In this study we randomised 140 patients who
were due to undergo primary total knee arthroplasty (TKA) to have the
procedure performed using either patient-specific cutting guides
(PSCG) or conventional instrumentation (CI). The primary outcome measure was the mechanical axis, as measured
at three months on a standing long-leg radiograph by the hip–knee–ankle
(HKA) angle. This was undertaken by an independent observer who
was blinded to the instrumentation. Secondary outcome measures were
component positioning, operating time, Knee Society and Oxford knee
scores, blood loss and length of hospital stay. A total of 126 patients (67 in the CI group and 59 in the PSCG
group) had complete clinical and radiological data. There were 88
females and 52 males with a mean age of 69.3 years (47 to 84) and
a mean BMI of 28.6 kg/m2 (20.2 to 40.8). The mean HKA
angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4
to 183.4) in the PSCG group (p = 0.34). Outliers were identified
in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%)
in the PSCG group (p = 0.99). There was no significant difference
in the clinical results (p = 0.95 and 0.59, respectively). Operating time,
blood loss and length of hospital stay were not significantly reduced
(p = 0.09, 0.58 and 0.50, respectively) when using PSCG. The use of PSCG in primary TKA did not reduce the proportion
of outliers as measured by post-operative coronal alignment. Cite this article:
Arthritis of the wrist is a painful disabling
condition that has various causes and presentations. The traditional treatment
has been a total wrist fusion at a price of the elimination of movement.
However, forms of treatment which allow the preservation of movement
are now preferred. Modern arthroplasties of the wrist are still
not sufficiently robust to meet the demands of many patients, nor
do they restore normal kinematics of the wrist. A preferable compromise
may be selective excision and partial fusion of the wrist using
knowledge of the aetiology and pattern of degenerative change to
identify which joints can be sacrificed and which can be preserved. This article provides an overview of the treatment options available
for patients with arthritis of the wrist and an algorithm for selecting
an appropriate surgical strategy. Cite this article:
In this study of patients who underwent internal fixation without
fusion for a burst thoracolumbar or lumbar fracture, we compared
the serial changes in the injured disc height (DH), and the fractured
vertebral body height (VBH) and kyphotic angle between patients
in whom the implants were removed and those in whom they were not. Radiological
parameters such as injured DH, fractured VBH and kyphotic angle
were measured. Functional outcomes were evaluated using the Greenough
low back outcome scale and a VAS scale for pain. Between June 1996 and May 2012, 69 patients were analysed retrospectively;
47 were included in the implant removal group and 22 in the implant
retention group. After a mean follow-up of 66 months (48 to 107),
eight patients (36.3%) in the implant retention group had screw
breakage. There was no screw breakage in the implant removal group.
All radiological and functional outcomes were similar between these
two groups. Although solid union of the fractured vertebrae was
achieved, the kyphotic angle and the anterior third of the injured
DH changed significantly with time (p <
0.05). Methods
Results
We report the five-year outcome of a randomised
controlled trial which used radiostereometric analysis (RSA) to assess
the influence of surface oxidised zirconium (OxZr, Oxinium) on polyethylene
wear A total of 120 patients, 85 women and 35 men with a mean age
of 70 years (59 to 80) who were scheduled for primary cemented total
hip arthroplasty were randomly allocated to four study groups. Patients
were blinded to their group assignment and received either a conventional
polyethylene (CPE) or a highly cross-linked (HXL) acetabular component
of identical design. On the femoral side patients received a 28
mm head made of either cobalt-chromium (CoCr) or OxZr. The proximal head penetration (wear) was measured with repeated
RSA examinations over five years. Clinical outcome was measured
using the Harris hip score. There was no difference in polyethylene wear between the two
head materials when used with either of the two types of acetabular
component (p = 0.3 to 0.6). When comparing the two types of polyethylene
there was a significant difference in favour of HXLPE, regardless
of the head material used (p <
0.001). In conclusion, we found no advantage of OxZr over CoCr in terms
of polyethylene wear after five years of follow-up. Our findings
do not support laboratory results which have shown a reduced rate
of wear with OxZr. They do however add to the evidence on the better
resistance to wear of HXLPE over CPE. Cite this article:
Total Of the 54 patients who underwent TES for a primary tumour between
1993 and 2010, 19 died and four were lost to follow-up. In January
2012, a questionnaire was sent to the 31 surviving patients. This
included the short form-36 to assess HRQoL and questions about the
current condition of their disease, activities of daily living (ADL)
and surgery. The response rate was high at 83.9% (26/31 patients).
