Advertisement for orthosearch.org.uk
Results 661 - 680 of 4639
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1112 - 1116
1 Aug 2018
Sinha R Weigl D Mercado E Becker T Kedem P Bar-On E

Aims. Guided growth using eight-plates is commonly used for correction of angular limb deformities in growing children. The principle is of tethering at the physeal periphery while enabling growth in the rest of the physis. The method is also applied for epiphysiodesis to correct limb-length discrepancy (LLD). Concerns have been raised regarding the potential of this method to create an epiphyseal deformity. However, this has not been investigated. The purpose of this study was to detect and quantify the occurrence of deformities in the proximal tibial epiphysis following treatment with eight-plates. Patients and Methods. A retrospective study was performed including 42 children at a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion in the proximal tibia for correction of coronal plane deformities or LLD between 2007 and 2015. A total of 64 plates were inserted; 48 plates (34 patients) were inserted to correct angular deformities and 16 plates (8 patients) for LLD. Medical records, Picture Archive and Communication System images, and conventional radiographs were reviewed. Measurements included interscrew angle, lateral and medial plateau slope angles measured between the plateau surface and the line between the ends of the physis, and tibial plateau roof angle defined as 180° minus the sum of both plateau angles. Measurements were compared between radiographs performed adjacent to surgery and those at latest follow-up, and between operated and non-operated plateaus. Statistical analysis was performed using BMDP Statistical Software. Results. Slope angle increased in 31 (49.2%) of operated epiphyses by a mean of 5° (1° to 23°) compared with 29 (31.9%) in non-operated epiphyses (p = 0.043). Roof angle decreased in 29 (46.0%) of operated tibias and in 25 (27.5%) of non-operated ones by a mean of 5° (1° to 18°) (p = 0.028). Slope angle change frequency was similar in patients with LLD, varus and valgus correction (p = 0.37) but roof angle changes were slightly more frequent in LLD (p = 0.059) and correlated with the change in inter screw angles (r = 0.74, p = 0.001). Conclusion. The use of eight-plates in the proximal tibia for deformity correction and limb-length equalization causes a change in the bony morphology of the tibial plateau in a significant number of patients and the effect is more pronounced in the correction of LLD. Cite this article: Bone Joint J 2018;100-B:1112–16


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 33 - 39
1 Jul 2019
Lachiewicz PF O’Dell JA

Aims. There is insufficient evidence to recommend the use of alternative polyethylene bearings in modular, fixed-bearing total knee arthroplasty (TKA). The purpose of this study was to compare standard polyethylene (SP) and highly crosslinked polyethylene (XLP) tibial liners in posterior-stabilized TKA, with osteolysis as the primary outcome and clinical results and the rate of re-operation as the secondary outcomes. Patients and Methods. This is a single-surgeon, prospective randomized study involving one design of modular posterior-stabilized TKA. An analysis of 122 TKAs with an SP compression moulded liner and 123 with an XLP liner was performed, with a mean follow-up of six years (2 to 11). Patients were evaluated clinically using the Knee Society score, Lower Extremity Activity Score (LEAS), and the presence of an effusion, and standard radiographs were assessed for radiolucent lines and osteolytic lesions. Results. Osteolysis was present in four TKAs (3.3%) in the SP group, and no knees in the XLP group (p = 0.06). There were no significant differences between the Knee Society total score, change in total score, knee function score, change in function score, LEAS, and change in LEAS in the two groups. There was a significant difference in the presence of an effusion (10/122 with SP liners, 1/123 with XLP liners; p = 0.02). There was no significant difference in the rate of re-operation between the two groups (p = 0.36). There were no complications related to the XLP liner. Conclusion. At this length of follow-up, there were no advantages and no complications related to the use of this XLP tibial liner. The presence of effusion and small osteolytic lesions was more frequent with SP than XLP liners, but of unknown clinical significance. Cite this article: Bone Joint J 2019;101-B(7 Supple C):33–39


Bone & Joint 360
Vol. 11, Issue 3 | Pages 24 - 28
1 Jun 2022


Bone & Joint Research
Vol. 8, Issue 7 | Pages 304 - 312
1 Jul 2019
Nicholson JA Tsang STJ MacGillivray TJ Perks F Simpson AHRW

