The purpose of this study was to describe the
radiological characteristics of a previously unreported finding: posterior
iliac offset at the sacroiliac joint and to assess its association
with pelvic instability as measured by initial displacement and
early implant loosening or failure. Radiographs from 42 consecutive
patients with a mean age of 42 years (18 to 77; 38 men, four women)
and mean follow-up of 38 months (3 to 96) with Anteroposterior Compression
II injuries, were retrospectively reviewed. Standardised measurements
were recorded for the extent of any diastasis of the pubic symphysis,
widening of the sacroiliac joint, static vertical ramus offset and
a novel measurement (posterior offset of the ilium at the sacroiliac
joint identified on axial CT scan). Pelvic fractures with posterior
iliac offset exhibited greater levels of initial displacement of
the anterior pelvis (anterior sacroiliac widening, pubic symphysis
diastasis and static vertical ramus offset, p <
0.001,0.034 and
0.028, respectively). Pelvic fractures with posterior ilium offset
also demonstrated higher rates of implant loosening regardless of
fixation method (p = 0.05). Posterior offset of the ilium was found
to be a reliable and reproducible measurement with substantial inter-observer
agreement (kappa = 0.70). Posterior offset of the ilium on axial
CT scan is associated with greater levels of initial pelvic displacement
and early implant loosening. Cite this article:
Cancellous allograft bone chips are commonly
used in the reconstruction of defects in bone after removal of benign tumours.
We investigated the MRI features of grafted bone chips and their
change over time, and compared them with those with recurrent tumour.
We retrospectively reviewed 66 post-operative MRIs from 34 patients
who had undergone curettage and grafting with cancellous bone chips
to fill the defect after excision of a tumour. All grafts showed
consistent features at least six months after grafting: homogeneous
intermediate or low signal intensities with or without scattered
hyperintense foci (speckled hyperintensities) on T1 images; high
signal intensities with scattered hypointense foci (speckled hypointensities)
on T2 images, and peripheral rim enhancement with or without central
heterogeneous enhancements on enhanced images. Incorporation of
the graft occurred from the periphery to the centre, and was completed
within three years. Recurrent lesions consistently showed the same signal
intensities as those of pre-operative MRIs of the primary lesions.
There were four misdiagnoses, three of which were chondroid tumours. We identified typical MRI features and clarified the incorporation
process of grafted cancellous allograft bone chips. The most important
characteristics of recurrent tumours were that they showed the same
signal intensities as the primary tumours. It might sometimes be
difficult to differentiate grafted cancellous allograft bone chips
from a recurrent chondroid tumour. Cite this article:
The April 2012 Foot &
Ankle Roundup360 looks at injecting the tendon sheath, total ankle replacement, heterotopic ossification, replacement or arthrodesis, achilles tendinopathy, healing of the torn Achilles, grafting of the calcaneal bone cyst, avulsion fractures in athletes, percutaneous distal osteotomy for bunionette formation, and repairing the torn tibiofibular syndesmosis
The October 2014 Children’s orthopaedics Roundup360 looks at: spondylolisthesis management strategies; not all cervical collars are even; quality of life with Legg-Calve-Perthe’s disease; femoral shaft fractures in children; percutaneous trigger thumb release – avoid at all costs in children; predicting repeat surgical intervention in acute osteomyelitis; and C-Arm position inconsequential in radiation exposure
In May 2012, in airports across the globe, seven
orthopaedic surgeons bravely said goodbye to their loved ones, and
slowly turned towards their respective aircraft. Filled with expectation
and mild trepidation they stepped into the unknown… the ABC fellowship
of 2012.
The April 2012 Wrist &
Hand Roundup360 looks at releasing the trigger finger, function in the osteoarthritic hand, complex regional pain syndrome, arthroscopic ligamentoplasty for the injured scapholunate ligament, self-concept and upper limb deformities in children, wrist arthroscopy in children, internal or external fixation for the fractured distal radius, nerve grafting, splinting the PIPJ contracture, and finding the stalk of a dorsal wrist ganglion
The April 2013 Shoulder &
Elbow Roundup360 looks at: biceps, pressure and instability; chronic acromio-clavicular joint instability; depression and shoulder pain; shoulder replacement and transfusion; cuff integrity and function; iatropathic plexus injury; the accuracy of acromio-clavicular joint injection; and tennis as a risk factor for tennis elbow.
The April 2013 Foot &
Ankle Roundup360 looks at: whether arthroscopic arthrodesis is advantageous; osteochondral autografts; suture button associated fractures; an ultrasound solution to Achilles tendinopathy; the safety of the tendo Achilles in men; charcot and antibiotic-coated nails; and botox and Policeman’s Heel.
The August 2014 Wrist &
Hand Roundup360 looks at: Trapeziectomy superior to arthrodesis;
The February 2013 Spine Roundup360 looks at: complications with anterior decompression and fusion; lumbar claudication and peripheral vascular disease; increasing cervical instability in rheumatoids; kyphoplasty; cervical stenosis; exercise or fusion for chronic lower back pain; lumbar disc arthroplasty and adjacent level changes; and obese disc prolapses.
We examined the outcomes and levels of patient
satisfaction in 202 consecutive cases of ultrasound-guided supraclavicular
brachial plexus block (SBPB) in upper limb surgery performed between
September 2007 and March 2010. All blocks were performed by orthopaedic surgeons using ultrasound
visualisation with a high-frequency linear probe. The probe was
placed in the coronal–oblique plane in the supraclavicular fossa,
and the puncture was ‘in-plane’ from lateral to medial. Most of
the blocks were performed with 0.75% ropivacaine/1% lidocaine (1:1),
with or without adrenaline in 1:200 000 dilution. In 201 patients
(99.5%) the brachial plexus block permitted surgery without conversion
to general anaesthesia. The mean procedure time for block was 3.9
min (2 to 12), the mean waiting time for surgery was 34.1 min (10
to 64), the mean surgical time was 75.2 min (6 to 232), and the
mean duration of post-anaesthetic analgesia was 437 min (171 to
992). A total of 20 patients (10%) developed a transient Horner’s syndrome.
No nerve injury, pneumothorax, arterial puncture or systemic anaesthetic
toxicity were recorded. Most patients (96.7%) were satisfied with
ultrasound-guided SBPB. This study demonstrates the efficacy and
safety of ultrasound-guided SBPB for orthopaedic surgery on the
upper limb. Cite this article:
The April 2014 Hip & Pelvis Roundup360 looks at: Recent arthroplasty and flight; whether that squeak could be a fracture; diagnosing early infected hip replacement; impaction grafting at a decade; whether squeaking is more common than previously thought; femoral offset associated with post THR outcomes; and periprosthetic fracture stabilisation.
Mechanical alignment has been a fundamental tenet of total knee arthroplasty (TKA) since modern knee replacement surgery was developed in the 1970s. The objective of mechanical alignment was to infer the greatest biomechanical advantage to the implant to prevent early loosening and failure. Over the last 40 years a great deal of innovation in TKA technology has been focusing on how to more accurately achieve mechanical alignment. Recently the concept of mechanical alignment has been challenged, and other alignment philosophies are being explored with the intention of trying to improve patient outcomes following TKA. This article examines the evolution of the mechanical alignment concept and whether there are any viable alternatives.
Failure of fixation is a common problem in the treatment of osteoporotic fractures around the hip. The reinforcement of bone stock or of fixation of the implant may be a solution. Our study assesses the existing evidence for the use of bone substitutes in the management of these fractures in osteoporotic patients. Relevant publications were retrieved through Medline research and further scrutinised. Of 411 studies identified, 22 met the inclusion criteria, comprising 12 experimental and ten clinical reports. The clinical studies were evaluated with regard to their level of evidence. Only four were prospective and randomised. Polymethylmethacrylate and calcium-phosphate cements increased the primary stability of the implant-bone construct in all experimental and clinical studies, although there was considerable variation in the design of the studies. In randomised, controlled studies, augmentation of intracapsular fractures of the neck of the femur with calcium-phosphate cement was associated with poor long-term results. There was a lack of data on the long-term outcome for trochanteric fractures. Because there were only a few, randomised, controlled studies, there is currently poor evidence for the use of bone cement in the treatment of fractures of the hip.
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
This short contribution aims to explain how intervertebral disc ‘degeneration’ differs from normal ageing, and to suggest how mechanical loading and constitutional factors interact to cause disc degeneration and prolapse. We suggest that disagreement on these matters in medico-legal practice often arises from a misunderstanding of the nature of ‘soft-tissue injuries’.
The biomechanical function of the anteromedial
(AM) and posterolateral (PL) bundles of the anterior cruciate ligament
(ACL) remains controversial. Some studies report that the AM bundle
stabilises the knee joint in anteroposterior (AP) translation and
rotational movement (both internal and external) to the same extent
as the PL bundle. Others conclude that the PL bundle is more important
than the AM in controlling rotational movement. The objective of this randomised cohort study involving 60 patients
(39 men and 21 women) with a mean age of 32.9 years (18 to 53) was
to evaluate the function of the AM and the PL bundles of the ACL
in both AP and rotational movements of the knee joint after single-bundle
and double-bundle ACL reconstruction using a computer navigation
system. In the double-bundle group the patients were also randomised
to have the AM or the PL bundle tensioned first, with knee laxity
measured after each stage of reconstruction. All patients had isolated
complete ACL tears, and the presence of a meniscal injury was the
only supplementary pathology permitted for inclusion in the trial.
The KT-1000 arthrometer was used to apply a constant load to evaluate
the AP translation and the rolimeter was used to apply a constant
rotational force. For the single-bundle group deviation was measured
before and after ACL reconstruction. In the double-bundle group
deviation was measured for the ACL-deficient, AM- or PL-reconstructed
first conditions and for the total reconstruction. We found that the AM bundle in the double-bundle group controlled
rotation as much as the single-bundle technique, and to a greater
extent than the PL bundle in the double-bundle technique. The double-bundle
technique increases AP translation and rotational stability in internal
rotation more than the single-bundle technique.
The April 2014 Foot &
Ankle Roundup360 looks at: Hawkins fractures revisited; arthrodesis compared with ankle replacement in osteoarthritis; mobile bearing ankle replacement successful in the longer-term; osteolysis is an increasing worry in ankle replacement; ankle synostosis post-fracture is not important; radiofrequency ablation for plantar fasciitis; and the right approach for tibiotalocalcaneal fusion.