Advertisement for orthosearch.org.uk
Results 61 - 80 of 1688
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1500 - 1507
1 Nov 2013
Zaidi R Cro S Gurusamy K Sivanadarajah N Macgregor A Henricson A Goldberg A

We performed a systematic review and meta-analysis of modern total ankle replacements (TARs) to determine the survivorship, outcome, complications, radiological findings and range of movement, in patients with end-stage osteoarthritis (OA) of the ankle who undergo this procedure. We used the methodology of the Cochrane Collaboration, which uses risk of bias profiling to assess the quality of papers in favour of a domain-based approach. Continuous outcome scores were pooled across studies using the generic inverse variance method and the random-effects model was used to incorporate clinical and methodological heterogeneity. We included 58 papers (7942 TARs) with an interobserver reliability (Kappa) for selection, performance, attrition, detection and reporting bias of between 0.83 and 0.98. The overall survivorship was 89% at ten years with an annual failure rate of 1.2% (95% confidence interval (CI) 0.7 to 1.6). The mean American Orthopaedic Foot and Ankle Society score changed from 40 (95% CI 36 to 43) pre-operatively to 80 (95% CI 76 to 84) at a mean follow-up of 8.2 years (7 to 10) (p < 0.01). Radiolucencies were identified in up to 23% of TARs after a mean of 4.4 years (2.3 to 9.6). The mean total range of movement improved from 23° (95% CI 19 to 26) to 34° (95% CI 26 to 41) (p = 0.01). Our study demonstrates that TAR has a positive impact on patients’ lives, with benefits lasting ten years, as judged by improvement in pain and function, as well as improved gait and increased range of movement. However, the quality of evidence is weak and fraught with biases and high quality randomised controlled trials are required to compare TAR with other forms of treatment such as fusion. Cite this article: Bone Joint J 2013;95-B:1500–7


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 64 - 70
1 Jan 2015
Hamilton DF Burnett R Patton JT Howie CR Moran M Simpson AHRW Gaston P

Total knee arthroplasty (TKA) is an established and successful procedure. However, the design of prostheses continues to be modified in an attempt to optimise the functional outcome of the patient. . The aim of this study was to determine if patient outcome after TKA was influenced by the design of the prosthesis used. A total of 212 patients (mean age 69; 43 to 92; 131 female (62%), 81 male (32%)) were enrolled in a single centre double-blind trial and randomised to receive either a Kinemax (group 1) or a Triathlon (group 2) TKA. . Patients were assessed pre-operatively, at six weeks, six months, one year and three years after surgery. The outcome assessments used were the Oxford Knee Score; range of movement; pain numerical rating scales; lower limb power output; timed functional assessment battery and a satisfaction survey. Data were assessed incorporating change over all assessment time points, using repeated measures analysis of variance longitudinal mixed models. Implant group 2 showed a significantly greater range of movement (p = 0.009), greater lower limb power output (p = 0.026) and reduced report of ‘worst daily pain’ (p = 0.003) over the three years of follow-up. Differences in Oxford Knee Score (p = 0.09), report of ‘average daily pain’ (p = 0.57) and timed functional performance tasks (p = 0.23) did not reach statistical significance. Satisfaction with outcome was significantly better in group 2 (p = 0.001). These results suggest that patient outcome after TKA can be influenced by the prosthesis used. Cite this article: Bone Joint J 2015;97-B:64–70


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 475 - 480
1 Apr 2009
Matsumoto T Kuroda R Kubo S Muratsu H Mizuno K Kurosaka M

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0°, 10°, 45°, 90° and 135° of flexion, with the patella both everted and reduced. While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p < 0.05)


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 213 - 220
1 Feb 2019
Xu S Lim WJ Chen JY Lo NN Chia S Tay DKJ Hao Y Yeo SJ

