The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 643 - 647
1 May 2008
Bridgens J Davies S Tilley L Norman P Stockley I

Bone cements produced by different manufacturers vary in their mechanical properties and antibiotic elution characteristics. Small changes in the formulation of a bone cement, which may not be apparent to surgeons, can also affect these properties. The supplier of Palacos bone cement with added gentamicin changed in 2005. We carried out a study to examine the mechanical characteristics and antibiotic elution of Schering-Plough Palacos, Heraeus Palacos and Depuy CMW Smartset bone cements.

Both Heraeus Palacos and Smartset bone cements performed significantly better than Schering-Plough Palacos in terms of mechanical characteristics, with and without additional vancomycin (p < 0.001). All cements show a deterioration in flexural strength with increasing addition of vancomycin, albeit staying above ISO minimum levels. Both Heraeus Palacos and Smartset elute significantly more gentamicin cumulatively than Schering-Plough Palacos. Smartset elutes significantly more vancomycin cumulatively than Heraeus Palacos.

The improved antibiotic elution characteristics of Smartset and Heraeus Palacos are not associated with a deterioration in mechanical properties. Although marketed as the ‘original’ Palacos, Heraeus Palacos has significantly altered mechanical and antibiotic elution characteristics compared with the most commonly-used previous version.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 615 - 619
1 May 2007
Smith R Wood PLR

A consecutive series of 23 patients (25 ankles) with osteoarthritis of the ankle and severe varus or valgus deformity were treated by open arthrodesis using compression screws. Primary union was achieved in 24 ankles one required further surgery to obtain a solid fusion. The high level of satisfaction in this group of patients reinforces the view that open arthrodesis, as opposed to ankle replacement or arthroscopic arthrodesis, continues to be the treatment of choice when there is severe varus or valgus deformity associated with the arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 588 - 588
1 Apr 2005
GRIMER RJ ABUDU A


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 280 - 287
1 Mar 2008
Gwilym SE Pollard TCB Carr AJ

The majority of patients with osteoarthritis present to orthopaedic surgeons seeking relief of pain and associated restoration of function. Although our understanding of the physiology of pain has improved greatly over the last 25 years there remain a number of unexplained pain-related observations in patients with osteoarthritis. The understanding of pain in osteoarthritis, its modulation and treatment is central to orthopaedic clinical practice and in this annotation we explore some of the current concepts applicable. We also introduce the concept of the ‘phantom joint’ as a cause for persistent pain after joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1448 - 1448
1 Oct 2005


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1178 - 1183
1 Sep 2007
Culpan P Le Strat V Piriou P Judet T

We present a series of 16 patients treated between 1993 and 2006 who had a failed total ankle replacement converted to an arthrodesis using bone grafting with internal fixation. We used tricortical autograft from the iliac crest to preserve the height of the ankle, the malleoli and the subtalar joint. A successful arthrodesis was achieved at a mean of three months (1.5 to 4.5) in all patients except one, with rheumatoid arthritis and severe bone loss, who developed a nonunion and required further fixation with an intramedullary nail at one year after surgery, before obtaining satisfactory fusion. The post-operative American Orthopaedic Foot and Ankle Society score improved to a mean of 70 (41 to 87) with good patient satisfaction. From this series and an extensive review of the literature we have found that rates of fusion after failed total ankle replacement in patients with degenerative arthritis are high. We recommend our method of arthrodesis in this group of patients. A higher rate of nonunion is associated with rheumatoid arthritis which should be treated differently.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 888 - 888
1 Jun 2005


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 127 - 132
1 Feb 2008
Warwick D Dahl OE Fisher WD

Thromboprophylaxis remains a controversial subject. A vast amount of epidemiological and trial data about venous thromboembolism has been published over the past 40 years. These data have been distilled and synthesised into guidelines designed to help the practitioner translate this extensive research into ‘evidence-based’ advice.

Guidelines should, in theory, benefit patient care by ensuring that every patient routinely receives the best prophylaxis; without guidelines, it is argued, patients may fail to receive treatment or be exposed to protocols which are ineffective, dangerous or expensive.

