Advertisement for orthosearch.org.uk
Results 841 - 860 of 5473
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 267 - 270
1 Mar 1994
Witt J McCullough C

We report the results of anterior soft-tissue release of the hip for fixed flexion deformity in 17 patients (31 hips) with juvenile chronic arthritis. The mean age at operation was 8 years 6 months. All the patients were reviewed at one and three years and 11 (21 hips) were available for review at five years. The results were good as regards early pain relief and improved mobility. At one year, the average fixed flexion deformity was reduced from 35 degrees to 9.5 degrees, and at three years it was 18 degrees. This degree of improvement was maintained in the hips followed for five years. At 5 to 12 years' follow-up (mean 6.7) seven patients (14 hips) have required no further surgery and have maintained an acceptable range of motion. We discuss the influence of surgery on radiographic changes and on femoral neck anteversion


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 688 - 692
1 Sep 1993
Barrack R Burke D Cook S Skinner H Harris W

We report complications from the use of modular components in 20 hip replacements in 18 patients. Fifteen complications (in 13 patients) were related to failure of a modular interface after operation. Femoral head detachment from its trunnion was seen in 6 hips from trauma (3), reduction of a dislocation (2), and normal activity (1). In one case the base of the trunnion fractured below an extra-long modular head. In seven other hips the modular polyethylene liner dislodged from its shell, causing severe damage to the shell in four cases with extensive metallosis. In one other hip an asymmetrical polyethylene liner rotated, resulting in impingement of the femoral component and recurrent dislocation. Operative errors were seen in five cases: implantation of a trial acetabular component in one; and mismatching between the size of the femoral head and the acetabular component in the others. Surgeons who use hip replacements with modular components should be aware of the potential for operative error and of the importance of early treatment for postoperative mechanical failure


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 174 - 178
1 Mar 1988
Bos C Bloem J Obermann W Rozing P

A study of structures which obstruct reduction of hip dislocation was performed on 15 hips by magnetic resonance imaging (MRI). Before treatment started, MRI studies were performed on 10 patients, six of whom were treated conservatively, after which further MRI studies helped to establish a concentric reduction. In the other four conservative treatment failed and they were operated on; in them the MRI studies were compared with arthrographic and surgical findings. In all but one of these 10 patients, MRI enabled us to differentiate between an everted and an inverted limbus. In five other patients with unsatisfactory development of the hip following closed reduction, MRI was compared with earlier arthrographic studies. MRI provided accurate anatomical information which would not have been obtained by arthrography. It clearly has great potential in assisting the surgeon to select the appropriate form of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 632 - 637
1 Nov 1969
Liebenberg F Dommisse GF

1. Two cases of recurrent post-traumatic dislocation of the hip are reported. 2. The literature is reviewed and the rarity of the condition is emphasised. Only twenty-two cases have been previously reported, eleven in adults and eleven in children. 3. The sequence of events leading to recurrent dislocation is not understood but the following important facts emerge. The initial incident could not be distinguished from that causing uncomplicated dislocations. There was a significant delay in reduction in a number of cases. Subsequent dislocations followed minor injury. A large defect in the posterior capsule with a large synovial-lined pouch or false joint was found at operation in both our cases. The ligamentum teres was not seen at operation. The surgeon was unable to redislocate the hips during the operation. 4. In both cases reported here treatment was by excision of the posterior pouch and repair of the capsular defect. 5. Based on the above facts some tentative deductions are made


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 130 - 135
1 Jan 2010
Culliford DJ Maskell J Beard DJ Murray DW Price AJ Arden NK

Using the General Practice Research Database, we examined the temporal changes in the rates of primary total hip (THR) and total knee (TKR) replacement, the age at operation and the female-to-male ratio between 1991 and 2006 in the United Kingdom. We identified 27 113 patients with THR and 23 843 with TKR. The rate of performance of THR and TKR had increased significantly (p < 0.0001 for both) during the 16-year period and was greater for TKR, especially in the last five years. The mean age at operation was greater for women than for men and had remained stable throughout the period of study. The female-to-male ratio was higher for THR and TKR and had remained stable. The data support the notion that the rate of joint replacement is increasing in the United Kingdom with the rate of TKR rising at the highest rate. The perception that the mean age for TKR has decreased over time is not supported


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 1 | Pages 22 - 29
1 Feb 1952
D'Aubigné RM

