To describe and analyze the mid-term functional outcomes of a large series of patients who underwent the Hoffer procedure for brachial plexus birth palsy (BPBP). All patients who underwent the Hoffer procedure with minimum two-year follow-up were retrospectively reviewed. Active shoulder range of movement (ROM), aggregate modified Mallet classification scores, Hospital for Sick Children Active Movement Scale (AMS) scores, and/or Toronto Test Scores were used to assess functional outcomes. Subgroup analysis based on age and level of injury was performed. Risk factors for subsequent humeral derotational osteotomy and other complications were also assessed. A total of 107 patients, average age 3.9 years (1.6 to 13) and 59% female, were included in the study with mean 68 months (24 to 194) follow-up.Aims
Methods
Ceramics have many properties which might make them suitable alternatives to bone grafts. This present study was done to find a suitable biodegradable porous ceramic for human bone replacement. Three different porous ceramics (calcium aluminate, calcium hydroxyapatite and tricalcium phosphate), with interlinked pores of two size ranges (150 to 210 micron), were implanted into the skulls of rats and rabbits for up to six months; the interaction with surrounding bone, which is virtually devoid of bone marrow, was then assessed. The ceramics caused no adverse biological response. Tissue ingrowth into pores throughout the implant was seen in all three types and in both pore sizes of ceramic, but the density of the penetrating tissue was far less for calcium aluminate than for calcium hydroxyapatite or tricalcium phosphate. For each type of ceramic, the
An experimental study is reported of fracture healing in the femora of 36 Beagle dogs, comparing the results of using stainless steel plates with those of using less rigid titanium alloy plates. The alloy plates led to the appearance of a small amount of periosteal callus without any histological evidence of fracture instability, thus allowing the radiological assessment of fracture union. This also produced less bone loss during the remodelling phase. Radiological measurements 24 weeks after osteotomy showed cortical thickness to be reduced by six per cent under titanium alloy and by 19 per cent under stainless steel, while histological measurements showed a total bone loss of 3.7 per cent under titanium alloy and of 11 per cent under stainless steel plates. Removal of the titanium alloy plates after eight weeks followed by a recovery period of 16 weeks produced an increase of cortical thickness of 69 per cent and a gain in total bone mass of 30 per cent. Titanium alloy plates also produced less
Serial arterial blood-gas analyses showed a phase of primary hypoxaemia in thirty-two out of fifty fracture patients (64 per cent) without head, chest or abdominal injury. The incidence was greater in those with shaft fractures of the femur or tibia or both, than in those with fractured hips, and was related to the severity of injury and the nature of the accident. Most affected subjects were already hypoxaemic on admission to hospital: the arterial PO. 2. commonly fell to between 60 and 70 millimetres of mercury, and the episode generally lasted a few days. The hypoxaemia was generally subclinical but four patients developed mild clinical fat embolism. Early hypoxaemia was not found in six patients admitted with only
1. Paralytic dislocation of the hip in spina bifida generally requires reduction and iliopsoas transfer. The muscle transfer ensures that the hip remains reduced, lessens the need for calipers and prevents progressive flexion deformity. In addition, varus and rotation osteotomy of the femur and innominate osteotomy are sometimes required. Varus and rotation osteotomy alone is indicated if the psoas is not strong enough for transfer. The age for reduction of dislocated hips and muscle transfer has been reduced to eight months as experience and confidence has been gained. 2. Flexion deformity is best prevented by early iliopsoas transfer. An anterior release operation is occasionally indicated when there is flexion deformity and a weak psoas muscle. This procedure, alone or supplemented by extension osteotomy, may be necessary to correct severe flexion deformity in children seen late. 3. Lateral rotation deformity of the hip may be caused by unbalanced iliopsoas action or the unbalanced action, or contracture, of the short lateral rotator muscles. If the deformity is sufficient to make the gait bizarre, or if it is difficult to fit a caliper, then
Distraction osteogenesis (callotasis) has been widely used in patients with limb-length inequality or massive bone defects. This procedure, however, may be associated with a high incidence of physical and psychosocial complications. Callotasis telescoping on a locked intramedullary nail has been used to shorten the period of external fixation. Little attention has been given to the use of locked intramedullary nails in the treatment of complications after callotasis. Between 1990 and 1999, we used locked intramedullary nailing in 27 patients for the treatment of complications after distraction osteogenesis. There were 17 men and ten women with a mean age of 33.2 years (16 to 66). The nail was inserted at a mean of 3.4 weeks (0 to 15) after removal of the external fixator. Simultaneous autogenous bone grafting and
There is little information about the effects of extracorporeal shock-wave about application the effects (ESWA) of on normal bone physiology. We have therefore investigated the effects of ESWA on intact distal rabbit femora in vivo. The animals received 1500 shock-wave pulses each of different energy flux densities (EFD) on either the left or right femur or remained untreated. The effects were studied by bone scintigraphy, MRI and histopathological examination. Ten days after ESWA (0.5 mJ/mm. 2. and 0.9 mJ/mm. 2. EFD), local blood flow and bone metabolism were decreased, but were increased 28 days after ESWA (0.9 mJ/mm. 2. ). One day after ESWA with 0.9 mJ/mm. 2. EFD but not with 0.5 mJ/mm. 2. , there were signs of
1. A series of 106 central slip injuries has been reviewed. 2. Although the boutonnière deformity in many cases may be no more than a cosmetic defect, this survey has shown that in some instances it can constitute a slowly progressive lesion, with considerable disability and gross deformity of a digit. 3. Conservative treatment seems to be superior to operation, at least in those patients seen within six weeks of injury. Treatment by splintage alone yielded in this series a 75 per cent success rate, whereas operation showed only 50 per cent success. 4. When a sizeable fragment of bone has been avulsed from the middle phalanx, suture of the fragment in position is indicated and gives remarkably satisfactory results. 5. Injuries with
Many analyses of the geometric arrangement of trabeculae in the proximal end of the femur have accepted and perpetuated the theories of Ward (1838), Culmann (1866) and Meyer (1867), and have contributed to the belief that the structure of the femoral neck embodies mechanical principles which are foreign to bony formations elsewhere. This isolated departure from the normal pattern of skeletal behaviour is considered to be most unlikely, and an attempt has been made to show that the structure of the femoral head and neck departs but little from the normal anatomy of the long bone. From a developmental point of view, the proximal end of the human femur is believed, in its simplest interpretation, to represent an upward continuation of the original shaft which has undergone rotation and expansion. The cancellous arrangements of the internal weight-bearing system are likewise believed to represent the expanded and rotated lamellae of the neck as they are presented radiologically or on coronal section. The forces acting upon the proximal end of the femur are considered to be mainly compressive in nature, and both crane and street-lamp bracket theories have therefore been rejected. The spiral conformity of the proximal end of the femur has been related to the spiral disposition of the
1. Although fractures and dislocations of the talus have been described since 1608 the rarity of the more severe and complicated injuries has meant a dearth of accurate descriptions or classification in the literature. 2. A series of 228 injuries of the talus occurring in members of the Royal Air Force between 1940 and 1943 has been reviewed. 3. A simple but comprehensive classification of injuries of the talus is presented, together with a review of the pathological anatomy, clinical features, and methods of treatment. The importance of distinguishing between fractures and fracture-dislocations, and of watching carefully for displacements of the subtalar joint, is emphasised. 4. The important complicationsâinfection, avascular necrosis and traumatic arthritis of the ankle or subtalar jointâare discussed. Infection may be the result of a compound injury, or may follow sloughing of the skin stretched over a displaced talus. Early reduction is, therefore, of great urgency in closed injuries. Avascular necrosis of the talus occurs in gross injuries when all or most of the
The primary source for the blood supply of the head of the femur is the deep branch of the medial femoral circumflex artery (MFCA). In posterior approaches to the hip and pelvis the short external rotators are often divided. This can damage the deep branch and interfere with perfusion of the head. We describe the anatomy of the MFCA and its branches based on dissections of 24 cadaver hips after injection of neoprene-latex into the femoral or internal iliac arteries. The course of the deep branch of the MFCA was constant in its extracapsular segment. In all cases there was a trochanteric branch at the proximal border of quadratus femoris spreading on to the lateral aspect of the greater trochanter. This branch marks the level of the tendon of obturator externus, which is crossed posteriorly by the deep branch of the MFCA. As the deep branch travels superiorly, it crosses anterior to the conjoint tendon of gemellus inferior, obturator internus and gemellus superior. It then perforates the joint capsule at the level of gemellus superior. In its intracapsular segment it runs along the posterosuperior aspect of the neck of the femur dividing into two to four subsynovial retinacular vessels. We demonstrated that obturator externus protected the deep branch of the MFCA from being disrupted or stretched during dislocation of the hip in any direction after serial release of all other
There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship.Aim
Methods
The primary aim of the study was to compare the knee-specific functional outcome of robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty (mTKA) for the management of isolated medial compartment osteoarthritis. Secondary aims were to compare length of hospital stay, general health improvement, and satisfaction between rUKA and mTKA. A powered (1:3 ratio) cohort study was performed. A total of 30 patients undergoing rUKA were propensity score matched to 90 patients undergoing mTKA for isolated medial compartment arthritis. Patients were matched for age, sex, body mass index (BMI), and preoperative function. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were collected preoperatively and six months postoperatively. The Forgotten Joint Score (FJS) and patient satisfaction were collected six months postoperatively. Length of hospital stay was also recorded.Aims
Methods
We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed. All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.Aims
Methods
We describe the results of a prospective study of 28 children with spastic diplegia and in-toed gait, who had bilateral femoral derotation osteotomies undertaken at either the proximal intertrochanteric or the distal supracondylar level of the femur. Preoperative clinical evaluation and three-dimensional movement analysis determined any additional
We describe a method of partial limb salvage for the treatment of large primary malignant tumours of the arm. The tumour-bearing area is resected as a cylindrical segment and the distal arm is then replanted with the necessary shortening. The method is suitable for stage-IIB tumours with or without neurovascular involvement which, because of their extent, could otherwise be adequately treated only by amputation. From 1987 to 1992 we used this method in 12 patients with primary malignant bone or
We describe a management strategy for upper- and lower-limb fractures with associated arterial injury and report the results in 113 cases treated over a period of 18 years. Primary amputation was performed in 23 patients and of those who underwent primary vascular repair, 27 needed secondary amputation, two-thirds of them within a week of the injury. Of those requiring secondary amputation, 51.8% had ischaemia exceeding six hours, 81.4% had severe