Immunosuppression following intra-articular injections of steroid into the hip may interfere with asepsis in a subsequent total hip arthroplasty (THA). We have undertaken a retrospective, matched, cohort study of infective complications after THA, in 40 patients who had received such an injection and 40 who had not. In the injection group there were five revisions, four of which were for deep infection. There were none in the matched group. The overall rate of revision in our database of 979 primary THAs was 1.02%. Six additional patients who had received injections underwent investigation for infection because of persistent problems in the hip as compared with one in the control group.
A nationwide study of Perthes’ disease in Norway was undertaken over a five-year period from January 1996. There were 425 patients registered, which represents a mean annual incidence of 9.2 per 100 000 in subjects under 15 years of age, and an occurrence rate of 1:714 for the country as a whole. There were marked regional variations. The lowest incidence was found in the northern region (5.4 per 100 000 per year) and the highest in the central and western regions (10.8 and 11.3 per 100 000 per year, respectively). There was a trend towards a higher incidence in urban (9.5 per 100 000 per year) compared with rural areas (8.9 per 100 000 per year). The mean age at onset was 5.8 years (1.3 to 15.2) and the male:female ratio was 3.3:1. We compared 402 patients with a matched control group of non-affected children (n = 1 025 952) from the Norwegian Medical Birth Registry and analysed maternal data (age at delivery, parity, duration of pregnancy), birth length and weight, birth presentation, head circumference, ponderal index and the presence of congenital anomalies. Children with Perthes’ disease were significantly shorter at birth and had an increased frequency of congenital anomalies. Applying Sartwell’s log-normal model of incubation periods to the distribution of age at onset of Perthes’ disease showed a good fit to the log-normal curve. Our findings point toward a single cause, either genetic or environmental, acting prenatally in the aetiology of Perthes’ disease.
We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported. All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages.
We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases.