It is not clear whether anterior knee pain and osteoarthritis
(OA) of the patellofemoral joint (PFJ) are contraindications to
medial unicompartmental knee arthroplasty (UKA). Our aim was to
investigate the long-term outcome of a consecutive series of patients,
some of whom had anterior knee pain and PFJ OA managed with UKA. We assessed the ten-year functional outcomes and 15-year implant
survival of 805 knees (677 patients) following medial mobile-bearing
UKA. The intra-operative status of the PFJ was documented and, with
the exception of bone loss with grooving to the lateral side, neither
the clinical or radiological state of the PFJ nor the presence of
anterior knee pain were considered a contraindication. The impact
of radiographic findings and anterior knee pain was studied in a
subgroup of 100 knees (91 patients).Aims
Patients and Methods
Patient-reported outcome measures (PROMs) are
increasingly being used to assess functional outcome and patient satisfaction.
They provide a framework for comparisons between surgical units,
and individual surgeons for benchmarking and financial remuneration.
Better performance may bring the reward of more customers as patients and
commissioners seek out high performers for their elective procedures.
Using National Joint Registry (NJR) data linked to PROMs we identified
22 691 primary total knee replacements (TKRs) undertaken for osteoarthritis
in England and Wales between August 2008 and February 2011, and
identified the surgical factors that influenced the improvements
in the Oxford knee score (OKS) and EuroQol-5D (EQ-5D) assessment
using multiple regression analysis. After correction for patient
factors the only surgical factors that influenced PROMs were implant
brand and hospital type (both p <
0.001). However, the effects
of surgical factors upon the PROMs were modest compared with patient
factors. For both the OKS and the EQ-5D the most important factors
influencing the improvement in PROMs were the corresponding pre-operative
score and the patient’s general health status. Despite having only
a small effect on PROMs, this study has shown that both implant
brand and hospital type do influence reported subjective functional
scores following TKR. In the current climate of financial austerity,
proposed performance-based remuneration and wider patient choice,
it would seem unwise to ignore these effects and the influence of
a range of additional patient factors.
Oxidised zirconium was introduced as a material for femoral components
in total knee arthroplasty (TKA) as an attempt to reduce polyethylene
wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected
database to assess the ten year survival and clinical and radiological
outcomes of an oxidised zirconium total knee arthroplasty with the
Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis
Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS)
and a patient satisfaction scale were used to assess outcome.Aims
Methods
Total knee arthroplasty (TKA) is a cost effective
and extremely successful operation. As longevity increases, the demand
for primary TKA will continue to rise. The success and survivorship
of TKAs are dependent on the demographics of the patient, surgical
technique and implant-related factors. Currently the risk of failure of a TKA requiring revision surgery
ten years post-operatively is 5%. The most common indications for revision include aseptic loosening
(29.8%), infection (14.8%), and pain (9.5%). Revision surgery poses
considerable clinical burdens on patients and financial burdens
on healthcare systems. We present a current concepts review on the epidemiology of failed
TKAs using data from worldwide National Joint Registries. Cite this article:
Multimodal infiltration of local anaesthetic provides effective
control of pain in patients undergoing total knee arthroplasty (TKA).
There is little information about the added benefits of posterior
capsular infiltration (PCI) using different combinations of local
anaesthetic agents. Our aim was to investigate the effectiveness
of the control of pain using multimodal infiltration with and without
infiltration of the posterior capsule of the knee. In a double-blind, randomised controlled trial of patients scheduled
for unilateral primary TKA, 86 were assigned to be treated with
multimodal infiltration with (Group I) or without (Group II) PCI.
Routine associated analgesia included the use of bupivacaine, morphine,
ketorolac and epinephrine. All patients had spinal anaesthesia and patient-controlled
analgesia (PCA) post-operatively. A visual analogue scale (VAS)
for pain and the use of morphine were recorded 24 hours post-operatively.
Side effects of the infiltration, blood loss, and length of stay
in hospital were recorded.Aims
Patients and Methods
This is the second of a series of reviews of registries. This review looks specifically at worldwide registry data that have been collected on knee arthroplasty, what we have learned from their reports, and what the limitations are as to what we currently know.
