Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the long-term follow-up. Two patients, each with one elbow prosthesis, have been lost to follow-up and three males who are still living (two with PTOA, one with juvenile RA) had their prosthesis removed before ten years had elapsed. The remaining 32 patients (28 RA, 4 PTOA) with 36 GSB III elbows were examined clinically and radiologically after a mean period of 13.5 years. Pain was considerably reduced in 91.6%. Mobility was increased by 37° in those with RA and by 67° in those with PTOA. There were three cases of aseptic loosening and three of deep infection. The main complication was disassembly of the prosthetic component in nine elbows (13.8%). This last group included two patients with postoperative fractures unrelated to the operative technique and one with neuropathic arthritis. Ulnar neuritis occurred in two patients. Since 87.7% of all the GSB III prostheses implanted in this period remained in situ, our results are comparable with those for hip and knee arthroplasty.
The use of impacted, morsellised bone grafts has become popular in revision total hip arthroplasty (THA). The initial stability of the reconstruction and the effectiveness of any subsequent process of revitalisation and incorporation will depend on the mechanical integrity of the graft. Our aim in this study was to document the time-dependent mechanical properties of the morsellised graft. This information is useful in clinical application of the graft, in studies of migration of the implant and in the design of the joint. We used 16 specimens of impacted, morsellised cancellous bone from the sternum of goats to assess the mechanical properties by confined compression creep tests. Consideration of the graft material as a porous, permeable solid, filled with fluid, allowed determination of the compressive modulus of the matrix, and its permeability to fluid flow. In all specimens the compression tests showed large, irreversible deformations, caused by flow-independent creep behaviour as a result of rolling and sliding of the bone chips. The mean permeability was 8.82 *10−12 m4/Ns (SD 43%), and the compressive modulus was 38.7 MPa (SD 34%). No correlation was found between the apparent density and the permeability or between the apparent density and the compressive modulus. The irreversible deformations in the graft could be captured by a creep law, for which the parameters were quantified. We conclude that in clinical use the graft is bound to be subject to permanent deformation after operation. The permeability of the material is relatively high compared with, for example, human cartilage. The confined compression modulus is relatively low compared with cancellous bone of the same apparent density. Designs of prostheses used in revision surgery must accommodate the viscoelastic and permanent deformations in the graft without causing loosening at the interface.
We immobilised the right hindlimbs of six-month-old female Wistar rats for four weeks using a biplanar external fixation bridging the knee. The untreated left limbs served as a control group. An additional group of rats was allowed to recover for four weeks after removal of the frame. Immobilisation caused reduction in the wet weights of approximately 50% in the gastrocnemius, quadriceps, soleus and plantaris muscles; this was not restored completely after remobilisation. There was an increase in the activity of acid phosphatase of approximately 85% in the gastrocnemius and quadriceps muscles whereas that of creatine phosphokinase was reduced by about 40%. These values returned to nearly normal after remobilisation. Histological and ultrastructural examination showed a marked myopathy of the gastrocnemius muscle after immobilisation although the morphology was largely restored after remobilisation. We conclude that after four weeks of remobilisation, hind-limb muscles do not return to preimmobilisation weights, although biochemical activities and ultrastructural appearance are largely restored.
All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.
We examined whether somatosensory evoked potentials (SEPs) were detectable after direct electrical stimulation of injured, reconstructed and normal anterior cruciate ligaments (ACL) during arthroscopy under general anaesthesia. We investigated the position sense of the knee before and after reconstruction and the correlation between the SEP and instability. We found detectable SEPs in all ligaments which had been reconstructed with autogenous semitendinosus and gracilis tendons over the past 18 months as well as in all cases of the normal group. The SEP was detectable in only 15 out of 32 cases in the injured group, although the voltages in the injured group were significantly lower than those of the controls. This was not the case in the reconstructed group. The postoperative position sense in 17 knees improved significantly, but there was no correlation between it and the voltage. The voltage of stable knees was significantly higher than that of the unstable joints. Our findings showed that sensory reinnervation occurred in the reconstructed human ACL and was closely related to the function of the knee.
