We have compared the sonographic findings of six femoral fractures with soft-tissue interposition which required open reduction with those of a control group of 40 other femoral fractures. Ultrasound assessment before operation showed that the fractured end of the proximal fragment had penetrated the quadriceps muscle anteriorly while the distal fragment lay beneath it. Transverse scans showed less soft-tissue thickness over the end of the proximal fragment in the problem cases. Radiographic image intensification did not provide any additional information. Ultrasound is of value in demonstrating soft-tissue interposition at the fracture site before femoral
1. The risk of injury to the sciatic nerve during closed ischio-femoral arthrodesis by
We describe the use of Ender
1. The results of treatment of 100 consecutive patients with pertrochanteric and basal fractures of the femur treated by early operative fixation with a McKee two-piece
A prospective study of 141 patients with 143 tibial shaft fractures has been carried out; 102 fractures were closed and 41 open. All the patients were treated by Ender's
We report 33 cases of femoral supracondylar fracture in elderly or debilitated patients treated by Zickel supracondylar
Internal lengthening devices in the femur lengthen
along the anatomical axis, potentially creating lateral shift of
the mechanical axis. We aimed to determine whether femoral lengthening
along the anatomical axis has an inadvertent effect on lower limb
alignment. Isolated femoral lengthening using the Intramedullary
Skeletal Kinetic Distractor was performed in 27 femora in 24 patients
(mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment
procedures or concurrent tibial lengthening, or who developed mal-
or nonunion, were excluded. Pre-operative and six-month post-operative
radiographs were used to measure lower limb alignment. The mean lengthening
achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical
axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0
to 3.5). In one femur that was initially in varus, a 3 mm medial
shift occurred during a lengthening of 2.2 cm. In a normally aligned limb, intramedullary lengthening along
the anatomical axis of the femur results in a lateral shift of the
mechanical axis by approximately 1 mm for each 1Â cm of lengthening.
We identified 25 children (10 girls and 15 boys) who had been treated with single bone intramedullary fixation for diaphyseal fractures of both forearm bones. Their mean age was 10.75 years (4.6 to 15.9). All had a good functional outcome. We conclude that in selected children, single bone intramedullary nailing is a suitable method of treatment for diaphyseal fractures of both bones of the forearm.