The Oxford knee score (OKS) is a validated and
widely accepted disease-specific patient-reported outcome measure,
but there is limited evidence regarding any long-term trends in
the score. We reviewed 5600 individual OKS questionnaires (1547
patients) from a prospectively-collected knee replacement database,
to determine the trends in OKS over a ten-year period following
total knee replacement. The mean OKS pre-operatively was 19.5 (95%
confidence interval (CI) 18.8 to 20.2). The maximum post-operative
OKS was observed at two years (mean score 34.4 (95% CI 33.7 to 35.2)),
following which a gradual but significant decline was observed through
to the ten-year assessment (mean score 30.1 (95% CI 29.1 to 31.1))
(p <
0.001). A similar trend was observed for most of the individual
OKS components (p <
0.001). Kneeling ability initially improved
in the first year but was then followed by rapid deterioration (p
<
0.001). Pain severity exhibited the greatest improvement, although
residual pain was reported in over two-thirds of patients post-operatively,
and peak improvement in the night pain component did not occur until
year four. Post-operative OKS was lower for women (p <
0.001),
those aged <
60 years (p <
0.003) and those with a body mass
index >
35 kg/m2 (p <
0.014), although similar changes
in scores were observed. This information may assist surgeons in
advising patients of their expected outcomes, as well as providing
a comparative benchmark for evaluating longer-term outcomes following
knee replacement. Cite this article:
The April 2013 Wrist &
Hand Roundup360 looks at: whether botox is just for Hollywood; supercharging nerve repairs; YouTube research; options for Keinbock’s disease; volar plates; driving and plasters; symptomatic radial malunion; and MRI and acute scaphoid fractures.
The aim of this study was to perform a cost–utility
analysis of total hip (THR) and knee replacement (TKR). Arthritis is
a disabling condition that leads to long-term deterioration in quality
of life. Total joint replacement, despite being one of the greatest
advances in medicine of the modern era, has recently come under
scrutiny. The National Health Service (NHS) has competing demands,
and resource allocation is challenging in times of economic restraint. Patients
who underwent THR (n = 348) or TKR (n = 323) between January and
July 2010 in one Scottish region were entered into a prospective
arthroplasty database. A health–utility score was derived from the
EuroQol (EQ-5D) score pre-operatively and at one year, and was combined
with individual life expectancy to derive the quality-adjusted life years
(QALYs) gained. Two-way analysis of variance was used to compare
QALYs gained between procedures, while controlling for baseline
differences. The number of QALYs gained was higher after THR than
after TKR (6.5 Cite this article:
Reverse total shoulder replacement (RTSR) depends
on adequate deltoid function for a successful outcome. However, the
anterior deltoid and/or axillary nerve may be damaged due to prior
procedures or injury. The purpose of this study was to determine
the compensatory muscle forces required for scapular plane elevation
following RTSR when the anterior deltoid is deficient. The soft
tissues were removed from six cadaver shoulders, except for tendon
attachments. After implantation of the RTSR, the shoulders were
mounted on a custom-made shoulder simulator to determine the mean
force in each muscle required to achieve 30° and 60° of scapular
plane elevation. Two conditions were tested: 1) Control with an
absent supraspinatus and infraspinatus; and 2) Control with anterior
deltoid deficiency. Anterior deltoid deficiency resulted in a mean
increase of 195% in subscapularis force at 30° when compared with
the control (p = 0.02). At 60°, the subscapularis force increased
a mean of 82% (p <
0.001) and the middle deltoid force increased
a mean of 26% (p = 0.04). Scapular plane elevation may still be possible following an RTSR
in the setting of anterior deltoid deficiency. When the anterior
deltoid is deficient, there is a compensatory increase in the force
required by the subscapularis and middle deltoid. Attempts to preserve
the subscapularis, if present, might maximise post-operative function.
The December 2012 Foot &
ankle Roundup360 looks at: correcting the overcorrected club foot; syndesmotic surgery; autograft for osteochondral defects; sesamoidectomy after fracture in athletes; complications in ankle replacement; the arthroscope as a treatment for ankle osteoarthritis; whether da Vinci was a modern foot surgeon; and a popliteal block in ankle fixation.
The December 2012 Hip &
Pelvis Roundup360 looks at: swimming against the tide with resurfacing; hip impingement surgery; the relationship between obesity and co-morbidities and joint replacement infection; cemented hips; cross-linked polyethylene notching; whether cement is necessary in oncological arthroplasty; and how total hip replacement may result in weight gain.
The lateral compartment is predominantly affected
in approximately 10% of patients with osteoarthritis of the knee. The
anatomy, kinematics and loading during movement differ considerably
between medial and lateral compartments of the knee. This in the
main explains the relative protection of the lateral compartment
compared with the medial compartment in the development of osteoarthritis.
