Disruption of the interosseous membrane is easily
missed in patients with Essex-Lopresti syndrome. None of the imaging
techniques available for diagnosing disruption of the interosseous
membrane are completely dependable. We undertook an investigation to identify whether a simple intra-operative
test could be used to diagnose disruption of the interosseous membrane
during surgery for fracture of the radial head and to see if the
test was reproducible. We studied 20 cadaveric forearms after excision of the radial
head, ten with and ten without disruption of the interosseous membrane.
On each forearm, we performed the radius joystick test: moderate
lateral traction was applied to the radial neck with the forearm
in maximal pronation, to look for lateral displacement of the proximal radius
indicating that the interosseous membrane had been disrupted. Each
of six surgeons (three junior and three senior) performed the test
on two consecutive days. Intra-observer agreement was 77% (95% confidence interval (CI)
67 to 85) and interobserver agreement was 97% (95% CI 92 to 100).
Sensitivity was 100% (95% CI 97 to 100), specificity 88% (95% CI
81 to 93), positive predictive value 90% (95% CI 83 to 94), and
negative predictive value 100%). This cadaveric study suggests that the radius joystick test may
be useful for detecting disruption of the interosseous membrane
in patients undergoing open surgery for fracture of the radial head
and is reproducible. A confirmatory study
Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis. This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant complication occurred in one patient who developed a severe complex regional pain syndrome. There were no patients with secondary instability of the elbow, implant loosening, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. Our experience, combined with that of other authors using this device, has encouraged us to continue using the Judet prosthesis in comminuted fractures of the elbow where instability is a potential problem.
Since the Oxford knee was first used unicompartmentally
in 1982, a small number of bearings have fractured. Of 14 retrieved
bearings, we examined ten samples with known durations
The clinical diagnosis of a partial tear of the
anterior cruciate ligament (ACL) is still subject to debate. Little
is known about the contribution of each ACL bundle during the Lachman
test. We investigated this using six fresh-frozen cadaveric lower
limbs. Screws were placed in the femora and tibiae as fixed landmarks
for digitisation of the bone positions. The femur was secured horizontally
in a clamp. A metal hook was screwed to the tibial tubercle and
used to apply a load of 150 N directed anteroposteriorly to the
tibia to simulate the Lachman test. The knees then received constant
axial compression and 3D knee kinematic data were collected by digitising
the screw head positions in 30° flexion under each test condition.
Measurements of tibial translation and rotation were made, first with
the ACL intact, then after sequential cutting of the ACL bundles,
and finally after complete division of the ACL. Two-way analysis
of variance analysis was performed. During the Lachman test, in all knees and in all test conditions,
lateral tibial translation exceeded that on the medial side. With
an intact ACL, both anterior and lateral tibial landmarks translated
significantly more than those on the medial side (p <
0.001).
With sequential division of the ACL bundles, selective cutting of
the posterolateral bundle (PLB) did not increase translation of
any landmark compared with when the ACL remained intact. Cutting the
anteromedial bundle (AMB) resulted in an increased anterior translation
of all landmarks. Compared to the intact ACL, when the ACL was fully
transected a significant increase in anterior translation of all
landmarks occurred (p <
0.001). However, anterior tibial translation
was almost identical after AMB or complete ACL division. We found that the AMB confers its most significant contribution
to tibial translation during the Lachman test, whereas the PLB has
a negligible effect on anterior translation. Section of the PLB
had a greater effect on increasing the internal rotation of the
tibia than the AMB. However, its contribution of a mean of 2.8°
amplitude remains low. The clinical relevance of our investigation
suggests that, based on anterior tibial translation only, one cannot distinguish
between a full ACL and an isolated AMB tear. Isolated PLB tears
cannot be detected solely by the Lachman test, as this bundle probably
contributes more resistance to the pivot shift.
