Advertisement for orthosearch.org.uk
Results 61 - 80 of 600
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 637 - 639
1 Jul 1993
Rahman H Fagg P

We reviewed 55 patients (78 feet) who had undergone silicone hemiarthroplasty of the first metatarsophalangeal joint for hallux valgus (40) or hallux rigidus (38). At a mean period of 4.5 years (1 to 11), 56 feet had radiological evidence suggestive of silicone granulomatous disease. The frequency and severity of the changes increased with time from the operation. Histological material from three revisions confirmed the presence of silicone granulomata. We recommend that the operation of silicone hemiarthroplasty for hallux valgus and hallux rigidus be abandoned


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 217 - 219
1 Mar 2004
Kralinger F Schwaiger R Wambacher M Farrell E Menth-Chiari W Lajtai G Hübner C Resch H

We have examined 167 patients who had a hemiarthroplasty for three- and four-part fractures and fracture-dislocations of the head of the humerus in a multicentre study involving 12 Austrian hospitals. All patients were followed for more than a year. Anatomical healing of the tuberosity significantly influenced the outcome as measured by the Constant score and subjective patient satisfaction. With regard to pain, the outcome was generally satisfactory but only 41.9% of patients were able to flex the shoulder above 90°. The age of the patient and the type of prosthesis significantly influenced the healing of the tuberosity, but bone grafting did not. Achievement of healing of the tuberosity was inferior in institutions at which less than 15 hemiarthroplasties had been performed (Mann-Witney U test, p = 0.0001)


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 891 - 894
1 Nov 1994
Hui A Anderson G Choudhry R Boyle J Gregg P

We compared the reoperation rate after internal fixation for minimally displaced or impacted intracapsular fractures of the femoral neck in patients aged 80 years and above with that in similar patients aged 65 to 79 years. We also compared the results of internal fixation with those of hemiarthroplasty for displaced intracapsular fracture in an age- and sex-matched group of elderly patients. We found that a significantly greater proportion of the older patients treated by internal fixation required reoperation than either the younger group or the age-matched group treated by hemiarthroplasty. Our results indicate that internal fixation may not be the best treatment for extremely elderly patients with minimally displaced or impacted intracapsular fractures of the femoral neck


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 609 - 615
1 May 2013
Cadossi M Chiarello E Savarino L Tedesco G Baldini N Faldini C Giannini S

We undertook a randomised controlled trial to compare bipolar hemiarthroplasty (HA) with a novel total hip replacement (THR) comprising a polycarbonate–urethane (PCU) acetabular component coupled with a large-diameter metal femoral head for the treatment of displaced fractures of the femoral neck in elderly patients. Functional outcome, assessed with the Harris hip score (HHS) at three months and then annually after surgery, was the primary endpoint. Rates of revision and complication were secondary endpoints. Based on a power analysis, 96 consecutive patients aged > 70 years were randomised to receive either HA (49) or a PCU-THR (47). The mean follow-up was 30.1 months (23 to 50) and 28.6 months (22 to 52) for the HA and the PCU group, respectively. The HHS showed no statistically significant difference between the groups at every follow-up. Higher pain was recorded in the PCU group at one and two years’ follow-up (p = 0.006 and p = 0.019, respectively). In the HA group no revision was performed. In the PCU-THR group six patients underwent revision and one patient is currently awaiting re-operation. The three-year survival rate of the PCU-THR group was 0.841 (95% confidence interval 0.680 to 0.926). Based on our findings we do not recommend the use of the PCU acetabular component as part of the treatment of patients with fractures of the femoral neck. Cite this article: Bone Joint J 2013;95-B:609–15


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 658 - 660
1 Jun 2020
Judge A Metcalfe D Whitehouse MR Parsons N Costa M


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 357 - 361
1 Aug 1981
Sikorski J Barrington R

A prospective randomised trial of surgical treatment for the displaced subcapital femoral fracture in patients of 70 years or more is presented. Two hundred and eighteen patients were randomly allocated into one of three treatment groups: manipulative reduction and internal fixation using Garden screws; Thompson hemiarthroplasty through a posterior (Moore) approach; and Thompson hemiarthroplasty through an anterolateral (McKee) approach. There is no significant difference in the mortality of the internal fixation and posterior arthroplasty groups. Both groups showed a significantly higher mortality than patients operated on through the anterior approach. The technical results of operation were worse in the internally fixed group, with only 40 per cent being satisfactory. Mobilisation was best achieved after the posterior approach. It is concluded that Thompson hemiarthroplasty, using an anterolateral approach, is the safest operation in this group of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 592 - 597
1 Aug 1984
Cruess R Kwok D Duc P Lecavalier M Dang G

