Advertisement for orthosearch.org.uk
Results 701 - 720 of 1094
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 367 - 372
1 May 1985
Fyfe I Mossad M Holdsworth B

This study was designed to compare the rigidity of the more commonly used techniques of internal fixation of fractures of the olecranon. Cadaveric elbow joints were mounted in a jig and controlled osteotomies performed to simulate transverse, oblique or comminuted fractures. Five techniques of internal fixation were tested by measuring movement at the fracture site after applying a bending moment to the ulna. At transverse osteotomies tension-band wiring with two tightening knots allowed least movement even at high loads. Intramedullary cancellous screw fixation gave erratic results; adding a tension band with a single know was little better. In oblique osteotomies, no statistically significant difference was shown between one-third tubular plate fixation and double-knot wiring. Comminuted osteotomies were held most rigidly by contoured one-third tubular plate fixation


Bone & Joint 360
Vol. 6, Issue 4 | Pages 18 - 20
1 Aug 2017


Bone & Joint 360
Vol. 6, Issue 4 | Pages 16 - 18
1 Aug 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1397 - 1401
1 Oct 2005
Walmsley PJ Kelly MB Hill RMF Brenkel I

The routine use of surgical drains in total hip arthroplasty remains controversial. They have not been shown to decrease the rate of wound infection significantly and can provide a retrograde route for it. Their use does not reduce the size or incidence of post-operative wound haematomas. This prospective, randomised study was designed to evaluate the role of drains in routine total hip arthroplasty. We investigated 552 patients (577 hips) undergoing unilateral or bilateral total hip arthroplasty who had been randomised to either having a drain for 24 hours or not having a drain. All patients followed standardised pre-, intra-, and post-operative regimes and were independently assessed using the Harris hip score before operation and at six, 18 and 36 months follow-up. The rate of superficial and deep infection was 2.9% and 0.4%, respectively, in the drained group and 4.8% and 0.7%, respectively in the undrained group. One patient in the undrained group had a haematoma which did not require drainage or transfusion. The rate of transfusion after operation in the drained group was significantly higher than for undrained procedures (p < 0.042). The use of a drain did not influence the post-operative levels of haemoglobin, the revision rates, Harris hip scores, the length of hospital stay or the incidence of thromboembolism. We conclude that drains provide no clear advantage at total hip arthroplasty, represent an additional cost, and expose patients to a higher risk of transfusion


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 732 - 740
1 Jun 2017
Meermans G Konan S Das R Volpin A Haddad FS

Aims

The most effective surgical approach for total hip arthroplasty (THA) remains controversial. The direct anterior approach may be associated with a reduced risk of dislocation, faster recovery, reduced pain and fewer surgical complications. This systematic review aims to evaluate the current evidence for the use of this approach in THA.

Materials and Methods

Following the Cochrane collaboration, an extensive literature search of PubMed, Medline, Embase and OvidSP was conducted. Randomised controlled trials, comparative studies, and cohort studies were included. Outcomes included the length of the incision, blood loss, operating time, length of stay, complications, and gait analysis.


Bone & Joint Research
Vol. 6, Issue 6 | Pages 366 - 375
1 Jun 2017
Neves N Linhares D Costa G Ribeiro CC Barbosa MA

Objectives

This systematic review aimed to assess the in vivo and clinical effect of strontium (Sr)-enriched biomaterials in bone formation and/or remodelling.

Methods

A systematic search was performed in Pubmed, followed by a two-step selection process. We included in vivo original studies on Sr-containing biomaterials used for bone support or regeneration, comparing at least two groups that only differ in Sr addition in the experimental group.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 23 - 25
1 Apr 2017


Bone & Joint Research
Vol. 6, Issue 5 | Pages 259 - 269
1 May 2017
McKirdy A Imbuldeniya AM

Objectives

To assess the clinical and cost-effectiveness of a virtual fracture clinic (VFC) model, and supplement the literature regarding this service as recommended by The National Institute for Health and Care Excellence (NICE) and the British Orthopaedic Association (BOA).

Methods

This was a retrospective study including all patients (17 116) referred to fracture clinics in a London District General Hospital from May 2013 to April 2016, using hospital-level data. We used interrupted time series analysis with segmented regression, and direct before-and-after comparison, to study the impact of VFCs introduced in December 2014 on six clinical parameters and on local Clinical Commissioning Group (CCG) spend. Student’s t-tests were used for direct comparison, whilst segmented regression was employed for projection analysis.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 33 - 34
1 Apr 2017


Bone & Joint Research
Vol. 6, Issue 4 | Pages 224 - 230
1 Apr 2017
Cool P Cribb G

Objectives

In this cross sectional study, the impact and the efficacy of a surveillance programme for sarcomas of the extremities was analysed.

Methods

All patients who had treatment with curative intent for a high-grade sarcoma and were diagnosed before 2014 were included and followed for a minimum of two years.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 451 - 457
1 Apr 2017
Gromov K Bersang A Nielsen CS Kallemose T Husted H Troelsen A

Aims

The aim of this study was to identify patient- and surgery-related risk factors for sustaining an early periprosthetic fracture following primary total hip arthroplasty (THA) performed using a double-tapered cementless femoral component (Bi-Metric femoral stem; Biomet Inc., Warsaw, Indiana).

