Advertisement for orthosearch.org.uk
Results 61 - 80 of 1108
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 2 | Pages 155 - 158
1 May 1979
Rybka V Raunio P Vainio K

Forty-one arthrodeses of the shoulder in thirty-nine patients suffering from rheumatoid arthritis (thirty women, nine men) have been reviewed. Using internal fixation and external splints the position of the shoulder was maintained in 55 degrees of abduction, 25 degrees of horizontal flexion and enough internal rotation to allow the patient to reach the mouth. The mean period of immobilisation in a thoracobrachial splint was nine weeks, and 90 per cent of the shoulders had solid bony fusion at review. After arthrodesis the total range of scapulothoracic movement improved by about 60 per cent, giving results rated as excellent in fifteen cases (36 per cent), as good in thirteen (32 per cent) and as fair in thirteen (32 per cent). Arthrodesis can be recommended as an easy, cheap and reliable method of treating a shoulder which has been severely destroyed by rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 732 - 736
1 Nov 1984
Johnson Getty C Lettin A Glasgow M

Between 1970 and 1982, 50 total elbow replacements were carried out for rheumatoid arthritis using the Stanmore prosthesis. A long-term follow-up of the 44 elbows available for review is presented. Thirty-four of these (77%) had good results, five were fair, and five were poor. The complications and limitations are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 909 - 911
1 Nov 1994
Raut V Siney P Wroblewski B

We assessed 41 patients with rheumatoid arthritis (47 hips) who had had revision hip arthroplasty, at an average follow-up of 7 years 4 months (2 to 19). The clinical results were excellent or satisfactory in 43 hips. Radiologically, 45 stems were secure. Fifteen sockets (36.6%) were radiologically loose. Three hips required rerevision. Socket failure is the predominant problem in rheumatoid patients after cemented revision arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 350 - 356
1 May 1986
Crockard H Pozo J Ransford A Stevens J Kendall B Essigman W

Cervical myelopathy is an uncommon but potentially fatal complication of rheumatoid atlanto-axial subluxation. Computerised myelotomography with three-dimensional reconstruction shows that rheumatoid pannus, together with the odontoid peg, contributes significantly to anterior cervico-medullary compression. These findings were the basis for treatment by transoral anterior decompression and posterior occipitocervical fusion, which removes both bony and soft-tissue causes of compression and allows early mobilisation without major external fixation. We report encouraging results from this combined approach in 14 patients who had progressive neurological deterioration


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 1 | Pages 69 - 73
1 Feb 1979
Copeland S Taylor J

The results of thirty synovectomies of the elbow for rheumatoid arthritis are reported. Satisfactory relief of pain was obtained in twenty-seven elbows and the range of movement was improved in twenty-one. The classical operation includes excision of the radial head but in this series approximately half the radial heads were conserved with comparable results. The results of synovectomy do not significantly deteriorate with time up to ten years and the operation can be done with good results, especially in respect of relief of pain, even in elbows with relatively advanced rheumatoid disease. Radiographic assessment is not of much help in evaluating the results of the operation, but is essential in selection of elbows for synovectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 604 - 608
1 May 2001
Fink B Berger I Siegmüller C Fassbender H Meyer-Scholten C Tillmann K Rüther W

We evaluated histologically samples of synovial tissue from the knees of 50 patients with rheumatoid arthritis (RA). The samples were taken during revision for aseptic loosening. The findings were compared with those in 64 knees with osteoarthritis (OA) and aseptic loosening and in 18 knees with RA without loosening. The last group had been revised because of failure of the inlay or the coupling system of a constrained prosthesis. All the patients had had a total ventral synovectomy before implantation of the primary prosthesis. In all three groups a foreign-body reaction and lymphocellular infiltration were seen in more than 80% of the tissue samples. Deposits of fibrin were observed in about one-third to one-half of the knees in all groups. Typical signs of the reactivation of RA such as rheumatoid necrosis and/or proliferation of synovial stromal cells were found in 26% of knees with RA and loosening, but not in those with OA and loosening and in those with RA without loosening. Our findings show that reactivation of rheumatoid synovitis occurs after total knee replacement and may be a cofactor in aseptic loosening in patients with RA


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 686 - 690
1 Jul 2001
Jana AK Engh CA Lewandowski PJ Hopper RH Engh CA

We studied the results of total hip arthroplasty (THA) using AML porous-coated femoral components at a mean follow-up of 11 years in a non-selected, consecutive series of patients with rheumatoid arthritis. We reviewed 64 patients with 82 primary THAs using these components. There were seven men (8 hips) and 57 women (74 hips) with a mean age of 55.1 years (24 to 80) at the time of surgery. Nine patients (11 hips) died before the two-year follow-up. Of the remaining 71 hips, only one stem was revised for aseptic loosening. Survivorship for the stems was 98.1% (95% confidence interval (CI) 94.5 to 100.0) at ten years, using a life-table analysis, with revision for any reason as an endpoint. Of the 70 unrevised stems, 66 (94%) had bony ingrowth, while four (6%) were radiologically loose at the most recent follow-up (mean 11.4 years). Our study shows the excellent long-term results which can be achieved with porous-coated femoral components in patients with rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 288 - 292
1 May 1957
Jacobs JH Hess EV Beswick IP

1. Three cases of tenosynovitis presenting as the first manifestation of rheumatoid arthritis are described. 2. An account is given of the histology of the affected tendon sheaths


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 482 - 488
1 Aug 1965
Wilkinson MC Lowry JH

1. The follow-up reports of ninety-one joints affected by rheumatoid arthritis and treated by synovectomy showed that seventy-three joints remained free of pain. Forty-nine out of ninety-one joints retained useful function after a period averaging three and a half years. 2. The average duration of the disease before admission was eight and a half years. 3. The joints causing most distress were selected for operation. Better results might have been obtained if these patients had received constitutional treatment, splintage and synovectomy earlier. Many of these patients had advanced disease which was continuing to advance at the time of their admission, in spite of previous treatment. Many accepted a trial of treatment in a long stay hospital as a last hope. 4. The return of forty-eight out of sixty-two patients to unassisted or nearly unassisted activity and the maintenance of this state in thirty-nine out of fifty-four shows that the success of the pilot scheme conducted in cooperation with Dr W. S. Tegner and Dr R. M. Mason of the London Hospital has been confirmed by further experience


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 510 - 512
1 May 2001
Gill GS Joshi AB

We analysed the long-term results with a mean follow-up of 10.2 years, of 66 total knee replacements in 42 patients with rheumatoid arthritis. In all cases the posterior cruciate ligament was retained. There were only three complications (4.5%). Revision surgery was necessary in five knees (7.6%), including one (1.5%) with infection. At the final follow-up, 75.8% of knees were rated excellent clinically. Only 15% had an excellent function score. The survival rate of the implant was 90.7% at 19 years. The clinical, radiological and survivorship analysis shows that the posterior-cruciate-retaining knee arthroplasty performs well in rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 458 - 470
1 Aug 1973
Rana NA Hancock DO Taylor AR Hill AGS

1. This paper presents the neurological findings in forty-one patients with rheumatoid arthritis complicated by atlanto-axial subluxation. 2. A method of radiological measurement of the subluxation is described. The extent of neurological involvement was found not to correspond with the degree of subluxation. 3. Fusion of the atlanto-axial complex or of the occipito-atlanto-axial complex is indicated only in patients with progressive neurological signs and in those suffering from acute neurological episodes. 4. Difficulty in obtaining fusion with cancellous bone grafts alone was encountered and we recommend wiring of the laminae C.1 to C.2 in addition


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 1 | Pages 70 - 76
1 Feb 1970
Dick WC Shenkin A Freeman P Nuki G Whaley K Buchanan WW

1. . 133. Xe clearance rates as a measure of blood flow were determined in the knees oftwo groups of patients. 2. In the first group eight patients with rheumatoid arthritis were studied before, three months after and one year after synovectomy. Blood flow values were significantly lower three months after operation but the values recorded one year after operation did not differ significantly from those before operation. 3. In the second group (twenty-one patients with rheumatoid arthritis) blood flow values were determined two to three years after synovectomy. The values obtained differed from those obtained in normal joints and fell within the range of values obtained in forty-three patients with rheumatoid arthritis who did not have synovectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 106 - 111
1 Feb 1973
Wilson DW Arden GP Ansell BM

1. Synovectomy of the elbow affected by rheumatoid arthritis is a worthwhile procedure even in the presence of advanced radiological changes. 2. Relief of pain is good (93 per cent) and movement is retained (87 per cent). 3. Although the follow-up in this series was short, averaging nineteen months, the results seem to be maintained. 4. Good access to the joint may be had through medial and lateral incisions, and division of the olecranon is unnecessary. A lateral incision alone is not recommended. 5. The ulnar nerve should be preserved during dissection. Anterior transposition is needed only if there are neurological symptoms before operation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 328 - 332
1 Mar 1998
Kofoed H Sørensen TS

We performed 52 cemented ankle arthroplasties for painful osteoarthritis (OA) (25) or rheumatoid arthritis (RA) (27) using an ankle prosthesis with a near-anatomical design. We assessed the patients radiologically and clinically for up to 14 years using an ankle scoring system. The preoperative median scores were 29 for the OA group and 25 for the RA group and at ten years were 93.5 and 83, respectively. Six ankles in the OA group and five in the RA group required revision or arthrodesis. Survivorship analysis of the two groups showed no significant differences with 72.7% survival for the OA group and 75.5% for the RA group at 14 years