The aetiology of lateral compartment osteoarthritis can be idiopathic,
usually affecting the femur, or secondary to trauma commonly affecting
the tibia. Surgical management of lateral compartment osteoarthritis
can include osteotomy, unicompartmental knee replacement and total
knee replacement. This review discusses the biomechanics, pathogenesis
and development of lateral compartment osteoarthritis and its management. Cite this article:
Smart trials are total knee tibial trial liners
with load bearing and alignment sensors that will graphically show quantitative
compartment load-bearing forces and component track patterns. These
values will demonstrate asymmetrical ligament balancing and misalignments
with the medial retinaculum temporarily closed. Currently surgeons
use feel and visual estimation of imbalance to assess soft-tissue
balancing and tracking with the medial retinaculum open, which results
in lower medial compartment loads and a wider anteroposterior tibial
tracking pattern. The sensor trial will aid the total knee replacement
surgeon in performing soft-tissue balancing by providing quantitative
visual feedback of changes in forces while performing the releases
incrementally. Initial experience using a smart tibial trial is
presented.
The February 2013 Children’s orthopaedics Roundup360 looks at: the human genome; new RNA; cells, matrix and gene enhancement; the histology of x-rays; THR and VTE in the Danish population; potential therapeutic targets for GCT; optimising vancomycin elution from cement; and how much sleep is enough.
The February 2013 Hip &
Pelvis Roundup360 looks at: amazing alumina; dual mobility; white cells and periprosthetic infection; cartilage and impingement surgery; acetabulum in combination; cementless ceramic prosthesis; metal-on-metal hips; and whether size matters in failure.
Post-operative complications after total hip
or knee replacement can delay recovery, prolong hospitalisation, increase
rates of re-admission and, in the most severe cases, lead to long-term
disability or even death. In this analysis of pooled data from four
large, randomised, phase III clinical trials that compared the oral,
direct Factor Xa inhibitor rivaroxaban with subcutaneous enoxaparin
for the prevention of venous thromboembolism after total hip or
knee replacement (n = 12 729), the incidence of complications, including
bleeding and adverse events related to surgery (such as wound infection,
wound dehiscence and haemarthrosis) are reported. Interventions
and procedures relating to surgery are also compared between the
groups. Bleeding events, including excessive wound haematoma and
surgical-site bleeding, occurred at similar rates in the rivaroxaban
and enoxaparin groups. Over the total study duration, adverse surgical
events occurred at a similar rate in the rivaroxaban group compared
with the enoxaparin group after total knee replacement (2.26% This analysis shows that the incidence of adverse surgical events
with rivaroxaban was similar to enoxaparin.
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
With the established success of the National
Joint Registry and the emergence of a range of new national initiatives for
the capture of electronic data in the National Health Service, orthopaedic
surgery in the United Kingdom has found itself thrust to the forefront
of an information revolution. In this review we consider the benefits
and threats that this revolution poses, and how orthopaedic surgeons
should marshal their resources to ensure that this is a force for
good.
Patient expectations and their fulfilment are
an important factor in determining patient-reported outcome and satisfaction
of hip (THR) and knee replacement (TKR). The aim of this prospective
cohort study was to examine the expectations of patients undergoing
THR and TKR, and to identify differences in expectations, predictors
of high expectations and the relationship between the fulfilment
of expectations and patient-reported outcome measures. During the
study period, patients who underwent 346 THRs and 323 TKRs completed
an expectation questionnaire, Oxford score and Short-Form 12 (SF-12)
score pre-operatively. At one year post-operatively, the Oxford
score, SF-12, patient satisfaction and expectation fulfilment were
assessed. Univariable and multivariable analysis were performed.
Improvements in mobility and daytime pain were the most important
expectations in both groups. Expectation level did not differ between
THR and TKR. Poor Oxford score, younger age and male gender significantly
predicted high pre-operative expectations (p <
0.001). The level
of pre-operative expectation was not significantly associated with
the fulfilment of expectations or outcome. THR better met the expectations
identified as important by patients. TKR failed to meet expectations
of kneeling, squatting and stair climbing. High fulfilment of expectation
in both THR and TKR was significantly predicted by young age, greater
improvements in Oxford score and high pre-operative mental health
scores. The fulfilment of expectations was highly correlated with satisfaction.
Following arthroplasty of the knee, the patient’s
perception of improvement in symptoms is fundamental to the assessment
of outcome. Better clinical outcome may offset the inferior survival
observed for some types of implant. By examining linked National
Joint Registry (NJR) and patient-reported outcome measures (PROMs)
data, we aimed to compare PROMs collected at a minimum of six months
post-operatively for total (TKR: n = 23 393) and unicondylar knee
replacements (UKR: n = 505). Improvements in knee-specific (Oxford
knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared
and adjusted for case-mix differences using multiple regression.
Whereas the improvements in the OKS and EQ-5D were significantly
greater for TKR than for UKR, once adjustments were made for case-mix
differences and pre-operative score, the improvements in the two
scores were not significantly different. The adjusted mean differences
in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI)
-0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37),
respectively. We found no difference in the improvement of either knee-specific
or general health outcomes between TKR and UKR in a large cohort
of registry patients. With concerns about significantly higher revision
rates for UKR observed in worldwide registries, we question the
widespread use of an arthroplasty that does not confer a significant
benefit in clinical outcome.
