The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 535 - 541
1 Apr 2018
Stevenson JD Doxey R Abudu A Parry M Evans S Peart F Jeys L

Aims

Preserving growth following limb-salvage surgery of the upper limb in children remains a challenge. Vascularized autografts may provide rapid biological incorporation with the potential for growth and longevity. In this study, we aimed to describe the outcomes following proximal humeral reconstruction with a vascularized fibular epiphyseal transfer in children with a primary sarcoma of bone. We also aimed to quantify the hypertrophy of the graft and the annual growth, and to determine the functional outcomes of the neoglenofibular joint.

Patients and Methods

We retrospectively analyzed 11 patients who underwent this procedure for a primary bone tumour of the proximal humerus between 2004 and 2015. Six had Ewing’s sarcoma and five had osteosarcoma. Their mean age at the time of surgery was five years (two to eight). The mean follow-up was 5.2 years (1 to 12.2).


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 785 - 790
1 Sep 1998
Sugimoto K Samoto N Takaoka T Takakura Y Tamai S

We treated 43 acute tears of the calcaneofibular ligament by operation in 43 patients after subtalar arthrography. There were 22 men and 21 women with a mean age of 22.3 years (14 to 61). Anteroposterior (AP), lateral and oblique views were obtained with the foot in 45° of internal rotation and the ankle in the neutral position. Any communication or leakage to the ankle, tendon sheaths, subcutaneous tissue and sinus tarsi was recorded. We examined an oblique view of the microrecess along the interosseous ligament and an AP view of the lateral recess just under the distal end of the fibula. We also studied a control group of 27 patients with isolated injuries of the anterior talofibular ligament without rupture of the calcaneofibular ligament. The findings in the two groups were significantly different when examined for leakage to the ankle (p = 0.0002), to the peroneal tendon sheaths (p = 0.0347) and to the subcutaneous tissue (p = 0.0222), absence of the microrecess (p = 0.0055) and presence of the lateral recess (p = 0.0012). Many ankle sprains which involve tearing of the calcaneofibular ligament are accompanied by injuries of the subtalar joint. Combined injuries of the anterior talofibular ligament and calcaneofibular ligament, and isolated injury of the anterior talofibular ligament should be differentiated


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 4 | Pages 545 - 566
1 Nov 1952
Coltart WD

1. Although fractures and dislocations of the talus have been described since 1608 the rarity of the more severe and complicated injuries has meant a dearth of accurate descriptions or classification in the literature. 2. A series of 228 injuries of the talus occurring in members of the Royal Air Force between 1940 and 1943 has been reviewed. 3. A simple but comprehensive classification of injuries of the talus is presented, together with a review of the pathological anatomy, clinical features, and methods of treatment. The importance of distinguishing between fractures and fracture-dislocations, and of watching carefully for displacements of the subtalar joint, is emphasised. 4. The important complications—infection, avascular necrosis and traumatic arthritis of the ankle or subtalar joint—are discussed. Infection may be the result of a compound injury, or may follow sloughing of the skin stretched over a displaced talus. Early reduction is, therefore, of great urgency in closed injuries. Avascular necrosis of the talus occurs in gross injuries when all or most of the soft-tissue attachments to the bone are severed. Revascularisation and regeneration will take place with patient conservative treatment. 5. The mechanism of injury is discussed. 6. The results of excision of the talus are poor. Every effort should be made to preserve the body of the talus, but if its loss is inevitable a useful foot can be regained by deliberate fusion of the tibia to the calcaneum


Bone & Joint Research
Vol. 7, Issue 10 | Pages 570 - 579
1 Oct 2018
Kallala R Harris WE Ibrahim M Dipane M McPherson E

Aims

Calcium sulphate has traditionally been used as a filler of dead space arising during surgery. Various complications have been described following the use of Stimulan bio-absorbable calcium sulphate beads. This study is a prospective observational study to assess the safety profile of these beads when used in revision arthroplasty, comparing the complication rates with those reported in the literature.

Methods

A total of 755 patients who underwent 456 revision total knee arthroplasties (TKA) and 299 revision total hip arthroplasties (THA), with a mean follow-up of 35 months (0 to 78) were included in the study.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims

The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria.

Patients and Methods

Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1148 - 1156
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this study was to determine the stability of a new short femoral stem compared with a conventional femoral stem in patients undergoing cementless total hip arthroplasty (THA), in a prospective randomized controlled trial using radiostereometric analysis (RSA).