Aims. The aim of this study was to assess the influence of obesity on the clinical outcomes and survivorship ten years postoperatively in patients who underwent a fixed-bearing unicompartmental knee arthroplasty (UKA). Patients and Methods. We prospectively followed 184 patients who underwent UKA between 2003 and 2007 for a minimum of ten years. A total of 142 patients with preoperative body mass index (BMI) of < 30 kg/m. 2. were in the control group (32 male, 110 female) and 42 patients with BMI of ≥ 30 kg/m. 2. were in the obese group (five male, 37 female). Pre- and postoperative range of movement (ROM), Knee Society Score (KSS), Oxford Knee Score (OKS), 36-Item Short-Form Health Survey (SF-36), and survivorship were analyzed. Results. Patients in the obese group underwent UKA at a significantly younger mean age (56.5 years (. sd. 6.4)) than those in the control group (62.4 years (. sd. 7.8); p < 0.001). There was no significant difference in preoperative functional scores. However, those in the obese group had a significantly lower ROM (116° (. sd. 15°) vs 123° (. sd. 17°); p = 0.003). Both groups achieved significant improvement in outcome scores regardless of BMI, ten years postoperatively. All patients achieved the minimal clinically important difference (MCID) for OKS and KSS. Both groups also had high rates of satisfaction (96.3% in the control group and 97.5% in the obese group) and the fulfilment of expectations (94.9% in the control group and 95.0% in the obese group). Multiple linear regression showed a clear association between obesity and a lower OKS two years postoperatively and Knee Society Function Score (KSFS) ten years postoperatively. After applying propensity matching, obese patients had a significantly lower KSFS, OKS, and physical component score (PCS) ten years postoperatively. Seven patients underwent revision to total knee arthroplasty (TKA), two in the control group and five in the obese group, resulting in a mean rate of survival at ten years of 98.6% and 88.1%, respectively (p = 0.012). Conclusion. Both groups had significant improvements in functional and quality-of-life scores postoperatively. However, obesity was a significant predictor of poorer improvement in clinical outcome and an increased rate of revision ten years postoperatively


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1621 - 1625
1 Dec 2011
Donken CCMA Goorden AJF Verhofstad MHJ Edwards MJ van Laarhoven CJHM

We assessed the long-term (20 years) outcome of closed reduction and immobilisation in 19 patients with an isolated fracture of the posterior malleolus of the ankle treated at a single hospital between 1985 and 1990. The assessments used were an Olerud functional questionnaire score, physical examination using a loaded dorsal and plantar range of movement measurement, radiological analysis of medial joint space widening, the Cedell score for anatomical alignment of all three malleoli, and the radiological presence of osteoarthritic change. . There were excellent or good results in 14 patients (74%) according to the Olerud score, in 18 patients (95%) according to loaded dorsal and plantar range of movement assessment, in 16 patients (84%) as judged by the Cedell score, and for osteoarthritis 18 patients (95%) had an excellent or good score. There were no poor outcomes. There was no correlation between the size of the fracture gap and the proportion of the tibiotalar contact area when compared with the clinical results (gap size: rho values -0.16 to 0.04, p ≥ 0.51; tibiotalar contact area: rho values -0.20 to -0.03, p ≥ 0.4). Conservative treatment of ‘isolated’ posterior malleolar fractures resulted in good clinical and radiological outcome in this series at long-term follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1357 - 1360
1 Oct 2005
Hutchinson JRM Parish EN Cross MJ

Stiffness is an uncommon but potentially debilitating complication following total knee replacement (TKR). The treatment of this condition remains difficult and controversial. We present the results of 13 patients who underwent open arthrolysis for stiffness. The mean time between TKR and arthrolysis was 14 months. The mean follow-up was 7.2 years (2 to 10). The mean range of movement prior to arthrolysis was 55°. This increased to 91°, six months after arthrolysis (p < 0.005). The improved range of movement was maintained during the follow-up period. No patient has required revision of their components. We have found arthrolysis to be a useful and successful approach to post-TKR stiffness


