Advertisement for orthosearch.org.uk
Results 721 - 740 of 1298
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1124 - 1132
1 Nov 2004
Tsiridis E Narvani AA Haddad FS Timperley JA Gie GA

We reviewed retrospectively the outcome of the treatment by impaction grafting of periprosthetic femoral fractures around loose stems in 106 patients with Vancouver type-B2 and type-B3 fractures. Eighty-nine patients had a cemented revision with impaction grafting and a long or short stem. The remaining 17 had cemented revision without impaction grafting. Fractures treated by impaction grafting and a long stem were more than five times likely to unite than those treated by impaction grafting and a short stem (odds ratio = 5.5, 95% confidence interval (CI) 1.54 to 19.6; p = 0.009). Furthermore, those with impaction grafting and a long stem were significantly more likely to unite than those with a long stem without impaction grafting (odds ratio = 4.07, 95% CI 1.10 to 15.0; p = 0.035). There was also a trend towards a higher rate of union in those treated by impaction grafting than in those without (odds ratio = 2.69, 95% CI 0.86 to 8.45; p = 0.090). Impaction grafting is being increasingly widely used for the restoration of femoral bone stock. It can be successfully applied to periprosthetic femoral fractures but a long stem should be used to bypass the distal fracture line


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 476 - 484
1 May 1998
Robinson CM

From 1988 to 1994 a consecutive series of 1000 fractures of the adult clavicle was treated in the Orthopaedic Trauma Clinic of the Royal Infirmary of Edinburgh. In males, the annual incidence was highest under 20 years of age, decreasing in each subsequent cohort until the seventh decade. In females, the incidence was more constant, but relatively frequent in teenagers and the elderly. In young patients, fractures usually resulted from road-traffic accidents or sport and most were diaphyseal. Fractures in the outer fifth were produced by simple domestic falls and were more common in the elderly. A new classification was developed based on radiological review of the anatomical site and the extent of displacement, comminution and articular extension. There were satisfactory levels of inter- and intraobserver variation for reliability and reproducibility. Fractures of the medial fifth (type 1), undisplaced diaphyseal fractures (type 2A) and fractures of the outer fifth (type 3A) usually had a benign prognosis. The incidence of complications of union was higher in displaced diaphyseal (type 2B) and displaced outer-fifth (type 3B) fractures. In addition to displacement, the extent of comminution in type-2B fractures was a risk factor for delayed and nonunion


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 47 - 52
1 Jan 1985
Knutson K Lindstrand A Lidgren L

Twenty consecutive patients treated by arthrodesis for failed knee arthroplasty are reviewed. Eight hinged, five stabilised and seven compartmental prostheses were removed, for infection (15 cases), loosening (4) and instability (1). One patient refused a second-stage operation but the remainder gained sound fusion. Infected knees had a two-stage procedure with temporary insertion of gentamicin-loaded beads after removal of the prosthesis; all infections healed. Six arthrodeses using a Hoffmann-Vidal external fixator resulted in two temporary failures. One Ace-Fischer external fixation was successful. Of 10 primary attempts at arthrodesis with an intramedullary Kuntscher nail, nine were successful; the tenth fused after two more attempts by the same method. The two failures of external fixation and two failures after Charnley single-frame compression done elsewhere were successfully fused with intramedullary nails. Delayed union in three cases fused after prolonged fixation and repeated bone grafts. The indications for and methods of arthrodesis after failed knee arthroplasty are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 14 - 23
1 Feb 1968
Lam SJS

1. Sixty-nine patients with degenerative disease of the hip joint were treated by intra-articular arthrodesis using secure internal fixation. External fixation with plaster was not used and the patients were mobilised on crutches after a mean interval of 3·2 weeks. Radiologically evident bony union occurred in 87 per cent of cases. Among the nine patients (13 per cent) who failed to show union only three complained of persistence of severe symptoms. 2. The only significant complication was fracture of the upper femoral shaft in three cases (4·3 per cent). However, this has not occurred since a small plate was used in addition to the nail. 3. The disadvantages of the routine use of plaster fixation are discussed and are contrasted with the advantages of early mobilisation without plaster. 4. Whereas this series does not show a rate of fusion as good as that in the best reported series, it supports the view that arthrodesis of the hip offers the most certain, reliable and efficient means of treatment for severe unilateral degenerative disease of that joint


