Advertisement for orthosearch.org.uk
Results 741 - 760 of 6072
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1699 - 1705
1 Dec 2014
Boyle MJ Gao R Frampton CMA Coleman B

Our aim was to compare the one-year post-operative outcomes following retention or removal of syndesmotic screws in adult patients with a fracture of the ankle that was treated surgically. A total of 51 patients (35 males, 16 females), with a mean age of 33.5 years (16 to 62), undergoing fibular osteosynthesis and syndesmotic screw fixation, were randomly allocated to retention of the syndesmotic screw or removal at three months post-operatively. The two groups were comparable at baseline. . One year post-operatively, there was no significant difference in the mean Olerud–Molander ankle score (82.4 retention vs 86.7 removal, p = 0.367), the mean American Orthopedic Foot and Ankle Society ankle-hindfoot score (88.6 vs 90.1, p = 0.688), the mean American Academy of Orthopedic Surgeons foot and ankle score (96.3 vs 94.0, p = 0.250), the mean visual analogue pain score (1.0 vs 0.7, p = 0.237), the mean active dorsiflexion (10.2° vs 13.0°, p = 0.194) and plantar flexion (33.6° vs 31.3°, p = 0.503) of the ankle, or the mean radiological tibiofibular clear space (5.0 mm vs 5.3 mm, p = 0.276) between the two groups. A total of 19 patients (76%) in the retention group had a loose and/or broken screw one year post-operatively. . We conclude that removal of a syndesmotic screw produces no significant functional, clinical or radiological benefit in adult patients who are treated surgically for a fracture of the ankle. Cite this article: Bone Joint J 2014;96-B:1699–1705


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 974 - 978
1 Sep 2001
Gambirasio R Riand N Stern R Hoffmeyer P

The treatment of multifragmentary, intra-articular fractures of the distal humerus is difficult, even in young patients with bone of good quality, but is worse in elderly patients who have varying degrees of osteopenia. We have evaluated the functional outcome of primary total elbow replacement (TER) in the treatment of these fractures in ten elderly patients followed for a minimum of one year. There were no complications in regard to the soft tissues, bone or prosthesis. The mean range of flexion obtained was 125° (110 to 140) and loss of extension was 23.5° (0 to 50). The mean Mayo score was 94 points (80 to 100) and patient satisfaction was high. We feel that TER provides an alternative to open reduction and internal fixation in the management of these complicated fractures in the elderly


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1545 - 1550
1 Nov 2007
Koslowsky TC Mader K Dargel J Koebke J Hellmich M Pennig D

We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability. A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure. The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N. A significantly better quality of reduction was achieved using the FFS wires (Tukey’s post hoc tests, p < 0.001) than with the other devices with a mean step in the articular surface and the radial neck of 1.04 mm (. sd. 0.96) for the FFS, 4.25 mm (. sd. 1.29) for the miniplates, 2.21 mm (. sd. 1.06) for the miniscrews and 2.54 mm (. sd. 0.98) for the K-wires. The quality of reduction was similar for K-wires and miniscrews, but poor for miniplates. The ultimate failure load was similar for the FFS wires (parallel, 196.8 N (. sd. 46.8), perpendicular, 212.5 N (. sd. 25.6)), miniscrews (parallel, 211.8 N (. sd. 47.9), perpendicular, 208.0 N (. sd. 65.9)) and K-wires (parallel, 200.4 N (. sd. 54.5), perpendicular, 165.2 N (. sd. 37.9)), but significantly worse (Tukey’s post hoc tests, p < 0.001) for the miniplates (parallel, 101.6 N (. sd. 43.1), perpendicular, 122.7 N (. sd. 40.7)). There was a significant difference in the displacement at 50 N for the miniplate (parallel, 4.8 mm (. sd. 2.8), perpendicular, 4.8 mm (. sd. 1.7)) vs FFS (parallel, 2.1 mm (. sd. 0.8), perpendicular, 1.9 mm (. sd. 0.7)), miniscrews (parallel, 1.8 mm (. sd. 0.5), perpendicular, 2.3 mm (. sd. 0.8)) and K-wires (parallel, 2.2 mm (. sd. 1.8), perpendicular, 2.4 mm (. sd. 0.7; Tukey’s post hoc tests, p < 0.001)). The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 89 - 92
1 Jan 1987
Pettine K Morrey B

