Advertisement for orthosearch.org.uk
Results 61 - 74 of 74
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 7 - 10
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Most hip fractures treated with modern internal fixation techniques will heal. However, failures occasionally occur and require revision procedures. Salvage strategies employed during revision are based on whether the fixation failure occurs in the femoral neck, or in the intertrochanteric region. Patient age and remaining bone stock also influence decision making. For fractures in young patients, efforts are generally focused on preserving the native femoral head via osteotomies and repeat internal fixation. For failures in older patients, some kind of hip replacement is usually selected. Disuse osteopenia, deformity, bone loss, and stress-risers from previous internal fixation devices all pose technical challenges to successful reconstruction. Attention to detail is important in order to minimise complications. In the majority of cases, good outcomes have been reported for the various salvage strategies.

Cite this article: Bone Joint J 2013;95-B, Supple A:7–10.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1538 - 1543
1 Nov 2013
Kendrick BJL Wilson HA Lippett JE McAndrew AR Andrade AJMD

The National Institute for Health and Clinical Excellence (NICE) guidelines from 2011 recommend the use of cemented hemi-arthroplasty for appropriate patients with an intracapsular hip fracture. In our institution all patients who were admitted with an intracapsular hip fracture and were suitable for a hemi-arthroplasty between April 2010 and July 2012 received an uncemented prosthesis according to our established departmental routine practice. A retrospective analysis of outcome was performed to establish whether the continued use of an uncemented stem was justified. Patient, surgical and outcome data were collected on the National Hip Fracture database. A total of 306 patients received a Cathcart modular head on a Corail uncemented stem as a hemi-arthroplasty. The mean age of the patients was 83.3 years (sd 7.56; 46.6 to 94) and 216 (70.6%) were women. The mortality rate at 30 days was 5.8%. A total of 46.5% of patients returned to their own home by 30 days, which increased to 73.2% by 120 days. The implant used as a hemi-arthroplasty for intracapsular hip fracture provided satisfactory results, with a good rate of return to pre-injury place of residence and an acceptable mortality rate. Surgery should be performed by those who are familiar with the design of the stem and understand what is required for successful implantation.

Cite this article: Bone Joint J 2013;95-B:1538–43.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1701 - 1702
1 Dec 2005
TIDERMARK J


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 502 - 508
1 Apr 2006
Robinson CM Khan LAK Akhtar MA

Over a seven-year period we treated a consecutive series of 58 patients, 20 men and 38 women with a mean age of 66 years (21 to 87) who had an acute complex anterior fracture-dislocation of the proximal humerus. Two patterns of injury are proposed for study based upon a prospective assessment of the pattern of soft-tissue and bony injury and the degree of devascularisation of the humeral head. In 23 patients, the head had retained capsular attachments and arterial back-bleeding (type-I injury), whereas in 35 patients the head was devoid of significant soft-tissue attachments with no active arterial bleeding (type-II injury).

Following treatment by open reduction and internal fixation, only two of 23 patients with type-I injuries developed radiological evidence of osteonecrosis of the humeral head, compared with four of seven patients with type-II injuries.

A policy of primary treatment by open reduction and internal fixation of type-I injuries is justified, whereas most elderly patients (aged 60 years or over) with type-II injuries are best treated by hemiarthroplasty. The best treatment for younger patients (aged under 60 years) who sustain type-II injuries is controversial and an individualised approach to their management is advocated.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 811 - 816
1 Jun 2011
Duckworth AD Bennet SJ Aderinto J Keating JF

The aim of this study was to determine the comorbid risk factors for failure in young patients who undergo fixation of a displaced fracture of the femoral neck. We identified from a prospective database all such patients ≤ 60 years of age treated with reduction and internal fixation. The main outcome measures were union, failure of fixation, nonunion and the development of avascular necrosis.

There were 122 patients in the study. Union occurred in 83 patients (68%) at a mean follow-up of 58 months (18 to 155). Complications occurred in 39 patients (32%) at a mean of 11 months (0.5 to 39). The rate of nonunion was 7.4% (n = 9) and of avascular necrosis was 11.5% (n = 14). Failures were more common in patients over 40 years of age (p = 0.03). Univariate analysis identified that delay in time to fixation (> 24 hours), alcohol excess and pre-existing renal, liver or respiratory disease were all predictive of failure (all p < 0.05). Of these, alcohol excess, renal disease and respiratory disease were most predictive of failure on multivariate analysis.