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 925 - 929
1 Jul 2018
Abdel MP Tibbo ME Stuart MJ Trousdale RT Hanssen AD Pagnano MW

Aims. It has been suggested that mobile-bearing total knee arthroplasty (TKA) might lead to better outcomes by accommodating some femorotibial rotational mismatch, thereby reducing contact stresses and polyethylene wear. The aim of this study was to determine whether there is a difference between fixed- and mobile-bearing versions of a contemporary TKA with respect to durability, range of movement (ROM) and function, ten years postoperatively. Patients and Methods. A total of 240 patients who were enrolled in this randomized controlled trial (RCT) underwent a primary cemented TKA with one of three tibial components (all-polyethylene fixed-bearing, modular metal-backed fixed-bearing and mobile-bearing). Patients were reviewed at a median follow-up of ten years (IQR 9.2 to 10.4). Results. There was no difference in durability, as measured by survivorship free of revision for any reason, nor in mean maximal ROM at ten years (p = 0.8). There was also no difference in function, as measured by Knee Society (KS) function scores (p = 0.63) or the prevalence of patellar tilt (p = 0.12). Conclusion. In this clinical RCT, the mobile-bearing design of TKA was found to be reliable and durable, but did not provide better maximum knee flexion, function or durability ten years postoperatively compared with a posterior-stabilized, fixed-bearing design incorporating either an all-polyethylene or a modular-metal-backed tibial component. Cite this article: Bone Joint J 2018;100-B:925–9


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 914 - 917
1 Nov 1997
Pope RO Corcoran S McCaul K Howie DW

We report a prospective randomly controlled trial to examine the effectiveness of continuous passive motion (CPM) in improving postoperative function and range of movement after total knee arthroplasty (TKA). We allocated 53 patients (57 knees) to one of three postoperative regimes: no CPM (n = 19); CPM at 0 to 40° (0 to 40 CPM; n = 18); and CPM at 0 to 70° (0 to 70 CPM; n = 20). Those in the CPM groups had CPM for 48 hours and all patients had an identical regime of physiotherapy. There was an even distribution of various cemented and cementless TKAs in each group. Patients were assessed preoperatively and at one week and at one year postoperatively. At one week, there was a statistically significant increase in the range of flexion and total range of movement in the 0 to 70 CPM group compared with the no-CPM group. At one year we found no significant differences in mean flexion, overall range of movement, fixed flexion deformity or functional results in the three groups. Those who had CPM had a significant increase in analgesic requirement (p = 0.04). There was an increased mean blood drainage postoperatively in those who had 0 to 70 CPM (1558 ml) compared with those with no CPM (956 ml) (t = 2.96, p = 0.005) and with 0 to 40 CPM (1017 ml) (t = 2.62, p = 0.01). Our findings show that CPM had no significant advantage in terms of improving function or range of movement, and that its use increased blood loss and analgesic requirements


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1214 - 1221
1 Sep 2008
Egol K Walsh M Tejwani N McLaurin T Wynn C Paksima N

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1213 - 1216
1 Sep 2009
Weber DM Fricker R Ramseier LE

This is a retrospective study of six children with ununited scaphoid fractures treated conservatively. Their mean age was 12.8 years (9.7 to 16.3). Five had no early treatment. Radiological signs of nonunion were found at a mean of 4.6 months (3 to 7) after injury. Treatment consisted of cast immobilisation until clinical and radiological union. The mean clinical and radiological follow-up was for 67 months (17 to 90). We assessed the symptoms, the range of movement of the wrist and the grip strength to calculate the Modified Mayo Wrist score. The fracture united in all patients after a mean period of immobilisation of 5.3 months (3 to 7). Five patients were pain free; one had mild pain. All returned to regular activities, and had a range of movement and grip strength within 25% of normal, resulting in an excellent Modified Mayo Wrist score. Prolonged treatment with cast immobilisation resulted in union of the fracture and an excellent Modified Wrist Score in all patients


