoot pressure was significant (p < 0.0471), but that only a small portion of the variance was accounted for (R2 = 0.149). This indicates that equinus has only a limited role in causing high forefoot pressure. Our findings suggest caution in undertaking of tendon-lengthening procedures to reduce peak forefoot plantar pressures in diabetic subjects until clearer indications are established.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 100 - 106
1 Jan 2007
Nunn TR Cheung WY Rollinson PD

Between September 2004 and December 2005 we carried out a prospective study of all cases of sepsis of the hip in childhood at a South African regional hospital with a large local population, and which also took referrals from nine rural hospitals. The clinical, radiological, ultrasound and bacteriological features were assessed. All the hips were drained by arthrotomy and the diagnosis was confirmed microbiologically and histologically. Hips with tuberculosis were excluded. The children were reviewed in a dedicated clinic at a mean follow-up of 8.1 months (3 to 18).

There were 40 hips with sepsis in 38 patients. Two patients were lost to follow-up. Nine (24%) had multi-focal sepsis. Overall, 13 hips (34%) had a full and uncomplicated clinical and radiological recovery and 25 (66%) had complications. All patients treated by arthrotomy and appropriate antibiotics within five days of the onset of symptoms had an uncomplicated recovery. Initial misdiagnosis was associated with a delay to arthrotomy. However, ‘deprivation’, consultation with a traditional healer, maternal educational attainment and distance to a primary health-care facility were not associated with delay to arthrotomy. The early correct diagnosis of this condition, common in the developing world, remains a significant factor in improving the clinical outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1406 - 1410
1 Oct 2005
Ramachandran M Lau K Jones DHA

In five children, six forearms with a fixed pronation deformity secondary to congenital radioulnar synostosis were treated by a derotation osteotomy of the distal radius and the midshaft of the ulna.

There were three boys and two girls with a mean age of 4.9 years (3.5 to 8.25) who were followed up for a mean of 29 months (18 to 43). The position of the forearm was improved from a mean pronation deformity of 68° (40° to 80°) to a pre-planned position of 10° of supination in all cases. Bony union was achieved by 6.3 weeks with no loss of correction. There was one major complication involving a distal radial osteotomy which required exploration for a possible compartment syndrome.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 503 - 509
1 Apr 2007
Giannoudis PV Tzioupis C Moed BR

Our aim was to evaluate the efficacy of a two-level reconstruction technique using subchondral miniscrews for the stabilisation of comminuted posterior-wall marginal acetabular fragments before applying lag screws and a buttress plate to the main overlying posterior fragment. Between 1995 and 2003, 29 consecutive patients with acute comminuted displaced posterior-wall fractures of the acetabulum were treated operatively using this technique.

The quality of reduction measured from three standard plain radiographs was graded as anatomical in all 29 hips. The clinical outcome at a mean follow-up of 35 months (24 to 90) was considered to be excellent in five patients (17%), very good in 16 (55%), good in six (21%) and poor in two (7%). The use of the two-level reconstruction technique appears to provide stable fixation and is associated with favourable results in terms of the incidence of post-traumatic osteoarthritis and the clinical outcome. However, poor results may occur in patients over the age of 55 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1634 - 1641
1 Dec 2006
Stulik J Stehlik J Rysavy M Wozniak A

We describe the results of 287 intra-articular fractures of the calcaneum in 247 patients treated by minimally-invasive reduction and K-wire fixation between 1994 and 2003. There were 210 men (85%) and 37 women (15%). The most common cause of injury was a fall from a height in 237 patients (96%). Fracture classification was based on the method described by Sanders and Essex-Lopresti. All patients were operated on within 21 days of injury and 89% (220) within 48 hours. The reduction was graded as nearly anatomical (less than 2 mm residual articular displacement and satisfactory overall alignment) in 212 (73.9%) fractures.

There were 20 cases (7%) of superficial pin-track infection and five (1.7%) of deep infection. All healed at a mean of 6 weeks (3 to 19). Loss of reduction was observed in 13 fractures (4.5%) and a musculocutaneous flap was needed in three (1%).

The results were evaluated in 176 patients (205 fractures) with a mean age of 44.3 years (13 to 67), available for follow-up at a mean of 43.4 months (25 to 87) using the Creighton-Nebraska Health Foundation Assessment score. The mean score was 83.9 points (63 to 100). There were 29 (16.5%) excellent, 98 (55.7%) good, 26 (14.8%) fair and 23 (13%) poor results. A total of 130 patients (73.9%) were able to return to their original occupation at a mean of 5.6 months (3.2 to 12.5) after the injury.

Semi-open reduction and percutaneous fixation is an effective treatment for displaced intra-articular fractures of the calcaneum.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices.

We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively.

The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02.

The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1492 - 1496
1 Nov 2006
Gordon GS Simkiss DE

We reviewed the evidence for hip surveillance in children with cerebral palsy from the published literature.