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 84 - 89
1 Jan 1995
Rommens P Verbruggen J Broos P

We treated 39 patients with fractures of the humeral shaft by closed retrograde locked intramedullary nailing, using Russell-Taylor humeral nails. The mean healing time of all fractures was 13.7 weeks. After consolidation, shoulder function was excellent in 92.3% and elbow function excellent in 87.2%. Functional end-results were excellent in 84.6% of patients, moderate in 10.3% and bad in 5.1%. One patient had a postoperative radial nerve palsy, which recovered within three months. There was additional comminution at the fracture site in three patients (7.7%) which did not affect healing, and slight nail migration in two older patients (5.1%). Two patients (5.1%) needed a second procedure because of disturbed fracture healing. One screw breakage was seen in a patient with delayed union. Retrograde locked humeral nailing appears to be a better solution for the stabilisation of fractures of the humeral shaft than anterograde nailing or plate and screw fixation. We found the complication rate to be acceptable and shoulder and elbow function to recover rapidly in most cases


Bone & Joint Research
Vol. 7, Issue 2 | Pages 179 - 186
1 Feb 2018
Wu T Zhang J Wang B Sun Y Liu Y Li G

Objectives

As one of the heat-stable enterotoxins, Staphylococcal enterotoxin C2 (SEC2) is synthesized by Staphylococcus aureus, which has been proved to inhibit the growth of tumour cells, and is used as an antitumour agent in cancer immunotherapy. Although SEC2 has been reported to promote osteogenic differentiation of human mesenchymal stem cells (MSCs), the in vivo function of SCE2 in animal model remains elusive. The aim of this study was to further elucidate the in vivo effect of SCE2 on fracture healing.

Materials and Methods

Rat MSCs were used to test the effects of SEC2 on their proliferation and osteogenic differentiation potentials. A rat femoral fracture model was used to examine the effect of local administration of SEC2 on fracture healing using radiographic analyses, micro-CT analyses, biomechanical testing, and histological analyses.


Bone & Joint 360
Vol. 7, Issue 3 | Pages 27 - 29
1 Jun 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 760 - 766
1 Nov 1986
Rastogi S Wild B Duthie R

A medical and engineering study was made of 1074 car accidents involving 2520 vehicle occupants. The injuries they sustained were correlated with details of the crash and with contact points inside the cars. Where possible the forces which were generated in the crash were estimated and related to the injuries. In all, 39 car occupants suffered femoral shaft fracture, with an incidence of 1.7% and 0.8% for front and rear seat occupants respectively. Of these, 31 had associated injuries to other regions of the body; these were the cause of 13 of the 14 deaths in this group. Associated injuries were more severe in car occupants who were not wearing seat belts but the incidence of femoral fracture was not significantly different. The mean velocity change (delta-V) causing femoral fracture was 26 mph (42 km/h) and there was a higher incidence of femoral shaft fracture when delta-V was over 30 mph. Estimates of forces needed to cause fracture were higher than those found in cadaver studies. The time to union of femoral fractures did not correlate with the severity of the crash but was longer (mean 19 weeks) than the average for other femoral fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 228 - 232
1 Apr 1982
Pearcy M Burrough S

Assessment of bony union after anterior fusion of the lumbar spine has previously relied on the skilled interpretation of plain radiograph. A biplanar radiographic technique was used to measure small movements between vertebrae and to give a quantitative measure of bony union in 11 patients who had undergone interbody fusion with autogenous bone chips at one level in the lumbar spine. The investigation gave three types of results: bony union, where the fused level showed marked restriction of movement relative to the rest of the lumbar spine; paradoxical movement, where the fused joint showed marked reverse movement (when the patient flexed, the fused level of the lumbar spine extended) which was thought to be due to an anterior bony bar which caused an altered pattern of movement; and non-union, where the level of fusion showed no restriction of movement. The intervertebral joint above the level of fusion was shown to move more than the other joints in the lumbar spine. The study showed that bony union is possible with the use of autogenous cancellous bone chips, and that biplanar radiographic technique can determine the extent of union


