Advertisement for orthosearch.org.uk
Results 621 - 640 of 1403
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 449 - 451
1 May 1999
Magyar G Toksvig-Larsen S Lindstrand A

We studied the complications after open-wedge osteotomy by hemicallotasis in 308 consecutive patients, most of whom had osteoarthritis of the knee. The participating surgeons, who worked at 17 hospitals, used their discretion in selecting patients, operating techniques and external fixators. The general complications included 11 cases of deep-vein thrombosis (4%), six of nonunion (2%) and one of septic arthritis of the knee. There were technical complications in 13 patients (4%). In 157 patients (51%) pin-site infections were recorded; of these, 96% were minor and responded to wound toilet and antibiotic treatment. A total of 18 revision procedures was carried out


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 337 - 343
1 Apr 2004
Graham NM Stockley I

Between April 1992 and November 1998 we used 34 massive proximal femoral allografts for femoral reconstruction at revision hip arthroplasty. Seven patients have died and two have been lost to follow-up. There were thus 25 grafts in 24 patients for review. The mean follow-up was 53 months (16 to 101). By the time of the review two patients had undergone a further revision for failure of the allograft. Another had required secondary plating and grafting at the graft-host junction for symptomatic nonunion. One had recurrence of deep sepsis and was being managed conservatively. Trochanteric union was considered to have occurred radiologically in 16 of the 25 grafts and union at the host-graft junction in 20. Resorption of the allograft was significant in only two hips. We recommend this technique in cases in which femoral bone loss has been catastrophic


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 359 - 365
1 Apr 2004
Sakano S Hasegawa Y Torii Y Kawasaki M Ishiguro N

We reviewed the outcome of curved intertrochanteric varus osteotomy in the treatment of osteonecrosis of the femoral head in 20 hips. A mean varus angulation of 31° was obtained by the osteotomy. The ratio of intact area on the weight-bearing portion increased from 19% to 61%. The mean elevation and lateral displacement of the greater trochanter were 1.2 cm and 0.5 cm, respectively. These changes in the position of the greater trochanter were very small when compared with those after conventional varus wedge osteotomy. Nonunion or delayed union was not observed. Quantitative analyses showed aggressive bone remodelling in the medial intertrochanteric region. Eighteen hips survived without collapse after a mean follow-up of 48 months. We conclude that curved varus osteotomy can be used to preserve the hip joint in patients with osteonecrosis of the femoral head


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1408 - 1415
1 Nov 2019
Hull PD Chou DTS Lewis S Carrothers AD Queally JM Allison A Barton G Costa ML

Aims

The aim of this study was to assess the feasibility of conducting a full-scale, appropriately powered, randomized controlled trial (RCT) comparing internal fracture fixation and distal femoral replacement (DFR) for distal femoral fractures in older patients.

Patients and Methods

Seven centres recruited patients into the study. Patients were eligible if they were greater than 65 years of age with a distal femoral fracture, and if the surgeon felt that they were suitable for either form of treatment. Outcome measures included the patients’ willingness to participate, clinicians’ willingness to recruit, rates of loss to follow-up, the ability to capture data, estimates of standard deviation to inform the sample size calculation, and the main determinants of cost. The primary clinical outcome measure was the EuroQol five-dimensional index (EQ-5D) at six months following injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 416 - 421
1 Aug 1982
Ryan M Taylor T

Twenty-three adults with fractures of the odontoid process are reviewed. Te possible reasons for the high rate of non-union in reported series are considered: these include the type of fracture, its displacement, the presence of a gap at the fracture site, imperfect reduction and inadequate immobilisation. Type 2 fractures (at the base of the odontoid process) are the commonest and also the most liable to nonunion. In their treatment, reduction is important; as seen in the lateral radiograph at least two-thirds of the fracture surfaces should be in contact. Skull traction is not advised and halo-cast fixation is the treatment of choice; with this method 87.5 per cent of recent odontoid fractures united


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 411 - 418
1 Apr 2003
Ziran BH Smith WR Towers J Morgan SJ

Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of iliosacral screws is a safe, feasible, and cost-effective alternative to radiologically-guided placement in the operating theatre in selected patients


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 178 - 180
1 Mar 1989
Rehnberg L Olerud C