Although patients with a history of venous thromboembolism
(VTE) who undergo lower limb joint replacement are thought to be
at high risk of further VTE, the actual rate of recurrence has not
been reported. The purpose of this study was to identify the recurrence rate
of VTE in patients who had undergone lower limb joint replacement,
and to compare it with that of patients who had undergone a joint
replacement without a history of VTE. From a pool of 6646 arthroplasty procedures (3344 TKR, 2907 THR,
243 revision THR, 152 revision TKR) in 5967 patients (68% female,
mean age 67.7; 21 to 96) carried out between 2009 and 2011, we retrospectively
identified 118 consecutive treatment episodes in 106 patients (65%
female, mean age 70; 51 to 88,) who had suffered a previous VTE.
Despite mechanical prophylaxis and anticoagulation with warfarin,
we had four recurrences by three months (3.4% of 118) and six by
one year (5.1% of 118). In comparison, in all our other joint replacements
the rate of VTE was 0.54% (35/6528). The relative risk of a VTE by 90 days in patients who had undergone
a joint replacement with a history of VTE compared with those with
a joint replacement and no history of VTE was 6.3 (95% confidence
interval, 2.3 to 17.5). There were five complications in the previous
VTE group related to bleeding or over-anticoagulation. Cite this article:
We evaluated the survival of moulded monoblock and modular tibial components of the AGC total knee replacement in patients with rheumatoid arthritis. Between 1985 and 1995, 751 knees with this diagnosis were replaced at our institution. A total of 256 tibial components were of the moulded design and 495 of the modular design. The mean follow-up of the moulded subgroup was 9.6 years (0.5 to 14.7), and that of the modular group 7.0 years (0.1 to 14.7). The groups differed significantly from each other in Larsen grade, cementing of components and patellar resurfacing, but no statistically significant difference between the survival of the components was found (Log rank test, p = 0.91). The cumulative success rate of the moulded group was 96.8% (95% confidence interval 93.6% to 98.4%) at five years and 94.4% (95% confidence interval 90.4% to 96.7%) at ten years, and of the modular group 96.2% (95% confidence interval 94% to 97.6%) and 93.6% (95% confidence interval 89.7% to 96%), respectively. Revision was required in 37 total knee replacements, the main causes were infection, pain, loosening of the tibial component and patellar problems. Survival rates for both components were satisfactory.
The Advance Medial-Pivot total knee arthroplasty (TKA) was designed
to reflect contemporary data regarding the kinematics of the knee.
We wished to examine the long-term results obtained with this prosthesis
by extending a previous evaluation. We retrospectively evaluated prospectively collected data from
225 consecutive patients (41 men and 184 women; mean age at surgery
71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up
of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both
subjective and objective) and radiological outcome were assessed.
Pre- and post-operative clinical and radiographic data were available
at regular intervals for all patients. A total of ten patients (4.4%;
ten TKAs) were lost to follow-up.Aims
Patients and Methods
Evaluation of patients with painful total knee replacement requires a thorough clinical examination and relevant investigations in order to reach a diagnosis. Awareness of the common and uncommon problems leading to painful total knee replacement is useful in the diagnostic approach. This review article aims to act as a guide to the evaluation of patients with painful total knee replacement.
The management of the patella during total knee replacement is controversial. In some studies the absence of patellar resurfacing results in residual anterior knee pain in over 10% of patients. One form of treatment which may be used in an endeavour to reduce this is circumferential patellar rim electrocautery. This is believed to partially denervate the patella. However, there is no evidence of the efficacy of this procedure, nor do we know if it results in harm. A retrospective comparative cohort study was performed of 192 patients who had undergone a primary total knee replacement with the porous coated Low Contact Stress rotating platform prosthesis without patellar resurfacing between 2003 and 2007. In 98 patients circumferential electrocautery of the patellar rim was performed and in 94 patients it was not. The two groups were matched for gender and age. The general Oxford Knee Score and the more specific patellar score for anterior knee pain were used to assess patient outcomes a minimum of two years post-operatively. No statistically significant differences were noted between the groups for either scoring system (p = 0.41 and p = 0.87, respectively). Electrocautery of the patella rim did not improve the outcome scores after primary total knee replacement in our patients.
The aim of this prospective multicentre study
was to report the patient satisfaction after total knee replacement (TKR),
undertaken with the aid of intra-operative sensors, and to compare
these results with previous studies. A total of 135 patients undergoing
TKR were included in the study. The soft-tissue balance of each
TKR was quantified intra-operatively by the sensor, and 18 (13%)
were found to be unbalanced. A total of 113 patients (96.7%) in
the balanced group and 15 (82.1%) in the unbalanced group were satisfied
or very satisfied one year post-operatively (p = 0.043). A review of the literature identified no previous study with
a mean level of satisfaction that was greater than the reported
level of satisfaction of the balanced TKR group in this study. Ensuring
soft-tissue balance by using intra-operative sensors during TKR
may improve satisfaction. Cite this article:
Locking after total knee replacement is uncommon and is generally caused by the formation of fibrous tissue around the patella. We report an unusual cause of locking resulting from intermittent occlusion of the popliteal artery, which was tethered to cement at the posterior aspect of the tibial component.