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 311 - 314
1 Feb 2010
Cereatti A Margheritini F Donati M Cappozzo A

The human acetabulofemoral joint is commonly modelled as a pure ball-and-socket joint, but there has been no quantitative assessment of this assumption in the literature. Our aim was to test the limits and validity of this hypothesis. We performed experiments on four adult cadavers. Cortical pins, each equipped with a marker cluster, were implanted in the pelvis and the femur. Movements were recorded using stereophotogrammetry while an operator rotated the cadaver’s acetabulofemoral joint, exploiting the widest possible range of movement. The functional consistency of the acetabulofemoral joint as a pure spherical joint was assessed by comparing the magnitude of the translations of the hip joint centre as obtained on cadavers, with the centre of rotation of two metal segments linked through a perfectly spherical hinge. The results showed that the radii of the spheres containing 95% of the positions of the estimated centres of rotation were separated by less than 1 mm for both the acetabulofemoral joint and the mechanical spherical hinge. Therefore, the acetabulofemoral joint can be modelled as a spherical joint within the considered range of movement (flexion/extension 20° to 70°; abduction/adduction 0° to 45°; internal/external rotation 0° to 30°)


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 521 - 526
1 Apr 2010
Raviraj A Anand A Kodikal G Chandrashekar M Pai S

Delayed rather than early reconstruction of the anterior cruciate ligament is the current recommended treatment for injury to this ligament since it is thought to give a better functional outcome. We randomised 105 consecutive patients with injury associated with chondral lesions no more severe than grades 1 and 2 and/or meniscal tears which only required trimming, to early (< two weeks) or delayed (> four to six weeks) reconstruction of the anterior cruciate ligament using a quadrupled hamstring graft. All operations were performed by a single surgeon and a standard rehabilitation regime was followed in both groups. The outcomes were assessed using the Lysholm score, the Tegner score and measurement of the range of movement. Stability was assessed by clinical tests and measurements taken with the KT-1000 arthrometer, with all testing performed by a blinded uninvolved experienced observer. A total of six patients were lost to follow-up, with 48 patients assigned to the delayed group and 51 to the early group. None was a competitive athlete. The mean interval between injury and the surgery was seven days (2 to 14) in the early group and 32 days (29 to 42) in the delayed group. The mean follow-up was 32 months (26 to 36). The results did not show a statistically significant difference for the Lysholm score (p = 0.86), Tegner activity score (p = 0.913) or the range of movement (p = 1). Similarly, no distinction could be made for stability testing by clinical examination (p = 0.56) and measurements with the KT-1000 arthrometer (p = 0.93). Reconstruction of the anterior cruciate ligament gave a similar clinical and functional outcome whether performed early (< two weeks) or late at four to six weeks after injury


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1253 - 1259
1 Sep 2012
Sewell MD Higgs DS Al-Hadithy N Falworth M Bayley I Lambert SM

Scapulothoracic fusion (STF) for painful winging of the scapula in neuromuscular disorders can provide effective pain relief and functional improvement, but there is little information comparing outcomes between patients with dystrophic and non-dystrophic conditions. We performed a retrospective review of 42 STFs in 34 patients with dystrophic and non-dystrophic conditions using a multifilament trans-scapular, subcostal cable technique supported by a dorsal one-third semi-tubular plate. There were 16 males and 18 females with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0 years (2.0 to 10.6). The mean Oxford shoulder score improved from 20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions had lower overall functional scores but achieved greater improvements following STF. The mean active forward elevation increased from 59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10° to 90°) to 83° (30° to 130°) with a greater range of movement achieved in the dystrophic group. Revision fusion for nonunion was undertaken in five patients at a mean time of 17 months (7 to 31) and two required revision for fracture. There were three pneumothoraces, two rib fractures, three pleural effusions and six nonunions. The main risk factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction in 82% of patients with both dystrophic and non-dystrophic pathologies, but there was a relatively high failure rate (26%) when poor outcomes were analysed. Overall function was better in patients with dystrophic conditions which correlated with better range of movement; however, patients with non-dystrophic conditions achieved greater functional improvement