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 783 - 786
1 Sep 1996
Pech J Sosna A Rybka V Pokorný D

Arthrodesis of the wrist is a standard operation which is indicated for severe rheumatoid arthritis in which destruction is too advanced for more conservative procedures, or after failure of previous surgery. We have developed an L-shaped plate designed for this purpose. It provides rigid internal fixation with the wrist in the neutral position and utilises bone grafts obtained from the distal ulna and the carpal bones. We have carried out 29 successful fusions between 1992 and 1995. In all 29 patients synovectomy and resection of the head of the ulna were performed; 11 also had reconstruction of ruptured extensor tendons. All the patients obtained bony union, pain relief and improved function


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 3 | Pages 368 - 371
1 Aug 1980
Blockey N Gibson A Goel K

Seven out of 22 children with monarticular juvenile rheumatoid arthritis (MJRA) developed involvement of other joints between six months and three and a half years from the onset. In the other 15 patients the disease has remained monarticular for between one and 16 years (mean six years). Chronic iridocyclitis was seen in three of the five boys, two with antinuclear antibodies. Children with MJRA and antinuclear antibodies should have periodic ophthalmic assessment. Synovial biopsy was of value primarily in excluding other cases of arthritis, but there was only limited correlation between the histological findings and the subsequent course of the disease


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 955 - 958
1 Jul 2005
Tanaka N Sakahashi H Hirose K Ishima T Takahashi H Ishii S

We evaluated the use of surgical stabilisation for atlantoaxial subluxation after a follow-up of 24 years in 50 rheumatoid patients who had some degree of pain but no major neurological deficit. The mortality of patients treated by atlantoaxial fusion was significantly lower than for those who received conservative treatment. The deaths resulted from infection or comorbid conditions. The significantly high relative risks of mortality from conservative treatment compared with surgical treatment were mutilating disease and susceptible factors on both of the HLA-DRB1 alleles. Relief from pain and neurological and functional recovery were better, and the radiological degree of atlantoaxial translocation was less in those who were surgically treated compared with those who were not. Two patients had superficial local infections after surgery. We conclude that prophylactic atlantoaxial fusion is better than conservative treatment in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1077 - 1080
1 Aug 2005
Sharma S Nicol F Hullin MG McCreath SW

We analysed the long-term clinical and radiological results of 63 uncemented Low Contact Stress total knee replacements in 47 patients with rheumatoid arthritis. At a mean follow-up of 12.9 years (10 to 16), 36 patients (49 knees) were still alive; three patients (five knees) were lost to follow-up. Revision was necessary in three knees (4.8%) and the rate of infection was 3.2%. The mean clinical and functional Knee Society scores were 90 (30 to 98) and 59 (25 to 90), respectively, at final follow-up and the mean active range of movement was 104° (55° to 120°). The survival rate was 94% at 16 years but 85.5% of patients lost to follow-up were considered as failures. Radiological evidence of impending failure was noted in one knee


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 18 - 22
1 Jan 1995
Onsten I Akesson K Besjakov J Obrant K

Migration of 65 Charnley stems implanted with modern cementing techniques was studied by roentgen stereophotogrammetry. There were 25 patients with rheumatoid arthritis (RA) and 40 with osteoarthritis (OA) followed up for two years. In 43 cases a bone sample for histomorphometric analysis was obtained from the femur during the operation. In 22 cases the mean subsidence of the prosthetic head was 0.40 mm and in 20 the mean posterior migration was 1.25 mm. There was no difference in migration between the two diagnostic groups (p = 0.8) after adjusting for variations in gender, age and weight. Male gender was associated with increased subsidence (p = 0.006). Histological examination showed that the RA series had more osteoid surface (p = 0.04), but neither this, nor any of the other histomorphometric variables, influenced migration. These results suggest that, unlike the acetabular socket, the cemented Charnley femoral component is equally secure in osteoarthritis and in rheumatoid arthritis, and that its initial fixation is not influenced by the quality of the local cancellous bone. Our results provide data with which the early performance of new prosthetic designs and fixation methods can be compared


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 507 - 509
1 Aug 1971
Chamberlain MA

1. Eight patients with rheumatoid arthritis had an intra-articular nodule in one or both knees causing mechanical symptoms. 2. The nodule was on the lateral side of the knee and interfered with walking. It caused a click and painful instability of the knee at about 15 degrees of flexion. 3. Surgical excision of the nodule, which was attached to the synovial membrane, abolished the symptoms