Guidelines, however, have not been welcomed or applied universally. In the United States, orthopaedic surgeons have published their concerns about the thromboprophylaxis guidelines prepared by the American College of Chest Physicians. In Britain, controversy persists with many surgeons unconvinced of the risk/benefit, cost/benefit or practicality of thromboprophylaxis. The extended remit of the recent National Institute of Clinical Excellence thromboprophylaxis guidelines has been challenged.

The reasons for this disquiet are addressed in this paper and particular emphasis is placed on how clinically-acceptable guidelines could be developed and applied.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 868 - 873
1 Jul 2007
Ng CY Ballantyne JA Brenkel IJ

We have evaluated the quality of life and functional outcome after unilateral primary total hip replacement (THR). Between 5 January 1998 and 31 July 2000, we recruited a consecutive series of 627 patients undergoing this procedure and investigated them prospectively. Each was assessed before operation and reviewed after six months, 18 months, three years and five years. The Short Form-36 Health Survey (SF-36) and Harris Hip scores were evaluated at each appointment.

All dimensions of the SF-36 except for mental health and general health perception, improved significantly after operation and this was maintained throughout the follow-up. The greatest improvement was seen at the six-month assessment. On average, women reported lower SF-36 scores pre-operatively, but the gender difference did not continue post-operatively. The Harris Hip scores improved significantly after operation, reaching a plateau after 18 months. The improved quality of life was sustained five years after THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 887 - 892
1 Jul 2007
Cohen AT Skinner JA Warwick D Brenkel I

Little is known about the efficacy of graduated compression stockings in preventing venous thromboembolism after hip surgery. We conducted a prospective, randomised single-blind study to determine whether the addition of compression stockings to fondaparinux conferred any additional benefit.

The study included 874 patients, of whom 795 could be evaluated (400 in the fondaparinux group and 395 in the fondaparinux plus compression stocking group). Fondaparinux was given post-operatively for five to nine days, either alone or combined with wearing stockings, which were worn for a mean 42 days (35 to 49).

The study outcomes were venous thromboembolism, or sudden death before day 42. Duplex ultrasonography was scheduled within a week of day 42. Safety outcomes were bleeding and death from venous thromboembolism.

The prevalence of deep-vein thrombosis was similar in the two groups 5.5% (22 of 400) in the fondaparinux group and 4.8 (19 of 395) in the fondaparinux plus stocking group (odds ratio 0.88, 95% confidence interval 0.46 to 1.65, p = 0.69). Major bleeding occurred in only one patient.

The addition of graduated compression stockings to fondaparinux appears to offer no additional benefit over the use of fondaparinux alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1567 - 1573
1 Dec 2007
Kolling C Simmen BR Labek G Goldhahn J

Since the introduction of the first National Arthroplasty Register in Sweden in 1975, many other countries have tried to adopt the successful Scandinavian system. However, not all have overcome the political and practical difficulties of establishing a working register. We have surveyed the current registries to establish the key factors required for an effective database. We have received detailed information from 15 arthroplasty registers worldwide. The legal conditions under which they operate together with the methods of collection and handling of the data differ widely, but the fulfilment of certain criteria is necessary achieve a high degree of completeness of the data to ensure the provision of statistically relevant information.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 336 - 342
1 Mar 2008
Cuff DJ Virani NA Levy J Frankle MA Derasari A Hines B Pupello DR Cancio M Mighell M

We retrospectively reviewed 21 patients (22 shoulders) who presented with deep infection after surgery to the shoulder, 17 having previously undergone hemiarthroplasty and five open repair of the rotator cuff. Nine shoulders had undergone previous surgical attempts to eradicate their infection. The diagnosis of infection was based on a combination of clinical suspicion (16 shoulders), positive frozen sections (> 5 polymorphonuclear leukocytes per high-power field) at the time of revision (15 shoulders), positive intra-operative cultures (18 shoulders) or the pre-operative radiological appearances. The patients were treated by an extensive debridement, intravenous antibiotics, and conversion to a reverse shoulder prosthesis in either a single- (10 shoulders) or a two-stage (12 shoulders) procedure.