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 11 - 20
1 Feb 1960
Eyre-Brook AL

A series of ten infants is reported, seven of whom showed evidence of osteomyelitis of the upper end of the femur; the remaining three did not, but presented with an acute subluxation of the hip in a febrile illness. Four sequelae among the seven more severe cases were: 1) destruction of the capital epiphysis with dislocation at the hip; 2) destruction of the capital epiphysis, the femoral neck remaining in the acetabulum; 3) destruction of the epiphysial plate with the femoral head, remaining in the acetabulum, connected to the femoral neck by a fibrous union; 4) recovery with coxa magna but no other deformity. The streptococcus plays a greater part in this osteomyelitis of infancy than in osteomyelitis of older children, but various other organisms were identified. The organism should be sought by blood culture as well as from the local lesion. Aspiration of the hip, treatment of the hip in abduction and the use of the appropriate antibiotic are recommended. If there is marked swelling and induration, freer release of the pus is strongly advised. Controlled abduction osteotomy plays a useful part in stabilising the femoral neck in the acetabulum or in stabilising the femoral neck beneath the capital epiphysis, but may usefully be preceded by an arthrograph because late ossification of a detached head sometimes occurs


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 43 - 47
1 Jan 1997
Minami A Kaneda K Satoh S Abumi K Kutsumi K

A vascularised fibular strut graft was used for anterior spinal fusion in 16 patients with spinal kyphosis. The procedure was abandoned in three because of difficulty in establishing a vascular anastomosis and in one because the grafted fibula dislodged two days after operation. One patient died after five days. Of the 11 remaining patients, there were seven males and four females. Their ages at the time of operation averaged 30.9 years (12 to 71). The number of vertebrae fused averaged 6.7 (5 to 9) and the length of fibula grafted averaged 10.9 cm (6.5 to 18). Average follow-up was 54 months (27 to 84). Bone union occurred at both ends of the grafted fibula in all 11 patients, with an average time to union of 5.5 months (3 to 8). We did not see a fracture of the grafted fibula. Two patients had postoperative complications; the graft dislodged in one and laryngeal oedema occurred two days after operation in the other. A vascularised fibular strut graft provides a biomechanically stable and long-standing support in spinal fusion because the weak phase of creeping substitution does not take place in the graft


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 510 - 516
1 May 2003
Langlais F Lambotte JC Collin P Langlois F Fontaine JW Thomazeau H

We used a trochanteric slide osteotomy (TSO) in 94 consecutive revision total hip arthroplasties (90 with replacement of both the cup and stem). This technique proved to be adequate for removing the components, with few complications (two minor fractures), and for implanting acetabular allografts (18%) and reinforcement devices (23%). Trochanteric union was obtained in most patients (96%), even in those with septic loosening (18/19), major femoral osteolysis (32/32), or previous trochanteric osteotomy (17/18). TSO is versatile, since it can be extended by a femoral flap (four cases) or a distal femoral window (eight cases). Despite significant bone loss, in 24% of the femora and 57% of the acetabula, favourable midterm results were achieved and only six reoperations were required, including two for trochanteric nonunion and two for loosening. It leaves the lateral femoral cortex intact so that a stem longer than 200 mm was needed in only 25% of patients. This is a considerable advantage compared with the extended trochanteric osteotomy in which the long lateral flap (12 to 14 cm) requires an average length of stem of 220 mm beyond the calcar. TSO provides an approach similar in size to the standard trochanteric osteotomy but with a rate of nonunion of 4% versus 15%. It reduces the risk of difficulties with removal of the stem, and removes the need for routine distal anchoring of long revision stems. The limited distal femoral compromise is very important in patients with a long life expectancy


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 719 - 724
1 Jul 1999
Louisia S Stromboni M Meunier A Sedel L Petite H

