Advertisement for orthosearch.org.uk
Results 821 - 840 of 1756
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 383 - 387
1 May 1989
Breek J Tan A van Thiel T Daantje C

We report the use of a free tendon graft in 70 patients to repair lesions of the capsuloligamentous complex of the metacarpophalangeal joint of the thumb. Of these 37 had a lesion of the ulnar collateral ligament, 18 of the radial collateral and 11 of the volar plate. Four patients had combined lesions. We outline our techniques and review 51 of the patients. Of those 47 (92%) were satisfied, and all but one had regained full stability. Pinch grip strength was normal in 48. About one-third of the patients had some loss of flexion/extension; this was seldom noticed by the patients and caused no significant disability. Free tendon graft reconstruction is indicated for severe fresh lesions, for old lesions with chronic disability and for lesions which have not responded to conservative management


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 388 - 390
1 Aug 1983
Paterson F Trickey E

A group of 40 patients with unstable knees due to a combination of a meniscal tear with a rupture of the anterior cruciate ligament was studied to assess the effects of treatment by meniscectomy alone. The results were assessed both subjectively and objectively, but emphasis was placed on the symptoms rather than the physical signs of instability. Meniscectomy alone cured the symptoms of instability in 22 of the patients and a further eight required no further surgical treatment; bucket-handle tears were associated with a good result and posterior-horn tears with a poor result. The remaining 10 patients later underwent an additional procedure to reconstruct the ligament because of persisting symptoms. It was concluded that in patients with this combined lesion the torn meniscus should be dealt with first. In young patients with a posterior-horn tear it would be justifiable to perform a ligamentous reconstruction at the same time as the meniscectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 430 - 436
1 Nov 1975
Jakob R Fowles JV Rang M Kassab MT

From an anatomical study and clinical review of fractures of the lateral humeral condyle in children, the following conclusions are drawn. The mechanism of injury is a violent varus force with the elbow in extension, the condyle being avulsed. by the lateral ligament and the extensor muscles. If the fracture is incomplete, with an intact hinge of pre-osseous cartilage medially, the fragment will not be displaced. If the fracture is complete the fragment may be displaced, and open reduction with internal fixation is mandatory. The results of open reduction more than three weeks after the fracture are no better than those of no treatment at all, and may kill the lateral condylar fragment by damaging its blood supply. The major problem of a neglected fracture is tardy ulnar nerve palsy; to avoid this, immediate anterior transposition of the nerve is recommended, operation for the fracture itself being of no benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 4 | Pages 788 - 792
1 Nov 1960
Miller JE

1. Pain in the elbow in javelin throwers is a common complaint. 2. The commonest type is caused by recurrent strain of the medial ligament. It develops in individuals who employ an incorrect throwing technique. The symptoms are cumulative, increasing with throwing and decreasing and resolving with rest. Treatment consists in improving the throwing technique. Local anaesthetic injected into the tender area produces complete but temporary relief. Hydrocortisone may produce partial or complete relief. 3. A second type of "javelin elbow" occurs in expert throwers and is the result of hyperextension of the elbow at the end of the throw, causing an injury to the tip of the olecranon. The symptoms are the result of a single throw or "mal-throw" and are completely disabling. They resolve with rest but tend to recur. If the tip of the olecranon is fractured excision of the fragment completely relieves the symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 807 - 810
1 Nov 1992
Emerson R Head W Peters P

We reviewed two similar groups of patients with medial osteoarthritis of the knee treated by unicompartmental arthroplasty. The group receiving an Oxford meniscal-bearing implant, with no medial release, showed significantly better mechanical alignment than that receiving a fixed-bearing implant. Under-correction, with its ominous mechanical implications, was much more common with the fixed-bearing design. Over-correction was rare and was seen in both designs about equally. Degenerative stenosis of the intercondylar notch was common and appeared to put the anterior cruciate ligament at risk of rupture, especially after correction of the varus deformity. We consider that postoperative leg alignment and soft-tissue balance after unicompartmental knee replacement are determined more by the implant design and the surgical technique than by any variation in soft-tissue contracture. Release of the medial collateral ligament is not necessary for realignment, but a generous notchplasty is often needed to allow normal anterior cruciate ligament function


Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives

The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic.

Methods

We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs.


