Total hip replacement in patients with advanced osteonecrosis of the femoral head is often complicated by early loosening of the femoral component. Recent evidence has suggested that abnormal bone extending into the proximal femur may be responsible for the early failure of the femoral component. We aimed to identify which patients were at high risk of early failure by evaluating gadolinium-enhanced MR images of histologically-confirmed osteonecrotic lesions beyond the femoral head. Although the MR signal intensity has been shown to correlate well with osteonecrosis in the femoral head, it was found to be relatively insensitive at identifying lesions below the head, with a sensitivity of only 51% and a predictive value of a negative result of only 48%. However, the specificity was 90%, with the predictive value of a positive MRI finding being 86%. Only those patients with osteonecrosis of the femoral head secondary to sickle-cell disease, who are known to be at high risk of early loosening, had changes in the MR signal in the greater trochanter and the femoral shaft. This observation suggests that changes in the MR signal beyond the femoral head may represent osteonecrotic lesions in areas essential for the fixation of the femoral component. Pre-operative identification of such lesions in the neck of the femur may be important when considering hip resurfacing for osteonecrosis of the femoral head, following which early loosening of the femoral component and fracture of the neck are possible complications.
We evaluated the results of fibular centralisation as a stand alone technique to reconstruct defects that occurred after resection of tumours involving the tibial diaphysis and distal metaphysis. Between January 2003 and December 2006, 15 patients underwent excision of tumours of the tibial diaphysis or distal metaphysis and reconstruction by fibular centralisation. Their mean age was 17 years (7 to 40). Two patients were excluded; one died from the complications of chemotherapy and a second needed a below-knee amputation for a recurrent giant-cell tumour. A total of 13 patients were reviewed after a mean follow-up of 29 months (16 to 48). Only 16 of 26 host graft junctions united primarily. Ten junctions in ten patients needed one or more further procedure before union was achieved. At final follow-up 12 of the 13 patients had fully united grafts; 11 walked without aids. The mean time to union at the junctions that united was 12 months (3 to 36). The mean Musculoskeletal Tumor Society Score was 24.7 (16 to 30). Fibular centralisation is a durable reconstruction for defects of the tibial diaphysis and distal metaphysis with an acceptable functional outcome. Stable osteosynthesis is the key to successful union. Additional bone grafting is recommended for patients who need postoperative radiotherapy.
The December 2012 Hip &
Pelvis Roundup360 looks at: swimming against the tide with resurfacing; hip impingement surgery; the relationship between obesity and co-morbidities and joint replacement infection; cemented hips; cross-linked polyethylene notching; whether cement is necessary in oncological arthroplasty; and how total hip replacement may result in weight gain.
Osteochondroma is the most common benign bone tumour. The risk of sarcomatous change in an isolated lesion is approximately 1%. We report a case of an isolated osteochondroma which appeared benign on clinical and plain radiographic examination but routine histological analysis revealed non-Hodgkin’s lymphoma in the underlying bone. This association has not previously been reported and the case emphasises the importance of routine histological analysis, even if a lesion appears benign.
We describe a case of lumbosacral plexopathy caused by an isolated aneurysm of the common iliac artery. The patient presented with worsening low back pain, progressive numbness and weakness of the right leg in the L2-L4 distribution. This had previously been diagnosed as sciatica. A CT scan showed an aneurysm of the right common iliac artery which measured 8 cm in diameter. Despite being listed for emergency endovascular stenting, the aneurysm ruptured and the patient died. It is important to distinguish a lumbosacral plexopathy from sciatica and to bear in mind its treatable causes which include aneurysms of the common and internal iliac arteries.
We review the treatment of pelvic Ewing’s sarcoma by the implantation of extracorporeally-irradiated (ECI) autografts and compare the outcome with that of other reported methods. We treated 13 patients with ECI autografts between 1994 and 2004. There were seven males and six females with a median age of 15.7 years (interquartile range (IQR) 12.2 to 21.7). At a median follow-up of five years (IQR 1.8 to 7.4), the disease-free survival was 69% overall, and 75% if one patient with local recurrence after initial treatment elsewhere was excluded. Four patients died from distant metastases at a mean of 17 months (13 to 23). There were three complications which required operative intervention; one was a deep infection which required removal of the graft. The functional results gave a mean Musculoskeletal Tumor Society score of 85% (60% to 97%), a mean Toronto extremity salvage score of 86% (69% to 100%) and a mean Harris hip score of 92 (67 to 100). We conclude that ECI grafting is a suitable form of treatment for localised and resectable pelvic Ewing’s sarcoma.
