Advertisement for orthosearch.org.uk
Results 661 - 680 of 956
Results per page:
Bone & Joint Research
Vol. 6, Issue 6 | Pages 391 - 398
1 Jun 2017
Lenguerrand E Whitehouse MR Beswick AD Jones SA Porter ML Blom* AW

Objectives

We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI.

Methods

We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 122 - 129
1 Apr 2016
Small SR Rogge RD Malinzak RA Reyes EM Cook PL Farley KA Ritter MA

Objectives

Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone.

Methods

Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 786 - 792
1 Jun 2015
Hutt JRB Farhadnia P Massé V Lavigne M Vendittoli P

This randomised trial evaluated the outcome of a single design of unicompartmental arthroplasty of the knee (UKA) with either a cemented all-polyethylene or a metal-backed modular tibial component. A total of 63 knees in 45 patients (17 male, 28 female) were included, 27 in the all-polyethylene group and 36 in the metal-backed group. The mean age was 57.9 years (39.6 to 76.9). At a mean follow-up of 6.4 years (5 to 9.9), 11 all-polyethylene components (41%) were revised (at a mean of 5.8 years; 1.4 to 8.0) post-operatively and two metal-backed components were revised (at one and five years). One revision in both groups was for unexplained pain, one in the metal-backed group was for progression of osteoarthritis. The others in the all-polyethylene group were for aseptic loosening. The survivorship at seven years calculated by the Kaplan–Meier method for the all-polyethylene group was 56.5% (95% CI 31.9 to 75.2, number at risk 7) and for the metal-backed group was 93.8% (95% CI 77.3 to 98.4, number at risk 16) This difference was statistically significant (p <  0.001). At the most recent follow-up, significantly better mean Western Ontario and McMaster Universities Arthritis Index Scores were found in the all-polyethylene group (13.4 vs 23.0, p = 0.03) but there was no difference in the mean Knee injury and Osteoarthritis Outcome scores (68.8; 41.4 to 99.0 vs 62.6; 24.0 to 100.0), p = 0.36). There were no significant differences for range of movement (p = 0.36) or satisfaction (p = 0.23).

This randomised study demonstrates that all-polyethylene components in this design of fixed bearing UKA had unsatisfactory results with significantly higher rates of failure before ten years compared with the metal-back components.

Cite this article: Bone Joint J 2015;97-B:786–92.


Bone & Joint 360
Vol. 5, Issue 3 | Pages 12 - 14
1 Jun 2016


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 17 - 21
1 Nov 2014
Dunbar MJ Prasad V Weerts B Richardson G

Metal-on-metal resurfacing of the hip (MoMHR) has enjoyed a resurgence in the last decade, but is now again in question as a routine option for osteoarthritis of the hip. Proponents of hip resurfacing suggest that its survival is superior to that of conventional hip replacement (THR), and that hip resurfacing is less invasive, is easier to revise than THR, and provides superior functional outcomes. Our argument serves to illustrate that none of these proposed advantages have been realised and new and unanticipated serious complications, such as pseudotumors, have been associated with the procedure. As such, we feel that the routine use of MoMHR is not justified.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):17–21.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 945 - 951
1 Jul 2016
Clement ND MacDonald D Dall GF Ahmed I Duckworth AD Shalaby HS McKinley J

Aims

To examine the mid-term outcome and cost utility of the BioPro metallic hemiarthroplasty for the treatment of hallux rigidius.

Patients and Methods

We reviewed 97 consecutive BioPro metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum follow-up of five years. There were 19 men and 61 women; their mean age was 55 years (22 to 74). No patient was lost to follow-up.


Bone & Joint 360
Vol. 6, Issue 1 | Pages 10 - 13
1 Feb 2017


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results.

The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies.

Cite this article: Bone Joint J 2016;98-B:892–900.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 276 - 282
1 Feb 2017
Mumith A Coathup M Chimutengwende-Gordon M Aston W Briggs T Blunn G

Aims

Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses.

Materials and Methods

The two novel designs of porous SLS collars, one with small pores (Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 65 - 69
1 Jan 2017
Thienpont E

Objectives

Unicompartmental knee arthroplasty (UKA) is a potential treatment for isolated bone on bone osteoarthritis when limited to a single compartment. The risk for revision of UKA is three times higher than for total knee arthroplasty (TKA). The aim of this review was to discuss the different revision options after UKA failure.