Publications were identified using the Cochrane controlled trials register, the MEDLINE, EMBASE and CINAHL databases and by hand searching key journals and their references. Studies were included if they reported the frequency, associated risk factors or surveillance measures undertaken to identify subluxation or dislocation of the hip in children with cerebral palsy. Assessment of the quality of the methodology was undertaken independently by two researchers.

Four studies described the natural history, incidence and risk factors for dislocation of the hip. Two reported their surveillance results. Approximately 60% of children who were not walking by five years of age were likely to develop subluxation of the hip, with the greatest risk in those with severe neurological involvement. The introduction of surveillance programmes allowed earlier identification of subluxation and reduced the need for surgery on dislocated hips.

Surveillance can identify children most at risk of subluxation using radiological methods which are widely available.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1380 - 1384
1 Oct 2005
Leung YL Buxton N

A combination of hemivertebrae and diastematomyelia is rare. We have identified 12 such patients seen during a period of 11 years in the orthopaedic, spinal and neurosurgical units in Nottingham and analysed their treatment and outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 43 - 49
1 Jan 2008
Smith AJ Wood DJ Li M

We have examined the differences in clinical outcome of total knee replacement (TKR) with and without patellar resurfacing in a prospective, randomised study of 181 osteoarthritic knees in 142 patients using the Profix total knee system which has a femoral component with features considered to be anatomical and a domed patellar implant.

The procedures were carried out between February 1998 and November 2002. A total of 159 TKRs in 142 patients were available for review at a mean of four years (3 to 7). The patients and the clinical evaluator were blinded in this prospective study. Evaluation was undertaken annually by an independent observer using the knee pain scale and the Knee Society clinical rating system. Specific evaluation of anterior knee pain, stair-climbing and rising from a seated to a standing position was also undertaken.

No benefit was shown of TKR with patellar resurfacing over that without resurfacing with respect to any of the measured outcomes. In 22 of 73 knees (30.1%) with and 18 of 86 knees (20.9%) without patellar resurfacing there was some degree of anterior knee pain (p = 0.183). No revisions related to the patellofemoral joint were performed in either group. Only one TKR in each group underwent a re-operation related to the patellofemoral joint. A significant association between knee flexion contracture and anterior knee pain was observed in those knees with patellar resurfacing (p = 0.006).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 198 - 202
1 Feb 2006
Kalairajah Y Cossey AJ Verrall GM Ludbrook G Spriggins AJ

We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial embolisation in computer-assisted navigated total knee arthroplasty (n = 14) and compared this with a standard conventional surgical technique using intramedullary alignment guides (n = 10). All patients were selected randomly without the knowledge of the patient, anaesthetists (before the onset of the procedure) and ward staff. The operations were performed by a single surgeon at one hospital using a uniform surgical approach, instrumentation, technique and release sequence. The only variable in the two groups of patients was the use of single tracker pins of the imageless navigation system in the tibia and femur of the navigated group and intramedullary femoral and tibial alignment jigs in the non-navigated group.

Acetabular Doppler signals were obtained in 14 patients in the computer-assisted group and nine (90%) in the conventional group, in whom high-intensity signals were detected in seven computer-assisted patients (50%) and in all of the non-navigated patients.

In the computer-assisted group no patient had more than two detectable emboli, with a mean of 0.64 (SD 0.74). In the non-navigated group the number of emboli ranged from one to 43 and six patients had more than two detectable emboli, with a mean of 10.7 (sd 13.5). The difference between the two groups was highly significant using the Wilcoxon non-parametric test (p = 0.0003).

Our findings show that computer-assisted total knee arthroplasty, when compared with conventional jig-based surgery, significantly reduces systemic emboli as detected by transcranial Doppler ultrasonography.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 472 - 476
1 Apr 2006
Savarino L Greco M Cenni E Cavasinni L Rotini R Baldini N Giunti A

Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed.

Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured.

There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 740 - 746
1 Jun 2006
Marulanda G Seyler TM Sheikh NH Mont MA

Osteonecrosis of the knee comprises two separate disorders, primary spontaneous osteonecrosis which is often a self-limiting condition and secondary osteonecrosis which is associated with risk factors and a poor prognosis. In a series of 61 knees (38 patients) we analysed secondary osteonecrosis of the knee treated by a new technique using multiple small percutaneous 3 mm drillings.

Total knee replacement was avoided in 59 knees (97%) at a mean follow-up of 3 years (2 to 4). Of the 61 knees, 56 (92%) had a successful clinical outcome, defined as a Knee Society score greater than 80 points. The procedure was successful in all 24 knees with small lesions compared with 32 of 37 knees (86%) with large lesions. All the procedures were performed as day cases and there were no complications. This technique appears to have a low morbidity, relieves symptoms and delays more invasive surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 455 - 459
1 Apr 2006
Shetty NR Hamer AJ Kerry RM Stockley I Eastell R Wilkinson JM

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery.

The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years.

Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1099 - 1109
1 Aug 2007
Munirah S Samsudin OC Chen HC Salmah SHS Aminuddin BS Ruszymah BHI

Ovine articular chondrocytes were isolated from cartilage biopsy and culture expanded in vitro. Approximately 30 million cells per ml of cultured chondrocytes were incorporated with autologous plasma-derived fibrin to form a three-dimensional construct. Full-thickness punch hole defects were created in the lateral and medial femoral condyles. The defects were implanted with either an autologous ‘chondrocyte-fibrin’ construct (ACFC), autologous chondrocytes (ACI) or fibrin blanks (AF) as controls. Animals were killed after 12 weeks. The gross appearance of the treated defects was inspected and photographed. The repaired tissues were studied histologically and by scanning electron microscopy analysis.

All defects were assessed using the International Cartilage Repair Society (ICRS) classification. Those treated with ACFC, ACI and AF exhibited median scores which correspond to a nearly-normal appearance. On the basis of the modified O’Driscoll histological scoring scale, ACFC implantation significantly enhanced cartilage repair compared to ACI and AF. Using scanning electron microscopy, ACFC and ACI showed characteristic organisation of chondrocytes and matrices, which were relatively similar to the surrounding adjacent cartilage.

Implantation of ACFC resulted in superior hyaline-like cartilage regeneration when compared with ACI. If this result is applicable to humans, a better outcome would be obtained than by using conventional ACI.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 893 - 899
1 Jul 2006
Petrou G Chardouvelis C Kouzoupis A Dermon A Petrou H Tilkeridis C Gavras M

We carried out a prospective study of 71 patients who had undergone reconstruction of the anterior cruciate ligament with the ABC scaffold. Their mean age was 28 years (18 to 50). All had either sub-acute or chronic traumatic deficiency of the ligament. The mean period of follow-up was five years (four to seven). Assessment included the use of the International Knee Documentation Committee score, the modified Lysholm score, the Tegner Activity score, the Knee Injury and Osteoarthritis Outcome score and measurement with the KT-1000 arthrometer. Two patients had mild recurrent synovitis. There were no infections and no failures of the ligament. During the period of study, two patients sustained a traumatic fracture of a femoral condyle. The implants retained their integrity in both cases. All patients returned to their previous or enhanced levels of daily activity by three months after operation and 56 (79%) achieved their pre-injury level of sporting activity by six months. The patients who were competing in National level sports returned to play at one level less after operation than before. The Lysholm score showed that 58% of the patients (41) were excellent, 34% (24) good, and 8% (6) fair, with a mean post-operative score of 93. According to the International Knee Documentation Committee score, 35% of knees (25) were ‘normal’, 52% (37) ‘nearly normal’ and 13% (9) ‘abnormal’. Complete satisfaction was noted in 90% of patients (64). The development of osteoarthritis and the management of anterior cruciate deficiency associated with laxity of the medial collateral ligament remains uncertain. Our results indicate that in the medium-term, the ABC ligament scaffold is suitable and effective when early and safe return to unrestricted activities is demanded. We acknowledge the current general hostility towards reconstruction of the anterior cruciate ligament with artificial materials following reports of early failure and chronic synovitis associatiated with the production of particulate debris. We did not encounter these problems.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1605 - 1610
1 Dec 2005
Rathur HM Boulton AJM


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 49 - 53
1 Jan 2006
Tsumara N Yoshiya S Chin T Shiba R Kohso K Doita M

We undertook a prospective, randomised study in order to evaluate the efficacy of clamping the drains after intra-articular injection of saline with 1:500 000 adrenaline compared with post-operative blood salvage in reducing blood loss in 212 total knee arthroplasties. The mean post-operative drained blood volume after drain clamping was 352.1 ml compared to 662.3 ml after blood salvage (p < 0.0001). Allogenic blood transfusion was needed in one patient in the drain group and for three in the blood salvage group. Drain clamping with intra-articular injection of saline with adrenaline is more effective than post-operative autologous blood transfusion in reducing blood loss during total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 790 - 795
1 Jun 2005
Eren A Ömeroglu H Güven M Ugutmen E Altintas F

We treated 26 hips (24 consecutive patients) with residual dysplasia by a technique of incomplete triple pelvic osteotomy. The mean age of the patients was 21.6 years.

The mean values for the pre-operative centre-edge angle of Wiberg, the refined centre-edge angle, the acetabular angle of Sharp, the modified acetabular angle and femoral head lateralisation were 7.7°, −3.1°, 49.3°, 53.2° and 17.2 mm, respectively. After a mean follow-up of 3.3 years they were 27.0°, 13.0°, 38.9°, 44.3° and 15.9 mm, respectively (p < 0.05). The osteoarthritic grading changed adversely in one hip. The mean pre-operative and latest Harris hip scores were 74.9 and 93.0, respectively (p < 0.05).

This technique provides a stable osteotomy with maintenance of the posterior column which allows early mobilisation and minimal internal fixation. The technique is not complex and requires minimal blood transfusion. The use of an image intensifier is not necessary and harvesting of a subcristal bone graft avoids post-operative complications at the donor site.