1. Eighty consecutive open fractures of the tibial
The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the
We studied 47 patients with closed, displaced, diaphyseal fractures of the femur caused by blunt trauma, to determine the incidence of associated knee injuries, particularly of the meniscus. After femoral nailing, all patients had an examination under anaesthesia and an arthroscopy. There were 12 medial meniscal injuries (5 tears) and 13 injuries of the lateral meniscus (8 tears). Ten of the 13 tears were in the posterior third of the meniscus, and two patients had tears of both menisci. Synovitis was common at the meniscal attachments. Complex and radial tears were more common than peripheral or bucket-handle tears. Examination under anaesthesia revealed ligamentous laxity in 23 patients (49%), but meniscal injuries had a similar incidence in knees with and without ligament injury. Femoral
We have treated 42 consecutive complex ununited fractures of the femoral
We describe the use of intramedullary reconstruction nails in the treatment of 14 patients with pathological subtrochanteric fractures and coexisting metastases in the femoral
We describe the use of Ender nails for the internal fixation of femoral
Ten patients with humeral
We measured pressures in the anterior and deep posterior compartments continuously for up to 72 hours in 20 patients with closed fractures of the tibial
The stability of union following the conservative treatment of tibial
Sixty patients each of whom had a fracture of the lower limb a minimum of five years (median 11 years) previously were studied by photoplethysmography, foot volumetry, popliteal venous reflux and arterial Doppler measurements. The non-fractured limb was used as a control. Postphlebitic symptoms were present in 51% and signs in 49% of fractured limbs compared with 4% and 24% respectively in the control limbs. The incidence was greater in patients who had fractured 15 years or more previously than in those who had fractured 5 to 15 years previously. Eleven limbs had clinically disabling postphlebitic symptoms including venous ulceration. The postphlebitic syndrome following lower limb fractures in young patients is more common than generally appreciated and develops after a prolonged latent interval. A prospective randomised study using prophylactic anticoagulation for lower limb
In a prospective study, we randomly allocated 39 patients with isolated fractures of the lower two-thirds of the ulnar
A prospective study of 141 patients with 143 tibial
We have reviewed our recent results with functional bracing of tibial
We have reviewed 402 traumatic fractures of the femoral
We reviewed and radiographed 30 skeletally-mature patients after isolated closed femoral
One hundred and two fractures of the femoral
Over 15 years (1967 to 1982) 140 uncomplicated femoral
We report our experience with a modified implant and a new technique for locked intramedullary nailing of the humerus in 41 patients. Locking was by cross-screws placed from lateral to medial in the proximal humerus, and anteroposteriorly in the distal humerus. Early in the series, 11 nails were inserted at the shoulder, but we found that rehabilitation was faster after retrograde nailing through the olecranon fossa, which was used for the other 30. We used a closed technique for 29 of the nailings. Of the 41 patients treated, 21 had acute fractures, five had nonunion, and 15 had pathological fractures. Secure fixation was obtained for comminuted and osteoporotic fractures in any part of the humeral
The use of two implants to manage concomitant ipsilateral femoral
shaft and proximal femoral fractures has been indicated, but no
studies address the relationship of dynamic hip screw (DHS) side
plate screws and the intramedullary nail where failure might occur
after union. This study compares different implant configurations
in order to investigate bridging the gap between the distal DHS
and tip of the intramedullary nail. A total of 29 left synthetic femora were tested in three groups:
1) gapped short nail (GSN); 2) unicortical short nail (USN), differing
from GSN by the use of two unicortical bridging screws; and 3) bicortical
long nail (BLN), with two angled bicortical and one unicortical bridging
screws. With these findings, five matched-pairs of cadaveric femora
were tested in two groups: 1) unicortical long nail (ULN), with
a longer nail than USN and three bridging unicortical screws; and
2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally
rotated 90°/sec until failure.Objectives
Methods
1. A series of 705 fractures of the tibia is reviewed, 674 of which were treated conservatively. 2. The factors most conducive to delayed or non-union are initial displacement, comminution, associated soft-tissue wound and infection. The extent to which these are combined in any fracture determines its "personality" and its inherent propensity for union. 3. Eight fracture types are differentiated based on the above "personality rating." The incidence of delayed union or non-union varies from 9 per cent in the most favourable type to 39 per cent in the least favourable. Infection raises the incidence to 60 per cent. Comparative statistics which fail to recognise these differences can be entirely misleading. 4. Continuous traction does not retard union. 5. The results of conservative treatment are analysed with regard to union, deformity, stiff joints and contractures and the conclusion is reached that no case has yet been made out for internal fixation as the method of choice in the treatment of this fracture.