Advertisement for orthosearch.org.uk
Results 581 - 600 of 1295
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 748 - 754
1 Jul 2000
Case CP Langkamer VG Lock RJ Perry MJ Palmer MR Kemp AJ

We compared the peripheral blood and periprosthetic tissues of 53 patients at revision arthroplasty with those of 30 patients at primary arthroplasty to determine whether there is a systemic difference in lymphocytes in patients with worn hip implants. The absolute number and relative proportion of lymphocytes bearing CD2, CD3, CD4, CD8, CD16, CD19, HLA-DR, kappa and lambda antigens were compared with the levels of IL-1β, IL-6 and PGE. 2. in the pseudosynovial membrane as well as with a semiquantitative estimate of metal and polyethylene particles, necrosis and chronic inflammation and the total concentration of metals within the periprosthetic tissues. There was a significant increase in the relative proportion of CD2-positive T-cells and CD16-positive natural killer cells in the peripheral blood at revision arthroplasty compared with primary arthroplasty and an increased proportion of CD8-positive T-cells and a decreased ratio of CD4 to CD8 (helper inducer/suppressor cytotoxic cells). Three control patients, who went on to have revision surgery, had values at primary arthroplasty which were similar to those of patients at the time of revision surgery. These differences did not correlate with the local concentration of metal, plastic or cement or inflammatory response or the type of prosthesis. An inverse correlation was noted between the necrosis in the periprosthetic tissue and both the local production of IL-6 and the absolute numbers of T-cells in peripheral blood. We conclude that there may be several cell-mediated systemic immune responses to aseptic loosening, at least one of which may be directly related to events in the periprosthetic tissues. We cannot exclude the possibility that the changes in the proportion of CD8-positive cells reflected a predisposition, rather than a reaction, to loosening of the implant


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 4 | Pages 702 - 710
1 Nov 1959
Laurenson RD

What is the present position? There is no doubt that the meaning of Kleinberg and Lieberman has been misconceived. With the passing of years their cautious conclusion concerning the acetabular index has been transformed into a firm conviction. Even so, it is apparent from the literature that the use of the acetabular index is a matter of controversy, and that, to a lesser degree, the normal values of the index are a matter of debate. It is concluded that the measurement is not an absolute index of a predisposition to congenital dislocation of the hip and cannot be divorced from other radiological signs. Nevertheless, so long as there is a feeling of uncertainty about the most reliable early signs of congenital dislocation of the hip, it would be folly to ignore a high acetabular index, especially in an infant over six months of age. It seems that to radiograph every infant at birth is not justified. The radiological signs at birth are not only unreliable because of problems of technique, but also equivocal because of the small size of the structures and the fact that they consist largely of cartilage. Until the radiographic technique is standardised it would be advisable to continue to regard 30 degrees as the upper limit of normal for the acetabular index in the newborn. To make recommendations concerning treatment is beyond the scope of this paper. Nevertheless it is worth stating that the presence of a high index alone is not necessarily regarded as an indication for immediate treatment. But an infant found to have a high acetabular index should be kept under close observation and should be thoroughly examined at regular intervals before the beginning of full weight bearing


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1002 - 1009
1 Aug 2018
Westerman RW Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Aims

The aim of this study was to report the initial results of the Exeter V40 stem, which became available in 2000.

Patients and Methods

A total of 540 total hip arthroplasties (THAs) were performed in our unit using this stem between December 2000 and May 2002. Our routine protocol is to review patients postoperatively and at one, five, and ten years following surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 144 - 150
1 Jan 1998
Hunziker EB Kapfinger E Müller ME

Lesions within the articular cartilage layer of synovial joints do not heal spontaneously. Some repair cells may appear, but their failure to become established may be related to problems of adhesion to proteoglycan-rich surfaces. We therefore investigated whether controlled enzymatic degradation of surface proteoglycan molecules to a depth of about 1 μm, using chondroitinase ABC, would improve coverage by repair cells. We created superficial lesions (1.0 × 0.2 × 5 mm) in the articular cartilage of mature rabbit knees and treated the surfaces with 1 U/ml of chondroitinase ABC for four minutes. The defects were studied by histomorphometry and electron microscopy at one, three and six months. At one month, untreated lesions were covered to a mean extent of 28% by repair cells; this was enhanced to a mean of 53% after enzyme treatment. By three months, the mean coverage of both control and chondroitinase-ABC-treated defects had diminished dramatically to 0.2% and 13%, respectively, but at six months both untreated and treated lesions had a similar coverage of about 30%, not significantly different from that achieved in untreated knees at one month. These findings suggest that, with time, chondrocytes near the surface of the defect may compensate for the loss of proteoglycans produced by enzyme treatment, thereby restoring the inhibitory properties of the matrix as regards cell adhesion. This supposition was confirmed by electron microscopy. Our results have an important bearing on attempts made to induce healing responses by transplanting chondrogenic cells or by applying growth factors