Limited success in regenerating large bone defects has been achieved by bridging them with osteoconductive materials. These substitutes lack the osteogenic and osteoinductive properties of bone autograft. A direct approach would be to stimulate osteogenesis in these biomaterials by the addition of fresh bone-marrow cells (BMC). We therefore created osteoperiosteal gaps 2 cm wide in the ulna of adult rabbits and either bridged them with coral alone (CC), coral supplemented with BMC, or left them empty. Coral was chosen as a scaffold because of its good biocompatibility and resorbability. In osteoperiosteal gaps bridged with coral only, the coral was invaded chiefly by fibrous tissue. It was insufficient to produce union after two months. In defects filled with coral and BMC an increase in osteogenesis was observed and the bone surface area was significantly higher compared with defects filled with coral alone. Bony union occurred in six out of six defects filled with coral and BMC after two months. An increase in the resorption of coral was also observed, suggesting that resorbing cells or their progenitors were present in bone marrow and survived the grafting procedure. Our findings have shown that supplementation of coral with BMC increased both the resorption of material and osteogenesis in defects of a clinical significance


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 21 - 30
1 Jan 2003
Mears DC Velyvis J Resident

We have retrospectively reviewed the clinical and radiological results in 204 consecutive adult patients who had surgical correction of 70 late post-traumatic pelvic nonunions and 134 malalignments. The deformed pelvises were subdivided into united (true), unstable, ununited, and partially stable malalignments with heterotopic bone. The principal complaints were of pain, pelvic instability, sitting imbalance, and apparent limb-length discrepancy. After surgery, 195 patients (96%) achieved a primary union and 144 (71%) had slight, intermittent or no pelvic pain, while pelvic instability was entirely eliminated. Overall, 131 patients (64.2%) were extremely satisfied, 58 (28.4%) were satisfied and 15 (7.4%) were unsatisfied. After reconstruction of the malaligned pelvises, 67 results (50%) were anatomical, 47 (35%) were satisfactory and 20 (15%) were unsatisfactory. For a pelvic nonunion with local osteopenia and malalignment, stabilisation of all three pelvic columns is recommended. True pelvic (united) malunions were the most satisfactorily realigned and had the fewest complications. Ununited and unstable malalignments, especially those with heterotopic bone, had the poorest corrections and the most neurological complications. A therapeutic alternative, by the local resection of a symptomatic bony prominence, and fixation in situ of a posterior pelvic nonunion, gives highly effective symptomatic relief with fewer complications. Despite this, many patients had persistent low back pain


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 352 - 354
1 May 1987
Bernard A Brooks S

Fifty-nine cases of trochanteric wire revision following hip arthroplasty with trochanteric osteotomy and reattachment were identified and their outcome was studied. Two were infected and were excluded. Five were revised for instability: four became stable while one continued to have persistent dislocation. Fifty-two were revised for pain, 36 by removal of the trochanteric wire and 16 by reattachment of the greater trochanter. Successful relief of pain was obtained in less than half the cases. There was no difference in the incidence of back pain, wiring technique, trochanteric advancement, previous surgery to the same hip, trochanteric size or the pattern of wire breakage in the successfully treated group and the unsuccessful group. Neither was the removal of intact wire from a united trochanter any more certain of relieving pain than removal of broken wire from an un-united trochanter. Six patients later required revision for loosening or infection. These results indicate the need for full radiological and haematological investigation before exploration of the greater trochanter. At exploration for pain the wires should simply be removed as we could show no successful union after late reattachment of the trochanter in the absence of instability


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 134 - 138
1 Jan 1998
Dahm DL Kitaoka HB