We have reviewed a group of patients with iliopsoas impingement after total hip replacement with radiological evidence of a well-fixed malpositioned or oversized acetabular component. A consecutive series of 29 patients (30 hips) was assessed. All had undergone a trial of conservative management with no improvement in their symptoms. Eight patients (eight hips) preferred continued conservative management (group 1), and 22 hips had either an iliopsoas tenotomy (group 2) or revision of the acetabular component and debridement of the tendon (group 3), based on clinical and radiological findings. Patients were followed clinically for at least two years, and 19 of the 22 patients (86.4%) who had surgery were contacted by phone at a mean of 7.8 years (5 to 9) post-operatively. Conservative management failed in all eight hips. At the final follow-up, operative treatment resulted in relief of pain in 18 of 22 hips (81.8%), with one hip in group 2 and three in group 3 with continuing symptoms. The Harris Hip Score was significantly better in the combined groups 2 and 3 than in group 1. There was a significant rate of complications in group 3. This group initially had better functional scores, but at final follow-up these were no different from those in group 2. Tenotomy of the iliopsoas and revision of the acetabular component are both successful surgical options. Iliopsoas tenotomy provided the same functional results as revision of the acetabular component and avoided the risks of the latter procedure.
We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months. Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative complications occurred in the AO-plate group, the difference between the two groups was not statistically significant.
We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts were used for the management of Type III defects in 23 hips. A total of five hips showed radiological failure at a mean follow-up of 6.7 years (4.5 to 9.3), two of which were infected. The mean pre-operative Merle d’Aubigné score was 10 (5 to 15) This clinical study indicates that revision total hip replacement using the Kerboull-type acetabular reinforcement device with bone allografts yielded satisfactory mid-term results.
Abnormal knee kinematics following reconstruction
of the anterior cruciate ligament may exist despite an apparent resolution
of tibial laxity and functional benefit. We performed upright, weight-bearing
MR scans of both knees in the sagittal plane at different angles
of flexion to determine the kinematics of the knee following unilateral reconstruction
(n = 12). The uninjured knee acted as a control. Scans were performed
pre-operatively and at three and six months post-operatively. Anteroposterior
tibial laxity was determined using an arthrometer and patient function
by validated questionnaires before and after reconstruction. In
all the knees with deficient anterior cruciate ligaments, the tibial
plateau was displaced anteriorly and internally rotated relative
to the femur when compared with the control contralateral knee,
particularly in extension and early flexion (mean lateral compartment displacement:
extension 7.9 mm ( Our results show that despite improvement in laxity and functional
benefit, abnormal knee kinematics remain at six months and actually
deteriorate from three to six months following reconstruction of
the anterior cruciate ligament.
Hand function was evaluated in 105 patients who had been operated on in early infancy for brachial plexus birth palsy. The mean follow-up after surgery was for 13.4 years (5.0 to 31.5). Fine sensation, stereognosis, grip and pinch strength and the Raimondi scale were recorded. Fine sensation was normal in 34 of 49 patients (69%) with C5–6 injury, 15 of 31 (48%) with C5–7 and in 8 of 25 (32%) with total injury. Loss of protective sensation or absent sensation was noted in some palmar areas of the hand in 12 of 105 patients (11%). Normal stereognosis was recorded in 88 of the 105 patients (84%), whereas only 9 of the 105 (9%) had normal grip strength. The mean Raimondi scale scores were 4.57 (3 to 5) (C5–6), 4.26 (1 to 5) (C5–7) and 2.16 (0 to 5) in patients with total injury. The location of impaired sensation was related to the distribution of the root injury. Avulsion type of injury correlated with poor recovery of hand function.
We performed a meta-analysis of modern total
joint replacement (TJR) to determine the post-operative mortality and
the cause of death using different thromboprophylactic regimens
as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent
anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran,
fondaparinux or rivaroxaban); 3) Potent anticoagulation combined
(PAC) with regional anaesthesia and/or pneumatic compression devices
(PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia
and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional
anaesthesia, PCDs and aspirin in low-risk patients. Cause of death
was classified as autopsy proven, clinically certain or unknown.
Deaths were grouped into cardiopulmonary excluding pulmonary embolism
(PE), PE, bleeding-related, gastrointestinal, central nervous system,
and others (miscellaneous). Meta-analysis based on fixed effects
or random effects models was used for pooling incidence data. In all, 70 studies were included (99 441 patients; 373 deaths).
The mortality was lowest in the MM (0.2%) and WC (0.2%) groups.
The most frequent cause of death was cardiopulmonary (47.9%), followed
by PE (25.4%) and bleeding (8.9%). The proportion of deaths due
to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%;
PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher
in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%;
PAC, 10.8%) but the differences were not statistically significant. Our study demonstrated that the routine use of PA does not reduce
the overall mortality or the proportion of deaths due to PE.