Arthroplasty, with normal or nearly normal reposition, is possible in most old congenital dislocations of the hip in young adults. Reposition is possible even in very high dislocation, but it is difficult or impossible in aged patients and when arthritic changes have taken place. The reduction equalises the length of the extremities in unilateral cases, but makes operation on both sides necessary in bilateral cases. Post-operative complications may be largely avoided by a good technique and careful post-operative treatment. Stability is good, and consequently the limp is generally reduced. Mobility is as a rule sufficient, though often less than before operation when the hip was normally or excessively mobile. Pain is very often relieved or greatly reduced, but walking is generally limited. Even if the radiographic appearance of the hip is almost normal, the functional result may be imperfect. This assessment is probably pessimistic, for two reasons: first, patients operated on are still improving; second, the improved technique of the later operations should give better results. Nevertheless, arthroplasty with reduction should be proposed to patients only suffering severe functional disability


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1192 - 1197
1 Sep 2014
Egol KA Marcano AI Lewis L Tejwani NC McLaurin TM Davidovitch RI

In March 2012, an algorithm for the treatment of intertrochanteric fractures of the hip was introduced in our academic department of Orthopaedic Surgery. It included the use of specified implants for particular patterns of fracture. In this cohort study, 102 consecutive patients presenting with an intertrochanteric fracture were followed prospectively (post-algorithm group). Another 117 consecutive patients who had been treated immediately prior to the implementation of the algorithm were identified retrospectively as a control group (pre-algorithm group). The total cost of the implants prior to implementation of the algorithm was $357 457 (mean: $3055 (1947 to 4133)); compared with $255 120 (mean: $2501 (1052 to 4133)) after its implementation. There was a trend toward fewer complications in patients who were treated using the algorithm (33% pre- versus 22.5% post-algorithm; p = 0.088). Application of the algorithm to the pre-algorithm group revealed a potential overall cost saving of $70 295. The implementation of an evidence-based algorithm for the treatment of intertrochanteric fractures reduced costs while maintaining quality of care with a lower rate of complications and re-admissions. Cite this article: Bone Joint J 2014;96-B:1192–7


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 363 - 365
1 Apr 2003
Fleming P Lenehan B O’Rourke S McHugh P Kaar K McCabe JP

Injuries to the sciatic nerve are an occasional complication of surgery to the hip and acetabulum, and traction is frequently the causative mechanism. In vitro and animal experiments have shown that increased tensile strain on peripheral nerves, when applied for prolonged periods, impairs nerve function. We have used video-extensometry to measure strain on the human sciatic nerve during total hip replacement (THR). Ten consecutive patients with a mean age of 72 years undergoing primary THR by the posterior approach were recruited, and strains in the sciatic nerve were measured in different combinations of flexion and extension of the hip and knee, before dislocation of the hip. Significant increases (p = 0.02) in strain in the sciatic nerve were observed in flexion of the hip and extension of the knee. The mean increase was 26% (19% to 30%). In animal studies increases of this magnitude have been shown to impair electrophysiological function in peripheral nerves. Our results suggest that excessive flexion of the hip and extension of the knee should be avoided during THR


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 969 - 974
1 Sep 2003
Drescher W Fürst M Hahne HJ Helfenstein A Petersen W Hassenpflug J

The treatment of osteonecrosis of the femoral head (FHN) is controversial. It mainly occurs in young patients in whom total hip replacement is best avoided because of an increased risk of revision. The objective of this long-term follow-up study was to evaluate the outcome of intertrochanteric flexion osteotomy as a hip joint preserving operation for FHN. Over a 19-year period we carried out 70 intertrochanteric flexion osteotomies for FHN in 64 patients. The mean follow-up was 10.4 years (3.0 to 20.3). The overall mean Harris hip score increased from 51 points preoperatively to 71 points postoperatively. Six patients (9%) developed early postoperative complications. A total of 19 hips (27%) underwent total hip arthroplasty at a mean of 8.7 years after osteotomy. The five-year survival rate was 90%. Survival rates of hips in Ficat stage 2 were higher than those in stages 3 or 4. Hips with a preoperative necrotic angle of < 200° had a better survival probability than those with a necrotic angle > 200°. Our findings suggest that flexion osteotomy is a safe and effective procedure in Ficat stage 2 and 3 FHN, preferably with a necrotic angle of < 200°


Bone & Joint 360
Vol. 5, Issue 2 | Pages 11 - 13
1 Apr 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 549 - 553
1 Jul 1990
Bickerstaff D Neal L Booth A Brennan P Bell M

We made a prospective study of 111 children with acute hip pain to assess whether ultrasound can replace traditional radiography. An effusion was diagnosed in 71% by ultrasound but in only 15% by radiography. This effusion persisted for a mean of nine days; symptoms lasted for five days. Two patients found to have Perthes' disease had longer-lasting effusion and symptoms. Patients without an effusion had no obvious cause for their pain, so the pressure of an effusion from a transient synovitis does not account for all patients with irritable hips. Patients with an effusion persisting for over 24 days (the mean + 2 s.d. of our series) had more symptoms, a significantly larger effusion and greater limitation of movement. They may be more at risk for avascular necrosis. We found that radiographic examination influenced the immediate management of only two patients, those with Perthes' disease. We therefore propose a protocol of management for irritable hip, using ultrasonography at the first presentation of certain categories of patients. This would reduce the number of early radiographs by 75%