This retrospective study evaluated the midterm clinical and radiographic outcomes of a second-generation total knee replacement system. In a multicentre consecutive series of 1512 patients, 1970 knees were treated with the PFC Sigma knee system (Depuy, Warsaw, Indiana). The patients were reviewed for functional outcome, and underwent independent radiographic evaluation at a mean follow-up of 7.3 years (5 to 10). A total of 40 knees (2%) required revision, 17 (0.9%) for infection. The incidence of osteolysis was 2.2%. The ten-year survival with revision for any cause other than infection as the endpoint was 97.2% (95% CI 95.4 to 99.1). The PFC Sigma knee system appears to provide excellent results in the medium term.
This study used CT analysis to determine the rotational alignment of 39 painful and 26 painless fixed-bearing total knee replacements (TKRs) from a cohort of 740 NexGen Legacy posterior-stabilised and cruciate-retaining prostheses implanted between May 1996 and August 2003. The mean rotation of the tibial component was 4.3° of internal rotation (25.4° internal to 13.9° external rotation) in the painful group and 2.2° of external rotation (8.5° internal to 18.2° external rotation) in the painfree group (p = 0.024). In the painful group 17 tibial components were internally rotated more than 9° compared with none in the painfree group (p <
0.001). Additionally, six femoral components in the painful group were internally rotated more than 6° compared with none in the painfree group (p = 0.017). External rotational errors were not found to be associated with pain. Overall, 22 (56.4%) of the painful TKRs had internal rotational errors involving the femoral, the tibial or both components. It is estimated that at least 4.6% of all our TKRs have been implanted with significant internal rotational errors.
Isolated patellofemoral arthritis is a common
condition and there are varying opinions on the most effective treatments.
Non-operative and operative treatments have failed to demonstrate
effective long-term treatment for those in an advanced stage of
the condition. Newer designs and increased technology in patellofemoral replacement
(PFR) have produced more consistent outcomes. This has led to a
renewed enthusiasm for this procedure. Newer PFR prostheses have
addressed the patellar maltracking issues plaguing some of the older designs.
Short-term results with contemporary prostheses and new technology
are described here. Cite this article:
Pain is the main indication for performing total knee replacement (TKR). In most patients after TKR there is an improvement, but a few continue to have pain. Generally, the cause of the pain can be addressed when it is identified. However, unexplained pain can be more difficult to manage because revision surgery is likely to be unrewarding in this group. In our study of 622 cemented TKRs in 512 patients with a mean age of 69 years (23 to 90) treated between January 1995 and August 1998, we identified 24 patients (knees) with unexplained pain at six months. This group was followed for five years (data was unavailable for 18 knees) and ten patients (55.5%) went on to show an improvement without intervention. In the case of unexplained pain, management decisions must be carefully considered, but reassurance can be offered to patients that the pain will improve in more than half with time.
Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p <
0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972). There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.
Stiffness is an uncommon but potentially debilitating complication following total knee replacement (TKR). The treatment of this condition remains difficult and controversial. We present the results of 13 patients who underwent open arthrolysis for stiffness. The mean time between TKR and arthrolysis was 14 months. The mean follow-up was 7.2 years (2 to 10). The mean range of movement prior to arthrolysis was 55°. This increased to 91°, six months after arthrolysis (p <
0.005). The improved range of movement was maintained during the follow-up period. No patient has required revision of their components. We have found arthrolysis to be a useful and successful approach to post-TKR stiffness.
We report the clinical and radiographic outcome of a consecutive series of 138 hydroxyapatite-coated total knee replacements with a mean follow-up of 11 years (10 to 13). The patients were entered into a prospective study and all living patients (76 knees) were evaluated. The Hospital for Special Surgery knee score was obtained for comparison with the pre-operative situation. No patient was lost to follow-up. Radiographic assessment revealed no loosening. Seven prostheses have been revised, giving a cumulative survival rate of 93% at 13 years. We believe this to be the longest follow-up report available for an hydroxyapatite-coated knee replacement and the first for this design of Insall-Burstein II knee.