Sixty-eight patients with 71 osteochondral fractures of the talus were evaluated an average of 7.5 years after the onset of symptoms to determine which factors influenced the final result. It was found that the type of fracture was the most important; delay in treatment also affected the result adversely. A scheme of treatment for each type of fracture is proposed


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 220 - 225
1 Mar 1996
Abernethy PJ Robinson CM Fowler RM

We reviewed 1567 elective knee replacements performed between 1980 and 1990, using either the Total Condylar prosthesis with an all-plastic tibial component, or the Kinematic prosthesis which has a metal tibial tray. The ten-year probability of survival was 92.1% for the Total Condylar design and 87.9% for the Kinematic. The difference was mainly due to 16 revisions required in the Kinematic series for fracture of the metal base-plate. This was the most common cause of aseptic failure in this group. These fractures were strongly associated with a preoperative varus deformity (hazard ratio (HR) 8.8) and there was a slightly increased risk in males (HR 1.9) and in osteoarthritic knees (HR 1.8). In the nine fractures which occurred within four years of primary implantation (group 1), failure to correct adequately a preoperative varus deformity and the use of a bone graft to correct such a deformity were both strongly associated with fracture (HR 13.9 and 15.8, respectively). In eight fractures which occurred more than five years after primary replacement (group 2) we could detect no significant risk factors. Early complications occurred in two patients after the 16 revision procedures for tray fracture. One had a deep infection and the other refracture of the tray


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1478 - 1481
1 Nov 2009
Lee YH Kim JY Chung MS Baek GH Gong HS Lee SK

We treated 32 displaced mallet finger fractures by a two extension block Kirschner-wire technique. The clinical and radiological outcomes were evaluated at a mean follow-up of 49 months (25 to 84). The mean joint surface involvement was 38.4% (33% to 50%) and 18 patients (56%) had accompanying joint subluxation. All 32 fractures united with a mean time to union of 6.2 weeks (5.1 to 8.2). Congruent joint surfaces and anatomical reduction were seen in all cases. The mean flexion of the distal interphalangeal joints was 83.1° (75° to 90°) and the mean extension loss was 0.9° (0° to 7°). No digit had a prominent dorsal bump or a recurrent mallet deformity. We believe that this technique, when properly applied, produces satisfactory results both clinically and radiologically


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 236 - 239
1 Feb 2007
van Geenen RCI Besselaar PP

We analysed the operative technique, morbidity and functional outcome of osteotomy and plate fixation for malunited fractures of the forearm sustained in childhood. A total of 20 consecutive patients underwent corrective osteotomy of 21 malunited fractures at a mean age of 12 years (4 to 25). The mean time between the injury and the osteotomy was 30 months (2 to 140). After removal of the plate, one patient suffered transient dysaesthesia of the superficial radial nerve. The mean gain in the range of movement was 85° (20° to 140°). The interval between injury and osteotomy, and the age at osteotomy significantly influenced the functional outcome (p = 0.011 and p = 0.004, respectively). Malunited fractures of the forearm sustained in childhood can be adequately treated by osteotomy and plate fixation with excellent functional results and minimal complications. In the case of established malunion it is advisable to perform corrective osteotomy without delay


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 726 - 731
1 Sep 1996
Kreder HJ Hanel DP McKee M Jupiter J McGillivary G Swiontkowski MF

We sought to quantify agreement by different assessors of the AO classification for distal fractures of the radius. Thirty radiographs of acute distal radial fractures were evaluated by 36 assessors of varying clinical experience. Our findings suggest that AO ‘type’ and the presence or absence of articular displacement are measured with high consistency when classification of distal radial fractures is undertaken by experienced observers. Assessors at all experience levels had difficulty agreeing on AO ‘group’ and especially AO ‘subgroup’. To categorise distal radial fractures according to joint displacement and AO type is simple and reproducible. Our study examined only whether distal radial fractures could be consistently classified according to the AO system. Validation of the classification as a predictor of outcome will require a prospective clinical study