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 255 - 258
1 Mar 1999
Paton RW Srinivasan MS Shah B Hollis S

Between May 1992 and April 1997, there were 20 452 births in the Blackburn District. In the same period 1107 infants with hip ‘at-risk’ factors were screened prospectively by ultrasound. We recorded the presence of dislocation and dysplasia detected under the age of six months using Graf’s alpha angle. Early dislocation was present in 36 hips (34 dislocatable and 2 irreducible). Of the 36 unstable hips, 30 (83%) were referred as being Ortolani-positive or unstable; 25 (69%) of these had at least one of the risk factors. Only 11 (31%) were identified from the ‘at-risk’ screening programme alone (0.54 per 1000 live births). Eight cases of ‘late’ dislocation presented after the age of six months (0.39 per 1000 live births). The overall rate of dislocation was 2.2 per 1000 live births. Only 31% of the dislocated hips belonged to a major ‘at-risk’ group. Statistical analysis confirmed that the risk factors had a relatively poor predictive value if used as a screening test for dislocation. In infants referred for doubtful clinical instability, one dislocation was detected for every 11 infants screened (95% confidence interval (CI) 8 to 17) whereas in infants referred because of the presence of any of the major ‘at-risk’ factors the rate was one in 75 (95% CI 42 to 149). Routine ultrasound screening of the ‘at-risk’ groups on their own is of little value in significantly reducing the rate of ‘late’ dislocation in DDH, but screening clinically unstable hips alone or associated with ‘at-risk’ factors has a high rate of detection


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 561 - 565
1 May 2000
Gaine WJ Ramamohan NA Hussein NA Hullin MG McCreath SW

We have studied prospectively the outcome of wound discharge in patients after arthroplasty of the hip and knee. Over a period of 3.5 years 530 primary arthroplasties were carried out in one hospital. Postoperative wound infections developed in 82. At a mean follow-up of two years a comparison was made between these patients and 82 with healthy wounds, in terms of symptoms and signs of deep infection. There was an incidence of 1.1% of early deep infection, within six weeks in all cases. The rate of ‘superficial’ infection was 17.3% in the hips, 10.5% in the knees and 14.3% in total. At a mean follow-up of 26 months, there were no significant differences between the patients with infected wounds and a matched group of patients with healthy wounds in terms of the ESR, level of C-reactive protein, white cell count and radiological scores, but clinical scores were significantly worse in the patients with infected knees (p < 0.05). The length of stay was also significantly longer in this group (mean 14.6 days in the healthy wound group, 19 days in the problem group; p < 0.005). There was, however, no convincing evidence that these wound infections led to deep infection and early revision in the early to medium follow-up period. A larger and longer prospective trial would be necessary to shed more light on this potential problem


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 742 - 750
1 Jul 2001
Kim Y Kim J Cho S

We have reviewed 70 patients with bilateral simultaneous total hip arthroplasties to determine the rate of failure and to compare polyethylene wear and osteolysis between an implant with a cobalt-chrome head and Hylamer liner with that of a zirconia head and Hylamer liner. The mean thickness of the polyethylene liner was 11.0 mm (8.8 to 12.2) in the hip with a zirconia head and 10.7 mm (8.8 to 12.2) in that with a cobalt-chrome head. At follow-up at 6.4 years no acetabular or femoral component had been revised for aseptic loosening and no acetabular or femoral component was loose according to radiological criteria in both the cemented and cementless groups. The mean rate of linear wear and annual wear rate were highest in the 22 mm zirconia femoral head (1.25 mm (SD 1.05) and 0.21 mm (SD 0.18), respectively) and lowest in the 22 mm cobalt-chrome femoral head (0.70 mm (SD 0.39) and 0.12 mm (SD 0.07), respectively). The mean volumetric wear was highest in the 28 mm zirconia femoral head (730.79 mm. 3. ) and lowest in the 22 mm cobalt-chrome femoral head (264.67 mm. 3. ), but if the results were compared by size of the femoral head and type of material there was no statistical difference (p > 0.05). Sequential measurements of annual wear showed that the zirconia femoral head had a relatively higher rate of penetration than the cobalt-chrome head over the first three years; thereafter the rate of wear was reduced and compared favourably with that of cobalt-chrome heads. There was a statistically significant relationship between the wear of the polyethylene liner and the age of the patient, male gender and the degree of abduction angle of the cup, but not diagnosis, weight, hip score, range of movement, or amount of anteversion. Osteolysis was identified on both sides of the acetabulum in six patients (9%). Of 12 hips with acetabular osteolysis, six had a 28 mm cobalt-chrome femoral head and the remaining six a 28 mm zirconia head. Osteolysis was observed in zones 1A and 7A of the femur in two hips (3%) with a 28 mm zirconia head (cemented hip) and in four (6%) with a 28 mm cobalt-chrome femoral head (cementless hip). Our findings suggest that although the performance of a zirconia femoral head with a Hylamer liner was not statistically different from that of a cobalt-chrome femoral head and Hylamer liner, there was a trend for the zirconia head to be worse than the cobalt-chrome femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 582 - 589
1 Jul 1999
Røkkum M Brandt M Bye K Hetland KR Waage S Reigstad A

