Bone-marrow oedema syndrome (BMOS) of the hip gives a characteristic MRI pattern, in association with severe pain, non-specific focal loss of radiological density and a positive bone scan. In our MRI-controlled study, nine patients with non-traumatic BMOS in ten hips all had core decompression. Bone-marrow pressure measurements and intraosseous venography in five cases showed pathological values. All patients had immediate relief of pain, with return of MRI signals to normal after three months. Regular review was continued for at least 24 months with serial clinical radiological and MRI assessment. At a mean follow-up of 33 months all patients remained free of pain with normal radiographs and MR scans. The
We compared the effects of continuous passive motion with those of intermittent active motion on the results of the resurfacing with autogenous periosteal grafts of full-thickness defects on the articular surface of rabbit patellae. Of 45 rabbits with defects, 30 received grafts. Fifteen of these had continuous passive motion for two weeks and intermittent active motion for four weeks; the other 15 had intermittent active motion for six weeks. In 15 the defects were not grafted (control group) and they had intermittent active motion for six weeks. Ten more rabbits had a sham operation. Six weeks after surgery, the results were assessed by the gross appearance,
Porous blocks of calcium hydroxyapatite ceramic were evaluated as delivery systems for the sustained release of antibiotics. We tested gentamicin sulphate, cefoperazone sodium, and flomoxef sodium in powder form placed in a cylindrical cavity in calcium hydroxyapatite blocks, using in vitro studies of elution and in vivo studies in rats. Gentamicin sulphate gave a maximum concentration within the first week, which gradually decreased but was still effective at 12 weeks, when 70% of the antibiotic had been released. Even at this stage the antibiotic concentration from a 75 mg dose was five times the minimum inhibitory concentration for staphylococci. In the in vivo studies the release of gentamicin sulphate into the normal bone of rats was at similar rates and levels. The bacteriocidal activity of the drugs was not affected by packing into calcium hydroxyapatite ceramic and the blocks were completely biocompatible on
Aims
Patients and Methods
The clinical, radiographic and pathological features of eighty-eight cases of
The clinical records, radiographs and histopathological material of all forty-one patients recorded as suffering from fibrosarcoma of bone in the Swedish Cancer Registry for the years 1958 to 1968 have been analysed; in addition, four cases were found on
1. Fifty cases of fibrosarcoma from the records of the Bristol Bone Tumour Registry are reviewed. They present further clinical and radiological evidence supporting the concept of fibrosarcoma as a distinctive type of bone tumour. 2. The radiographic appearances have often been those ofan osteolytic lesion totally enclosed by reactive subperiosteal new bone. 3. Included in the group are eleven cases with Paget's osteitis deformans, three cases in which the sarcoma was associated with calcified cartilage and one case that is regarded as a post-irradiation sarcoma. 4. Several clinically differing modes of presentation are described. 5. Fibrosarcoma in bone has often been said to be "central" or "medullary" but because the present series includes tumours with eccentric origin and unilateral cortical destruction this description is inappropriate. 6. The
Composites of chondrocytes and polymerised fibrin were supplemented with insulin-like growth factor-I (IGF-I) during the arthroscopic repair of full-thickness cartilage defects in a model of extensive loss of cartilage in horses. Repairs facilitated with IGF-I and chondrocyte-fibrin composites, or control defects treated with chondrocyte-fibrin composites alone, were compared before death by the clinical appearance and repeated analysis of synovial fluid, and at termination eight months after surgery by tissue morphology, collagen typing, and biochemical assays. The structure of cartilage was evaluated
The
We studied the mechanical and biochemical properties of articular cartilage from 22 osteoarthritic femoral heads obtained at operation and 97 femoral heads obtained at autopsy. Cartilage from the zenith and from the antero-inferior aspect of each head was tested both in tension and in compression. Water content, swelling ability and proteoglycan content were measured, the cartilage was examined
Ceramics have many properties which might make them suitable alternatives to bone grafts. This present study was done to find a suitable biodegradable porous ceramic for human bone replacement. Three different porous ceramics (calcium aluminate, calcium hydroxyapatite and tricalcium phosphate), with interlinked pores of two size ranges (150 to 210 micron), were implanted into the skulls of rats and rabbits for up to six months; the interaction with surrounding bone, which is virtually devoid of bone marrow, was then assessed. The ceramics caused no adverse biological response. Tissue ingrowth into pores throughout the implant was seen in all three types and in both pore sizes of ceramic, but the density of the penetrating tissue was far less for calcium aluminate than for calcium hydroxyapatite or tricalcium phosphate. For each type of ceramic, the soft-tissue ingrowth was more dense with the larger pore size, and with a longer period of implantation. Bone ingrowth was not usually seen within the pores of any ceramic. There were no differences in the