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 481 - 484
1 May 1999
Robinson CM O’Donnell J Will E Keating JF

We made a prospective study of 208 patients with tibial fractures treated by reamed intramedullary nailing. Of these, 11 (5.3%) developed dysfunction of the peroneal nerve with no evidence of a compartment syndrome. The patients with this complication were significantly younger (mean age 25.6 years) and most had closed fractures of the forced-varus type with relatively minor soft-tissue damage. The fibula was intact in three, fractured in the distal or middle third in seven, with only one fracture in the proximal third. Eight of the 11 patients showed a ‘dropped hallux’ syndrome, with weakness of extensor hallucis longus and numbness in the first web space, but no clinical involvement of extensor digitorum longus or tibialis anterior. This was confirmed by nerve-conduction studies in three of the eight patients. There was good recovery of muscle function within three to four months in all cases, but after one year three patients still had some residual tightness of extensor hallucis longus, and two some numbness in the first web space. No patient required further treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 23 - 25
1 Jan 1990
Sojbjerg J Eiskjaer S Moller-Larsen F

Forty comminuted or unstable fractures of the femoral shaft were treated by closed intramedullary reaming and locked nailing. Twenty-four fractures were severely comminuted, and the other 16, in the distal or proximal third of the shaft, were classified as unstable. At 12 to 30 months postoperatively all the fractures had healed. Three patients had lateral rotation deformity of 5 degrees to 10 degrees, three had shortening of 1 to 2 cm and two had lengthening of about 1 cm. There were no infections or delayed unions. Closed intramedullary locked nailing can provide stability in fractures of the femoral shaft, irrespective of the degree of comminution and the site of injury


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 545 - 551
1 Apr 2009
Schnurr C Nessler J Meyer C Schild HH Koebke J König DP

The aim of our study was to investigate whether placing of the femoral component of a hip resurfacing in valgus protected against spontaneous fracture of the femoral neck. We performed a hip resurfacing in 20 pairs of embalmed femora. The femoral component was implanted at the natural neck-shaft angle in the left femur and with a 10° valgus angle on the right. The bone mineral density of each femur was measured and CT was performed. Each femur was evaluated in a materials testing machine using increasing cyclical loads. In specimens with good bone quality, the 10° valgus placement of the femoral component had a protective effect against fractures of the femoral neck. An adverse effect was detected in osteoporotic specimens. When resurfacing the hip a valgus position of the femoral component should be achieved in order to prevent fracture of the femoral neck. Patient selection remains absolutely imperative. In borderline cases, measurement of bone mineral density may be indicated


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 264 - 270
1 Feb 2009
Hasegawa T Miwa M Sakai Y Niikura T Kurosaka M Komori T

The haematoma occurring at the site of a fracture is known to play an important role in bone healing. We have recently shown the presence of progenitor cells in human fracture haematoma and demonstrated that they have the capacity for multilineage mesenchymal differentiation. There have been many studies which have shown that low-intensity pulsed ultrasound (LIPUS) stimulates the differentiation of a variety of cells, but none has investigated the effects of LIPUS on cells derived from human fracture tissue including human fracture haematoma-derived progenitor cells (HCs). In this in vitro study, we investigated the effects of LIPUS on the osteogenic activity of HCs. Alkaline phosphatase activity, osteocalcin secretion, the expression of osteoblast-related genes and the mineralisation of HCs were shown to be significantly higher when LIPUS had been applied but without a change in the proliferation of the HCs. These findings provide evidence in favour of the use of LIPUS in the treatment of fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 380 - 381
1 Mar 2006
Sibinski M Sharma H Bennet GC

We examined differences in the rate of open reduction, operating time, length of hospital stay and outcome between two groups of children with displaced supracondylar fractures of the humerus who underwent surgery either within 12 hours of the injury or later. There were 77 children with type-3 supracondylar fractures. Of these, in 43 the fracture was reduced and pinned within 12 hours and in 34 more than 12 hours after injury. Both groups were similar in regard to gender, age and length of follow-up. Bivariate and logistical regression analysis showed no statistical difference between the groups. The number of peri-operative complications was low and did not affect the outcome regardless of the timing of treatment. Our study confirmed that the treatment of uncomplicated displaced supracondylar fractures of the humerus can be early or delayed. In these circumstances operations at night can be avoided