We carried out a morphometric analysis of the acetabulum following Dega osteotomy in patients with cerebral palsy using three-dimensional CT. We assessed 17 acetabula in 12 patients with instability of the hip. A Dega osteotomy and varus derotation femoral osteotomy were performed in all 17 hips. Three-dimensional CT scans were taken before and approximately one year after operation. Acetabular cover was evaluated using anterosuperior, superolateral and posterosuperior acetabular indices, and the change in the acetabular volume was calculated. Inter- and intra-observer reliability was assessed using the intraclass correlation coefficient. After the osteotomy, the anterosuperior, superolateral and posterosuperior cover had improved significantly towards the value seen in a control group. The mean acetabular volume increased by 68%.
Between 1986 and 1991 we implanted 331 consecutive Furlong hydroxyapatite-coated femoral components of a total hip replacement in 291 patients. A cemented acetabular prosthesis was used in 217 hips and a hydroxyapatite-coated component in 114. We describe the long-term clinical and radiological survival of the femoral component at a mean follow-up of 17.5 years (15 to 21). Only two patients (0.68%) were lost to follow-up. With revision of the femoral component for any reason as the endpoint, the survival at a mean of 17 years was 97.4% (95% confidence interval 94.1 to 99.5), and with revision for aseptic loosening as the endpoint it was 100%. The survival at a maximum of 21 years with revision of the femoral component for any reason as the endpoint was 97.4% (95% confidence interval 81.0 or 99.5). These results compare favourably with the best long-term results of cemented or uncemented femoral components used in total hip replacement.
Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.
We evaluated triple-phase bone scintigraphy in the differential diagnosis of peri-prosthetic infection in 46 patients with a total hip replacement or bipolar hemiarthroplasty who were due for revision surgery. There were 18 men and 28 women, with a mean age at operation of 64.6 years (28 to 81). We defined peri-prosthetic infection as an increased uptake of radioisotope in all the phases of triple-phase bone scintigraphy and validated these results against the histological and/or microbiology results in every case. The positive and negative predictive values for the presence of infection were 83% and 93%, respectively. The diagnostic sensitivity was 88% and the specificity was 90%. This study indicates that triple-phase bone scintigraphy is a useful tool in the detection of peri-prosthetic infection and offers a cost-effective method of screening.
We describe two patients aged 16 and 25 years with osteogenesis imperfecta who sustained displaced fractures of the acetabulum following minor trauma. The femoral heads were deformed by impact against the acetabular margin and both cases underwent surgical reconstruction. The quality of the bone and soft tissues made the operations challenging. There were potential complications specific to osteogenesis imperfecta, including bleeding, the creation of secondary fracture lines and shredding of the soft-tissue. The cases provide useful guidelines for addressing these difficulties.
We describe a patient with cerebral palsy, of normal intelligence, who could not walk but who by the age of 16 had been successfully managed with a staged bilateral total hip arthroplasty using a constrained liner.
We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study. Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality. We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip.
We undertook a retrospective review of 24 arthroscopic procedures in patients with symptomatic ossicles around the malleoli of the ankle. Most of the patients had a history of injury and localised tenderness in the area coinciding with the radiological findings. Contrast-enhanced three-dimensional fast-spoiled gradient-echo MRI was performed and the results compared with the arthroscopic findings. An enhanced signal surrounding soft tissue corresponding to synovial inflammation and impingement was found in 20 patients (83%). The arthroscopic findings correlated well with those of our MRI technique and the sensitivity was estimated to be 91%. At a mean follow-up of 30.5 months (20 to 86) the mean American Orthopaedic Foot and Ankle Society score improved from 74.5 to 93 points (p <
0.001). Overall, the rate of patient satisfaction was 88%. Our results indicate that symptomatic ossicles of the malleoli respond well to arthroscopic treatment.
Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). The median pre-operative bone defect score was 3 (interquartile range (IQR) 2 to 3) using the Endo-Klinik classification. The median subsidence at one year post-operatively was 2 mm (IQR 1 to 3). At the final review the median Harris hip score was 80.6 (IQR 67.6 to 88.9) and the median subsidence 2 mm (IQR 1 to 4). Incorporation of the allograft into trabecular bone and secondary remodelling were noted radiologically at the final follow-up in 87% (393 of 452 zones) and 40% (181 of 452 zones), respectively. Subsidence of the Exeter stem correlated with the pre-operative Endo-Klinik bone loss score (p = 0.037). The degree of subsidence at one year had a strong association with long-term subsidence (p <
0.001). There was a significant correlation between previous revision surgery and a poor Harris Hip score (p = 0.028), and those who had undergone previous revision surgery for infection had a higher risk of complications (p = 0.048). Survivorship at 10.5 years with any further femoral operation as the end-point was 92% (95% confidence interval 82 to 97).
Four patients who developed malignant synovial tumours are described; one with chondromatosis developed a synovial chondrosarcoma and three with pigmented villonodular synovitis developed malignant change. The relevant literature is discussed.
Fractures of the proximal femur are one of the
greatest challenges facing the medical community, constituting a
heavy socioeconomic burden worldwide. The National Hip Fracture
Audit currently provides a framework for service evaluation. This
evaluation is based upon the assessment of process rather than assessment
of patient-centred outcome and therefore it fails to provide meaningful
data regarding the clinical effectiveness of treatments. This study
aims to capture data from the cohort of patients who present with
a fracture of the proximal femur at a single United Kingdom Major
Trauma Centre. Patient-centred outcomes will be recorded and provide
a baseline cohort within which to test the clinical effectiveness
of experimental interventions.
Pain is the main indication for performing total knee replacement (TKR). In most patients after TKR there is an improvement, but a few continue to have pain. Generally, the cause of the pain can be addressed when it is identified. However, unexplained pain can be more difficult to manage because revision surgery is likely to be unrewarding in this group. In our study of 622 cemented TKRs in 512 patients with a mean age of 69 years (23 to 90) treated between January 1995 and August 1998, we identified 24 patients (knees) with unexplained pain at six months. This group was followed for five years (data was unavailable for 18 knees) and ten patients (55.5%) went on to show an improvement without intervention. In the case of unexplained pain, management decisions must be carefully considered, but reassurance can be offered to patients that the pain will improve in more than half with time.
We describe the results of a randomised, prospective study of 200 ankle replacements carried out between March 2000 and July 2003 at a single centre to compare the Buechel-Pappas (BP) and the Scandinavian Total Ankle Replacement (STAR) implant with a minimum follow-up of 36 months. The two prostheses were similar in design consisting of three components with a meniscal polyethylene bearing which was highly congruent on its planar tibial surface and on its curved talar surface. However, the designs were markedly different with respect to the geometry of the articular surface of the talus and its overall shape. A total of 16 ankles (18%) was revised, of which 12 were from the BP group and four of the STAR group. The six-year survivorship of the BP design was 79% (95% confidence interval (CI) 63.4 to 88.5 and of the STAR 95% (95% CI 87.2 to 98.1). The difference did not reach statistical significance (p = 0.09). However, varus or valgus deformity before surgery did have a significant effect) (p = 0.02) on survivorship in both groups, with the likelihood of revision being directly proportional to the size of the angular deformity. Our findings support previous studies which suggested that total ankle replacement should be undertaken with extreme caution in the presence of marked varus or valgus deformity.
We have examined the outcome of 400 consecutive patients who underwent total knee replacement with the Low Contact Stress mobile-bearing system between 1993 and 1994 and were followed up for a minimum of ten years. All operations were performed by surgeons in Christchurch, New Zealand, who used no other knee prosthesis during the study time. At ten years after operation 238 patients (244 knees) remained for independent clinical and radiological assessment. There was a significant improvement (p <
0.001) in the postoperative knee scores at one, three, seven and ten years, although a slight deterioration in the score occurred between seven and ten years which did not reach statistical significance. The survival for polyethylene wear or loosening was 97% (95% CI 96 to 98) and survival using reoperation for any cause was 92% (95% CI 90 to 94) at 12 years. Polyethylene wear was more common in the meniscal-bearing component, with five knees requiring revision and a further eight demonstrating early wear. Osteolysis was not seen in the rotating platform component, but was present in three of the meniscal-bearing knees. There was no association between the radiological alignment at one year and those knees that subsequently required revision. However, there was an association between the overall limb alignment and the Western Ontario McMasters University score (p <
0.001). The Low Contact Stress mobile-bearing total knee replacement has proved to be a reliable implant at ten years when used in primary knee replacement irrespective of the deformity and diagnosis.