The diagnosis of periprosthetic joint infection (PJI) is difficult and requires a battery of tests and clinical findings. The purpose of this review is to summarize all current evidence for common and new serum biomarkers utilized in the diagnosis of PJI. We searched two literature databases, using terms that encompass all hip and knee arthroplasty procedures, as well as PJI and statistical terms reflecting diagnostic parameters. The findings are summarized as a narrative review.Objectives
Methods
To evaluate the effectiveness of an institutionally developed
algorithm for evaluation and diagnosis of prosthetic joint injection
and to determine the impact of this protocol on overall hospital
re-admissions.p We retrospectively evaluated 2685 total hip arthroplasty (THA)
and total knee arthroplasty (TKA) patients prior to (1263) and following
(1422) the introduction of an infection detection protocol. The
protocol used conservative thresholds for C-reactive protein to
direct the medical attendant to aspirate the joint. The protocol
incorporated a clear set of laboratory and clinical criteria that
allowed a patient to be discharged home if all were met. Patients were
included if they presented to our emergency department within 120
days post-operatively with concerns for swelling, pain or infection
and were excluded if they had an unambiguous infection or if their
chief complaint was non-orthopaedic in nature.Aims
Patients and Methods
A clicky hip is a common referral for clinical and sonographic
screening for developmental dysplasia of the hip (DDH). There is
controversy regarding whether it represents a true risk factor for
pathological DDH. Therefore a 20-year prospective, longitudinal,
observational study was undertaken to assess the relationship between
the presence of a neonatal clicky hip and pathological DDH. A total of 362 infants from 1997 to 2016 were referred with clicky
hips to our ‘one-stop’ paediatric hip screening clinic. Hips were
assessed clinically for instability and by ultrasound imaging using
a simplified Graf/Harcke classification. Dislocated or dislocatable
hips were classified as Graf Type IV hips.Aims
Patients and Methods
In the United Kingdom, lower incidences of intraspinal abnormalities
in patients with early onset idiopathic scoliosis have been observed
than in studies in other countries. We aimed to determine the rates
of these abnormalities in United Kingdom patients diagnosed with idiopathic
scoliosis before the age of 11 years. This retrospective study of patients attending an urban scoliosis
clinic identified 71 patients satisfying a criteria of: clinical
diagnosis of idiopathic scoliosis; age of onset ten years and 11 months
or less; MRI screening for intraspinal abnormalities. United Kingdom
census data combined with patient referral data was used to calculate
incidence.Aims
Patients and Methods
Osteoporosis is a chronic disease. The aim of this study was to identify key genes in osteoporosis. Microarray data sets GSE56815 and GSE56814, comprising 67 osteoporosis blood samples and 62 control blood samples, were obtained from the Gene Expression Omnibus database. Differentially expressed genes (DEGs) were identified in osteoporosis using Limma package (3.2.1) and Meta-MA packages. Gene Ontology and Kyoto Encyclopedia of Genes and Genomes enrichment analyses were performed to identify biological functions. Furthermore, the transcriptional regulatory network was established between the top 20 DEGs and transcriptional factors using the UCSC ENCODE Genome Browser. Receiver operating characteristic (ROC) analysis was applied to investigate the diagnostic value of several DEGs.Objectives
Methods
This review summarises the technique of impaction
grafting with mesh augmentation for the treatment of uncontained
acetabular defects in revision hip arthroplasty. The ideal acetabular revision should restore bone stock, use
a small socket in the near-anatomic position, and provide durable
fixation. Impaction bone grafting, which has been in use for over
40 years, offers the ability to achieve these goals in uncontained
defects. The precepts of modern, revision impaction grafting are
that the segmental or cavitary defects must be supported with a
mesh; the contained cavity is filled with vigorously impacted morselised
fresh-frozen allograft; and finally, acrylic cement is used to stabilise
the graft and provide rigid, long-lasting fixation of the revised
acetabular component. Favourable results have been published with this technique. While
having its limitations, it is a viable option to address large acetabular
defects in revision arthroplasty. Cite this article:
To evaluate the effect of a single early high-dose vitamin D
supplement on fracture union in patients with hypovitaminosis D
and a long bone fracture. Between July 2011 and August 2013, 113 adults with a long bone
fracture were enrolled in a prospective randomised double-blind
placebo-controlled trial. Their serum vitamin D levels were measured
and a total of 100 patients were found to be vitamin D deficient
(<
20 ng/ml) or insufficient (<
30 ng/mL). These were then
randomised to receive a single dose of vitamin D3 orally
(100 000 IU) within two weeks of injury (treatment group, n = 50)
or a placebo (control group, n = 50). We recorded patient demographics,
fracture location and treatment, vitamin D level, time to fracture
union and complications, including vitamin D toxicity. Outcomes included union, nonunion or complication requiring an
early, unplanned secondary procedure. Patients without an outcome
at 15 months and no scheduled follow-up were considered lost to
follow-up. The Aims
Patients and Methods
Our aim in this study was to describe a continuing review of
11 total hip arthroplasties using 22.225 mm Alumina ceramic femoral
heads on a Charnley flanged femoral component, articulating against
a silane crosslinked polyethylene. Nine patients (11 THAs) were reviewed at a mean of 27.5 years
(26 to 28) post-operatively. Outcome was assessed using the d’Aubigne
and Postel, and Charnley scores and penetration was recorded on
radiographs. In addition, the oxidation of a 29-year-old shelf-aged
acetabular component was analysed.Aims
Patients and Methods
Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods
Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm3, 0.16 g/cm3 and 0.24 g/cm3). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°.Objectives
Methods
Accurate placement of the acetabular component during total hip
arthroplasty (THA) is an important factor in the success of the
procedure. However, the reported accuracy varies greatly and is
dependent upon whether free hand or navigated techniques are used.
The aim of this study was to assess the accuracy of an instrument
system that incorporates 3D printed, patient-specific guides designed
to optimise the placement of the acetabular component. A total of 100 consecutive patients were prospectively enrolled
and the accuracy of placement of the acetabular component was measured
using post-operative CT scans.Aims
Patients and Methods
Fracture clinics are often characterised by the referral of large
numbers of unselected patients with minor injuries not requiring
investigation or intervention, long waiting times and recurrent
unnecessary reviews. Our experience had been of an unsustainable
system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order
to rationalise and regulate access to our fracture service. The
British Orthopaedic Association’s guidelines have required a prospective evaluation
of this change of practice, and we report our experience and results. We review the management of all 12 069 patients referred to our
service in the calendar year 2014, with a minimum of one year follow-up
during the calendar year 2015. Aims
Patients and Methods