header advert
Results 641 - 660 of 4011
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score. Results. At final follow-up, the knee was unstable in 9/18 patients (50%) in the osteoarticular allograft group and 2/15 patients (13%) in the rAPC group (p = 0.026). The median range of motion (ROM) of the knee was 117° (IQR 115° to 120°) in the osteoarticular allograft group and 100° (IQR 95° to 105°) in the rAPC group (p < 0.001). The median MSTS score was 25 (IQR 23 to 26) in the osteoarticular allograft group and 28 (IQR 26 to 29) in the rAPC group (p = 0.007). Osteoarthritic change was detected in 11/18 patients (61%) in the osteoarticular allograft group and in 4/15 (26%) patients in the rAPC group (p = 0.048). Conclusion. In our series, a resurfaced allograft-prosthesis composite provided better knee stability and function, with a lower rate of osteoarthritis; an osteoarticular allograft was associated with better knee ROM. Cite this article: Bone Joint J 2022;104-B(10):1174–1179


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 935 - 942
1 Jul 2009
Hu S Zhang Z Hua Y Li J Cai Z

We performed a meta-analysis to evaluate the relative efficacy of regional and general anaesthesia in patients undergoing total hip or knee replacement. A comprehensive search for relevant studies was performed in PubMed (1966 to April 2008), EMBASE (1969 to April 2008) and the Cochrane Library. Only randomised studies comparing regional and general anaesthesia for total hip or knee replacement were included.

We identified 21 independent, randomised clinical trials. A random-effects model was used to calculate all effect sizes. Pooled results from these trials showed that regional anaesthesia reduces the operating time (odds ratio (OR) −0.19; 95% confidence interval (CI) −0.33 to −0.05), the need for transfusion (OR 0.45; 95% CI 0.22 to 0.94) and the incidence of thromboembolic disease (deep-vein thrombosis OR 0.45, 95% CI 0.24 to 0.84; pulmonary embolism OR 0.46, 95% CI 0.29 to 0.80).

Regional anaesthesia therefore seems to improve the outcome of patients undergoing total hip or knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1026 - 1026
1 Jul 2005
Ross A


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 648 - 655
1 May 2012
Jolles BM Grzesiak A Eudier A Dejnabadi H Voracek C Pichonnaz C Aminian K Martin E

This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years’ follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years).

Improvements in most gait parameters at five years’ follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 622 - 622
1 May 2003
Hunt D


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 309 - 309
1 Mar 2003
UNITT L


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1100 - 1102
1 Nov 2000
Pinskerova V Maquet P Freeman MAR


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 474 - 480
1 May 2023
Inclan PM Brophy RH

Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral extra-articular augmentation, and/or osteotomy. Although revision ACLr reliably restores knee stability and function, clinical outcomes and reoperation rates are worse than for primary ACLr. Cite this article: Bone Joint J 2023;105-B(5):474–480


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 534 - 534
1 May 1989
Rae P Noble J


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 89 - 93
1 Jan 1988
Kershaw C Themen A

The results of 132 Attenborough total knee replacements after a follow-up period of from four to 10 years are presented. Long-term relief of pain and improvement in stability and walking distance were maintained in over two-thirds. The cumulative survivorship with the prosthesis in situ, little or no pain and no radiological loosening was 65% at six years. Problems with wound healing were common, and there was a complication rate of 20% in primary replacements, including a deep-infection rate of 3.5%. Almost 20% of the prostheses needed revision because of aseptic loosening, and there is evidence of radiological and clinical loosening in a further 7.5%.


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 334 - 341
1 May 1968
Trickey EL

1. Seventeen cases of knee injury are described in which the predominant lesion was rupture of the posterior cruciate ligament. Seven were treated conservatively and ten by surgical repair.

2. Most cases occurred in motor cyclists.

3. The extent of the rupture should be determined by examination under anaesthesia.

4. Early surgical repair is indicated for complete rupture.

5. An effective method of repair is described.


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 4 | Pages 744 - 745
1 Nov 1964
Chesterman PJ


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 539 - 541
1 Aug 1964
Boucher HH

1. Strain or rupture of the anterior marginal attachments of the meniscus was observed in approximately 10 per cent of a group of patients operated upon for internal derangement.

2. In about half of these a tear of the body of the meniscus was found and it is probable that this tear may have been the cause of the symptoms. In the remainder no injury to the body of the meniscus was found.

3. Recognition may be difficult and delay in diagnosis may be the cause of degenerative joint changes.

4. The condition should be looked for at operation when the meniscus appears to be intact or when the only lesion appears to be an area of chondromalacia on the weight-bearing surface of the femoral condyle.


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 4 | Pages 683 - 688
1 Nov 1948
Last RJ


Bone & Joint Research
Vol. 2, Issue 1 | Pages 1 - 8
1 Jan 2013
Costa AJ Lustig S Scholes CJ Balestro J Fatima M Parker DA

Objectives

There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design.

Methods

A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 911 - 916
1 Jul 2013
Small SR Ritter MA Merchun JG Davis KE Rogge RD

Stress shielding resulting in diminished bone density following total knee replacement (TKR) may increase the risk of migration and loosening of the prosthesis. This retrospective study was designed to quantify the effects of the method of fixation on peri-prosthetic tibial bone density beneath cemented and uncemented tibial components of similar design and with similar long-term survival rates. Standard radiographs taken between two months and 15 years post-operatively were digitised from a matched group of TKRs using cemented (n = 67) and uncemented (n = 67) AGC tibial prostheses. Digital radiograph densitometry was used to quantify changes in bone density over time. Age, length of follow-up, gender, body mass index and alignment each significantly influenced the long-term pattern of peri-prosthetic bone density. Similar long-term changes in density irrespective of the method of fixation correlated well with the high rate of survival of this TKR at 20 years, and suggest that cemented and uncemented fixation are both equally viable.

Cite this article: Bone Joint J 2013;95-B:911–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 463 - 464
1 Apr 2003
MENCHE DS


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 772 - 774
1 Jul 2001
GRELSAMER RP


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 775 - 775
1 Jul 2000
PECKETT WRC BUTLER-MANUEL A