We have developed a simple technique for demonstrating the sagittal profile of each rotated level of a scoliotic spine and used it to determine the patterns of lordosis and kyphosis in each of six clinical types of idiopathic scoliosis. The currently accepted classification of scoliosis is inaccurate and a modification is proposed. The three main types of scoliosis were shown to have sagittal profiles distinctly different from each other and from normal. Single structural curves had short lordotic sections at their apices, limited above and below by kyphosis. Double curves showed longer lordotic sections limited only by one area of kyphosis. Lordosis throughout the thoracic and lumbar spine was associated with triple curve patterns. The biomechanical effects of the abnormal sagittal profiles provide a simple explanation for the genesis and progression of the different types of scoliosis, and the recognition of the pattern of the sagittal abnormalities permits treatment to be designed on a sound anatomical basis for individual cases.
The incidence of clinically significant avascular
necrosis (AVN) following medial open reduction of the dislocated
hip in children with developmental dysplasia of the hip (DDH) remains
unknown. We performed a systematic review of the literature to identify
all clinical studies reporting the results of medial open reduction
surgery. A total of 14 papers reporting 734 hips met the inclusion
criteria. The mean follow-up was 10.9 years (2 to 28). The rate
of clinically significant AVN (types 2 to 4) was 20% (149/734).
From these papers 221 hips in 174 children had sufficient information
to permit more detailed analysis. The rate of AVN increased with
the length of follow-up to 24% at skeletal maturity, with type 2
AVN predominating in hips after five years’ follow-up. The presence
of AVN resulted in a higher incidence of an unsatisfactory outcome
at skeletal maturity (55% Cite this article:
In 1988 we reported a ten-year review of 83 surviving patients from a group of 135 (146 prostheses) who had undergone primary hip replacement using the Stanmore prosthesis. We have now reviewed 44 of these patients at 15 to 16 years. Four patients had undergone revision, but the other 40 were all satisfied with the result of their hip replacement, 36 having little or no pain. Functional activities had decreased, but were still adequate for their average age of 81 years. There had been definite migration of the cup and/or femoral component in three hips, wear of the cup in ten and resorption of the calcar in six. Of the 24 hips inserted with radiopaque cement, eight showed an increase in radiolucent lines at the acetabular interface. The cumulative survival rate of the prosthesis was 91% at 15 to 16 years.
A new radiological technique is presented in which serial axial radiographs of the patellofemoral joints are taken under conditions in which the muscles about the knee and hip are contracted in a manner similar to that during weight-bearing. A form of analysis has been developed whereby patellar rotation can be measured in two planes and femoral rotation about its long axis inferred. A population of asymptomatic adults and children was investigated in this way and their results (regarded as normal) compared with those in fifteen children with idiopathic chondromalacia patellae. In the normal child the femur rotates medially with the onset of muscle activity; by contrast the children with chondromalacia show a reversal of this mechanism.
Thirty-seven patients with extensive acetabular defects due to loose implants had revisions with uncemented components, the acetabulum being augmented with homograft bone. In six of these, a histological study of graft incorporation was made. At a mean follow-up of 1.5 years 34 patients were free of pain and 35 could walk for 30 minutes or longer. No graft had obviously sequestrated. Two components had radiological evidence of migration but remain asymptomatic. We conclude that cementless revision surgery with homograft supplementation of the acetabulum is clinically successful in the short-term. The long-term outcome is unknown.
We aimed to find out whether the Hastings bipolar prosthesis moved in a bipolar fashion after its use for displaced fractures of the femoral neck. In 65 patients non-weight-bearing movement was assessed radiographically and compared with an earlier study of the Monk prosthesis. In 70% of patients, the only movement was between the acetabulum and the prosthetic shell, the prosthesis behaving as if it were unipolar. This did not change with time, but there was a slight improvement in the range of movement, particularly in flexion. The absence of movement between the outer shell and the metal head is most probably due to the design of the prosthesis and makes this prosthesis unsuitable for use in osteoarthritic hips.
The early diagnosis of caisson disease of bone is hindered by the long delay which must elapse before an abnormality becomes apparent on a radiograph. The possible use of bone scintigraphy for this purpose was investigated. Necrosis of the bone and marrow was produced in rabbits by glass microspheres to simulate persistent gas-bubble emboli and then serial radiographs and scintigrams using 99mTc-diphosphonate were obtained. Regions of necrosis could be detected as "hot-spots" on the scintigrams as early as three weeks after the causative insult, which was many weeks before any abnormality could be detected on the radiographs. Histological examination of excised femora suggested that the scintigraphic abnormality might depend on the new bone formation during a reactive or repair process. It is suggested that scintigraphy may have clinical value in caisson disease.
In 44 consecutive patients, 60 porous-coated anatomic total knee (PCA) prostheses with a porous-coated central tibial stem were implanted without using cement. The clinical results and bony remodelling have been assessed after five years' follow-up. The average Hospital for Special Surgery knee score was 33.1 before operation and 95.7 at the latest follow-up, while the average range of movement improved from 63 degrees to 123 degrees. No subsidence or migration of the components was seen. A radiodense line appeared around the components at six months to one year after the operation and became more dense with time. There was no evidence of bone resorption related to stress-shielding in the tibial plateau.
Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to
The April 2024 Children’s orthopaedics Roundup. 360. looks at: Ultrasonography or
The October 2023 Spine Roundup. 360. looks at: Cutting through surgical smoke: the science of cleaner air in spinal operations; Unlocking success: key factors in thoracic spine decompression and fusion for ossification of the posterior longitudinal ligament; Deep learning algorithm for identifying cervical cord compression due to degenerative canal stenosis on
The February 2024 Research Roundup. 360. looks at: If you use a surgical helmet, you should seal your gown-glove interface; The use of iodophor-impregnated drapes in patients with iodine-related allergies: a case series and review of the literature; Location of the ovaries in children and efficacy of gonadal shielding in hip and pelvis
Aims. Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial
Aims. Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. Methods. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution.