Advertisement for orthosearch.org.uk
Results 921 - 940 of 1329
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 617 - 622
1 May 2015
Haddad FS Konan S Tahmassebi J

The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years.

Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14).

Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores.

No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years.

We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems.

Cite this article: Bone Joint J 2015; 97-B:617–22.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1487 - 1493
1 Nov 2012
Wensaas A Gunderson RB Svenningsen S Terjesen T

Deformity after slipped upper femoral epiphysis (SUFE) can cause cam-type femoroacetabular impingement (FAI) and subsequent osteoarthritis (OA). However, there is little information regarding the radiological assessment and clinical consequences at long-term follow-up. We reviewed 36 patients (43 hips) previously treated by in situ fixation for SUFE with a mean follow-up of 37 years (21 to 50). Three observers measured the femoral head ratio (FHR), lateral femoral head ratio (LFHR), α-angle on anteroposterior (AP) and frog-leg lateral views, and anterior femoral head–neck offset ratio (OSR). A Harris hip score < 85 and/or radiologically diagnosed osteoarthritis (OA) was classified as a poor outcome. Patients with SUFE had significantly higher FHR, LFHR and α-angles and lower OSR than a control group of 22 subjects (35 hips) with radiologically normal hips. The interobserver agreement was less, with wider limits of agreement (LOA), in hips with previous SUFE than the control group. At long-term follow-up abnormal α-angles correlated with poor outcome, whereas FHR, LFHR and OSR did not.

We conclude that persistent deformity with radiological cam FAI after SUFE is associated with poorer clinical and radiological long-term outcome. Although the radiological measurements had quite wide limits of agreement, they are useful for the diagnosis of post-slip deformities in clinical practice.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 833 - 838
1 Jun 2011
Huber H Dora C Ramseier LE Buck F Dierauer S

Between June 2001 and November 2008 a modified Dunn osteotomy with a surgical hip dislocation was performed in 30 hips in 28 patients with slipped capital femoral epiphysis. Complications and clinical and radiological outcomes after a mean follow-up of 3.8 years (1.0 to 8.5) were documented. Subjective outcome was assessed using the Harris hip score and the Western Ontario and McMaster Universities osteoarthritis index questionnaire.

Anatomical or near-anatomical reduction was achieved in all cases. The epiphysis in one hip showed no perfusion intra-operatively and developed avascular necrosis. There was an excellent outcome in 28 hips. Failure of the implants with a need for revision surgery occurred in four hips.

Anatomical reduction can be achieved by this technique, with a low risk of avascular necrosis. Cautious follow-up is necessary in order to avoid implant failure.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 10 - 12
1 Aug 2012

The August 2012 Hip & Pelvis Roundup360 looks at: whether cemented hip replacement might be bad for your health; highly cross-linked polyethylene; iHOT-33 - a new hip outcome measure; hamstring injuries; total hip replacement; stemmed metal-on-metal THR; bipolar hemiarthroplasty, neuromuscular disease and dislocation; the high risk of secondary hemiarthroplasty; and whether we have to repair the labrum after all?


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 172 - 176
1 Feb 2014
Mori R Yasunaga Y Yamasaki T Nakashiro J Fujii J Terayama H Ohshima S Ochi M

In Japan, osteoarthritis (OA) of the hip secondary to acetabular dysplasia is very common, and there are few data concerning the pathogeneses and incidence of femoroacetabular impingement (FAI). We have attempted to clarify the radiological prevalence of painful FAI in a cohort of Japanese patients and to investigate the radiological findings. We identified 176 symptomatic patients (202 hips) with Tönnis grade 0 or 1 osteoarthritis, whom we prospectively studied between August 2011 and July 2012. There were 61 men (65 hips) and 115 women (137 hips) with a mean age of 51.8 years (11 to 83). Radiological analyses included the α-angle, centre–edge angle, cross-over sign, pistol grip deformity and femoral head neck ratio. Of the 202 hips, 79 (39.1%) had acetabular dysplasia, while 80 hips (39.6%) had no known aetiology. We found evidence of FAI in 60 hips (29.7%). Radiological FAI findings associated with cam deformity were the most common. There was a significant relationship between the pistol grip deformity and both the α-angle (p < 0.001) and femoral head–neck ratio (p = 0.024). Radiological evidence of symptomatic FAI was not uncommon in these Japanese patients.

Cite this article: Bone Joint J 2013;96-B:172–6.


The repair of chondral lesions associated with femoroacetabular impingement requires specific treatment in addition to that of the impingement. In this single-centre retrospective analysis of a consecutive series of patients we compared treatment with microfracture (MFx) with a technique of enhanced microfracture autologous matrix-induced chondrogenesis (AMIC).

Acetabular grade III and IV chondral lesions measuring between 2 cm2 and 8 cm2 in 147 patients were treated by MFx in 77 and AMIC in 70. The outcome was assessed using the modified Harris hip score at six months and one, two, three, four and five years post-operatively. The outcome in both groups was significantly improved at six months and one year post-operatively. During the subsequent four years the outcome in the MFx group slowly deteriorated, whereas that in the AMIC group remained stable. Six patients in the MFx group subsequently required total hip arthroplasty, compared with none in the AMIC group

We conclude that the short-term clinical outcome improves in patients with acetabular chondral damage following both MFx and AMIC. However, the AMIC group had better and more durable improvement, particularly in patients with large (≥ 4 cm2) lesions.

Cite this article: Bone Joint J 2015; 97-B:628–35.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 312 - 318
1 Mar 2014
Meermans G Van Doorn WJ Koenraadt K Kats J

The orientation of the acetabular component can influence both the short- and long-term outcomes of total hip replacement (THR). We performed a prospective, randomised, controlled trial of two groups, comprising of 40 patients each, in order to compare freehand introduction of the component with introduction using the transverse acetabular ligament (TAL) as a reference for anteversion. Anteversion and inclination were measured on pelvic radiographs.

With respect to anteversion, in the freehand group 22.5% of the components were outside the safe zone versus 0% in the transverse acetabular ligament group (p = 0.002). The mean angle of anteversion in the freehand group was 21° (2° to 35°) which was significantly higher compared with 17° (2° to 25°) in the TAL group (p = 0.004). There was a significant difference comparing the variations of both groups (p = 0.008).

With respect to inclination, in the freehand group 37.5% of the components were outside the safe zone versus 20% in the TAL group (p = 0.14). There was no significant difference regarding the accuracy or variation of the angle of inclination when comparing the two groups.

The transverse acetabular ligament may be used to obtain the appropriate anteversion when introducing the acetabular component during THR, but not acetabular component inclination.

Cite this article: Bone Joint J 2014;96-B:312–18.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 373 - 378
1 Mar 2014
Thomas CJ Smith RP Uzoigwe CE Braybrooke JR

We retrospectively reviewed 2989 consecutive patients with a mean age of 81 (21 to 105) and a female to male ratio of 5:2 who were admitted to our hip fracture unit between July 2009 and February 2013. We compared weekday and weekend admission and weekday and weekend surgery 30-day mortality rates for hip fractures treated both surgically and conservatively. After adjusting for confounders, weekend admission was independently and significantly associated with a rise in 30-day mortality (odds ratio (OR) 1.4, 95% confidence interval (CI) 1.02 to 1.9; p = 0.039) for patients undergoing hip fracture surgery. There was no increase in mortality associated with weekend surgery (OR 1.2, 95% CI 0.8 to 1.7; p = 0.39). All hip fracture patients, whether managed surgically or conservatively, were more likely to die as an inpatient when admitted at the weekend (OR 1.4, 95% CI 1.02 to 1.80; p = 0.032), despite our unit having a comparatively low overall inpatient mortality (8.7%). Hip fracture patients admitted over the weekend appear to have a greater risk of death despite having a consultant-led service.

Cite this article: Bone Joint J 2014;96-B:373–8.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 442 - 448
1 Apr 2014
Feyen H Shimmin AJ

Many different lengths of stem are available for use in primary total hip replacement, and the morphology of the proximal femur varies greatly. The more recently developed shortened stems provide a distribution of stress which closely mimics that of the native femur. Shortening the femoral component potentially comes at the cost of decreased initial stability. Clinical studies on the performance of shortened cemented and cementless stems are promising, although long-term follow-up studies are lacking. We provide an overview of the current literature on the anatomical features of the proximal femur and the biomechanical aspects and clinical outcomes associated with the length of the femoral component in primary hip replacement, and suggest a classification system for the length of femoral stems.

Cite this article: Bone Joint J 2014;96-B:442-8.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 14 - 16
1 Feb 2015

The February 2015 Hip & Pelvis Roundup360 looks at: Hip arthroplasty in Down syndrome; Bulk femoral autograft successful in acetabular reconstruction; Arthroplasty follow-up: is the internet the solution?; Total hip arthroplasty following acetabular fracture; Salvage arthroplasty following failed hip internal fixation; Bone banking sensible financially and clinically; Allogenic blood transfusion in arthroplasty.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 14 - 17
1 Feb 2014

The February 2014 Hip & Pelvis Roundup360 looks at: length of stay; cementless metaphyseal fixation; mortality trends in over 400,000 total hip replacements; antibiotics in hip fracture surgery; blood supply to the femoral head after dislocation; resurfacing and THR in metal-on-metal replacement; diabetes and hip replacement; bone remodelling over two decades following hip replacement; and whether bisphosphonates affect acetabular fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 471 - 476
1 Apr 2012
Holland JP Langton DJ Hashmi M

We present the clinical results and survivorship of consecutive 100 Birmingham Hip Resurfacings in 90 patients at a minimum follow-up of ten years. All procedures were carried out by an independent surgeon who commenced a prospective study in 1998. Patients were assessed clinically using the Western Ontario and McMaster Universities osteoarthritis index, Short-Form 36, Harris hip score and University of California, Los Angeles activity score. Radiological analysis was performed by an independent observer and blood metal ion levels concentrations were measured at ten years post-operatively in 62 patients. The median acetabular component inclination was 46.2° (34° to 59°) and anteversion 11.0° (0° to 30°). The median chromium concentration in the unilateral group was 1.74 (0.41 to 15.23) and for the bilateral group was 2.98 (1.57 to 18.01). The equivalent values for cobalt were 1.67 (0.54 to 20.4) and 1.88 (1.38 to 19.32).

In total there were eight failures giving an overall survival at ten years of 92% (95% confidence interval (CI) 86.7 to 97.3). BHR in male patients had an improved survivorship of 94.6% (95% CI 89.4 to 100) compared with females at 84.6% (95% CI 70.7 to 98.5), but this did not reach statistical significance (p = 0.119). Four of the nine BHRs with a bearing diameter of 42 mm failed.

The overall results were consistent with data produced from other centres in that the clinical outcome of large male patients was extremely encouraging, whereas the survival of the smaller joints was less satisfactory.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 312 - 317
1 Mar 2015
Amanatullah DF Howard JL Siman H Trousdale RT Mabry TM Berry DJ

Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 patients using a single fluted, tapered, modular femoral stem design. Pre-operative diagnoses included aseptic loosening, infection and peri-prosthetic fracture. Bone loss was categorised pre-operatively as Paprosky types III-IV, or Vancouver B3 in patients with a peri-prosthetic fracture. The mean clinical follow-up was 6.4 years (2 to 12). A total of 47 patients had peri-operative complications, 27 of whom required further surgery. However, most of these further operations involved retention of a well-fixed femoral stem, and 88/92 femoral components (97%) remained in situ. Of the four components requiring revision, three were revised for infection and were well fixed at the time of revision; only one (1%) was revised for aseptic loosening. The most common complications were post-operative instability (17 hips, 19%) and intra-operative femoral fracture during insertion of the stem (11 hips, 12%). Diaphyseal stress shielding was noted in 20 hips (22%). There were no fractures of the femoral component. At the final follow-up 78% of patients had minimal or no pain.