At a mean follow-up of 43 months (25 to 66) there was no evidence of recurrent infection. All outcome measures showed statistically significant improvements. Mean abduction improved from 36.1° (sd 27.8) pre-operatively to 75.7° (sd 36.0) (p < 0.0001), the mean forward flexion from 43.1° (sd 33.5) to 79.5° (sd 43.2) (p = 0.0003), and mean external rotation from 10.2° (sd 18.7) to 25.4° (sd 23.5) (p = 0.0037). There was no statistically significant difference in any outcome between the single-stage and the two-stage group.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1092 - 1097
1 Aug 2007
Smith LK Williams DH Langkamer VG

Clinical, haematological or economic benefits of post-operative blood salvage with autologous blood re-transfusion have yet to be clearly demonstrated for primary total hip replacement. We performed a prospective randomised study to analyse differences in postoperative haemoglobin levels and homologous blood requirements in two groups of patients undergoing primary total hip replacement.

A series of 158 patients was studied. In one group two vacuum drains were used and in the other the ABTrans autologous retransfusion system. A total of 58 patients (76%) in the re-transfusion group received autologous blood. There was no significant difference in the mean post-operative haemoglobin levels in the two groups. There were, however, significantly fewer patients with post-operative haemoglobin values less than 9.0 g/dl and significantly fewer patients who required transfusion of homologous blood in the re-transfusion group. There was also a small overall cost saving in this group.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 107 - 110
1 Jan 2006
Watts AC Howie CR Simpson AHRW

The risk of venous thromboembolism in patients following arthroplasty may be reduced by continuing chemical thromboprophylaxis for up to 35 days post-operatively. This prospective cohort study investigated the compliance of 40 consecutive consenting patients undergoing lower limb arthroplasty with self-administration of a recommended subcutaneous chemotherapeutic agent for six weeks after surgery. Compliance was assessed by examination of the patient for signs of injection, number of syringes used, and a self-report diary at the end of the six-week period. A total of 40 patients, 15 men and 25 women, were recruited. One woman was excluded because immediate post-operative complications prevented her participation. Self-administration was considered feasible in 87% of patients (95% confidence interval (CI) 76 to 98) at the time of discharge. Among this group of 34 patients, 29 (85%) were compliant (95% CI 73 to 97). Patients can learn to self-administer subcutaneous injections of thromboprophylaxis, and compliance with extended prophylaxis to six weeks is good.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 562 - 569
1 May 2008
Daniel J Pradhan A Pradhan C Ziaee H Moss M Freeman J McMinn DJW

We report a retrospective review of the incidence of venous thromboembolism in 463 consecutive patients who underwent primary total hip arthroplasty (487 procedures). Treatment included both total hip replacement and hip resurfacing, and the patients were managed without anticoagulants. The thromboprophylaxis regimen included an antiplatelet agent, generally aspirin, hypotensive epidural anaesthesia, elastic compression stockings and early mobilisation. In 258 of these procedures (244 patients) performed in 2005 (cohort A) mechanical compression devices were not used, whereas in 229 (219 patients) performed during 2006 (cohort B) bilateral intermittent pneumatic calf compression was used.

All operations were performed through a posterior mini-incision approach. Patients who required anticoagulation for pre-existing medical problems and those undergoing revision arthroplasty were excluded. Doppler ultrasonographic screening for deep-vein thrombosis was performed in all patients between the fourth and sixth post-operative days. All patients were reviewed at a follow-up clinic six to ten weeks after the operation. In addition, reponse to a questionnaire was obtained at the end of 12 weeks post-operatively.

No symptomatic calf or above-knee deep-vein thrombosis or pulmonary embolism occurred. In 25 patients in cohort A (10.2%) and in ten patients in cohort B (4.6%) asymptomatic calf deep-vein thromboses were detected ultrasonographically. This difference was statistically significant (p = 0.03). The regimen followed by cohort B offers the prospect of a low incidence of venous thromboembolism without subjecting patients to the higher risk of bleeding associated with anticoagulant use.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 997 - 999
1 Jul 2005
Reilly J Noone A Clift A Cochrane L Johnston L Rowley DI Phillips G Sullivan F

Post-discharge surveillance of surgical site infection is necessary if accurate rates of infection following surgery are to be available. We undertook a prospective study of 376 knee and hip replacements in 366 patients in order to estimate the rate of orthopaedic surgical site infection in the community. The inpatient infection was 3.1% and the post-discharge infection rate was 2.1%. We concluded that the use of telephone interviews of patients to identify the group at highest risk of having a surgical site infection (those who think they have an infection) with rapid follow-up by a professional trained to diagnose infection according to agreed criteria is an effective method of identifying infection after discharge from hospital.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 94 - 99
1 Jan 2007
Bottner F Wegner A Winkelmann W Becker K Erren M Götze C

This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement.