Patients and Methods

A total of 53 patients were randomized to receive cementless THA with either a short femoral stem (MiniHip, 26 patients, mean age: 52 years, nine male) or a conventional length femoral stem (MetaFix, 23 patients, mean age: 53 years, 11 male). All patients received the same cementless acetabular component. Two-year follow-up was available on 38 patients. Stability was assessed through migration and dynamically inducible micromotion. Radiographs for RSA were taken postoperatively and at three, six, 12, 18, and 24 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1065 - 1071
1 Sep 2000
Martini F Lebherz C Mayer F Leichtle U Kremling E Sell S

Our aim was to determine the precision of the measurements of bone mineral density (BMD) by dual-energy x-ray absorptiometry in the proximal femur before and after implantation of an uncemented implant, with particular regard to the significance of retro- and prospective studies. We examined 60 patients to determine the difference in preoperative BMD between osteoarthritic and healthy hips. The results showed a preoperative BMD of the affected hip which was lower by a mean of 4% and by a maximum of 9% compared with the opposite side. In addition, measurements were made in the operated hip before and at ten days after operation to determine the effect of the implantation of an uncemented custom-made femoral stem. The mean increase in the BMD was 8% and the maximum was 24%. Previous retrospective studies have reported a marked loss of BMD on the operated side. The precision of double measurements using a special foot jig showed a modified coefficient of variation of 0.6% for the non-operated side in 15 patients and of 0.6% for the operated femur in 20 patients. The effect of rotation on the precision of the measurements after implantation of an uncemented femoral stem was determined in ten explanted femora and for the operated side in ten patients at 10° rotation and in 20 patients at 30° rotation. Rotation within 30° influenced the precision in studies in vivo and in vitro by a mean of 3% and in single cases in up to 60%. Precise prediction of the degree of loss of BMD is thus only possible in prospective cross-sectional measurements, since the effect of the difference in preoperative BMD, as well as the apparent increase in BMD after implantation of an uncemented stem, is not known from retrospective studies. The DEXA method is a reliable procedure for determining periprosthetic BMD when positioning and rotation are strictly controlled


Bone & Joint 360
Vol. 7, Issue 4 | Pages 3 - 8
1 Aug 2018
White TO Carter TH


Bone & Joint Research
Vol. 7, Issue 8 | Pages 501 - 507
1 Aug 2018
Phan C Nguyen D Lee KM Koo S

Objectives

The objective of this study was to quantify the relative movement between the articular surfaces in the tibiotalar and subtalar joints during normal walking in asymptomatic individuals.

Methods

3D movement data of the ankle joint complex were acquired from 18 subjects using a biplanar fluoroscopic system and 3D-to-2D registration of bone models obtained from CT images. Surface relative velocity vectors (SRVVs) of the articular surfaces of the tibiotalar and subtalar joints were calculated. The relative movement of the articulating surfaces was quantified as the mean relative speed (RS) and synchronization index (SIENT) of the SRVVs.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1533 - 1536
1 Nov 2017
Nie K Rymaruk S Paton RW

Aims

A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH.

Patients and Methods

A total of 362 infants from 1997 to 2016 were referred with clicky hips to our ‘one-stop’ paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 975 - 978
1 Nov 1997
Bar-On E Sagiv S Porat S

We report the outcome of 19 children aged 5.2 to 13.2 years with 20 fractures of the femoral shaft requiring surgery, who were randomly assigned to have external fixation (EF) or flexible intramedullary nailing (FIN) (10 fractures each). The duration of the operation averaged 56 minutes for the EF group with 1.4 minutes of fluoroscopy, compared with 74 minutes and 2.6 minutes, respectively, for the FIN group. The early postoperative course was similar, but the EF group showed much more callus formation. The time to full weight-bearing, full range of movement and return to school were all shorter in the FIN group. The FIN complications included one transitory foot drop and two cases of bursitis at an insertion site. In the EF group there was one refracture, one rotatory malunion requiring remanipulation and two pin-track infections. At an average follow-up of 14 months two patients in the EF group had mild pain, four had quadriceps wasting, one had leg-length discrepancy of over 1 cm, four had malalignment of over 5°, and one had limited hip rotation. In the FIN group, one patient had mild pain and one had quadriceps wasting; there were no length discrepancies, malalignment or limitation of movement. Parents of the FIN group were more satisfied. We recommend the use of flexible intramedullary nailing for fractures of the femoral shaft which require surgery, and reserve external fixation for open or severely comminuted fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 849 - 854
1 Aug 2001
Trnka H Easley ME Lam PW Anderson CD Schon LC Myerson MS