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 173 - 177
1 Mar 1989
Rehnberg L Olerud C

We measured the stability of fixation in femoral neck fractures treated with von Bahr screws, investigated the influence of impaction and correlated peroperative stability with the clinical results. Stability was measured at operation using a metal probe fitted with strain gauges. Its tip was anchored in the subchondral bone of the femoral head and its lateral end was fixed in the lateral femoral cortex. The shearing force produced by longitudinal compression applied to the foot of the operated leg was recorded. The results in 41 consecutive patients all followed for 30 months, showed that fractures with early loosening or nonunion had all had significantly poorer stability than the fractures that had healed. Impaction improved stability in only 23 out of the 41 fractures; in the others stability had deteriorated or was unchanged


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 689 - 694
1 May 2011
Garrett BR Hoffman EB Carrara H

Distal femoral physeal fractures in children have a high incidence of physeal arrest, occurring in a mean of 40% of cases. The underlying nature of the distal femoral physis may be the primary cause, but other factors have been postulated to contribute to the formation of a physeal bar. The purpose of this study was to assess the significance of contributing factors to physeal bar formation, in particular the use of percutaneous pins across the physis. We reviewed 55 patients with a median age of ten years (3 to 13), who had sustained displaced distal femoral physeal fractures. Most (40 of 55) were treated with percutaneous pinning after reduction, four were treated with screws and 11 with plaster. A total of 40 patients were assessed clinically and radiologically after skeletal maturity or at the time of formation of a bar. The remaining 15 were followed up for a minimum of two years. Formation of a physeal bar occurred in 12 (21.8%) patients, with the rate rising to 30.6% in patients with high-energy injuries compared with 5.3% in those with low-energy injuries. There was a significant trend for physeal arrest according to increasing severity using the Salter-Harris classification. Percutaneous smooth pins across the physis were not statistically associated with growth arrest


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 307 - 310
1 Mar 1989
Dias J Brenkel I Finlay D

Eighty-two of 85 patients who had sustained a fracture of the waist of the scaphoid in 1985 were reviewed more than one year after injury. The incidence of nonunion, defined as a clear gap at the fracture site one year after injury, was 12.3%. This was much higher than expected. Most of the patients with nonunion had symptoms and had appreciable restriction of wrist movement. In a further 25% of the patients at review, the site of the fracture could be easily identified although it appeared to have healed. These patients were older and more of them were women. Three-quarters of these patients had symptoms but their wrist movement was essentially normal


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 391 - 395
1 May 1984
Panting A Lamb D Noble J Haw C

A review of 61 patients with dislocation of the lunate (some with and some without fracture of the scaphoid) showed that the majority had satisfactory results at an average follow-up of three and a half years. Most patients with a simple dislocation had a good or satisfactory result; radiological instability was noted in a quarter of the wrists but was not often associated with symptoms. Two-thirds of the patients with an associated fracture of the scaphoid had a good or satisfactory result. Immediate percutaneous wire fixation of the reduced scaphoid, whether it is fractured or not, is the best way of maintaining normal anatomical relationship while the ligaments and fracture heal; this may further improve the prognosis. In most cases extreme dorsiflexion of the wrist appeared to be the mechanism of injury


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 468 - 474
1 Apr 2018
Kirzner N Zotov P Goldbloom D Curry H Bedi H

Aims

The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations.

Patients and Methods

A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 734 - 737
1 Sep 1997
Guichet J Moller C Dautel G Lascombes P

Anteriorly displaced fractures of the wrist can be treated by the Kapandji technique of percutaneous intrafocal pinning with pins inserted through an anterior approach to give good reduction and stabilisation of the fracture. We have modified this technique by placing the pins through a posterior approach which decreases the risks of neurovascular damage. We have used this method to treat six children with distal radial fractures showing anterior displacement or instability. Good anterior stabilisation was achieved. The pins were removed at an average of eight weeks and the patients were then able to return to full activity. This simple technique can be used for unstable fractures after the failure of conservative treatment or in bilateral fractures in adolescents