The April 2015 Wrist &
Hand Roundup360 looks at: Non-operative hand fracture management; From the sublime to the ridiculous?; A novel approach to carpal tunnel decompression; Osteoporosis and functional scores in the distal radius; Ulnar variance and force distribution; Tourniquets in carpal tunnel under the spotlight; Scaphoid fractures reclassified; Osteoporosis and distal radial fracture fixation; PROMISing results in the upper limb
Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.
The Unified Classification System (UCS) emphasises
the key principles in the assessment and management of peri-prosthetic
fractures complicating partial or total joint replacement. We tested the inter- and intra-observer agreement for the UCS
as applied to the pelvis and femur using 20 examples of peri-prosthetic
fracture in 17 patients. Each subtype of the UCS was represented
by at least one case. Specialist orthopaedic surgeons (experts)
and orthopaedic residents (pre-experts) assessed reliability on
two separate occasions. For the pelvis, the UCS showed inter-observer agreement of 0.837
(95% confidence intervals (CI) 0.798 to 0.876) for the experts and
0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer
agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and
0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the
UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765
to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773)
for the pre-experts. The intra-observer agreement was 0.920 (95%
CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892)
for the pre-experts. This corresponds to a substantial and ‘almost
perfect’ inter- and intra-observer agreement for the UCS for peri-prosthetic
fractures of the pelvis and femur. We hope that unifying the terminology of these injuries will
assist in their assessment, treatment and outcome. Cite this article:
In the management of a pelvic fracture prompt recognition of an unstable fracture pattern is important in reducing mortality and morbidity. It is believed that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. However, there is little evidence in the literature to support this view. The aim of this study was to determine whether a fracture of the transverse process of L5 is a reliable predictor of pelvic fracture instability. We reviewed our hospital trauma database and identified 80 patients who sustained a pelvic fracture between 2006 and 2010. There were 32 women and 48 men with a mean age of 40 years (10 to 96). Most patients were injured in a road traffic accident or as a result of a fall from a height. A total of 41 patients (51%) had associated injuries. The pelvic fractures were categorised according to the Burgess and Young classification. There were 45 stable and 35 unstable fractures. An associated fracture of the transverse process of L5 was present in 17 patients; 14 (40%) of whom had an unstable fracture pattern. The odds ratio for an unstable fracture of the pelvis in the presence of a fracture of the transverse process of L5 was 9.3 and the relative risk was 2.5. A fracture of the transverse process of L5 in the presence of a pelvic fracture is associated with an increased risk of instability of the pelvic fracture. Its presence should alert the attending staff to this possibility.
We are currently facing an epidemic of periprosthetic
fractures around the hip. They may occur either during surgery or
post-operatively. Although the acetabulum may be involved, the femur
is most commonly affected. We are being presented with new, difficult
fracture patterns around cemented and cementless implants, and we
face the challenge of an elderly population who may have grossly
deficient bone and may struggle to rehabilitate after such injuries.
The correct surgical management of these fractures is challenging.
This article will review the current choices of implants and techniques
available to deal with periprosthetic fractures of the femur. Cite this article:
There are many reasons why a total knee replacement
(TKR) may fail and qualify for revision. Successful revision surgery
depends as much on accurate assessment of the problem TKR as it
does on revision implant design and surgical technique. Specific
modes of failure require specific surgical solutions. Causes of
failure are often presented as a list or catalogue, without a system
or process for making a decision. In addition, strict definitions
and consensus on modes of failure are lacking in published series
and registry data. How we approach the problem TKR is an essential
but neglected aspect of understanding knee replacement surgery.
It must be carried out systematically, comprehensively and efficiently.
Eight modes of failure are described: 1) sepsis; 2) extensor discontinuity;
3) stiffness; 4) tibial- femoral instability; 5) patellar tracking;
6) aseptic loosening and osteolysis; 7) periprosthetic fracture
and 8) component breakage. A ninth ‘category’, unexplained pain
is an indication for further investigation but not surgery. Cite this article:
The October 2014 Trauma Roundup360 looks at: proximal humeral fractures in children; quadrilateral surface plates in transverse acetabular fractures; sleep deprivation and poor outcomes in trauma; bipolar hemiarthroplasty; skeletal traction; forefoot fractures; telemedicine in trauma; ketamine infusion for orthopaedic injuries; and improved functional outcomes seen with trauma networks.
An atypical femoral fracture (AFF), with a transverse
fracture radiologically through the lateral cortex is a rare but serious
condition. In order to improve our ability to identify patients
with this condition, we retrospectively surveyed all subtrochanteric,
peri-implant and diaphyseal femoral fractures in patients aged ≥ 65
years who underwent surgical treatment at our hospital between 2004
and 2011. We describe the incidence of atypical fractures and their characteristics,
with observational data including a review of the hospital and general
practitioner records. Clinical outcomes were evaluated using the
Harris hip score (HHS) and the timed up-and-go (TUG) test. Atypical fractures only occurred in women with an incidence of
9.8 per 100 000 person-years. The incidence in those who were treated
with bisphosphonates was 79.0 per 100 000 person-years; eight of
17 fractures occurred around metal implants. There was a high incidence
of delayed union and revision surgery. A total of nine patients (ten
AFFs) were available for review at a mean follow-up of 36.5 months
(10 to 104). The clinical outcome was poor with a mean HHS of 58.9
(95% CI 47.4 to 70.4) and a mean TUG test of 25.7 s (95% CI 12.7
to 38.8). The delay in diagnosis and treatment of AFF may result from a
lack of knowledge of this condition. Cite this article:
Management of bisphosphonate-associated subtrochanteric
fractures remains opinion- or consensus-based. There are limited
data regarding the outcomes of this fracture. We retrospectively reviewed 33 consecutive female patients with
a mean age of 67.5 years (47 to 91) who were treated surgically
between May 2004 and October 2009. The mean follow-up was 21.7 months
(0 to 53). Medical records and radiographs were reviewed to determine
the post-operative ambulatory status, time to clinical and radiological
union and post-fixation complications such as implant failure and
need for second surgery. The predominant fixation method was with an extramedullary device
in 23 patients. 25 (75%) patients were placed on wheelchair mobilisation
or no weight-bearing initially. The mean time to full weight-bearing
was 7.1 months (2.2 to 29.7). The mean time for fracture site pain
to cease was 6.2 months (1.2 to 17.1). The mean time to radiological
union was 10.0 months (2.2 to 27.5). Implant failure was seen in
seven patients (23%, 95 confidence interval (CI) 11.8 to 40.9).
Revision surgery was required in ten patients (33%, 95 CI 19.2 to
51.2). A large proportion of the patients required revision surgery
and suffered implant failure. This fracture is associated with slow
healing and prolonged post-operative immobility. Cite this article:
Since the Oxford knee was first used unicompartmentally
in 1982, a small number of bearings have fractured. Of 14 retrieved
bearings, we examined ten samples with known durations
Surgeons remain concerned that ceramic hip prostheses may fail catastrophically if either the head or the liner is fractured. We report two patients, each with a ceramic-on-ceramic total hip replacement who sustained high-energy trauma sufficient to cause a displaced periprosthetic acetabular fracture in whom the ceramic bearings survived intact. Simultaneous fixation of the acetabular fracture, revision of the cementless acetabular prosthesis and exchange of the ceramic bearings were performed successfully in both patients. Improved methods of manufacture of new types of alumina ceramic with a smaller grain size, and lower porosity, have produced much stronger bearings. Whether patients should be advised to restrict high-impact activities in order to protect these modern ceramic bearings from fracture remains controversial.
The August 2013 Trauma Roundup360 looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in tibial plateau fractures; it’s all about the radius of curvature; radius of curvature revisited; radial head replacement in complex elbow reconstruction; stem cells in early fracture haematoma; heterotrophic ossification in forearms; and Boston in perspective.
We describe the routine imaging practices of
Level 1 trauma centres for patients with severe pelvic ring fractures, and
the interobserver reliability of the classification systems of these
fractures using plain radiographs and three-dimensional (3D) CT
reconstructions. Clinical and imaging data for 187 adult patients
(139 men and 48 women, mean age 43 years (15 to 101)) with a severe
pelvic ring fracture managed at two Level 1 trauma centres between July
2007 and June 2010 were extracted. Three experienced orthopaedic
surgeons classified the plain radiographs and 3D CT reconstruction
images of 100 patients using the Tile/AO and Young–Burgess systems.
Reliability was compared using kappa statistics. A total of
115 patients (62%) had plain radiographs as well as two-dimensional
(2D) CT and 3D CT reconstructions, 52 patients (28%) had plain films
only, 12 (6.4%) had 2D and 3D CT reconstructions images only, and
eight patients (4.3%) had no available images. The plain radiograph
was limited to an anteroposterior pelvic view. Patients without
imaging, or only plain films, were more severely injured. A total
of 72 patients (39%) were imaged with a pelvic binder Interobserver reliability for the Tile/AO (Kappa 0.10 to 0.17)
and Young–Burgess (Kappa 0.09 to 0.21) was low, and insufficient
for clinical and research purposes. Severe pelvic ring fractures are difficult to classify due to
their complexity, the increasing use of early treatment such as
with pelvic binders, and the absence of imaging altogether in important
patient sub-groups, such as those who die early of their injuries. Cite this article:
Specific radiological features identified by Brandser and Marsh were selected for the analysis of acetabular fractures according to the classification of Letournel and Judet. The method employs a binary approach that requires the observer to allocate each radiological feature to one of two groups. The inter- and intra-observer variances were assessed. The presence of articular displacement, marginal impaction, incongruity, intra-articular fragments and osteochondral injuries to the femoral head were analysed by a similar method. These factors were termed ‘modifiers’ and are generally considered when planning operative intervention and, critically, they may influence prognosis. Six observers independently assessed 30 sets of plain radiographs and CT scans on two separate occasions, 12 weeks apart. They were asked to determine the presence or absence of specific radiological features. This simple binary approach to classification yields an inter- and intra-observer agreement which ranges from moderate to near-perfect (κ = 0.49 to 0.88 and κ = 0.57 to 0.88, respectively). A similar approach to the modifiers yields only slight to fair inter-observer agreement (κ = 0.20 to 0.34) and slight to moderate intra-observer agreement (κ = 0 to 0.55).