Hemiarthroplasty of the hip and some other joints has been used for many years with satisfactory results, but the fate of articular cartilage when weight-bearing against metal has not been reported. Replacement of the head of the femur was carried out in one hip of each of 26 dogs, and the changes in acetabular cartilage studied at intervals of up to 24 weeks. There was early loss of proteoglycan, followed by surface damage to the cartilage, progressive degenerative changes, and growth of pannus from the articular margins. At 24 weeks after operation there was little remaining articular cartilage, while intense subchondral activity suggested that the bony skeleton was being remodelled to conform to the shape of the prosthesis. This study is not intended to suggest that hemiarthroplasty does not help patients


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 788 - 793
1 Sep 1990
Wetherell R Hinves B

In a 10-year prospective study, 561 displaced subcapital fractures of the femoral neck in 546 patients were treated with the Hastings bipolar hemiarthroplasty. Within six months of their operations, 148 patients had died. In 322 hips followed up, 243 with adequate serial radiographs separated by more than one year, only 14 (5.6%) showed acetabular erosion. A group of 91 had been reviewed for between three and nine years (mean, 4 years 10 months) and of these, 95% had no pain or slight pain only. Comparison with an earlier series of conventional hemiarthroplasties reported from this institution showed that the clinical results were similar, but that the erosion rate had been halved


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 112 - 118
1 Feb 1973
Hastings DE Hewitson WA

1. Of fifty consecutive double hemiarthroplasties of the knee for rheumatoid arthritis using Maclntosh prostheses, forty-six were available for detailed assessment in thirty-six patients after one to six years. 2. Two early deaths were related to the operation but two late deaths were not. Three knees required revision, one of them twice. 3. The late results were 87 per cent good and 13 per cent fair. No patients followed up were the same as previously or worse. Every patient stated that he would have the operation performed again. 4. In our experience this operation in carefully selected patients produces satisfactory results. It is essential that great care is given to the operative technique


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 902 - 907
1 Nov 1991
Llinas A Sarmiento A Ebramzadeh E Gogan W McKellop H

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to 20 years). The performance of the secondary total hip replacements varied with the preceding implant and was different for acetabular and femoral components. The incidence of radiological loosening was higher for femoral components implanted after failed hemiarthroplasties and for acetabular components after failed mould arthroplasties. However, the incidence of continuous radiolucent lines was lower for the acetabular components of converted hemiarthroplasties than for the primary replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 922 - 930
1 Aug 2003
Ushio K Oka† M Hyon S Yura S Toguchida J Nakamura T

The use of a composite osteochondral device for simulating partial hemiarthroplasty was examined. The device was composed of a polyvinyl alcohol hydrogel and a titanium fibre mesh, acting as artificial cartilage and as porous artificial bone, respectively. The titanium fibre mesh was designed to act as an interface material, allowing firm attachment to both the polyvinyl alcohol gel (through injection moulding) and the femoral joint surface (through bony ingrowth). We implanted 22 of these devices into canine femoral heads. Histological findings from the acetabular cartilage and synovial membrane, as well as the attachment of the prosthesis to bone, were examined up until one year after operation. No marked pathological changes were found and firm attachment of the device to the underlying bone was confirmed. The main potential application for this device is for partial surface replacement of the femoral head after osteonecrosis. Other applications could include articular resurfacing and the replacement of intervertebral discs


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 244 - 255
1 May 1972
MacIntosh DL Hunter GA

1. Hemiarthroplasty is a method of dealing with painful deformities of advanced osteoarthritis and rheumatoid arthritis of the knee. 2. The indications and contra-indications for this procedure are discussed. Careful selection of patients is essential. 3. The technique of operation and management after operation are described. 4. The results of such a procedure, as done by one surgeon, are given. Good results have been obtained in 80 per cent of the osteoarthritic knees and in 69 per cent of the rheumatoid knees. 5. The complications, place of associated operations and value of revision procedures are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 561 - 565
1 Aug 1988
Rietveld A Daanen H Rozing P Obermann W

Fourteen cases of hemiarthroplasty for four-part fractures of the proximal humerus were reviewed. Pain relief was satisfactory, but function was limited, mainly due to loss of glenohumeral abduction despite electromyographic proof of actively contracting abductors in all cases. Analysis of special radiographs of nine cases showed a direct relationship between the clinical results and the "humeral offset", or distance between the geometric centre of the humeral head and the lateral aspect of the greater tuberosity. This offset affects the lever arms of the glenohumeral abductor muscles. The implications for surgical technique and for the design of shoulder prostheses are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 478 - 482
1 May 1989
Rae P Hodgkinson J Meadows T Davies D Hargadon E

Between December 1982 and June 1986, 98 displaced subcapital femoral neck fractures were treated using the Charnley-Hastings bipolar hemiarthroplasty. Although the patients were elderly, often with associated medical problems, the operation was well tolerated and the mortality at one and six months was 14.4% and 24.5% respectively. Fifty-four hips were reviewed after an average follow-up of 33 months; 64.8% of patients had a good or excellent result. The fair or poor results were seen mainly in patients with poor pre-operative mobility and multiple medical problems. A significant cause of morbidity was dislocation (two interprosthetic) which occurred in six hips. There were two cases of deep sepsis but neither patient was fit for further surgery. There were no cases of acetabular erosion requiring revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 548 - 551
1 Nov 1983
Devas M Hinves B