We describe a method of internal fixation for femoral neck fractures which has been newly developed to reduce the frequency of early complications. Two cannulated screws are inserted in the axis of the femoral neck to reach into the subchondral bone of the femoral head. The screws are inserted over guide pins and the tip of the screw is self-tapping and designed to provide good anchorage in the femoral head. We used this method in 44 consecutive patients in a prospective study with no exclusions, followed for a minimum of 24 months. All fractures healed within 12 months, and there were no cases of early loosening or nonunion. In four cases, late segmental collapse had developed during the mean follow-up period of 30 months


Bone & Joint 360
Vol. 8, Issue 4 | Pages 46 - 47
1 Aug 2019
Das A


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 566 - 571
1 Jul 1993
Murray D Kambouroglou G Kenwright J

One-stage femoral lengthening is thought to have an unacceptably high complication rate and is not widely practised. We reviewed 17 patients after one-stage lengthening for femoral shortening with associated angular or rotational deformities. Minimal dissection of the bone ends was undertaken. The mean length gain was 4 cm (2 to 7), and the average time to union was 6 months (3 to 10). There were no neurovascular complications. Four patients had delayed or nonunion, but union was achieved after bone grafting. We conclude that with minimal dissection, and with iliac crest cancellous bone grafting, one-stage leg lengthening for correction of deformity and leg-length inequality of up to 7 cm, in selected patients, can be effected safely with a relatively short rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 620 - 623
1 Jul 1998
Mohammed NSE

A new technique of shoulder fusion is presented using a posterior approach. After removal of the articular cartilage, a Rush pin is introduced from the spine of the scapula, through the glenoid into the medullary canal of the humerus. This is supplemented by tension-band wiring from the acromion to the neck of the humerus and a muscle pedicle graft attached to the acromion. A shoulder spica is applied for four to six weeks. Four patients with injuries to the upper brachial plexus and 14 with paralysis of the upper arm due to anterior poliomyelitis have been followed for three years. One of the 18 patients developed nonunion; she had removed her own cast prematurely. This method of fixation provides high shear resistance and low axial stiffness without deforming plastically. It does not affect bone growth in young patients, is effective in patients with osteoporosis, and gives a high rate of union


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 452 - 455
1 May 1998
Stoney J O’Brien J Wilde P

We treated 22 patients with type-two odontoid fractures in halothoracic vests for six to eight weeks followed by a Philadelphia collar for four weeks. Eighteen patients were reviewed by questionnaire and radiography at a mean of 40 months after injury. We assessed union, fracture position, the degree of permanent pain and stiffness, satisfaction with the treatment and the outcome. The overall union rate was 82%. Posterior malunion with residual posterior displacement or angulation was associated with a higher incidence of persisting pain. The position at union did not correlate with the residual cervical stiffness. Fractures failed to unite in four patients (18%) none of whom had late neurological sequelae, although they had more late pain. There were associations between the development of nonunion and an extension-type injury, age over 65 years and delay in diagnosis


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 904 - 913
1 Nov 1993
Hernigou P Delepine G Goutallier D Julieron A

From 1984 to 1988 we implanted 127 massive allografts irradiated with a dose of 25,000 grays. These were reviewed at a minimum follow-up of three years to determine the effect of irradiation on infection, the complications and the functional result. No bacteriological infection was seen in the 44 patients who had allografts for revision of joint arthroplasty or for a tumour with no adjuvant therapy. For the 83 patients who also had chemotherapy or radiotherapy or both for a bone tumour, the rate of infection was 13%. The major mechanical complications were nonunion in seven grafts (5.5%) and fracture in eight (6%). These rates do not differ greatly from those reported for non-irradiated grafts. Our results suggest that irradiation, which remains the most convenient and acceptable method of sterilisation, does not jeopardize the clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 106 - 108
1 Jan 1998
Ngarmukos C Parkpian V Patradul A

We treated 110 fractures of the middle third of the clavicle in 108 patients aged between 14 and 66 years, by fixation with 2 mm Kirschner wires. The wire was introduced, using an air drill and a telescoping guide, from the medial into the lateral fragment. The medial end of the wire which perforated the anterior cortex of the medial fragment was bent backwards to prevent migration into the lung or mediastinum. In cases of nonunion and acute fracture in which a bone gap was present, bone graft was laid around the fracture site after internal fixation. All the fractures united. No wires broke but in three patients one migrated before union was achieved. Twenty-one patients failed to return for removal of the wire; nine of them had radiological evidence of union before they were lost to follow-up


Bone & Joint Research
Vol. 8, Issue 10 | Pages 472 - 480
1 Oct 2019
Hjorthaug GA Søreide E Nordsletten L Madsen JE Reinholt FP Niratisairak S Dimmen S

Objectives

Experimental studies indicate that non-steroidal anti-inflammatory drugs (NSAIDs) may have negative effects on fracture healing. This study aimed to assess the effect of immediate and delayed short-term administration of clinically relevant parecoxib doses and timing on fracture healing using an established animal fracture model.

