To systematically review qualitative studies of patients with distal tibia or ankle fracture, and explore their experience of injury and recovery. We undertook a systematic review of qualitative studies. Five databases were searched from inception to 1 February 2022. All titles and abstracts were screened, and a subset were independently assessed. Methodological quality was appraised using the Critical Appraisal Skills Programme (CASP) checklist. The GRADE-CERQual checklist was used to assign confidence ratings. Thematic synthesis was used to analyze data with the identification of codes which were drawn together to form subthemes and then themes.Aims
Methods
Conventional methods of treating ankle fractures
in the elderly are associated with high rates of complication. We describe
the results of treating these injuries in 48 frail elderly patients
with a long calcaneotalotibial nail. The mean age of the group was 82 years (61 to 96) and 41 (85%)
were women. All were frail, with multiple medical comorbidities
and their mean American Society of Anaesthesiologists score was
3 (3 to 4). None could walk independently before their operation.
All the fractures were displaced and unstable; the majority (94%,
45 of 48) were low-energy injuries and 40% (19 of 48) were open. . The overall mortality at six months was 35%. Of the surviving
patients, 90% returned to their pre-injury level of function. The
mean pre- and post-operative Olerud and Molander questionnaire scores
were 62 and 57 respectively. Complications included superficial
infection (4%, two of 48); deep infection (2%, one of 48); a broken
or loose distal locking screw (6%, three of 48); valgus malunion
(4%, two of 48); and one below-knee amputation following an unsuccessful
vascular operation. There were no cases of nonunion, nail breakage
or peri-prosthetic fracture. . A calcaneotalotibial nail is an excellent device for treating
an
Redisplacement of
The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An
Aims. The fundamental concept of open reduction and internal fixation
(ORIF) of ankle fractures has not changed appreciably since the
1960s and, whilst widely used, is associated with complications
including wound dehiscence and infection, prominent hardware and
failure. Closed reduction and intramedullary fixation (CRIF) using
a fibular nail, wires or screws is biomechanically stronger, requires
minimal incisions, and has low-profile hardware. We hypothesised
that fibular nailing in the elderly would have similar functional
outcomes to standard fixation, with a reduced rate of wound and
hardware problems. Patients and Methods. A total of 100 patients (25 men, 75 women) over the age of 65
years with
This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.Aims
Methods
Eight cases of
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in
Six mechanisms which may produce fracture-separation of the proximal humeral epiphysis are proposed. Four of them are illustrated by case reports. It is suggested that they may be differentiated by examination of the patient and study of the radiographs. In
We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These
Fractures of the proximal forearm in young children may be unstable with the elbow flexed but stable with it in extension. Fifteen such fractures were managed by immobilisation in long-arm casts with the elbow extended. Only one patient had more than 15 degrees angulation at the time of bony union. All obtained normal elbow movement at two weeks and full forearm rotation at follow-up. No casts fell off. The extended elbow cast is awkward but it provides an alternative to internal fixation for some
Failure of fixation is a major complication of the treatment of unstable intertrochanteric fractures. A retrospective review was performed of 54 such fractures treated with a sliding screw-plate device. Linear and angular displacements were calculated from radiographs taken at operation and serially until healing was complete. Linear displacement was related to fracture instability, but the neck-shaft angle was relatively constant during healing. Complications were often due to failure of the sliding mechanism of the implant. We conclude that a sliding screw-plate allows controlled collapse of the major fragments but maintains the neck-shaft angle even in
Distraction fractures of the upper lumbar spine are most often associated with the wearing of seat-belts. Twenty patients with this spinal fracture were reviewed and half of them had intra-abdominal injuries. Eight patients required an exploratory laparotomy. Three distinct patterns of distraction fractures have been identified. Open reduction, local spinal fusion and Harrington instrumentation are recommended for
1. The management of fractures in five patients with haemophilia is described: two patients had antibodies to antihaemophilic globulin. 2. The principles of management of injured haemophilia patients are described, as are the special problems in patients with antibodies to AHG. 3. Stability of the fragments must be achieved to prevent the hazards of displacement of the fracture, recurrent bleeding and pseudotumour formation which may threaten viability of the limb. 4. Stabilisation of potentially