Unstable pelvic injuries in young children with
an immature pelvis have different modes of failure from those in adolescents
and adults. We describe the pathoanatomy of unstable pelvic injuries
in these children, and the incidence of associated avulsion of the
iliac apophysis and fracture of the ipsilateral fifth lumbar transverse
process (L5-TP). We retrospectively reviewed the medical records
of 33 children with Tile types B and C pelvic injuries admitted
between 2007 and 2014; their mean age was 12.6 years (2 to 18) and
12 had an immature pelvis. Those with an immature pelvis commonly
sustained symphyseal injuries anteriorly with diastasis, rather
than the fractures of the pubic rami seen in adolescents. Posteriorly,
transsacral fractures were more commonly encountered in mature children,
whereas sacroiliac dislocations and fracture-dislocations were seen
in both age groups. Avulsion of the iliac apophysis was identified
in eight children, all of whom had an immature pelvis with an intact
ipsilateral L5-TP. Young children with an immature pelvis are more
susceptible to pubic symphysis and sacroiliac diastasis, whereas
bony failures are more common in adolescents. Unstable pelvic injuries
in young children are commonly associated with avulsion of the iliac
apophysis, particularly with displaced SI joint dislocation and
an intact ipsilateral L5-TP. Cite this article:
With the development of systems of trauma care the management of pelvic disruption has evolved and has become increasingly refined. The goal is to achieve an anatomical reduction and stable fixation of the fracture. This requires adequate visualisation for reduction of the fracture and the placement of fixation. Despite the advances in surgical approach and technique, the functional outcomes do not always produce the desired result. New methods of percutaneous treatment in conjunction with innovative computer-based imaging have evolved in an attempt to overcome the existing difficulties. This paper presents an overview of the technical aspects of percutaneous surgery of the pelvis and acetabulum.
Patella infera can cause knee pain and lead to patellofemoral osteoarthritis. Treatment is usually unsatisfactory. We describe a case of severe patella infera after operative treatment for fracture of the patella. We used Ilizarov external fixation and gradual lengthening of the patellar tendon. The patellar height was restored and the patient’s symptoms were much improved.
This study was designed to test the hypothesis
that the sensory innervation of bone might play an important role
in sensing and responding to low-intensity pulsed ultrasound and
explain its effect in promoting fracture healing. In 112 rats a
standardised mid-shaft tibial fracture was created, supported with
an intramedullary needle and divided into four groups of 28. These
either had a sciatic neurectomy or a patellar tendon resection as
control, and received the ultrasound or not as a sham treatment.
Fracture union, callus mineralisation and remodelling were assessed using
plain radiography, peripheral quantitative computed tomography and
histomorphology. Daily ultrasound treatment significantly increased the rate of
union and the volumetric bone mineral density in the fracture callus
in the neurally intact rats (p = 0.025), but this stimulating effect
was absent in the rats with sciatic neurectomy. Histomorphology
demonstrated faster maturation of the callus in the group treated
with ultrasound when compared with the control group. The results
supported the hypothesis that intact innervation plays an important
role in allowing low-intensity pulsed ultrasound to promote fracture
healing.
We hypothesised that the use of pulsed electromagnetic
field (PEMF) bone growth stimulation in acute scaphoid fractures
would significantly shorten the time to union and reduce the number
of nonunions in a randomised, double-blind, placebo-controlled multicentre
trial. A total of 102 patients (78 male, 24 female; mean age 35
years (18 to 77)) from five different medical centres with a unilateral
undisplaced acute scaphoid fracture were randomly allocated to PEMF
(n = 51) or placebo (n = 51) and assessed with regard to functional
and radiological outcomes (multiplanar reconstructed CT scans) at
6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing
did not differ significantly between the active PEMF group and the
placebo group. We concluded that the addition of PEMF bone growth
stimulation to the conservative treatment of acute scaphoid fractures
does not accelerate bone healing. Cite this article:
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean Oxford shoulder score (OSS) of the original
TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean
OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival
using re-intervention for any reason as the endpoint was 91% (95%
confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at
one and five years, respectively. There were two revisions for dislocation of the humeral head,
one open reduction for modular humeral component dissociation, one
internal fixation for nonunion, one trimming of a prominent screw
and one re-cementation for aseptic loosening complicated by infection,
ultimately requiring excision arthroplasty. Two patients sustained
nerve palsies. Revision TSR after a peri-prosthetic humeral fracture associated
with bone loss and/or loose components is a salvage procedure that
can provide a stable platform for elbow and hand function. Good
rates of union can be achieved using a stem that bypasses the fracture.
There is a high rate of complications and function is not as good as
with the original replacement.