A total of 159 patients (84 women and 75 men,
mean age of 53 (20 to 87)) with subacromial impingement were randomised
to treatment with subacromial injections using lidocaine with one
of hyaluronic acid (51 patients), corticosteroid (53 patients) or
placebo (55 patients). Patients were followed up for 26 weeks. The
primary outcome was pain on a visual analogue score (VAS), and secondary
outcomes included the Constant Murley score, shoulder pain score,
functional mobility score, shoulder disability questionnaire and
pain-specific disability score. The different outcome measures showed
similar results. After three, six and 12 weeks corticosteroid injections
were superior to hyaluronic acid injections and only at six weeks
significantly better than placebo injections. The mean short-term
reduction in pain on the VAS score at 12 weeks was 7% ( We were not able to show a convincing benefit from hyaluronic
acid injections compared with corticosteroid or placebo injections.
Corticosteroid injections produced a significant reduction in pain
in the short term (three to 12 weeks), but in the long term the
placebo injection produced the best results.
Recent events have highlighted the importance
of implant design for survival and wear-related complications following
metal-on-metal hip resurfacing arthroplasty. The mid-term survival
of the most widely used implant, the Birmingham Hip Resurfacing
(BHR), has been described by its designers. The aim of this study
was to report the ten-year survival and patient-reported functional
outcome of the BHR from an independent centre. In this cohort of 554 patients (646 BHRs) with a mean age of
51.9 years (16.5 to 81.5) followed for a mean of eight years (1
to 12), the survival and patient-reported functional outcome depended
on gender and the size of the implant. In female hips (n = 267)
the ten-year survival was 74% (95% confidence interval (CI) 83 to
91), the ten-year revision rate for pseudotumour was 7%, the mean
Oxford hip score (OHS) was 43 ( This study supports the ongoing use of resurfacing in young active
men, who are a subgroup of patients who tend to have problems with
conventional THR. In contrast, the results in women have been poor
and we do not recommend metal-on-metal resurfacing in women. Continuous
follow-up is recommended because of the increasing incidence of
pseudotumour with the passage of time.
Techniques for fixation of fractures of the lateral
malleolus have remained essentially unchanged since the 1960s, but
are associated with complication rates of up to 30%. The fibular
nail is an alternative method of fixation requiring a minimal incision
and tissue dissection, and has the potential to reduce the incidence
of complications. We reviewed the results of 105 patients with unstable fractures
of the ankle that were fixed between 2002 and 2010 using the Acumed
fibular nail. The mean age of the patients was 64.8 years (22 to
95), and 80 (76%) had significant systemic medical comorbidities.
Various different configurations of locking screw were assessed
over the study period as experience was gained with the device.
Nailing without the use of locking screws gave satisfactory stability
in only 66% of cases (4 of 6). Initial locking screw constructs
rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable.
Overall, seven patients had loss of fixation of the fracture and
there were five post-operative wound infections related to the distal
fibula. This lead to the development of the current technique with
a screw across the syndesmosis in addition to a distal locking screw.
In 21 patients treated with this technique there have been no significant
complications and only one superficial wound infection. Good fracture
reduction was achieved in all of these patients. The mean physical
component Short-Form 12, Olerud and Molander score, and American Academy
of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean
of six years post-injury were 46 (28 to 61), 65 (35 to 100) and
83 (52 to 99), respectively. There have been no cases of fibular
nonunion. Nailing of the fibula using our current technique gives good
radiological and functional outcomes with minimal complications,
and should be considered in the management of patients with an unstable
ankle fracture.
We present our experience of forearm lengthening
in children with various conditions performed by a single surgeon between
1995 and 2009. A total of 19 children with a mean age of 9.8 years
(2.1 to 15.9) at the time of surgery had 22 forearm lengthenings
using either an Ilizarov/spatial and Ilizarov circular frame or
a monolateral external fixator. The patients were divided into two
groups: group A, in whom the purpose of treatment was to restore
the relationship between the radius and the ulna, and group B, in
whom the objective was to gain forearm length. The mean follow-up after
removal of the frame was 26 months (13 to 53). There were ten patients (11 forearms) in group A with a mean
radioulnar discrepancy of 2.4 cm (1.5 to 3.3) and nine patients
(11 forearms) in group B. In group A, the mean lengthening achieved
was 2.7 cm (1.0 to 5.5), with a lengthening index of 11.1 weeks/cm.
Equalisation or overcorrection of the discrepancy was achieved in
seven of 11 forearms, but lengthening was only partially successful
at preventing subluxation or dislocation of the radial head. In
group B, the mean lengthening achieved was 3.8 cm (1.9 to 6.8),
with a lengthening index of 7.25 weeks/cm. Common complications
in both groups were pin-site infection and poor regenerate formation. Forearm lengthening by distraction osteogenesis is a worthwhile
procedure in children that can improve cosmesis and function, particularly
in patients with shortening of both radius and ulna.