Bone & Joint 360
Vol. 7, Issue 4 | Pages 19 - 22
1 Aug 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 618 - 624
1 Aug 1985
Watson M

Major ruptures of the rotator cuff were repaired in 89 patients over a six-year period, using an approach through the split deltoid muscle and the bed of the excised outer centimetre of the clavicle. Review of these patients showed that poor results were associated with larger cuff defects, with more pre-operative steroid injections and with pre-operative weakness of the deltoid muscle. A randomised prospective study showed that repair followed by splinting in abduction gave no better results than repair followed by resting the arm at the side. Excision of the coraco-acromial ligament was associated with worse results than leaving its divided halves in situ. Follow-up showed that the results continued to improve for two years after operation; their quality was maintained in patients less than 60 years old, but in those over 60 there was deterioration with time


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 173 - 179
1 Jan 1998
Race A Amis AA

We compared the ability of three different posterior cruciate ligament (PCL) reconstructions to restore normal anteroposterior laxity to the knee from 0 to 130° of knee flexion. Cadaver knees were tested intact, after PCL rupture or after bone-patellar tendon-bone grafting. Grafts were performed isometrically or with a single bundle representing the anatomical anterior PCL fibre bulk (aPC) or with a double bundle that added the posterior PCL fibre bulk (pPC). The grafts were tensioned to restore normal knee laxity at 60° of flexion, except for the pPC which was tensioned at 130°. The isometric graft led to overconstraint as the knee extended resulting in high graft tension in extension and excess laxity in flexion. The aPC graft matched normal laxity from 0 to 60° of flexion but was lax from 90 to 130° of flexion. Only the double-bundled graft could restore normal knee laxity across the full range of flexion


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 2 | Pages 239 - 245
1 May 1978
Bauze R Ardran G

Entire human cadaveric cervical spines with the basiocciput were subjected to load in a compression apparatus to simulate the clinical situation of forward dislocation. The movements were recorded by lateral cineradiography. Vertical load was measured by a potentiometric transmitter synchronised with each frame of the cineradiograph. The lower part of the spine was flexed and fixed, and the upper extended and free to move forward. Vertical compression then produced bilateral dislocation of the facets without fracture. If lateral tilt or axial rotation occurred as well, a unilateral dislocation was produced. The maximum vertical load was only 145 kilograms, and coincided with the rupture of the posterior ligament and capsule and the stripping of the anterior longitudinal ligament, but this occurred before dislocation. The low vertical load indicates a peculiar vulnerabiity of the cervical spine in this position and correlates well with the minor trauma often seen in association with forward dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 193 - 196
1 May 1975
Lunseth PA Chapman KW Frankel VH

The costo-clavicular ligament is always ruptured in dislocation at the sterno-clavicular joint. Anterior, superior or posterior displacement of the medial end of the clavicle may occur. Acute dislocation usually responds to conservative treatment and operation is seldom required. Chronic, or recurrent, dislocation may cause pain and disability on strenuous activity and necessitate surgical treatment. The operation of tenodesis of the subclavius tendon with capsulorrhaphy described by Burrows (1951) has been adopted. The intraarticular meniscus is often damaged and displaced, and may block reduction; its removal is then necessary. In addition, a threaded Steinmann pin transfixing the joint has been found useful to maintain the stability of reduction. The operation has been performed on five patients, four of whom had excellent results. The fifth patient disrupted the repair in a drinking bout shortly after the operation


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 2 | Pages 318 - 325
1 May 1961
Hnêvkovský O

1. Twelve children are described in whom gradual limitation of knee flexion developed, without previous injury or inflammation. 2. Clinical and histological investigation showed progressive fibrous degeneration of the vastus intermedius and rectus femoris. 3. As the patella showed signs of retarded development a particular form of myodysplasia, probably congenital, may be supposed. 4. Conservative treatment always failed to stop the progress of this disease. 5. Surgical treatment (Bennett's method or an elongation of the ligamental apparatus of the intermedius muscle) was carried out in ten cases and gave good permanent results. Flexion remained possible only to the extent obtained at operation; rehabilitation gave no further improvement. 6. In the opinion of the author, these cases occur more often than is generally believed, but they are recorded under a different diagnosis and consequently are not submitted to rational treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 4 | Pages 738 - 748
1 Nov 1959
MacKenzie IG

One hundred cases of Lambrinudi's arthrodesis are reviewed. The shortest follow-up was one year. and the longest twenty-seven years. Thirty-seven per cent were successful. Nineteen per cent were failures; many of these were associated with faulty technique, and one method of operation which gives good results is described. Success is likely if there is a balance of power between the dorsiflexors and plantarflexors of the ankle, especially if there is some fixed equinus before operation. Success is less likely when the operation is done for a flail foot. In such circumstances arthrodesis of the ankle may have to be considered subsequently for instability of the lateral ligament, recurrence of dropfoot, or arthritis which may develop in the more active patients. Age in itself is no bar to success, but pseudarthrosis is more likely to occur in patients over the age of twenty


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 235 - 239
1 Mar 1997
Takahashi T Wada Y Yamamoto H