We found that most patients were satisfied and maintained good performance
of their ADLs. The mental health status and social roles of the HRQoL scores
were nearly equivalent to those of healthy individuals, regardless
of the time since surgery. There was significant impairment of physical
health in the early post-operative years, but this usually returned
to normal approximately three years after surgery. Cite this article:
The aims of this study were to compare the diagnostic test characteristics
of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI)
alone, and ultrasound combined with MARS-MRI for identifying intra-operative
pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients
undergoing revision surgery. This retrospective diagnostic accuracy study involved 39 patients
(40 MoMHRs). The time between imaging modalities was a mean of 14.6
days (0 to 90), with imaging performed at a mean of 5.3 months (0.06
to 12) before revision. The prevalence of intra-operative pseudotumours
was 82.5% (n = 33).Aims
Methods
The objective of this study was to evaluate the rotation and
translation of each joint in the hindfoot and compare the load response
in healthy feet with that in stage II posterior tibial tendon dysfunction
(PTTD) flatfoot by analysing the reconstructive three-dimensional
(3D) computed tomography (CT) image data during simulated weight-bearing. CT scans of 15 healthy feet and 15 feet with stage II PTTD flatfoot
were taken first in a non-weight-bearing condition, followed by
a simulated full-body weight-bearing condition. The images of the
hindfoot bones were reconstructed into 3D models. The ‘twice registration’
method in three planes was used to calculate the position of the
talus relative to the calcaneus in the talocalcaneal joint, the
navicular relative to the talus in talonavicular joint, and the cuboid
relative to the calcaneus in the calcaneocuboid joint.Objective
Methods
To confirm whether developmental dysplasia of
the hip has a risk of hip impingement, we analysed maximum ranges
of movement to the point of bony impingement, and impingement location
using three-dimensional (3D) surface models of the pelvis and femur
in combination with 3D morphology of the hip joint using computer-assisted methods.
Results of computed tomography were examined for 52 hip joints with
DDH and 73 normal healthy hip joints. DDH shows larger maximum extension
(p = 0.001) and internal rotation at 90° flexion (p <
0.001).
Similar maximum flexion (p = 0.835) and external rotation (p = 0.713)
were observed between groups, while high rates of extra-articular
impingement were noticed in these directions in DDH (p <
0.001).
Smaller cranial acetabular anteversion (p = 0.048), centre-edge
angles (p <
0.001), a circumferentially shallower acetabulum,
larger femoral neck anteversion (p <
0.001), and larger alpha
angle were identified in DDH. Risk of anterior impingement in retroverted
DDH hips is similar to that in retroverted normal hips in excessive
adduction but minimal in less adduction. These findings might be
borne in mind when considering the possibility of extra-articular
posterior impingement in DDH being a source of pain, particularly
for patients with a highly anteverted femoral neck. Cite this article:
Healing in cancellous metaphyseal bone might be different from
midshaft fracture healing due to different access to mesenchymal
stem cells, and because metaphyseal bone often heals without a cartilaginous
phase. Inflammation plays an important role in the healing of a
shaft fracture, but if metaphyseal injury is different, it is important
to clarify if the role of inflammation is also different. The biology
of fracture healing is also influenced by the degree of mechanical
stability. It is unclear if inflammation interacts with stability-related
factors. We investigated the role of inflammation in three different models:
a metaphyseal screw pull-out, a shaft fracture with unstable nailing
(IM-nail) and a stable external fixation (ExFix) model. For each,
half of the animals received dexamethasone to reduce inflammation,
and half received control injections. Mechanical and morphometric evaluation
was used.Objectives
Methods
The October 2014 Knee Roundup360 looks at: microfracture equivalent to OATS; examination better than MRI in predicting hamstrings re-injury; a second view on return to play with hamstrings injuries; dislocation risks in the Oxford Unicompartmental Knee; what about the tibia?; getting on top of lateral facet pain post TKR; readmission in TKR; patient-specific instrumentation; treating infrapatellar saphenous neuralgia; and arthroscopy in the middle-aged.