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 374 - 379
1 Mar 2005
Goldfarb CA Ricci WM Tull F Ray D Borrelli J

Our aim was to correlate the health status with objective and radiological outcomes in patients treated by open reduction and internal fixation for fractures of both bones of the forearm. We assessed 23 patients (24 fractures) subjectively, objectively and radiologically at a mean of 34 months (11 to 72). Subjective assessment used the disability of the arm, shoulder and hand (DASH) and musculoskeletal functional attachment (MFA) questionnaires. The range of movement of the forearm and wrist, grip and pinch strength were measured objectively and standardised radiographs were evaluated. In general, patients reported good overall function based on the DASH (mean 12; range 0 to 42) and MFA (mean 19; range 0 to 51) scores. However, pronation and grip and pinch strength were significantly decreased (p < 0.005). These deficiencies correlated with poorer subjective outcomes. Operative stabilisation of fractures of the radius and ulna led to a reliably acceptable functional outcome. However, despite these generally satisfactory results, the outcome scores worsened with reduction in the range of movement of the forearm and wrist


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 767 - 771
1 Jun 2018
Robinson PM MacInnes SJ Stanley D Ali AA

Aim. The primary aim of this retrospective study was to identify the incidence of heterotopic ossification (HO) following elective and trauma elbow arthroplasty. The secondary aim was to determine clinical outcomes with respect to the formation of heterotopic ossification. Patients and Methods. A total of 55 total elbow arthroplasties (TEAs) (52 patients) performed between June 2007 and December 2015 were eligible for inclusion in the study (29 TEAs for primary elective arthroplasty and 26 TEAs for trauma). At review, 15 patients (17 total elbow arthroplasties) had died from unrelated causes. There were 14 men and 38 women with a mean age of 70 years (42 to 90). The median clinical follow-up was 3.6 years (1.2 to 6) and the median radiological follow-up was 3.1 years (0.5 to 7.5). Results. The overall incidence of HO was 84% (46/55). This was higher in the trauma group (96%, 25/26) compared with the elective arthroplasty group (72%, 21/29) (p = 0.027, Fisher’s exact test). Patients in the trauma group had HO of higher Brooker class. The presence of HO did not significantly affect elbow range of movement within the trauma or elective groups (elective arthroplasty, Mann–Whitney U test, p = 0.070; trauma arthroplasty, p = 0.370, Mann–Whitney U test). Conclusion. HO after total elbow arthroplasty is seen more commonly than previously reported. We have reported a significantly higher rate of HO in TEAs performed for trauma than those performed electively. Cite this article: Bone Joint J 2018;100-B:767–71


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 778 - 781
1 Jun 2007
Sharma S Rymaszewski LA

We present a retrospective study of 25 patients treated by open arthrolysis of the elbow for post-traumatic stiffness. The mean follow-up was for 7.8 years (5 to 10.8). The range of movement of the elbow, pain scores and functional outcomes were recorded pre- and postoperatively. An improvement in the mean range of movement from 55° (0° to 95°) to 105° (55° to 135°) was obtained in our patients at one year. This improvement was maintained over the mean follow-up period of 7.8 years (5 to 10.8). Improvement in pain, function and patient satisfaction was recorded in 23 of the 25 patients at final follow-up. On the basis of this study, we believe that the results of open arthrolysis for post-traumatic stiffness of the elbow are durable over the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 88 - 94
1 Jan 2005
Hasler CC Von Laer L Hell AK