We studied retrospectively the results in 24 patients (25 feet) who had been treated by subtalar arthrodesis with internal compression for post-traumatic arthritis from 1988 to 1992. Fifteen patients were men (16 feet) and nine (9 feet) were women. Their mean age was 43 years (22 to 68), and the average duration of follow-up was four years (2 to 6). A single compression screw was used in all feet and iliac-crest bone grafting in ten. Union was achieved in 24 of the 25 feet (96%). Based on a clinical scale the results were excellent in 10 feet, good in 7, fair in 6, and poor in 2 and on the Angus and Cowell score they were good in 19 feet, fair in 4, and poor in 2. The two poor results were due to nonunion in one patient and reflex sympathetic dystrophy in the other. One reoperation was performed for nonunion. Eighteen patients (18 feet) were satisfied with the results, four were satisfied with reservations, and three were dissatisfied. Progressive ankle and midfoot arthritis did not occur in the absence of pre-existing degenerative changes in these joints. We conclude that isolated subtalar arthrodesis with internal compression was effective treatment for post-traumatic subtalar arthritis. Iliac-crest bone grafting was not routinely required


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 624 - 633
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML

Aim

The aim of this study was to compare the cost-effectiveness of intramedullary nail fixation and ‘locking’ plate fixation in the treatment of extra-articular fractures of the distal tibia.

Patients and Methods

An economic evaluation was conducted from the perspective of the United Kingdom National Health Service (NHS) and personal social services (PSS), based on evidence from the Fixation of Distal Tibia Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients were available for analysis. Costs were collected prospectively over the 12-month follow-up period using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality adjusted life year (QALY) gained, and net monetary benefit. Sensitivity analyses were conducted to test the robustness of cost-effectiveness estimates.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 427 - 484
1 Aug 1981
Uhthoff H Bardos D Liskova-Kiar M

An experimental study is reported of fracture healing in the femora of 36 Beagle dogs, comparing the results of using stainless steel plates with those of using less rigid titanium alloy plates. The alloy plates led to the appearance of a small amount of periosteal callus without any histological evidence of fracture instability, thus allowing the radiological assessment of fracture union. This also produced less bone loss during the remodelling phase. Radiological measurements 24 weeks after osteotomy showed cortical thickness to be reduced by six per cent under titanium alloy and by 19 per cent under stainless steel, while histological measurements showed a total bone loss of 3.7 per cent under titanium alloy and of 11 per cent under stainless steel plates. Removal of the titanium alloy plates after eight weeks followed by a recovery period of 16 weeks produced an increase of cortical thickness of 69 per cent and a gain in total bone mass of 30 per cent. Titanium alloy plates also produced less soft-tissue reaction than stainless steel plates. It is concluded that this alloy is a promising material for internal fixation devices


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1626 - 1632
1 Dec 2018
Medellin MR Fujiwara T Tillman RM Jeys LM Gregory J Stevenson JD Parry M Abudu A

Aims

The aim of this paper was to investigate the prognostic factors for local recurrence in patients with pathological fracture through giant cell tumours of bone (GCTB).

Patients and Methods

A total of 107 patients presenting with fractures through GCTB treated at our institution (Royal Orthopaedic Hospital, Birmingham, United Kingdom) between 1995 and 2016 were retrospectively studied. Of these patients, 57 were female (53%) and 50 were male (47%).The mean age at diagnosis was 33 years (14 to 86). A univariate analysis was performed, followed by multivariate analysis to identify risk factors based on the treatment and clinical characteristics.


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 404 - 425
1 Aug 1964
Nevile Burwell H Charnley AD

1. A simple method of internal fixation of adult forearm fractures which gives consistent good results is necessary because the closed method of treatment is of limited application. 2. Open reduction of fractures without rigid internal fixation gives a high proportion of non-union and poor results. 3. Rigid internal fixation with standard plates and screws has been shown to give a low incidence of non-union in this series. 4. A three and a half inch long plate with six screws is suitable for most fractures, but if there is moderate or severe comminution, or if there is a segmental fracture, longer plates and more screws should be used to provide sound fixation. 5. Severely comminuted fractures with large avascular bone fragments should have the addition of a bone graft at the time of the plating operation in order that union may be assured. Thin strips of iliac bone are preferred. 6. Rigid plating is considered to be the most satisfactory treatment for open fractures. 7. Immobilisation of the limb after operation is not necessary and is undesirable if the fixation is rigid. 8. The functional results of this treatment are good and seemingly better than those achieved by other methods. 9. Serious complications of the plating operation are few and avoidable