Materials and Methods

A search was performed for English language articles published between 2006 and 2016. After reviewing titles and abstracts, 105 papers were selected for further analysis. Of these, 39 papers were deemed to contain clinically relevant data to be included in this review.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 703 - 709
1 May 2016
Kim Y Kang HG Kim JH Kim S Lin PP Kim HS

Aims

The purpose of the study was to investigate whether closed intramedullary (IM) nailing with percutaneous cement augmentation is better than conventional closed nailing at relieving pain and suppressing tumours in patients with metastases of the femur and humerus.

Patients and Methods

A total of 43 patients (27 men, 16 women, mean age 63.7 years, standard deviation (sd) 12.2; 21 to 84) underwent closed IM nailing with cement augmentation for long bone metastases. A further 27 patients, who underwent conventional closed IM nailing, served as controls. Pain was assessed using a visual analogue scale (VAS) score pre-operatively (pre-operative VAS), one week post-operatively (immediate post-operative VAS), and at six weeks post-operatively (follow-up post-operative VAS). Progression of the tumour was evaluated in subgroups of patients using F-18-fludeoxyglucose (F-18-FDG) positron emission tomography (PET)/computed tomography (CT) and/or bone scintigraphy (BS), at a mean of 8.8 and 7.2 months post-operatively, respectively.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1501 - 1505
1 Nov 2015
Martin JR Watts CD Taunton MJ

Bariatric surgery has been advocated as a means of reducing body mass index (BMI) and the risks associated with total knee arthroplasty (TKA). However, this has not been proved clinically. In order to determine the impact of bariatric surgery on the outcome of TKA, we identified a cohort of 91 TKAs that were performed in patients who had undergone bariatric surgery (bariatric cohort). These were matched with two separate cohorts of patients who had not undergone bariatric surgery. One was matched 1:1 with those with a higher pre-bariatric BMI (high BMI group), and the other was matched 1:2 based on those with a lower pre-TKA BMI (low BMI group).

In the bariatric group, the mean BMI before bariatric surgery was 51.1 kg/m2 (37 to 72), which improved to 37.3 kg/m2 (24 to 59) at the time of TKA. Patients in the bariatric group had a higher risk of, and worse survival free of, re-operation (hazard ratio (HR) 2.6; 95% confidence interval (CI) 1.2 to 6.2; p = 0.02) compared with the high BMI group. Furthermore, the bariatric group had a higher risk of, and worse survival free of re-operation (HR 2.4; 95% CI 1.2 to 3.3; p = 0.2) and revision (HR 2.2; 95% CI 1.1 to 6.5; p = 0.04) compared with the low BMI group.

While bariatric surgery reduced the BMI in our patients, more analysis is needed before recommending bariatric surgery before TKA in obese patients.

Cite this article: Bone Joint J 2015;97-B:1501–5.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 18 - 24
1 Jan 2017
De Martino I D’Apolito R Soranoglou VG Poultsides LA Sculco PK Sculco TP

Aims

The aim of this systematic review was to report the rate of dislocation following the use of dual mobility (DM) acetabular components in primary and revision total hip arthroplasty (THA).

Materials and Methods

A systematic review of the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines was performed. A comprehensive search of Pubmed/Medline, Cochrane Library and Embase (Scopus) was conducted for English articles between January 1974 and March 2016 using various combinations of the keywords “dual mobility”, “dual-mobility”, “tripolar”, “double-mobility”, “double mobility”, “hip”, “cup”, “socket”. The following data were extracted by two investigators independently: demographics, whether the operation was a primary or revision THA, length of follow-up, the design of the components, diameter of the femoral head, and type of fixation of the acetabular component.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 14 - 16
1 Feb 2016


Bone & Joint Research
Vol. 6, Issue 1 | Pages 43 - 51
1 Jan 2017
Nakamura S Tian Y Tanaka Y Kuriyama S Ito H Furu M Matsuda S

Objectives

Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments.

Materials and Methods

Bone models were constructed from one volunteer (normal) and three patients with three different knee deformities (slight, moderate and severe varus). A dynamic musculoskeletal modelling system was used to analyse the kinematics and the tibiofemoral contact force. The contact stress on the tibial insert, and the stress to the resection surface and medial tibial cortex were examined by using finite element analysis.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 9 - 13
1 Jun 2014
Waterson HB Philips JRA Mandalia VI Toms AD

Mechanical alignment has been a fundamental tenet of total knee arthroplasty (TKA) since modern knee replacement surgery was developed in the 1970s. The objective of mechanical alignment was to infer the greatest biomechanical advantage to the implant to prevent early loosening and failure. Over the last 40 years a great deal of innovation in TKA technology has been focusing on how to more accurately achieve mechanical alignment. Recently the concept of mechanical alignment has been challenged, and other alignment philosophies are being explored with the intention of trying to improve patient outcomes following TKA.

This article examines the evolution of the mechanical alignment concept and whether there are any viable alternatives.


Bone & Joint Research
Vol. 6, Issue 2 | Pages 113 - 122
1 Feb 2017
Scholes SC Hunt BJ Richardson VM Langton DJ Smith E Joyce TJ

Objectives

The high revision rates of the DePuy Articular Surface Replacement (ASR) and the DePuy ASR XL (the total hip arthroplasty (THA) version) have led to questions over the viability of metal-on-metal (MoM) hip joints. Some designs of MoM hip joint do, however, have reasonable mid-term performance when implanted in appropriate patients. Investigations into the reasons for implant failure are important to offer help with the choice of implants and direction for future implant designs. One way to assess the performance of explanted hip prostheses is to measure the wear (in terms of material loss) on the joint surfaces.

Methods

In this study, a coordinate measuring machine (CMM) was used to measure the wear on five failed cementless Biomet Magnum/ReCap/ Taperloc large head MoM THAs, along with one Biomet ReCap resurfacing joint. Surface roughness measurements were also taken. The reason for revision of these implants was pain and/or adverse reaction to metal debris (ARMD) and/or elevated blood metal ion levels.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1642 - 1647
1 Dec 2016
Badge R Kailash K Dickson DR Mahalingam S Raza A Birch A Nuttall D Murali SR Hayton MJ Talwalkar S Watts AC Trail IA

Aims

The aims of this study were to evaluate the clinical and radiological outcomes of the Universal-2 total wrist arthroplasty (TWA) in patients with rheumatoid arthritis.

Patients and Methods

This was a retrospective review of all 95 Universal-2 TWAs which were performed in our institution between 2003 to 2012 in patients with rheumatoid arthritis. A total of six patients were lost to follow-up and two died of unrelated causes. A total of ten patients had bilateral procedures. Accordingly, 75 patients (85 TWAs) were included in the study. There were 59 women and 16 men with a mean age of 59 years (26 to 86). The mean follow-up was 53 months (24 to 120). Clinical assessment involved recording pain on a visual analogue score, range of movement, grip strength, the Quick Disabilities of the Arm, Shoulder and Hand (DASH) and Wrightington wrist scores. Any adverse effects were documented with particular emphasis on residual pain, limitation of movement, infection, dislocation and the need for revision surgery.

Radiographic assessment was performed pre-operatively and at three, six and 12 months post-operatively, and annually thereafter. Arthroplasties were assessed for distal row intercarpal fusion and loosening. Radiolucent zones around the components were documented according to a system developed at our institution.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 2 - 8
1 Jun 2014
Phillips JRA Waterson HB Searle DJ Mandalia VI Toms AD

This is the second of a series of reviews of registries. This review looks specifically at worldwide registry data that have been collected on knee arthroplasty, what we have learned from their reports, and what the limitations are as to what we currently know.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 120 - 124
1 Jan 2016
Sculco PK Abdel MP Hanssen AD Lewallen DG

The treatment of bone loss in revision total knee arthroplasty has evolved over the past decade. While the management of small to moderate sized defects has demonstrated good results with a variety of traditional techniques (cement and screws, small metal augments, impaction bone grafting or modular stems), the treatment of severe defects continues to be problematic. The use of a structural allograft has declined in recent years due to an increased failure rate with long-term follow-up and with the introduction of highly porous metal augments that emphasise biological metaphyseal fixation. Recently published mid-term results on the use of tantalum cones in patients with severe bone loss has reaffirmed the success of this treatment strategy.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):120–4.