Patients and Methods

A total of 1598 consecutive hips, in 1441 patients receiving primary THA between January 2010 and June 2015, were retrospectively identified. Level of pre-operative osteoarthritis, femoral Dorr type and cortical index were recorded. Varus/valgus placement of the stem and canal fill ratio were recorded post-operatively. Periprosthetic fractures were identified and classified according to the Vancouver classification. Regression analysis was performed to identify risk factors for early periprosthetic fracture.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 30 - 31
1 Jun 2017


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 421 - 431
1 Apr 2017
Veldman HD Heyligers IC Grimm B Boymans TAEJ

Aims

Our aim was to prepare a systematic review and meta-analysis to compare the outcomes of cemented and cementless hemiarthroplasty of the hip, in elderly patients with a fracture of the femoral neck, to investigate the mortality, complications, length of stay in hospital, blood loss, operating time and functional results.

Materials and Methods

A systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines on randomised controlled trials (RCTs), studying current generation designs of stem only. The synthesis of results was done of pooled data, with a fixed effects or random effects model, based on heterogeneity.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 37 - 43
1 Jan 2017
Garland A Gordon M Garellick G Kärrholm J Sköldenberg O Hailer NP

Aims

It has been suggested that cemented fixation of total hip arthroplasty (THA) is associated with an increased peri-operative mortality compared with cementless THA. Our aim was to investigate this through a nationwide matched cohort study adjusting for age, comorbidity, and socioeconomic background.

Patients and Methods

A total of 178 784 patients with osteoarthritis who underwent either cemented or cementless THA from the Swedish Hip Arthroplasty Register were matched with 862 294 controls from the general population. Information about the causes of death, comorbidities, and socioeconomic background was obtained. Mortality within the first 90 days after the operation was the primary outcome measure.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 749 - 758
1 Jun 2017
García-Rey E Cruz-Pardos A García-Cimbrelo E

Aims

To determine the effect of a change in design of a cementless ceramic acetabular component in fixation and clinical outcome after total hip arthroplasty

Patients and Methods

We compared 342 hips (302 patients) operated between 1999 and 2005 with a relatively smooth hydroxyapatite coated acetabular component (group 1), and 337 hips (310 patients) operated between 2006 and 2011 using a similar acetabular component with a macrotexture on the entire outer surface of the component (group 2). The mean age of the patients was 53.5 (14 to 70) in group 1 and 53.0 (15 to 70) in group 2. The mean follow-up was 12.7 years (10 to 17) for group 1 and 7.2 years (4 to 10) for group 2.


Bone & Joint 360
Vol. 6, Issue 1 | Pages 34 - 36
1 Feb 2017


Bone & Joint 360
Vol. 6, Issue 1 | Pages 10 - 13
1 Feb 2017


Bone & Joint Research
Vol. 6, Issue 3 | Pages 162 - 171
1 Mar 2017
Walker JA Ewald TJ Lewallen E Van Wijnen A Hanssen AD Morrey BF Morrey ME Abdel MP Sanchez-Sotelo J

Objectives

Sustained intra-articular delivery of pharmacological agents is an attractive modality but requires use of a safe carrier that would not induce cartilage damage or fibrosis. Collagen scaffolds are widely available and could be used intra-articularly, but no investigation has looked at the safety of collagen scaffolds within synovial joints. The aim of this study was to determine the safety of collagen scaffold implantation in a validated in vivo animal model of knee arthrofibrosis.

Materials and Methods

A total of 96 rabbits were randomly and equally assigned to four different groups: arthrotomy alone; arthrotomy and collagen scaffold placement; contracture surgery; and contracture surgery and collagen scaffold placement. Animals were killed in equal numbers at 72 hours, two weeks, eight weeks, and 24 weeks. Joint contracture was measured, and cartilage and synovial samples underwent histological analysis.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 666 - 673
1 May 2017
Werthel J Lonjon G Jo S Cofield R Sperling JW Elhassan BT

Aims

In the initial development of total shoulder arthroplasty (TSA), the humeral component was usually fixed with cement. Cementless components were subsequently introduced. The aim of this study was to compare the long-term outcome of cemented and cementless humeral components in arthroplasty of the shoulder.

Patients and Methods

All patients who underwent primary arthroplasty of the shoulder at our institution between 1970 and 2012 were included in the study. There were 4636 patients with 1167 cemented humeral components and 3469 cementless components. Patients with the two types of fixation were matched for nine different covariates using a propensity score analysis. A total of 551 well-balanced pairs of patients with cemented and cementless components were available after matching for comparison of the outcomes. The clinical outcomes which were analysed included loosening of the humeral component determined at revision surgery, periprosthetic fractures, post-operative infection and operating time.


Bone & Joint Research
Vol. 6, Issue 5 | Pages 351 - 357
1 May 2017
Takahashi E Kaneuji A Tsuda R Numata Y Ichiseki T Fukui K Kawahara N

Objectives

Favourable results for collarless polished tapered stems have been reported, and cement creep due to taper slip may be a contributing factor. However, the ideal cement thickness around polished stems remains unknown. We investigated the influence of cement thickness on stem subsidence and cement creep.

Methods

We cemented six collarless polished tapered (CPT) stems (two stems each of small, medium and large sizes) into composite femurs that had been reamed with a large CPT rasp to achieve various thicknesses of the cement mantle. Two or three tantalum balls were implanted in the proximal cement in each femur. A cyclic loading test was then performed for each stem. The migration of the balls was measured three-dimensionally, using a micro-computed tomography (CT) scanner, before and after loading. A digital displacement gauge was positioned at the stem shoulder, and stem subsidence was measured continuously by the gauge. Final stem subsidence was measured at the balls at the end of each stem.