Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.Aims
Materials and Methods
We evaluated the accuracy of six
Our aims were to describe the distribution of α-smooth muscle actin (SMA)-containing cells in Dupuytren’s tissue in vivo and to determine the effects of selected agents in regulating the expression of SMA in Dupuytren’s cells in vitro. In selected hypercellular zones of Dupuytren’s nodules up to 40% of the cells contained SMA, as shown by immunohistochemistry. A lower percentage (20%) of SMA-containing cells was found in regions of lower cellularity. A notable finding was that treatment in vitro of Dupuytren’s cells with platelet-derived growth factor significantly reduced the content of SMA. Cells from the same patients showed a significant increase in expression of SMA in response to treatment with transforming growth factor, which confirmed recent findings. In addition, interferon-γ, which has been previously used as a treatment for Dupuytren’s disease in a
In a prospective randomised
We carried out a randomised, prospective, multicentre
Electromyographic and
Our objectives were to establish the envelope of passive movement and to demonstrate the kinematic behaviour of the knee during standard
The proximal femoral nail (PFN) is a recently introduced intramedullary system, designed to improve treatment of unstable trochanteric fractures of the hip. In a multicentre prospective
The integrity of the periosteum and the interosseous membrane determine the stability of fractures of the distal ulna; this is indicated by the initial displacement. In fractures displaced by less than 50% the periosteum and interosseous membranes are largely intact; these fractures are stable and require only below-elbow immobilisation for protection and relief of pain. In fractures displaced by more than 50% the membranes are disrupted; these fractures are unstable and require above-elbow immobilisation for stability. As most fractures are displaced by less than 50%, immobilisation of the elbow, which significantly increases morbidity, is usually unnecessary. I report the results of a cadaveric study on the pathomechanics of fractures of the distal ulna, and of a prospective
We sought to quantify agreement by different assessors of the AO classification for distal fractures of the radius. Thirty radiographs of acute distal radial fractures were evaluated by 36 assessors of varying clinical experience. Our findings suggest that AO ‘type’ and the presence or absence of articular displacement are measured with high consistency when classification of distal radial fractures is undertaken by experienced observers. Assessors at all experience levels had difficulty agreeing on AO ‘group’ and especially AO ‘subgroup’. To categorise distal radial fractures according to joint displacement and AO type is simple and reproducible. Our study examined only whether distal radial fractures could be consistently classified according to the AO system. Validation of the classification as a predictor of outcome will require a prospective
In controlled
A prospective randomised
A
To assist surgeons to select a total hip replacement (THR) we present comparative information on all such implants on the market in the UK. We identified 62 different primary THRs, manufactured by 19 companies; half had been introduced in the last five years, and only 30% have any results published in peer-reviewed journals. The prices range from 250 pounds to 2000 pounds, and the two cheapest implants have the longest reported follow-up. The number of THR implants available in the UK, and presumably the rest of the world, is rapidly increasing, but there is little or no scientific evidence that the newer, more expensive, implants are better than established designs. Some will undoubtedly be worse. We believe that this situation is unsatisfactory and make recommendations for improvement, in particular that preference be given to implants with good results in published peer-reviewed long-term
Cancer-induced bone diseases are often associated with increased bone resorption and pathological fractures. In recent years, osteoprotective agents such as bisphosphonates have been studied extensively and have been shown to inhibit cancer-related bone resorption in experimental and
We compared two cementless femoral components, the 'isoelastic' Butel stem and the more rigid PCA design, in a randomised, prospective study of 56 patients with a mean follow-up of 4 years (2 to 5). Patients were matched in 28 pairs, and one of each pair was treated with each femoral component. The isoelastic stem gave fewer signs of stress shielding radiologically, but both the Harris hip score and the visual analogue pain scale showed significantly inferior results at the two-year and three-year follow-up. The overall failure rates for the femoral components were 43% for the Butel and 11% for the PCA. These results contrast with those of earlier experimental and
Discitis after discography is due to bacterial penetration into the intervertebral disc by a contaminated needle and has an incidence of 1% to 4%. We have examined the prophylactic role of cephazolin administered at the time of discography. An experimental study in sheep using radiographic contrast containing Staphylococcus epidermidis showed that either adding the antibiotic to the intradiscal suspension or giving it intravenously 30 minutes before intradiscal inoculation of bacteria prevented any radiographic, macroscopic or histological signs of discitis; all the intervertebral disc cultures were negative. In a prospective
A control system for a multifunctional hand prosthesis, which requires a minimum of training for the amputee, has been developed. The great advantage of the pattern recognition technique in making it possible to control as many as six prosthetic movements has prompted this study. The development of a complete miniaturised system has allowed a
A multi-centre