The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis.

C-reactive protein (> 3.2 md/dl) and interleukin-6 (> 12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 vs 0.96). Combining C-reactive protein and interleukin-6 identifies all patients with deep infection of the implant. Procalcitonin (> 0.3 ng/ml) and TNF-α (> 40 ng/ml) are very specific (0.98 vs 0.94) but have a low sensitivity (0.33 vs 0.43).

The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1397 - 1401
1 Oct 2005
Walmsley PJ Kelly MB Hill RMF Brenkel I

The routine use of surgical drains in total hip arthroplasty remains controversial. They have not been shown to decrease the rate of wound infection significantly and can provide a retrograde route for it. Their use does not reduce the size or incidence of post-operative wound haematomas. This prospective, randomised study was designed to evaluate the role of drains in routine total hip arthroplasty.

We investigated 552 patients (577 hips) undergoing unilateral or bilateral total hip arthroplasty who had been randomised to either having a drain for 24 hours or not having a drain. All patients followed standardised pre-, intra-, and post-operative regimes and were independently assessed using the Harris hip score before operation and at six, 18 and 36 months follow-up.

The rate of superficial and deep infection was 2.9% and 0.4%, respectively, in the drained group and 4.8% and 0.7%, respectively in the undrained group. One patient in the undrained group had a haematoma which did not require drainage or transfusion. The rate of transfusion after operation in the drained group was significantly higher than for undrained procedures (p < 0.042). The use of a drain did not influence the post-operative levels of haemoglobin, the revision rates, Harris hip scores, the length of hospital stay or the incidence of thromboembolism. We conclude that drains provide no clear advantage at total hip arthroplasty, represent an additional cost, and expose patients to a higher risk of transfusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1316 - 1320
1 Oct 2006
Azodi OS Bellocco R Eriksson K Adami J

We carried out a retrospective cohort study of 3309 patients undergoing primary total hip replacement to examine the impact of tobacco use and body mass index on the length of stay in hospital and the risk of short term post-operative complications.

Heavy tobacco use was associated with an increased risk of systemic post-operative complications (p = 0.004). Previous and current smokers had a 43% and 56% increased risk of systemic complications, respectively, when compared with non-smokers. In heavy smokers, the risk increased by 121%. A high body mass index was significantly associated with an increased mean length of stay in hospital of between 4.7% and 7%. The risk of systemic complications was increased by 58% in the obese. Smoking and body mass index were not significantly related to the development of local complications.

Greater efforts should be taken to reduce the impact of preventable life style factors, such as smoking and high body mass index, on the post-operative course of total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1293 - 1298
1 Oct 2006
Allami MK Fender D Khaw FM Sandher DR Esler C Harper WM Gregg PJ

Using the Trent regional arthroplasty register, we analysed the survival at ten years of 1198 consecutive Charnley total hip replacements carried out across a single health region of the United Kingdom in 1990. At ten years, information regarding outcome was available for 1001 hips (83.6%). The crude revision rate was 6.2% (62 of 1001) and the cumulative survival rate with revision of the components as an end-point was 93.1%. At five years, a review of this series of patients identified gross radiological failure in 25 total hip replacements which had previously been unrecognised. At ten years the outcome was known for 18 of these 25 patients (72%), of whom 13 had not undergone revision.

This is the first study to assess the survival at ten years for the primary Charnley total hip replacement performed in a broad cross-section of hospitals in the United Kingdom, as opposed to specialist centres. Our results highlight the importance of the arthroplasty register in identifying the long-term outcome of hip prostheses.