A total of 22 patients with a tibial avulsion
fracture involving the insertion of the posterior cruciate ligament
(PCL) with grade II or III posterior laxity were reduced and fixed
arthroscopically using routine anterior and double posteromedial
portals. A double-strand Ethibond suture was inserted into the joint
and wrapped around the PCL from anterior to posterior to secure
the ligament above the avulsed bony fragment. Two tibial bone tunnels
were created using the PCL reconstruction guide, aiming at the medial
and lateral borders of the tibial bed. The ends of the suture were
pulled out through the bone tunnels and tied over the tibial cortex
between the openings of the tunnels to reduce and secure the bony
fragment. Satisfactory reduction of the fracture was checked arthroscopically and
radiographically. The patients were followed-up for a mean of 24.5 months (19 to
28). Bone union occurred six weeks post-operatively. At final follow-up,
all patients had a negative posterior drawer test and a full range
of movement. KT-1000 arthrometer examination showed that the mean
post-operative side-to-side difference improved from 10.9 mm (standard
deviation ( We conclude that this technique is convenient, reliable and minimally
invasive and successfully restores the stability and function of
the knee. Cite this article:
The most widely used classification system for
acetabular fractures was developed by Judet, Judet and Letournel over
50 years ago primarily to aid surgical planning. As population demographics
and injury mechanisms have altered over time, the fracture patterns
also appear to be changing. We conducted a retrospective review
of the imaging of 100 patients with a mean age of 54.9 years (19
to 94) and a male to female ratio of 69:31 seen between 2010 and
2013 with acetabular fractures in order to determine whether the
current spectrum of injury patterns can be reliably classified using
the original system. Three consultant pelvic and acetabular surgeons and one senior
fellow analysed anonymous imaging. Inter-observer agreement for
the classification of fractures that fitted into defined categories
was substantial, (κ = 0.65, 95% confidence interval (CI) 0.51 to
0.76) with improvement to near perfect on inclusion of CT imaging
(κ = 0.80, 95% CI 0.69 to 0.91). However, a high proportion of injuries
(46%) were felt to be unclassifiable by more than one surgeon; there
was moderate agreement on which these were (κ = 0.42 95% CI 0.31
to 0.54). Further review of the unclassifiable fractures in this cohort
of 100 patients showed that they tended to occur in an older population
(mean age 59.1 years; 22 to 94 Cite this article:
A self-control ratio, the spine-pelvis index
(SPI), was proposed for the assessment of patients with adolescent idiopathic
scoliosis (AIS) in this study. The aim was to evaluate the disproportionate
growth between the spine and pelvis in these patients using SPI.
A total of 64 female patients with thoracic AIS were randomly enrolled
between December 2010 and October 2012 (mean age 13 years, standard
deviation ( No significant difference in SPI was found in different age groups
in the control group, making the SPI an age-independent parameter
with a mean value of 2.219 (2.164 to 2.239). We also found that
the SPI was not related to maturity in the control group. This study, for the first time, used a self-control ratio to
confirm the disproportionate patterns of growth of the spine and
pelvis in patients with thoracic AIS, highlighting that the SPI
is not affected by age or maturity. Cite this article:
There is an increased risk of fracture following
osteoplasty of the femoral neck for cam-type femoroacetabular impingement
(FAI). Resection of up to 30% of the anterolateral head–neck junction
has previously been considered to be safe, however, iatrogenic fractures
have been reported with resections within these limits. We re-evaluated
the amount of safe resection at the anterolateral femoral head–neck
junction using a biomechanically consistent model. In total, 28 composite bones were studied in four groups: control,
10% resection, 20% resection and 30% resection. An axial load was
applied to the adducted and flexed femur. Peak load, deflection
at time of fracture and energy to fracture were assessed using comparison
groups. There was a marked difference in the mean peak load to fracture
between the control group and the 10% resection group (p <
0.001).
The control group also tolerated significantly more deflection before
failure (p <
0.04). The mean peak load (p = 0.172), deflection
(p = 0.547), and energy to fracture (p = 0.306) did not differ significantly between
the 10%, 20%, and 30% resection groups. Any resection of the anterolateral quadrant of the femoral head–neck
junction for FAI significantly reduces the load-bearing capacity
of the proximal femur. After initial resection of cortical bone,
there is no further relevant loss of stability regardless of the
amount of trabecular bone resected. Based on our findings we recommend any patients who undergo anterolateral
femoral head–neck junction osteoplasty should be advised to modify
their post-operative routine until cortical remodelling occurs to
minimise the subsequent fracture risk. Cite this article:
Partial knee arthroplasty (PKA), either medial
or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty
(PFA) are a good option in suitable patients and have the advantages
of reduced operative trauma, preservation of both cruciate ligaments
and bone stock, and restoration of normal kinematics within the
knee joint. However, questions remain concerning long-term survival.