Revision THA in patients with extensive proximal femoral bone loss using the Link MP fluted, tapered, modular stem led to a high rate of osseointegration of the stem at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:312–17.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 130 - 138
1 Apr 2014
Shapiro F Connolly S Zurakowski D Flynn E Jaramillo D

Objectives

An experimental piglet model induces avascular necrosis (AVN) and deformation of the femoral head but its secondary effects on the developing acetabulum have not been studied. The aim of this study was to assess the development of secondary acetabular deformation following femoral head ischemia.

Methods

Intracapsular circumferential ligation at the base of the femoral neck and sectioning of the ligamentum teres were performed in three week old piglets. MRI was then used for qualitative and quantitative studies of the acetabula in operated and non-operated hips in eight piglets from 48 hours to eight weeks post-surgery. Specimen photographs and histological sections of the acetabula were done at the end of the study.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 26 - 28
1 Dec 2013

The December 2013 Trauma Roundup360 looks at: Re-operation for intertrochanteric hip fractures; Are twin incisions better than one round the acetabulum?; Salvage osteotomy for calcaneal fractures; Posterior dislocation; Should MRSA be covered in open fractures?; Characterising the saline load test; Has it healed: hip fractures under the spotlight; and stem cells present in atrophic non-union.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 181 - 187
1 Feb 2014
Owen DH Russell NC Smith PN Walter WL

Squeaking arising from a ceramic-on-ceramic (CoC) total hip replacement (THR) may cause patient concern and in some cases causes patients to seek revision surgery. We performed a meta-analysis to determine the incidence of squeaking and the incidence of revision surgery for squeaking. A total of 43 studies including 16 828 CoC THR that reported squeaking, or revision for squeaking, were entered into the analysis. The incidence of squeaking was 4.2% and the incidence of revision for squeaking was 0.2%. The incidence of squeaking in patients receiving the Accolade femoral stem was 8.3%, and the incidence of revision for squeaking in these patients was 1.3%.

Cite this article: Bone Joint J 2014;96-B:181–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 769 - 776
1 Jun 2011
Hogervorst T Bouma H de Boer SF de Vos J

We examined the morphology of mammalian hips asking whether evolution can explain the morphology of impingement in human hips. We describe two stereotypical mammalian hips, coxa recta and coxa rotunda. Coxa recta is characterised by a straight or aspherical section on the femoral head or head-neck junction. It is a sturdy hip seen mostly in runners and jumpers. Coxa rotunda has a round femoral head with ample head-neck offset, and is seen mostly in climbers and swimmers.

Hominid evolution offers an explanation for the variants in hip morphology associated with impingement. The evolutionary conflict between upright gait and the birth of a large-brained fetus is expressed in the female pelvis and hip, and can explain pincer impingement in a coxa profunda. In the male hip, evolution can explain cam impingement in coxa recta as an adaptation for running.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 35 - 36
1 Dec 2014
Das A


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1344 - 1350
1 Oct 2012
Penny JO Ding M Varmarken JE Ovesen O Overgaard S

Radiostereometric analysis (RSA) can detect early micromovement in unstable implant designs which are likely subsequently to have a high failure rate. In 2010, the Articular Surface Replacement (ASR) was withdrawn because of a high failure rate. In 19 ASR femoral components, the mean micromovement over the first two years after implantation was 0.107 mm (sd 0.513) laterally, 0.055 mm (sd 0.204) distally and 0.150 mm (sd 0.413) anteriorly. The mean backward tilt around the x-axis was -0.08° (sd 1.088), mean internal rotation was 0.165° (sd 0.924) and mean varus tilt 0.238° (sd 0.420). The baseline to two-year varus tilt was statistically significant from zero movement, but there was no significant movement from one year onwards.

We conclude that the ASR femoral component achieves initial stability and that early migration is not the mode of failure for this resurfacing arthroplasty.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 2 - 5
1 Feb 2015
Wright GM Porteous MJ