We reviewed 15 patients, nine girls and six boys, with chronic anterior dislocation of the radial head which was treated by ulnar osteotomy, external fixation and open reconstruction of the elbow joint but without repair of the annular ligament. Their mean age was 9.5 years (5 to 15) and the mean interval between the injury and reconstruction was 22 months (2 months to 7 years). All radial heads remained reduced at a mean follow-up of 20 months (6 months to 5 years). Normal ranges of movement for flexion, extension, pronation and supination were unchanged in 96.1% (49/51) and worse in 3.9% (2/51). Limited ranges of movement were improved in 77.8% (7/9), unchanged in 11% (1/9) and further decreased in 11% (1/9).There were two superficial pin-track infections and two cases of delayed union but with no serious complications. Reconstruction of the radiocapitellar joint is easier using external fixation since accurate correction of the ulna can be determined empirically and active functional exercises started immediately. Only patients with a radial head of normal shape were selected for treatment by this method


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 837 - 840
1 Jun 2005
Azzopardi T Ehrendorfer S Coulton T Abela M

We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular fractures of the distal radius to compare the outcome of immobilisation in a cast alone with that using supplementary, percutaneous pinning. Patients treated by percutaneous wires had a statistically significant improvement in dorsal angulation (mean 7°), radial length (mean 3 mm) and radial inclination (mean 3 mm) at one year. However, there was no significant difference in functional outcome in terms of pain, range of movement, grip strength, activities of daily living and the SF-36 score except for an improved range of movement in ulnar deviation in the percutaneous wire group. One patient developed a pin-track infection which required removal of the wires at two weeks. We conclude that percutaneous pinning of unstable, extra-articular fractures of the distal radius provides only a marginal improvement in the radiological parameters compared with immobilisation in a cast alone. This does not correlate with an improved functional outcome in a low-demand, elderly population


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 59 - 65
1 Jan 2019
Katchky AM Jones CW Walter WL Shimmin AJ

Aims. Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes. Patients and Methods. A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry. Results. A total of 100 TKAs in 92 patients were included. Three patients died (three TKAs) and a further two TKAs were revised. Of the remaining 95 TKAs, five-year follow-up data were available for 81 TKAs (85%) in 87 patients. There were significant improvements in all PROMs and high satisfaction. The mean ROM at final follow-up was from 0° (full extension) to 124° flexion. There were seven major complications (7%): one infection, two deep vein thromboses, one cerebrovascular event, and two patients with stiffness requiring a manipulation under anaesthesia. Two patients required a lateral retinacular release to optimize patellar tracking in valgus knees; no additional ligament releases were performed in any patient. Radiological analysis demonstrated no evidence of implant-related complications. Conclusion. These results demonstrate satisfactory clinical and radiological outcomes at five years following a medial ball and socket TKA. The complication and revision rates are consistent with those previously reported for patients undergoing TKA. These results demonstrate the safety and efficacy of the SAIPH Knee TKA system and support its wider use


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 202 - 208
1 Feb 2010
Berton C Girard J Krantz N Migaud H

Implantation of a large-diameter femoral head prosthesis with a metal-on-metal bearing surface reduces the risk of dislocation, increases the range of movement, minimises the risk of impingement and, in theory, results in little wear. Between February 2004 and March 2007 we implanted 100 consecutive total hip replacements with a metal-on-metal bearing and a large femoral head into 92 patients. There were 51 men and 41 women with a mean age of 50 years (18 to 70) at the time of surgery. Outcome was assessed using the Western Ontario McMaster University osteoarthritis index and the Harris hip score as well as the Devane activity score. These all improved significantly (p < 0.0001). At the last follow-up there were no cases of dislocation, no impingement, a good range of movement and no osteolysis, but seven revisions, two for infection and five for aseptic loosening. The probability of groin pain increased if the other acetabular component inclination exceeded 50° (p = 0.0007). At 4.8 years of follow-up, the projected survival of the Durom acetabular component, with revision for any reason, was 92.4% (. sd. 2.8) (95% confidence interval 89.6 to 95.2). The design of the component made it difficult both to orientate and seat, which when combined with a poor porous coating, produced unpredictable fixation and a low survival at five years