The goal of this review article was to present the long-term results
of medial and lateral UKA, PFA and combined compartmental arthroplasty
for multicompartmental disease. Medium- and long-term studies suggest
reasonable outcomes at ten years with survival greater than 95% in
UKA performed for medial osteoarthritis or osteonecrosis, and similarly
for lateral Cite this article:
We performed a randomised controlled trial comparing
computer-assisted surgery (CAS) with conventional surgery (CONV)
in total knee replacement (TKR). Between 2009 and 2011 a total of
192 patients with a mean age of 68 years (55 to 85) with osteoarthritis
or arthritic disease of the knee were recruited from four Norwegian
hospitals. At three months follow-up, functional results were marginally
better for the CAS group. Mean differences (MD) in favour of CAS
were found for the Knee Society function score (MD: 5.9, 95% confidence
interval (CI) 0.3 to 11.4, p = 0.039), the Knee Injury and Osteoarthritis
Outcome Score (KOOS) subscales for ‘pain’ (MD: 7.7, 95% CI 1.7 to
13.6, p = 0.012), ‘sports’ (MD: 13.5, 95% CI 5.6 to 21.4, p = 0.001)
and ‘quality of life’ (MD: 7.2, 95% CI 0.1 to 14.3, p = 0.046).
At one-year follow-up, differences favouring CAS were found for
KOOS ‘sports’ (MD: 11.0, 95% CI 3.0 to 19.0, p = 0.007) and KOOS
‘symptoms’ (MD: 6.7, 95% CI 0.5 to 13.0, p = 0.035). The use of
CAS resulted in fewer outliers in frontal alignment (>
3° malalignment),
both for the entire TKR (37.9% Cite this article:
Radiological assessment of total and unicompartmental
knee replacement remains an essential part of routine care and follow-up.
Appreciation of the various measurements that can be identified
radiologically is important. It is likely that routine plain radiographs
will continue to be used, although there has been a trend towards
using newer technologies such as CT, especially in a failing knee,
where it provides more detailed information, albeit with a higher
radiation exposure. The purpose of this paper is to outline the radiological parameters
used to evaluate knee replacements, describe how these are measured
or classified, and review the current literature to determine their
efficacy where possible.
This pilot study reports the clinical outcomes
of a combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty in patients with rotatator cuff arthropathy. A
total of 30 patients (30 shoulders; eight men and 22 women) with
a mean age of 74 years (55 to 84) were assessed at a mean follow-up
of 31 months (24 to 60). The inclusion criteria were painful cuff
tear arthropathy with normal deltoid function and a non-degenerative subscapularis
muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles
score, the Japanese Orthopaedic Association score, and the Oxford
Shoulder Score. Radiographic measurements included the centre of
rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively.
The active flexion and external rotation improved significantly
at the most recent follow-up (p <
0.035). Although the mean centre
of rotation distance changed significantly (p <
0.001), the mean
length of the deltoid did not change significantly from the pre-operative
value (p = 0.29). The change in the length of the deltoid with <
100° flexion was significantly less than that with >
100° (p <
0.001). Progressive erosion of the glenoid was seen in four patients.
No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty effectively restored function and relieved pain
in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5.
Because there have been no standard methods to determine pre-operatively
the thickness of resection of the proximal tibia in unicompartmental
knee arthroplasty (UKA), information about the relationship between
the change of limb alignment and the joint line elevation would
be useful for pre-operative planning. The purpose of this study
was to clarify the correlation between the change of limb alignment
and the change of joint line height at the medial compartment after
UKA. A consecutive series of 42 medial UKAs was reviewed retrospectively.
These patients were assessed radiographically both pre- and post-operatively
with standing anteroposterior radiographs. The thickness of bone
resection at the proximal tibia and the distal femur was measured
radiographically. The relationship between the change of femorotibial
angle (δFTA) and the change of joint line height, was analysed.Objectives
Methods
We compared the clinical, radiological and quality-of-life
outcomes between hybrid and total pedicle screw instrumentation
in patients undergoing surgery for neuromuscular scoliosis. Total pedicle screw instrumentation provided shorter operating
times, less blood loss and better correction of the major curve
compared with hybrid constructs in patients undergoing surgery for
neuromuscular scoliosis.