We present a patient who underwent delayed sub-periosteal hemipelvectomy for control of infection and to enable soft-tissue cover after trauma. At four months after amputation, clinical examination and radiographs demonstrated almost complete re-ossification of the hemipelvis. This has allowed the patient to regain sitting balance and to use a walking prosthesis designed for patients following disarticulation of the hip. After 14 months from injury, no perineal hernia has developed, and no dysfunction of pelvic organs is attributable to heterotopic bone formation or adhesions. The patient’s mobility with a prosthesis is similar to that expected of a through-hip amputee.
It has been suggested that a supramalleolar osteotomy can return the load distribution in the ankle joint to normal. However, due to the lack of biomechanical data, this supposition remains empirical. The purpose of this biomechanical study was to determine the effect of simulated supramalleolar varus and valgus alignment on the tibiotalar joint pressure, in order to investigate its relationship to the development of osteoarthritis. We also wished to establish the rationale behind corrective osteotomy of the distal tibia. We studied 17 cadaveric lower legs and quantified the changes in pressure and force transfer across the tibiotalar joint for various degrees of varus and valgus deformity in the supramalleolar area. We assumed that a supramalleolar osteotomy which created a varus deformity of the ankle would result in medial overload of the tibiotalar joint. Similarly, we thought that creating a supramalleolar valgus deformity would cause a shift in contact towards the lateral side of the tibiotalar joint. The opposite was observed. The restricting role of the fibula was revealed by carrying out an osteotomy directly above the syndesmosis. In end-stage ankle osteoarthritis with either a valgus or varus deformity, the role of the fibula should be appreciated and its effect addressed where appropriate.
We carried out a prospective study of 71 patients who had undergone reconstruction of the anterior cruciate ligament with the ABC scaffold. Their mean age was 28 years (18 to 50). All had either sub-acute or chronic traumatic deficiency of the ligament. The mean period of follow-up was five years (four to seven). Assessment included the use of the International Knee Documentation Committee score, the modified Lysholm score, the Tegner Activity score, the Knee Injury and Osteoarthritis Outcome score and measurement with the KT-1000 arthrometer. Two patients had mild recurrent synovitis. There were no infections and no failures of the ligament. During the period of study, two patients sustained a traumatic fracture of a femoral condyle. The implants retained their integrity in both cases. All patients returned to their previous or enhanced levels of daily activity by three months after operation and 56 (79%) achieved their pre-injury level of sporting activity by six months. The patients who were competing in National level sports returned to play at one level less after operation than before. The Lysholm score showed that 58% of the patients (41) were excellent, 34% (24) good, and 8% (6) fair, with a mean post-operative score of 93. According to the International Knee Documentation Committee score, 35% of knees (25) were ‘normal’, 52% (37) ‘nearly normal’ and 13% (9) ‘abnormal’. Complete satisfaction was noted in 90% of patients (64). The development of osteoarthritis and the management of anterior cruciate deficiency associated with laxity of the medial collateral ligament remains uncertain. Our results indicate that in the medium-term, the ABC ligament scaffold is suitable and effective when early and safe return to unrestricted activities is demanded. We acknowledge the current general hostility towards reconstruction of the anterior cruciate ligament with artificial materials following reports of early failure and chronic synovitis associatiated with the production of particulate debris. We did not encounter these problems.
We prospectively evaluated the one- and seven-year results of the Weil osteotomy for the treatment of metatarsalgia with subluxed or dislocated metatarsophalangeal joints in 25 feet of 24 patients. Good to excellent results were achieved in 21 feet (84%) after one year and in 22 (88%) after seven years. The American Orthopaedic Foot and Ankle Society score significantly improved from 48 (
In order to identify the risk factors and the incidence of post-operative spinal epidural haematoma, we analysed the records of 14 932 patients undergoing spinal surgery between 1984 and 2002. Of these, 32 (0.2%) required re-operation within one week of the initial procedure and had an International Classification of Diseases (ICD)-9 code for haematoma complicating a procedure (998.12). As controls, we selected those who had undergone a procedure of equal complexity by the same surgeon but who had not developed this complication. Risks identified before operation were older than 60 years of age, the use of pre-operative non-steroidal anti-inflammatories and Rh-positive blood type. Those during the procedure were involvement of more than five operative levels, a haemoglobin <
10 g/dL, and blood loss >
1 L, and after operation an international normalised ratio >
2.0 within the first 48 hours. All these were identified as significant (p <
0.03). Well-controlled anticoagulation and the use of drains were not associated with an increased risk of post-operative spinal epidural haematoma.