Younger patients with fractures of the femoral neck should be carefully evaluated for comorbidities that increase the risk of failure after reduction and fixation. In patients with a history of alcohol abuse, renal or respiratory disease, arthroplasty should be considered as an alternative treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1519 - 1521
1 Nov 2007
Khunda A Stirrat AN Dunlop P

The proximal humerus internal locking system is an internal fixation device consisting of a low-profile plate and locking screws, which is used for the fixation of three- and four-part fractures of the proximal humerus. We describe a case in which the screws cut out of the humeral head causing injury to the axillary artery necessitating urgent removal of the implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 730 - 733
1 Jun 2006
Quinlan JF O’Shea K Doyle F Brady OH

The in-cement technique for revision hip arthroplasty involves retaining the original cement-bone interface. This has been proven to be a biomechanically stronger method than recementing after complete removal of the original cement mantle.

This study reviewed a series of 54 consecutive revision hip arthroplasty procedures, using the in-cement technique, between November 1999 and November 2003. Clinical and radiological follow-up included functional assessment.

There were 54 procedures performed in 51 patients, whose mean age at surgery was 70.3 years (45 to 85). A total of 42 were available at a mean follow-up of 29.2 months (6 to 51). There was no radiological evidence of loosening. Functional assessments were available for 40 patients who had a mean Harris hip score of 85.2 (51.9 to 98.5), a mean Oxford hip score of 19.6 (12 to 41), a mean UCLA activity profile score of 5.9 (3 to 8) and a mean SF-36 score of 78.0 (31.6 to 100).

The in-cement technique provides consistent, high functional outcomes and should be considered in appropriately selected cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1617 - 1621
1 Dec 2005
O’Shea K Quinlan JF Kutty S Mulcahy D Brady OH

We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with femoral revision using an uncemented extensively porous-coated implant. A retrospective clinical and radiographic assessment of 22 patients with a mean follow-up of 33.7 months was performed. The mean time from the index procedure to fracture was 10.8 years. There were 17 patients with a satisfactory result. Complications in four patients included subsidence in two, deep sepsis in one, and delayed union in one. Concomitant acetabular revision was required in 19 patients. Uncemented extensively porous-coated femoral stems incorporate distally allowing stable fixation. We found good early survival rates and a low incidence of nonunion using this implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss.

We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1344 - 1351
1 Oct 2005
Field RE Rushton N

The Cambridge Cup has been designed to replace the horseshoe-shaped articular cartilage of the acetabulum and the underlying subchondral bone. It is intended to provide physiological loading with minimal resection of healthy bone.

The cup has been used in 50 women with displaced, subcapital fractures of the neck of the femur. In 24 cases, the cup was coated with hydroxyapatite. In 26, the coating was removed before implantation in order to simulate the effect of long-term resorption.

The mean Barthel index and the Charnley-modified Merle d’Aubigné scores recovered to their levels before fracture. We reviewed 30 women at two years, 21 were asymptomatic and nine reported minimal pain. The mean scores deteriorated slightly after five years reflecting the comorbidity of advancing age. Patients with the hydroxyapatite-coated components remained asymptomatic, with no wear or loosening. The uncoated components migrated after four years and three required revision. This trial shows good early results using a novel, hydroxyapatite-coated, physiological acetabular component.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1669 - 1677
1 Dec 2010
Thakar C Alsousou J Hamilton TW Willett K

We evaluated the cost and consequences of proximal femoral fractures requiring further surgery because of complications. The data were collected prospectively in a standard manner from all patients with a proximal femoral fracture presenting to the trauma unit at the John Radcliffe Hospital over a five-year period. The total cost of treatment for each patient was calculated by separating it into its various components. The risk factors for the complications that arose, the location of their discharge and the mortality rates for these patients were compared to those of a matched control group. There were 2360 proximal femoral fractures in 2257 patients, of which 144 (6.1%) required further surgery. The mean cost of treatment in patients with complications was £18 709 (£2606.30 to £60.827.10), compared with £8610 (£918.54 to £45 601.30) for uncomplicated cases (p < 0.01), with a mean length of stay of 62.8 (44.5 to 79.3) and 32.7 (23.8 to 35.0) days, respectively. The probability of mortality after one month in these cases was significantly higher than in the control group, with a mean survival of 209 days, compared with 496 days for the controls. Patients with complications were statistically less likely to return to their own home (p < 0.01).

Greater awareness and understanding are required to minimise the complications of proximal femoral fractures and consequently their cost.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 949 - 950
1 Jul 2006
Lloyd JM Calder JDF

The Thompson hemiarthroplasty is a popular hip prosthesis. We present two case reports highlighting a significant alteration in the design of the implant which compromised the success of the operations.

In recent years the manufacturing process of this prosthesis has changed, with a resultant increase in the volume of the stem of 10 ml.

It is essential that manufacturers inform orthopaedic surgeons of any alteration in the design of the implant and supply compatible instrumentation to minimise surgical errors. Surgeons must remain vigilant when checking the compatibility of the trial and definitive prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 608 - 617
1 May 2005
Bauer HCF