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 925 - 929
1 Jul 2018
Abdel MP Tibbo ME Stuart MJ Trousdale RT Hanssen AD Pagnano MW

Aims

It has been suggested that mobile-bearing total knee arthroplasty (TKA) might lead to better outcomes by accommodating some femorotibial rotational mismatch, thereby reducing contact stresses and polyethylene wear. The aim of this study was to determine whether there is a difference between fixed- and mobile-bearing versions of a contemporary TKA with respect to durability, range of movement (ROM) and function, ten years postoperatively.

Patients and Methods

A total of 240 patients who were enrolled in this randomized controlled trial (RCT) underwent a primary cemented TKA with one of three tibial components (all-polyethylene fixed-bearing, modular metal-backed fixed-bearing and mobile-bearing). Patients were reviewed at a median follow-up of ten years (IQR 9.2 to 10.4).


Bone & Joint 360
Vol. 6, Issue 4 | Pages 16 - 18
1 Aug 2017


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 845 - 852
1 Jul 2018
Langston J Pierrepont J Gu Y Shimmin A

Aims

It is important to consider sagittal pelvic rotation when introducing the acetabular component at total hip arthroplasty (THA). The purpose of this study was to identify patients who are at risk of unfavourable pelvic mobility, which could result in poor outcomes after THA.

Patients and Methods

A consecutive series of 4042 patients undergoing THA had lateral functional radiographs and a low-dose CT scan to measure supine pelvic tilt, pelvic incidence, standing pelvic tilt, flexed-seated pelvic tilt, standing lumbar lordotic angle, flexed-seated lumbar lordotic angle, and lumbar flexion. Changes in pelvic tilt from supine-to-standing positions and supine-to-flexed-seated positions were determined. A change in pelvic tilt of 13° between positions was deemed unfavourable as it alters functional anteversion by 10° and effectively places the acetabular component outside the safe zone of orientation.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 2 | Pages 304 - 322
1 May 1954
Harris RI Macnab I

One of the interesting aspects of spinal pathology having an important bearing on the treatment of backache is that the spine acts as an integrated whole and that damage sustained by one part frequently injures other structures in the spinal column. Thus disc degeneration may be associated with an extrusion of nuclear material; it may initiate degenerative changes in the posterior joints; it may predispose to tears of the posterior spinal ligaments; or it may give rise eventually to all of these lesions, any one of which may produce backache with or without sciatica. The sciatica may be referred pain or may be produced by nerve root pressure. Nerve root pressure in such instances is commonly due to an extrusion of nuclear material, but it may also be due to pressure on the nerve root within the foramen by a "squashed" disc or by a subluxated posterior joint. Radiographs are of great value in the diagnosis of disc degeneration and they are of greater value in the assessment of the secondary effects that have taken place. With the use of bending films evidence of early degenerative changes may be obtained, tears of the supraspinous ligament can be detected, and abnormal movements of the posterior joints can be seen. Careful study of the antero-posterior and lateral projections will reveal evidence of subluxation of the posterior joints, chip fractures and degenerative arthritis in the zygapophysial articulations, and will clearly demonstrate overriding of the facets. The investigation of subjective phenomena, such as backache, is fraught with many difficulties and it must be preceded by an investigation of the anatomy of the part and the anatomical variations, the normal and abnormal physiology and the pathological lesions that occur. Many of these changes of course may have no clinical significance, but it is only when armed with the knowledge of what may occur that we can tackle the problem of low back pain on a logical basis


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 4 | Pages 627 - 642
1 Nov 1953
Lloyd-Roberts GC

1. The synovial membrane and capsule in osteoarthritis of the hip have been studied in twenty-five cases. Dissections have been made on fresh cadavers to establish the normal structure and function of these tissues at different ages. 2. Fragments of bone and cartilage were found beneath the synovial surface in twenty-three cases of the twenty-five cases of osteoarthritis. 3. The source of these fragments is the degenerate articular surfaces. 4. The fibrosis of the synovial membrane and capsule follows the synovial hyperplasia which accompanies the phagocytosis of these fragments. 5. A similar histological picture has been produced by injecting fragmented cartilage into the knee joints of rabbits. The injected fragments are found beneath the surface, and synovial hyperplasia is followed by subsynovial fibrosis. 6. The greatest amount of this joint debris is found in the lowest part of the joint cavity. 7. The joint capsule is particularly sensitive to traction. 8. All parts of the capsule are tight in extension, which is the weight-bearing position. 9. Fibrotic shortening of the capsule in the lowest part of the joint cavity explains many of the symptoms and signs of the disease: pain is caused by an attempt to stretch the capsule; muscle spasm occurs in the muscles supplied by the sensory nerves of this part of the capsule; extension, medial rotation and abduction, which tighten this area, are lost first; progressive shortening causes deformity in the opposite direction, namely flexion, lateral rotation and adduction; the loss of extension causes a more rapid wearing of articular cartilage on weight bearing; subperiosteal new bone is formed on the under-surface of the neck of the femur. 10. The symptomatology is discussed