Heritable thrombophilic disorders have been proposed as one of the causes for Legg-Calvé-Perthes disease. A total of 62 patients diagnosed with this disease between 1988 and 1997 and 50 controls were screened for thrombophilia. The incidence and relationship of thrombophilia to the severity of the disease were evaluated. One patient and none of the controls had protein S deficiency. One of the control group and one of the patients had protein C deficiency with the latter child also having a combined deficiency with a mutant factor V gene. The number of children with a mutant factor V gene, protein C deficiency, who were homozygous for the C 677T polymorphism of methylenetetra-hydrofolate reductase or were heterozygous for mutant We found no correlation between thrombophilia and the extent of the disease. The most common risk factors for arteriovenous thromboembolism showed no statistical significance in our patients compared with the control group or with the general population. These data do not confirm an aetiological role for thrombophilia in Perthes’ disease.
Six major and seven minor diagnostic criteria have been developed by the Japanese Investigation Committee for osteonecrosis of the femoral head (ONFH). We have carried out a multicentre study to clarify these. We studied prospectively 277 hips in 222 patients, from six hospitals, who had ONFH and other hip pathology and from whom histological material was available. We identified five criteria with high specificity: 1) collapse of the femoral head without narrowing of the joint space or acetabular abnormality on radiographs, including the crescent sign; 2) demarcating sclerosis in the femoral head without narrowing or acetabular abnormality; 3) a ‘cold-in-hot’ appearance on the bone scan; 4) a low-intensity band on T1-weighted images (band pattern); and 5) evidence of trabecular and marrow necrosis on histological examination. With any combination of two of these criteria, the sensitivity and specificity of the diagnosis were 91% and 99%, respectively.
We reviewed histologically the incidence and pathogenesis of the deposition of calcium pyrophosphate dihydrate (CPPD) crystals in the pseudocapsule, femoral and acetabular membranes and periprosthetic tissue at revision of 789 cases of failed total hip replacement. In 13, periprosthetic tissues were found to have deposits of CPPD crystals in areas of cartilaginous metaplasia; four also showed evidence of localised deposition of amyloid. None of the patients had a history of chondrocalcinosis in the hip or other joints. Cartilaginous metaplasia and other changes in periprosthetic tissues may predispose to the deposition of CPPD and associated localised amyloid.
We reviewed 26 patients with 34 shoulders treated by the inferior capsular shift operation for inferior and multidirectional instability. The mean follow-up was 8.3 years. In total, 12 shoulders showed voluntary subluxation. Eight operations used an anterior and posterior approach, 11 were by the posterior route, and 15 shoulders had an anterior approach. In 30 shoulders (85%) the outcome was satisfactory and 20 (59%) scored good or excellent results on the Rowe system. Instability had recurred in nine shoulders (26%) from three months to three years after the operation. Six of the 12 shoulders with voluntary subluxation (50%) had recurrence, as against three of the other 22 (14%), a statistically significant difference. The operation is therefore not indicated for voluntary subluxation. The 19 shoulders which had been assessed in 1987 at a mean of 3.5 years after surgery, were also reviewed in 1995 and found to have no significant changes in instability or Rowe score. This shows that the capsular shift appeared to have maintained its tension over an eight-year period. After the use of a posterior approach, 64% of the shoulders showed a posterolateral defect on radiographs of the humerus.
We studied 45 patients with 46 fractures of the scaphoid who presented sequentially over a period of 21 months. MRI enabled us to relate the pattern of the fracture to the blood supply of the scaphoid. Serial MRI studies of the four main patterns showed that each followed a constant sequence during healing and failure to progress normally predicted nonunion.