Objectives. The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management. Methods. A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”. Results. The use of ultrasound in musculoskeletal medicine has expanded rapidly over the last two decades, but the diagnostic use in fracture management is not routinely practised. Early studies have shown the potential of ultrasound as a valid alternative to radiographs to diagnose common paediatric fractures, to detect occult injuries in adults, and for rapid detection of long bone fractures in the resuscitation setting. Ultrasound has also been shown to be advantageous in the early identification of impaired fracture healing; with the advent of 3D image processing, there is potential for wider adoption. Detection of implant-related infection can be improved by ultrasound mediated sonication of microbiology samples. The use of therapeutic ultrasound to promote union in the management of acute fractures is currently a controversial topic. However, there is strong in vitro evidence that ultrasound can stimulate a biological effect with potential clinical benefit in established nonunions, which supports the need for further investigation. Conclusion. Modern ultrasound image processing has the potential to replace traditional imaging modalities in several areas of trauma practice, particularly in the early prediction of impaired fracture healing. Further understanding of the therapeutic application of ultrasound is required to understand and identify the use in promoting fracture healing. Cite this article: J. A. Nicholson, S. T. J. Tsang, T. J. MacGillivray, F. Perks, A. H. R. W. Simpson. What is the role of ultrasound in fracture management? Diagnosis and therapeutic potential for fractures, delayed unions, and fracture-related infection. Bone Joint Res 2019;8:304–312. DOI: 10.1302/2046-3758.87.BJR-2018-0215.R2


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA. Patients and Methods. In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis. Results. Significant reduction of normalized tracer activity was observed one year postoperatively in tibial and femoral VOIs adjacent to the joint line in the lateral compartment. Patellar VOIs and remaining femoral VOIs demonstrated a significant, diminished normalized tracer activity at final follow-up. Conclusion. The osteoblastic bone activity in the native compartments decreased significantly after treatment of medial end-stage OA with a UKA, implying reduced stress to the subchondral bone in the retained compartments after a UKA. Cite this article: Bone Joint J 2019;101-B:915–921


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 640 - 644
1 May 2022
Gaston MS Wordie SJ Wagner P Hägglund G Robb JE

Aims

The Uppföljningsprogram för cerebral pares (CPUP) Hip Score distinguishes between children with cerebral palsy (CP) at different levels of risk for displacement of the hip. The score was constructed using data from Swedish children with CP, but has not been confirmed in any other population. The aim of this study was to determine the calibration and discriminatory accuracy of this score in children with CP in Scotland.

Methods

This was a total population-based study of children registered with the Cerebral Palsy Integrated Pathway Scotland. Displacement of the hip was defined as a migration percentage (MP) of > 40%. Inclusion criteria were children in Gross Motor Function Classification System (GMFCS) levels III to V. The calibration slope was estimated and Kaplan-Meier curves produced for five strata of CPUP scores to compare the observed with the predicted risk of displacement of the hip at five years. For discriminatory accuracy, the time-dependent area under the receiver operating characteristic curve (AUC) was estimated. In order to analyze differences in the performance of the score between cohorts, score weights, and subsequently the AUC, were re-estimated using the variables of the original score: the child’s age at the first examination, GMFCS level, head shaft angle, and MP of the worst hip in a logistic regression with imputation of outcomes for those with incomplete follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 902 - 909
1 Aug 2019
Innmann MM Merle C Gotterbarm T Ewerbeck V Beaulé PE Grammatopoulos G