Bone & Joint 360
Vol. 6, Issue 5 | Pages 8 - 12
1 Oct 2017


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1033 - 1042
1 Aug 2018
Kayani B Konan S Pietrzak JRT Huq SS Tahmassebi J Haddad FS

Aims

The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA.

Patients and Methods

This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (sd 6.8) vs 64.1 years (sd 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (sd 2.7) vs 28.1 kg.m2 (sd 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications.


Bone & Joint Research
Vol. 7, Issue 7 | Pages 440 - 446
1 Jul 2018
Woods AK Broomfield J Monk P Vollrath F Glyn-Jones S

Objectives

The aim of this study was to investigate the structural integrity of torn and non-torn human acetabular labral tissue.

Methods

A total of 47 human labral specimens were obtained from a biobank. These included 22 torn specimens and 25 control specimens from patients undergoing total hip arthroplasty with macroscopically normal labra. The specimens underwent dynamic shear analysis using a rheometer to measure storage modulus, as an indicator of structural integrity.


Bone & Joint Research
Vol. 7, Issue 8 | Pages 524 - 538
1 Aug 2018
Zhao S Arnold M Ma S Abel RL Cobb JP Hansen U Boughton O

Objectives

The ability to determine human bone stiffness is of clinical relevance in many fields, including bone quality assessment and orthopaedic prosthesis design. Stiffness can be measured using compression testing, an experimental technique commonly used to test bone specimens in vitro. This systematic review aims to determine how best to perform compression testing of human bone.

Methods

A keyword search of all English language articles up until December 2017 of compression testing of bone was undertaken in Medline, Embase, PubMed, and Scopus databases. Studies using bulk tissue, animal tissue, whole bone, or testing techniques other than compression testing were excluded.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 741 - 748
1 Jun 2017
Lee YK Ha YC Yoo J Jo WL Kim K Koo KH

Aims

We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship.

Patients and Methods

Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 20 - 27
1 Jan 2018
Sabah SA Moon JC Jenkins-Jones S Morgan CL Currie CJ Wilkinson JM Porter M Captur G Henckel J Chaturvedi N Kay P Skinner JA Hart AH Manisty C

Aims

The aim of this study was to determine whether patients with metal-on-metal (MoM) arthroplasties of the hip have an increased risk of cardiac failure compared with those with alternative types of arthroplasties (non-MoM).

Patients and Methods

A linkage study between the National Joint Registry, Hospital Episodes Statistics and records of the Office for National Statistics on deaths was undertaken. Patients who underwent elective total hip arthroplasty between January 2003 and December 2014 with no past history of cardiac failure were included and stratified as having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty. The primary outcome measure was the time to an admission to hospital for cardiac failure or death. Analysis was carried out using data from all patients and from those matched by propensity score.


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 85 - 93
1 Jan 2018
Saleh A George J Faour M Klika AK Higuera CA

Objectives

The diagnosis of periprosthetic joint infection (PJI) is difficult and requires a battery of tests and clinical findings. The purpose of this review is to summarize all current evidence for common and new serum biomarkers utilized in the diagnosis of PJI.

Methods

We searched two literature databases, using terms that encompass all hip and knee arthroplasty procedures, as well as PJI and statistical terms reflecting diagnostic parameters. The findings are summarized as a narrative review.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 703 - 711
1 Jun 2018
Marson BA Deshmukh SR Grindlay DJC Scammell BE

Aims

The aim of this review was to evaluate the available literature and to calculate the pooled sensitivity and specificity for the different alpha-defensin test systems that may be used to diagnose prosthetic joint infection (PJI).

Materials and Methods

Studies using alpha-defensin or Synovasure (Zimmer Biomet, Warsaw, Indiana) to diagnose PJI were identified from systematic searches of electronic databases. The quality of the studies was evaluated using the Quality Assessment of Studies of Diagnostic Accuracy (QUADAS) tool. Meta-analysis was completed using a bivariate model.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 14 - 16
1 Jun 2017


Bone & Joint 360
Vol. 6, Issue 2 | Pages 10 - 13
1 Apr 2017