Recent surveys have shown that idiopathic structural scoliosis of mild degree is generally not progressive. We will propose a mechanism which may be responsible for deterioration in the few. It has been observed that the spinal cord, although displaced towards the concavity, does not rotate in company with the vertebrae, thus exposing the emerging nerve roots to the effects of traction and possibly of entrapment. We suggest that progression occurs when the neuraxis is unable to adjust to the change in the anatomy of vertebral column. Our proposition is based upon our findings in a complete spinal column obtained from a baby with structural scoliosis. Support is provided by intercostal angiography, and by observations upon normal anatomy, the pathological anatomy of mature scoliotic spines and the anatomy of contrived scoliosis in normal spines. Although our
1. In two-month-old rabbits the femoral heads were made necrotic by transecting the ligament of the femoral head and applying a ligature around the femoral neck. The animals were killed at different periods, from six hours to twenty-one weeks after the operation. The changes in the femoral heads were studied
1. The use of a protein-free synthetic medium has provided a new technical approach to the study of fracture healing in vitro. 2. The tibiae of fourteen-day embryonic chicks were cut in half in the middle of the shaft, the fragments were placed in apposition and the explants grown in vitro for up to sixteen days. The process of bone repair was studied by means of
Puppies in the second half of their growing period have been observed for one and a half to four and a half months after creation of a superficial femoral arteriovenous fistula on the right side. From measurements of the whole bone and from microradiographic and tetracycline-fluorophore studies of the diaphysial bone, it is believed that the following statistically significant phenomena may be attributed to the influence of the arteriovenous fistula. 1. All bones distal to the fistula are influenced in their growth. The tibia and metatarsals become heavier and larger, but retain normal shape. Although stimulation of longitudinal growth is small, it is significant for the tibiae and nearly significant for the femora in these short-term experiments. 2. The
1 . The extensor digitorum longus of the rabbit was partly denervated by section of one of its two nerve branches and examined
To assess the diagnostic value of C-reactive protein (CRP), leucocyte count (LC), and erythrocyte sedimentation rate (ESR) in late fracture-related infection (FRI). PubMed, Embase, and Cochrane databases were searched focusing on the diagnostic value of CRP, LC, and ESR in late FRI. Sensitivity and specificity combinations were extracted for each marker. Average estimates were obtained using bivariate mixed effects models.Aims
Materials and Methods
We have investigated the significance of local recurrence on survival in 173 patients with localised soft-tissue sarcomas of the limbs and of the trunk. The overall survival rates at five and ten years were 75.2% and 68.0%, respectively. After definitive surgery at our hospitals, there was local recurrence in 25 patients (14.5%). After inadequate operations elsewhere, there was a higher incidence of late local recurrence (28.3%), in comparison with those with primary tumours treated by us (9.0%), or patients referred to us immediately after inadequate surgery elsewhere (10.2%). Because of small numbers these differences in the survival rates were not statistically significantly different. Univariate survival analysis showed that local recurrence after definitive surgery (p = 0.006) together with the
We analysed revised Mathys isoelastic polyacetal femoral stems with stainless-steel heads and polyethylene acetabular cups from eight patients in order to differentiate various types of particle of wear debris. Loosening of isoelastic femoral stems is associated with the formation of polyacetal wear particles as well as those of polyethylene and metal. All three types of particle were isolated simultaneously by tissue digestion followed by sucrose gradient centrifugation. Polyacetal particles were either elongated, ranging from 10 to 150 μm in size, or shred-like and up to 100 μm in size. Polyethylene particles were elongated or granules, and were typically submicron or micronsized. Polyacetal and polyethylene polymer particles were differentiated by the presence of BaSO. 4. , which is added as a radiopaque agent to polyacetal but not to polyethylene. This was easily detectable by back-scattered SEM analysis and verified by energy dispersive x-ray analysis. Two types of foreign-body giant cell (FBGC) were recognised in the