We have followed up for a period of seven to nine years 100 consecutive arthroplasties of the hip in which an entirely HA-coated implant had been used. The clinical results were excellent and bony incorporation was extensive in all components. No stem became loose or subsided but five cups were revised because of loosening after 3.8 to 5.5 years, having functioned painlessly and shown radiological ingrowth. Revision procedures because of excessive polyethylene wear have been performed on 18 hips and are planned for six more. Two eroded metal backings with worn-through polyethylene were exchanged; six hips showed metallosis without polyethylene wear-through. There were two cases of granulomatous cysts in the groin and 66 hips had osteolysis located periarticularly, in the greater trochanter or in the acetabulum


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 565 - 567
1 Apr 2005
Baumgart R Krammer M Winkler A Hinterwimmer S Muensterer O Mutschler W

We report the case of a 22-year-old woman who underwent plate and screw fixation for a traumatic left acetabular fracture and fixation with cancellous screws for an associated femoral neck fracture. Two months later, the internal fixation became infected and was removed. This resulted in a painful high dislocation of the hip. We solved the problem with continuous soft-tissue distraction using a fully implantable motorised distraction nail in order to reduce the proximal femur prior to total hip arthroplasty. To our knowledge, this is the first time that reduction of a high dislocation of the hip has been performed using such a system


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1173 - 1177
1 Nov 2003
Yamada N Maeda S Fujii G Kita A Funayama K Kokubun S

The efficacy of traction before an attempted closed reduction for patients with developmental dislocation of the hip remains controversial. We treated 55 children (62 dislocations of the hip) by preliminary, prolonged traction for a mean of eight weeks. All were followed up for at least two years in order to observe the development of any avascular changes within the femoral head. Of the 55 children, 27 (31 dislocations) were followed up until they were over six years of age. Fifty-seven of the 62 hips (92%) showed a successful closed reduction. Only one had radiological evidence of avascular necrosis of the femoral head. Of the 31 hips which were followed up to over six years of age, 15 (48%) showed residual subluxation. Our method of prolonged preliminary traction leads to a high rate of successful closed reduction, a low incidence of avascular necrosis and a reduced need for secondary operations


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 462 - 466
1 May 1997
Vasudevan PN Vaidyalingam KV Nair PB

In 1895 Trendelenburg described his sign to determine the integrity of hip function. We found the sign to be positive in a patient whose hip was clinically and radiologically normal, and therefore investigated this in other patients. We confirmed that a medial shift of the mechanical axis of the leg below the hip may cause a positive Trendelenburg sign. This has not been previously described


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1411 - 1412
1 Nov 2017
Aarvold A Clarke NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 321 - 324
1 Mar 1998
Bar-On E Meyer S Harati G Porat S

Ultrasonography of the hip was performed sequentially by two different examiners in 75 infants. The ultrasound strips were reviewed twice by three paediatric orthopaedic surgeons and classified by the Graf method. The intraobserver and interobserver agreement between the interpretations was analysed using simple and weighted kappa coefficients calculated for agreement on the Graf classification and for grouping as normal (types 1A to 2A), and abnormal requiring treatment (types 2B to 4). When examining the same ultrasound strip, intraobserver agreement for the Graf classification was substantial (mean kappa 0.61), but interobserver agreement was only moderate (kappa 0.50). For the grouping into normal and abnormal, the mean kappa value for intraobserver agreement was 0.67 and for interobserver agreement 0.57. Because of the significant differences in agreement between normal and abnormal hips, we analysed a subgroup of those with at least one abnormal interpretation. Intraobserver agreement within this subgroup showed moderate reliability (kappa 0.41), but interobserver agreement was only fair (kappa 0.28). Interpretations of two different strips performed sequentially showed significantly lower agreement with an intraobserver kappa value of 0.29 and an interobserver value of 0.28. In the subgroup with at least one abnormal reading, the intraobserver kappa was 0.09 and the interobserver 0.1. Our findings suggest that both the technique of performing ultrasonography and the interpretation of the image may influence the result