Aims. This study of patients with osteoarthritis (OA) of the hip aimed to: 1) characterize the contribution of the hip, spinopelvic complex, and lumbar spine when moving from the standing to the sitting position; 2) assess whether abnormal spinopelvic mobility is associated with worse symptoms; and 3) identify whether spinopelvic mobility can be predicted from static anatomical radiological parameters. Patients and Methods. A total of 122 patients with end-stage OA of the hip awaiting total hip arthroplasty (THA) were prospectively studied. Patient-reported outcome measures (PROMs; Oxford Hip Score, Oswestry Disability Index, and Veterans RAND 12-Item Health Survey Score) and clinical data were collected. Sagittal spinopelvic mobility was calculated as the change from the standing to sitting position using the lumbar lordosis angle (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA), and acetabular anteinclination (AI) from lateral radiographs. The interaction of the different parameters was assessed. PROMs were compared between patients with normal spinopelvic mobility (10° ≤ ∆PT ≤ 30°) or abnormal spinopelvic mobility (stiff: ∆PT < ± 10°; hypermobile: ∆PT > ± 30°). Multiple regression and receiver operating characteristic (ROC) curve analyses were used to test for possible predictors of spinopelvic mobility. Results. Standing to sitting, the hip flexed by a mean of 57° (. sd. 17°), the pelvis tilted backwards by a mean of 20° (. sd. 12°), and the lumbar spine flexed by a mean of 20° (. sd. 14°); strong correlations were detected. There was no difference in PROMs between patients in the different spinopelvic mobility groups. Maximum hip flexion, standing PT, and standing AI were independent predictors of spinopelvic mobility (R. 2. = 0.42). The combined thresholds for standing was PT ≥ 13° and hip flexion ≥ 88° in the clinical examination, and had 90% sensitivity and 63% specificity of predicting spinopelvic stiffness, while SS ≥ 42° had 84% sensitivity and 67% specificity of predicting spinopelvic hypermobility. Conclusion. The hip, on average, accounts for three-quarters of the standing-to-sitting movement, but there is great variation. Abnormal spinopelvic mobility cannot be screened with PROMs. However, clinical and standing radiological features can predict spinopelvic mobility with good enough accuracy, allowing them to be used as reliable screening tools. Cite this article: Bone Joint J 2019;101-B:902–909


Bone & Joint Open
Vol. 3, Issue 5 | Pages 375 - 382
5 May 2022
Teunissen JS van der Oest MJW Selles RW Ulrich DJO Hovius SER van der Heijden B

Aims

The primary aim of this study was to describe long-term patient-reported outcomes after ulna shortening osteotomy for ulna impaction syndrome.

Methods

Overall, 89 patients treated between July 2011 and November 2017 who had previously taken part in a routine outcome evaluation up to 12 months postoperatively were sent an additional questionnaire in February 2021. The primary outcome was the Patient-Rated Wrist and Hand Evaluation (PRWHE) total score. Secondary outcomes included patient satisfaction with treatment results, complications, and subsequent treatment for ulnar-sided wrist pain. Linear mixed models were used to compare preoperative, 12 months, and late follow-up (ranging from four to nine years) PRWHE scores.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 532 - 540
2 May 2022
Martin H Robinson PG Maempel JF Hamilton D Gaston P Safran MR Murray IR

There has been a marked increase in the number of hip arthroscopies performed over the past 16 years, primarily in the management of femoroacetabular impingement (FAI). Insights into the pathoanatomy of FAI, and high-level evidence supporting the clinical effectiveness of arthroscopy in the management of FAI, have fuelled this trend. Arthroscopic management of labral tears with repair may have superior results compared with debridement, and there is now emerging evidence to support reconstructive options where repair is not possible. In situations where an interportal capsulotomy is performed to facilitate access, data now support closure of the capsule in selective cases where there is an increased risk of postoperative instability. Preoperative planning is an integral component of bony corrective surgery in FAI, and this has evolved to include computer-planned resection. However, the benefit of this remains controversial. Hip instability is now widely accepted, and diagnostic criteria and treatment are becoming increasingly refined. Instability can also be present with FAI or develop as a result of FAI treatment. In this annotation, we outline major current controversies relating to decision-making in hip arthroscopy for FAI.

Cite this article: Bone Joint J 2022;104-B(5):532–540.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 470 - 474
7 Jun 2022
Baek J Lee SC Ryu S Kim J Nam CH

Aims

The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up.

Methods

From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 455 - 462
6 Jun 2022
Nwankwo H Mason J Costa ML Parsons N Redmond A Parsons H Haque A Kearney RS

Aims

To compare the cost-utility of removable brace compared with cast in the management of adult patients with ankle fracture.