This retrospective study analyses the results of subtalar bone block distraction arthrodesis used in the treatment of late complications of calcaneal fractures, acute severely comminuted fractures, nonunion (and malunion) of attempted subtalar arthrodeses, avascular necrosis of the talus, and club-foot deformity. Of 39 patients (41 feet) who had this procedure, 35 (37 feet) returned for follow-up after a mean of 70 months (26 to 140). There were 24 men (25 feet) and 11 women (12 feet) with a mean age of 41 years (16 to 63). Each completed a standardised questionnaire, based on the hindfoot-scoring system of the American Orthopaedic Foot and Ankle Society and were reviewed both clinically and radiologically. Of the 37 operations, 32 (87%) achieved union. The mean hindfoot score (maximum of 94 points) increased from 21.1 points (8 to 46) preoperatively to 68.9 (14 to 82) at the final follow-up. The mean talocalcaneal and calcaneal pitch angles were 20.5° and 4.9° before operation, 25.9° and 8.3° immediately after, and 24.6° and 7.7° at the final follow-up, respectively. The mean talar declination angle improved from 6.5° (−10 to 22) before operation to 24.8° (14 to 32) at the final follow-up. The mean talocalcaneal height increased from 68.7 mm before operation to 74.5 mm immediately after and 73.5 mm at the final follow-up. Of the 37 arthrodeses available for review, 32 were successful; 29 patients (30 arthrodeses) were satisfied with the procedure. Minimal loss of hindfoot alignment occurred when comparing radiographs taken immediately after operation and at final follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 525 - 533
1 Jul 1994
Boeree N Clarke N

We report the preliminary results of a continuing prospective evaluation of a screening programme for congenital dislocation of the hip (CDH) which uses ultrasound imaging to provide delayed selective screening to complement neonatal clinical screening. Of 26,952 births in the Southampton district, 1894 infants were referred for secondary screening because of a clinical abnormality or the presence of a predetermined risk category for CDH. Pavlik harness treatment was required for only 118 infants, giving a treatment rate of 4.4 per 1000 births. Of those referred with clinical instability, 35% did not require treatment. Dislocation or subluxation was detected in 17 of 643 infants referred only because they fell within one of three risk categories: breech presentation, foot deformity and family history. All 17 had normal clinical examinations and cases were discovered in each category. Six children presented with CDH after 12 weeks of age, giving a late presentation rate of 0.22 per 1000 births. All had normal clinical examinations within 24 hours of birth and none was in a risk category. Surgery has been required in ten children, giving a surgical treatment rate of 0.37 per 1000 births. We conclude that, in Southampton, delayed selective secondary screening with ultrasound is more effective than clinical screening alone. It targets treatment to those infants who need it, and reveals a number of dislocated and subluxed hips that would otherwise be missed


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 170 - 175
1 Feb 2018
Lam Tin Cheung K Lanting BA McCalden RW Yuan X MacDonald SJ Naudie DD Teeter MG

Aims

The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA).

Patients and Methods

A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation).


Bone & Joint 360
Vol. 6, Issue 5 | Pages 27 - 30
1 Oct 2017


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1125 - 1132
1 Aug 2018
Shohat N Foltz C Restrepo C Goswami K Tan T Parvizi J

Aims

The aim of this study was to examine the association between postoperative glycaemic variability and adverse outcomes following orthopaedic surgery.

Patients and Methods

This retrospective study analyzed data on 12 978 patients (1361 with two operations) who underwent orthopaedic surgery at a single institution between 2001 and 2017. Patients with a minimum of either two postoperative measurements of blood glucose levels per day, or more than three measurements overall, were included in the study. Glycaemic variability was assessed using a coefficient of variation (CV). The length of stay (LOS), in-hospital complications, and 90-day readmission and mortality rates were examined. Data were analyzed with linear and generalized linear mixed models for linear and binary outcomes, adjusting for various covariates.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1016 - 1020
1 Sep 2004
Schneider W Aigner N Pinggera O Knahr K