The best treatment for a fractured neck of femur in an old person is considered by many to be replacement hemiarthroplasty which allows the patient to walk immediately on a stable, painless hip. The late results can be marred by acetabular erosion in which the metal head of the prosthesis erodes upwards into the acetabulum to give pain and disability. Here the trial of a new bipolar prosthesis with a dynamic self-aligning outer head is described in 161 fractured necks of femur. No acetabular erosion has been seen with its use over four years


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1150 - 1155
1 Nov 2002
Parker MJ Khan RJK Crawford J Pryor GA

A total of 455 patients aged over 70 years with a displaced intracapsular fracture of the proximal femur was randomised to be treated either by hemiarthroplasty or internal fixation. The preoperative characteristics of the patients in both groups were similar. Internal fixation has a shorter length of anaesthesia (36 minutes versus 57 minutes, p < 0.0001), lower operative blood loss (28 ml versus 177 ml, p < 0.0001) and lower transfusion requirements (0.04 units versus 0.39 units, p < 0.0001). In the internal fixation group 90 patients required 111 additional surgical procedures while only 15 additional operations on the hip were needed in 12 patients in the arthroplasty group. There was no statistically significant difference in mortality between the groups at one year (61/226 versus 63/229, p = 0.91), but there was a tendency for an improved survival in the older less mobile patients treated by internal fixation. For the survivors assessed at one, two and three years from injury there were no differences with regard to the outcome for pain and mobility. Limb shortening was more common after internal fixation (7.0 mm versus 3.6 mm, p = 0.004). We recommend that displaced intracapsular fractures in the elderly should generally be treated by arthroplasty but that internal fixation may be appropriate for those who are very frail


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 456 - 459
1 May 1995
Christie J Robinson C Singer B Ray D

We randomised 24 patients before they had a cemented hemiarthroplasty for hip fracture to receive either thorough or minimal saline lavage of the femoral canal. We then determined the effect in each group on the thromboembolic and cardiopulmonary responses to the pressurised insertion of cement, using transoesophageal echocardiography to show the echogenic embolic response. We found a statistically significant reduction in both the duration of the response and the number of large emboli in patients who had had thorough lavage as compared with the control group with minimal lavage. There was also less disturbance of pulmonary function, as assessed by the change in end-tidal CO2 levels and oxygen saturation, in patients who had thorough lavage. Three patients had a significant fall in blood pressure during cement insertion; all had only minimal lavage. We consider that thorough lavage should be an essential part of the preparation of the proximal femur before cement insertion


Bone & Joint Open
Vol. 1, Issue 3 | Pages 13 - 18
1 Mar 2020
Png ME Fernandez MA Achten J Parsons N McGibbon A Gould J Griffin X Costa ML

Aim

This paper describes the methods applied to assess the cost-effectiveness of cemented versus uncemented hemiarthroplasty among hip fracture patients in the World Hip Trauma Evaluation Five (WHiTE5) trial.

Methods

A within-trial cost-utility analysis (CUA) will be conducted at four months postinjury from a health system (National Health Service and personal social services) perspective. Resource use pertaining to healthcare utilization (i.e. inpatient care, physiotherapy, social care, and home adaptations), and utility measures (quality-adjusted life years) will be collected at one and four months (primary outcome endpoint) postinjury; only treatment of complications will be captured at 12 months. Sensitivity analysis will be conducted to assess the robustness of the results.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 92 - 95
1 Jan 2019
Harris IA Cuthbert A de Steiger R Lewis P Graves SE

Aims

Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or total hip arthroplasty (THA), with recent recommendations advising that THA be used in community-ambulant patients. This study aims to determine the association between the proportion of FNF treated with THA and year of surgery, day of the week, surgeon practice, and private versus public hospitals, adjusting for known confounders.

Patients and Methods

Data from 67 620 patients in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1999 to 2016 inclusive were used to generate unadjusted and adjusted analyses of the associations between patient, time, surgeon and institution factors, and the proportion of FNF treated with THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 775 - 778
1 Sep 1992
Stranks G MacKenzie N Grover M Fail T

We performed a prospective randomised controlled trial of the A-V Impulse System in 82 patients treated by hemiarthroplasty for subcapital fracture of the femoral neck. The incidence of proximal deep-vein thrombosis as assessed by Doppler ultrasonography was 23% in the control group and 0% in those using the device (p less than 0.01). Calf and thigh circumferences were measured in both groups at seven to ten days after operation. In the treatment group there was a mean relative reduction of postoperative swelling of the thigh by 3.27 cm (p less than 0.001) and of the calf by 1.55 cm (p less than 0.001). The A-V Impulse System appears to be a safe and effective method of reducing the incidence of proximal deep-vein thrombosis, and of postoperative swelling