We investigated the safety and efficacy of treating osteoporotic vertebral compression fractures with an intravertebral cleft by balloon kyphoplasty. Our study included 27 patients who were treated in this way. The mean follow-up was 38.2 months (24 to 54). The anterior and middle heights of the vertebral body and the kyphotic angle were measured on standing lateral radiographs before surgery, one day after surgery, and at final follow-up. Leakage of cement was determined by CT scans. A visual analogue scale and the Oswestry disability index were chosen to evaluate pain and functional activity. Statistically significant improvements were found between the pre- and post-operative assessments (p <
0.05) but not between the post-operative and final follow-up assessments (p >
0.05). Asymptomatic leakage of cement into the paravertebral vein occurred in one patient, as did leakage into the intervertebral disc in another patient. We suggest that balloon kyphoplasty is a safe and effective minimally invasive procedure for the treatment of osteoporotic vertebral compression fractures with an intravertebral cleft.
In a prospective, randomised study on the repair of tears of the rotator cuff we compared the clinical results of two suture techniques for which different suture materials were used. We prospectively randomised 100 patients with tears of the rotator cuff into two groups. Group 1 had transosseous repair with No. 3 Ethibond using modified Mason-Allen sutures and group 2 had transosseous repair with 1.0 mm polydioxanone cord using modified Kessler sutures. After 24 to 30 months the patients were evaluated clinically using the Constant score and by ultrasonography. Of the 100 patients, 92 completed the study. No significant statistical difference was seen between the two groups: Constant score, 91% Overall, seven patients had complications which required revision surgery, in four for pain (two in each group) and in three for infection (two in group 1 and one in group 2).
This study evaluated the results of a physeal-sparing technique of intra-articular anterior cruciate ligament (ACL) reconstruction in skeletally immature patients, with particular reference to growth disturbance. Between 1992 and 2007, 57 children with a mean age of 12.2 years (6.8 to 14.5) underwent ACL reconstruction using the same technique. At a mean of 5.5 years (2 to 14) after surgery, 56 patients underwent clinical and radiological evaluation. At that time, 49 patients (87.5%) had reached bony maturity and 53 (95%) achieved A or B according to the IKDC 2000 classification. Four patients had stopped participation in sports because of knee symptoms, and three patients (5.4%) had a subsequent recurrent ACL injury. There was no clinical or radiological evidence of growth disturbance after a mean growth in stature of 20.0 cm (3 to 38). This study demonstrates that ACL reconstruction sparing the physes in children is a safe technique protecting against meniscal tears and giving better results than reconstruction in adults, without causing significant growth disturbance.
We investigated the role of a functional brace worn for four months in the treatment of patients with an acute isolated tear of the posterior cruciate ligament to determine whether reduction of the posterior tibial translation during the healing period would give an improved final position of the tibia. The initial and follow-up stability was tested by Rolimeter arthrometry and radiography. The clinical outcome was evaluated using the Lysholm score, the Tegner score and the International Knee Documentation Committee scoring system at follow-up at one and two years. In all, 21 patients were studied, 21 of whom had completed one-year and 17 a two-year follow-up. The initial mean posterior sag (Rolimeter measurement) of 7.1 mm (5 to 10) was significantly reduced after 12 months to a mean of 2.3 mm (0 to 6, p <
0.001) and to a mean of 3.2 mm (2 to 7, p = 0.001) after 24 months. Radiological measurement gave similar results. The mean pre-injury Lysholm score was normal at 98 (95 to 100). At follow-up, a slight decrease in the mean values was observed to 94.0 (79 to 100, p = 0.001) at one year and 94.0 (88 to 100, p = 0.027, at two years). We concluded that the posterior cruciate ligament has an intrinsic healing capacity and, if the posteriorly translated tibia is reduced to a physiological position, it can heal with less attentuation. The applied treatment produces a good to excellent functional result.