Methods

A within-trial economic evaluation conducted from the UK NHS and personnel social services (PSS) perspective. Health resources and quality-of-life data were collected as part of the Ankle Injury Rehabilitation (AIR) multicentre, randomized controlled trial over a 12-month period using trial case report forms and patient-completed questionnaires. Cost-utility analysis was estimated in terms of the incremental cost per quality adjusted life year (QALY) gained. Estimate uncertainty was explored by bootstrapping, visualized on the incremental cost-effectiveness ratio plane. Net monetary benefit and probability of cost-effectiveness were evaluated at a range of willingness-to-pay thresholds and visualized graphically.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 383 - 389
1 May 2022
Motesharei A Batailler C De Massari D Vincent G Chen AF Lustig S

Aims

No predictive model has been published to forecast operating time for total knee arthroplasty (TKA). The aims of this study were to design and validate a predictive model to estimate operating time for robotic-assisted TKA based on demographic data, and evaluate the added predictive power of CT scan-based predictors and their impact on the accuracy of the predictive model.

Methods

A retrospective study was conducted on 1,061 TKAs performed from January 2016 to December 2019 with an image-based robotic-assisted system. Demographic data included age, sex, height, and weight. The femoral and tibial mechanical axis and the osteophyte volume were calculated from CT scans. These inputs were used to develop a predictive model aimed to predict operating time based on demographic data only, and demographic and 3D patient anatomy data.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 32 - 35
1 Jun 2022


Bone & Joint 360
Vol. 11, Issue 3 | Pages 17 - 20
1 Jun 2022


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 682 - 690
1 Jun 2019
Scheidegger P Horn Lang T Schweizer C Zwicky L Hintermann B

Aims. There is little information about how to manage patients with a recurvatum deformity of the distal tibia and osteoarthritis (OA) of the ankle. The aim of this study was to evaluate the functional and radiological outcome of addressing this deformity using a flexion osteotomy and to assess the progression of OA after this procedure. Patients and Methods. A total of 39 patients (12 women, 27 men; mean age 47 years (28 to 72)) with a distal tibial recurvatum deformity were treated with a flexion osteotomy, between 2010 and 2015. Nine patients (23%) subsequently required conversion to either a total ankle arthroplasty (seven) or an arthrodesis (two) after a mean of 21 months (9 to 36). A total of 30 patients (77%), with a mean follow-up of 30 months (24 to 76), remained for further evaluation. Functional outcome, sagittal ankle joint OA using a modified Kellgren and Lawrence Score, tibial lateral surface (TLS) angle, and talar offset ratio (TOR) were evaluated on pre- and postoperative weight-bearing radiographs. Results. Postoperatively, the mean score for pain, using a visual analogue scale, decreased significantly from 4.3 to 2.5 points and the mean American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot score improved significantly from 59 to 75 points (both p < 0.001). The mean TLS angle increased significantly by 6.6°; the mean TOR decreased significantly by 0.24 (p < 0.001). Radiological evaluation showed an improvement or no progression of sagittal ankle joint OA in 32 ankles (82%), while seven ankles (18%) showed further progression. Conclusion. A flexion osteotomy effectively improved the congruency of the ankle joint. In 30 patients (77%), the joint could be saved, whereas in nine patients (23%), the treatment delayed a joint-sacrificing procedure. Cite this article: Bone Joint J 2019;101-B:682–690


Bone & Joint 360
Vol. 11, Issue 3 | Pages 40 - 43
1 Jun 2022


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 657 - 662
1 Jun 2022
Barlow T Coco V Shivji F Grassi A Asplin L Thompson P Metcalfe A Zaffagnini S Spalding T

Aims

Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival.

Methods

We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


Bone & Joint Research
Vol. 11, Issue 4 | Pages 229 - 238
11 Apr 2022
Jaeger S Eissler M Schwarze M Schonhoff M Kretzer JP Bitsch RG

Aims

One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined.

Methods

A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD).


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims. Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods. A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results. In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (. sd. 0.16) and 0.00 mm (. sd. 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (. sd. 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (. sd. 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion. This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767