The Chevron osteotomy was described in 1976. There have, however, been only short- to mid-term follow-up reviews, often with small numbers of patients. We looked at 112 feet (73 patients) with a minimum follow-up of ten years following Chevron osteotomy with a distal soft-tissue procedure. Clinical evaluation was calculated using the hallux score of the American Orthopedic Foot and Ankle Society (AOFAS). For 47 feet (30 patients), the results were compared with those from an interim follow-up of 5.6 years. The AOFAS-score improved from a pre-operative mean of 46.5 points to a mean of 88.8 points after a mean of 12.7 years. The first metatarsophalangeal (MTP) angle showed a mean pre-operative value of 27.6° and was improved to 14.0°. The first intermetatarsal (IM) angle improved from a pre-operative mean value of 13.8° to 8.7°. The mean pre-operative grade of sesamoid subluxation was 1.7 on a scale from 0 to 3 and improved to 1.2. Measured on a scale from 0 to 3, arthritis of the first MTP joint progressed from a mean of 0.8 to 1.7. Comparing the results in patients younger and older than 50 years, the Chevron osteotomy performed equally in both age groups. Analysing the subgroup of 47 feet with a post-operative follow-up of both 5.6 and 12.7 years, the AOFAS pain and the overall score showed a further improvement between both follow-up evaluations. The MTP angle, first IM angle and sesamoid position remained unchanged. The progression of arthritis of the first MTP joint between 5.6 and 12.7 years post-operatively was statistically significant. Only one patient required a revision procedure due to painful recurrence of the deformity. Excellent clinical results following Chevron osteotomy not only proved to be consistent, but showed further improvement over a longer follow-up period. The mean radiographic angles were constant without recurrence of the deformity. So far, the statistically significant progression of first MTP joint arthritis has not affected the clinical result, but this needs further observation


Bone & Joint Research
Vol. 6, Issue 6 | Pages 376 - 384
1 Jun 2017
Stentz-Olesen K Nielsen ET De Raedt S Jørgensen PB Sørensen OG Kaptein BL Andersen MS Stilling M

Objectives

Static radiostereometric analysis (RSA) using implanted markers is considered the most accurate system for the evaluation of prosthesis migration. By using CT bone models instead of markers, combined with a dynamic RSA system, a non-invasive measurement of joint movement is enabled. This method is more accurate than current 3D skin marker-based tracking systems. The purpose of this study was to evaluate the accuracy of the CT model method for measuring knee joint kinematics in static and dynamic RSA using the marker method as the benchmark.

Methods

Bone models were created from CT scans, and tantalum beads were implanted into the tibia and femur of eight human cadaver knees. Each specimen was secured in a fixture, static and dynamic stereoradiographs were recorded, and the bone models and marker models were fitted to the stereoradiographs.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 675 - 679
1 May 2018
Anderton MJ Hastie GR Paton RW

Aims

The aim of this study was to identify the association between asymmetrical skin creases of the thigh, buttock or inguinal region and pathological developmental dysplasia of the hip (DDH).

Patients and Methods

Between 1 January 1996 and 31 December 2016, all patients referred to our unit from primary or secondary care with risk factors for DDH were assessed in a “one stop” clinic. All had clinical and sonographic assessment by the senior author (RWP) with the results being recorded prospectively. The inclusion criteria for this study were babies and children referred with asymmetrical skin creases. Those with a neurological cause of DDH were excluded. The positive predictive value (PPV) for pathological DDH was calculated.


Bone & Joint Research
Vol. 7, Issue 6 | Pages 406 - 413
1 Jun 2018
Shabestari M Kise NJ Landin MA Sesseng S Hellund JC Reseland JE Eriksen EF Haugen IK

Objectives

Little is known about tissue changes underlying bone marrow lesions (BMLs) in non-weight-bearing joints with osteoarthritis (OA). Our aim was to characterize BMLs in OA of the hand using dynamic histomorphometry. We therefore quantified bone turnover and angiogenesis in subchondral bone at the base of the thumb, and compared the findings with control bone from hip OA.

Methods

Patients with OA at the base of the thumb, or the hip, underwent preoperative MRI to assess BMLs, and tetracycline labelling to determine bone turnover. Three groups were compared: trapezium bones removed by trapeziectomy from patients with thumb base OA (n = 20); femoral heads with (n = 24); and those without (n = 9) BMLs obtained from patients with hip OA who underwent total hip arthroplasty.