We measured the pressure distribution across the tibiofemoral and patellofemoral joints during total knee arthroplasty (TKA) using Fuji pressure-sensitive film (Prescale) in 51 patients (63 joints) comparing the results with those in 21 patients in whom Prescale was not used. We classified the stress-distribution patterns in the tibiofemoral joints into four types: normal, varus-valgus instability, rotational malalignment, and a combination of instability and malrotation. The medial ligaments were then released according to the information obtained from these patterns. The conformity ratio of the contact area between repeated trials was 87.0%. Pressure distribution across the patellofemoral joints was also considered. There was a significant decrease in the mean valgus stress angle in the Prescale group compared with the control group (p < 0.01). Release of the lateral retinaculum according to the results showed no significant differences in subluxation of the patella between the released group and the group which did not appear to need this procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 884 - 889
1 Nov 1995
Stiehl J Komistek R Dennis D Paxson R Hoff W

We used fluoroscopy to study the kinematics of the knee in 47 patients with total knee arthroplasty (TKA) and four control subjects with normal knees while performing a single-leg deep-knee bend. The videos were analysed using still photographs taken at 5 degrees increments of flexion. Femorotibial contact points, patellar ligament rotation, and patellar rotation were calculated from each image. Maximum weight-bearing flexion was determined for each knee. Compared with the control group, posterior-cruciate-retaining TKA did not reproduce normal knee kinematics in any case, but showed a starting point posterior to the tibial midline which translated anteriorly with flexion. The curves from successive knee bends could not be consistently reproduced. Under weight-bearing conditions, the maximum flexion for any PCR TKA was 98 degrees and several patients could not flex beyond 70 degrees


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 617 - 621
1 May 2018
Uehara M Takahashi J Ikegami S Kuraishi S Fukui D Imamura H Okada K Kato H

Aims

Although we often encounter patients with an aortic aneurysm who also have diffuse idiopathic skeletal hyperostosis (DISH), there are no reports to date of an association between these two conditions and the pathogenesis of DISH remains unknown. This study therefore evaluated the prevalence of DISH in patients with a thoracic aortic aneurysm (AA).

Patients and Methods

The medical records of 298 patients who underwent CT scans for a diagnosis of an AA or following high-energy trauma were retrospectively examined. A total of 204 patients underwent surgery for an AA and 94 had a high-energy injury and formed the non-AA group. The prevalence of DISH was assessed on CT scans of the chest and abdomen and the relationship between DISH and AA by comparison between the AA and non-AA groups.


Bone & Joint 360
Vol. 7, Issue 5 | Pages 13 - 16
1 Oct 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 902 - 906
1 Sep 1999
Ochi M Iwasa J Uchio Y Adachi N Sumen Y

We examined whether somatosensory evoked potentials (SEPs) were detectable after direct electrical stimulation of injured, reconstructed and normal anterior cruciate ligaments (ACL) during arthroscopy under general anaesthesia. We investigated the position sense of the knee before and after reconstruction and the correlation between the SEP and instability. We found detectable SEPs in all ligaments which had been reconstructed with autogenous semitendinosus and gracilis tendons over the past 18 months as well as in all cases of the normal group. The SEP was detectable in only 15 out of 32 cases in the injured group, although the voltages in the injured group were significantly lower than those of the controls. This was not the case in the reconstructed group. The postoperative position sense in 17 knees improved significantly, but there was no correlation between it and the voltage. The voltage of stable knees was significantly higher than that of the unstable joints. Our findings showed that sensory reinnervation occurred in the reconstructed human ACL and was closely related to the function of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 605 - 613
1 Jul 1992
Amis A Camburn M Kempson S Radford W Stead A

We excised the anterior cruciate ligament from the left stifle of 24 sheep and replaced it by a polyester fibre implant routed 'over the top' of the femoral condyle and fixed, using grommets and screws. All the joints were sound, and the animals moved normally until they were killed at six, 12 and 24 months after operation. We found that the implants were always covered by host tissue, which matured into bundles with a histological appearance similar to the natural ligament. The implants were joined to the bones by organised fibrous tissue and there was no anchorage loosening. There was no synovitis, but the operated joints showed progressive cartilage degeneration. The reconstructed joints became less stable immediately after operation, but regained normal stability as the neoligaments developed. The neoligaments lost strength with time, despite tissue ingrowth. The good functional, biomechanical, and histological results justify clinical trials of this type of implant


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 271 - 284
1 Mar 2018
Hexter AT Thangarajah T Blunn G Haddad FS

Aims

The success of anterior cruciate ligament reconstruction (ACLR) depends on osseointegration at the graft-tunnel interface and intra-articular ligamentization. Our aim was to conduct a systematic review of clinical and preclinical studies that evaluated biological augmentation of graft healing in ACLR.

Materials and Methods

In all, 1879 studies were identified across three databases. Following assessment against strict criteria, 112 studies were included (20 clinical studies; 92 animal studies).