Methods

A standardized closed tibia shaft fracture was induced and stabilized by reamed intramedullary nailing in 66 Wistar rats. A ‘parecoxib immediate’ (Pi) group received parecoxib (3.2 mg/kg bodyweight twice per day) on days 0, 1, and 2. A ‘parecoxib delayed’ (Pd) group received the same dose of parecoxib on days 3, 4, and 5. A control group received saline only. Fracture healing was evaluated by biomechanical tests, histomorphometry, and dual-energy x-ray absorptiometry (DXA) at four weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 173 - 177
1 Mar 1989
Rehnberg L Olerud C

We measured the stability of fixation in femoral neck fractures treated with von Bahr screws, investigated the influence of impaction and correlated peroperative stability with the clinical results. Stability was measured at operation using a metal probe fitted with strain gauges. Its tip was anchored in the subchondral bone of the femoral head and its lateral end was fixed in the lateral femoral cortex. The shearing force produced by longitudinal compression applied to the foot of the operated leg was recorded. The results in 41 consecutive patients all followed for 30 months, showed that fractures with early loosening or nonunion had all had significantly poorer stability than the fractures that had healed. Impaction improved stability in only 23 out of the 41 fractures; in the others stability had deteriorated or was unchanged


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 659 - 668
1 Jul 2004
Rammelt S Grass R Zawadski T Biewener A Zwipp H

Subtalar distraction bone-block arthrodesis for malunited calcaneal fractures was performed in 31 patients (26 men, five women), with a mean age of 38.5 years. The mean time from injury to arthrodesis was 36 months. There were no cases of nonunion. One patient had an early dislocation of the bone block requiring a repeat arthrodesis, and one had a soft-tissue infection. The mean AOFAS hindfoot score improved significantly from 23.5 before operation to 73.2 at a mean follow-up of 33 months (p > 0.001). Compared with the unaffected side, the talocalcaneal height was corrected by 61.8%, the talus-first metatarsal axis by 46.5%, the talar declination angle by 38.5% and the talocalcaneal angle by 35.4%. Dynamic pedobarography revealed a return to normal of the pressure distribution during roll-over and a more energetic gait. The distribution of local transfer of load correlated well with the AOFAS score. The amount of correction of the heel height correlated with a normal pattern of pressure transfer on the heel (p < 0.05)


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 403 - 406
1 Apr 2020
Trompeter A


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 596 - 601
1 Jul 1994
Marks D Isbister E Porter K

We report 33 cases of femoral supracondylar fracture in elderly or debilitated patients treated by Zickel supracondylar nails. Most of the patients were female and their mean age was 79 years. All had concurrent medical problems and only nine could walk unaided. The operating time averaged one hour and mean blood loss was 100 ml. Postoperative management was by mobilisation in a cast brace or plaster. Six patients died before fracture union; all the others achieved union at an average of 12 weeks. The results were excellent in terms of pain relief, movement and function; there were no infections or nonunions. The locking screws backed out or broke in 26% but this did not prejudice the outcome. Use of the Zickel system is recommended for this group of frail patients


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 852 - 859
1 Jul 2019
Reigstad O Holm-Glad T Korslund J Grimsgaard C Thorkildsen R Røkkum M

Aims

Plate and screw fixation has been the standard treatment for painful conditions of the wrist in non-rheumatoid patients in recent decades. We investigated the complications, re-operations, and final outcome in a consecutive series of patients who underwent wrist arthrodesis for non-inflammatory arthritis.

Patients and Methods

A total of 76 patients, including 53 men and 23 women, with a mean age of 50 years (21 to 79) underwent wrist arthrodesis. Complications and re-operations were recorded. At a mean follow-up of 11 years (2 to 18), 63 patients completed questionnaires, and 57 attended for clinical and radiological assessment.