Recent studies of the fibroblast growth factor receptor 3 (FGFR3) gene have established that achondroplasia and hypochondroplasia are allelic disorders of different mutations. To determine whether the genotype could be distinguished on the basis of the phenotype, we analysed height, arm span, and skeletal radiographs from 23 patients with achondroplasia and the G380R mutation of FGFR3 and eight with hypochondroplasia and the N540K mutation. Both conditions share the classical pathological features of micromelic short stature, reduced or unchanged interpedicular distances in the lumbar spine, disproportionately long fibulae, and squared and shortened pelvic ilia. These were significantly more severe in the G380R patients than in the N540K patients. Our findings have shown a firm statistical correlation between the genotype and the phenotype, although there were a few exceptional cases in which there was phenotypic overlap between the two conditions.
We have treated 16 patients with recurrent complex elbow instability using a hinged external fixator. All patients had instability, dislocation or subluxation of the ulnohumeral joint. The injuries were open in eight patients and were associated with 20 other fractures and five peripheral nerve injuries. Two patients had received initial treatment from us; 14 had previously had a mean of 2.1 unsuccessful surgical procedures (1 to 6). The fixator was applied at a mean of 4.8 weeks (0 to 9) after the injury and remained on the elbow for a mean of 8.5 weeks (6 to 11). After treatment we found the mean range of flexion-extension to be 105° (65 to 140). At a final follow-up of 23 months (14 to 40), the mean Morrey score was 84 (49 to 96): this translated into one poor, three fair, ten good and two excellent results. Complications included one fractured humeral pin, one temporary palsy of the radial nerve, one recurrent instability, one wound infection, one severe pin-track infection and one patient with reflex sympathetic dystrophy. Although technically demanding, the use of the fixator is an important advance in the management of recurrent complex elbow instability after failure of conventional treatment.
We describe a new technique, known as coregistration imaging, which superimposes 99mTc isotope bone scans on to plain radiographs. We used the technique selectively in cases in which the nuclear medicine physician, who reported the isotope scan, had difficulty in localising the anatomical site of the abnormality. In the forefoot, coregistration of isotope scans did not help to localise pathology; the scan alone gave sufficient detail. In 17 patients with pain in the hind- and midfoot, isotope scanning identified eight sites of abnormality in those with normal radiographs. In those with more than one abnormality on plain radiographs the isotope scan eliminated 12 sites of suspicion. Coregistration of the images significantly increased the certainty of localisation of disease (p <
0.001). We recommend the selective use of coregistration scanning as a useful technique for investigating patients with pain in the foot and ankle.
Little is known about the tissue reactions to various implant materials which coincide with an inflammatory reaction. We used the avridine arthritis rat model to evaluate the tissue response in the synovial, interstitial and subcutaneous tissues after implant insertion. Quantitative immunohistochemistry showed that normal joint synovial tissue is dominated by ED2-positive resident macrophages. Polyethylene implants induced a much stronger foreign-body reaction than titanium implants, as measured by the number of interfacial ED1-positive macrophages. The tissue response to titanium and polyethylene was also vastly different in arthritic synovial tissue compared with control tissue. It is likely that these biomaterials interact differently with inflammatory cells or intermediary compounds. It may be that arthritic synovial tissue produces reactive oxygen intermediates (free radicals) with which titanium has a unique anti-inflammatory interaction in vitro.
We used the Ilizarov method in seven patients with severe congenital radial club hands who had had previous wrist surgery, to correct residual shortening and bowing of the ulna together with recurrent wrist deformity. The mean age at operation was 6.5 years. The mean ulnar shortening was 5.3 cm and the mean angular deformity 42°. The mean length gained was 51% of the original ulna. The mean healing index was 46.9 days (29.8 to 64.0). The ratio of the length of the lengthened ulna to the normal side improved on average from 64% to 95%. The angular deformity was initially completely corrected in six out of seven patients. The length ratio, however, decreased to 83% at the final follow-up. In four patients, the angular deformity partially recurred. We recommend correction of congenital radial club hand by staged procedures. The first is centralisation and stabilisation of the wrist and the second lengthening of the ulna and correction of the angular deformity using the Ilizarov method.