Advertisement for orthosearch.org.uk
Results 581 - 600 of 1356
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 307 - 309
1 Mar 1995
Went P Krismer M Frischhut B

We performed revision surgery for infected arthroplasty in 98 hips (96 patients). In 28 hips infection persisted. Of the remaining 70 hips, 61 (87%) were reviewed after a mean interval of 5.9 years (1 to 17). Infection occurred in 10% of these after three years and in 26% after ten years. The infection rate after initially successful revision for septic arthroplasty is higher than after revision for aseptic loosening and the risk of developing infection continues for many years


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 917 - 922
1 Jul 2013
Sabouret P Lavoie F Cloutier J

We report on the long-term results of 163 bicruciate-retaining Hermes 2C total knee replacements in 130 patients at a mean follow-up of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament had a partially degenerative appearance it was preserved as long as the knee had a normal anterior drawer and Lachman’s test pre-operatively. The description and surgical technique of this minimally constrained prosthesis were published in 1983 and the ten-year clinical results in 1999. A total of 12% of the knees (20 of 163) in this study were revised because of wear of the polyethylene tibial insert. Excellent stability was achieved and the incidence of aseptic component loosening was 4.3% (seven of 163). The survival rate using revision for any reason as the endpoint was 82% (95% confidence interval 76.2 to 88.0). Although this series included a relatively small number of replacements, it demonstrated that the anterior cruciate ligament, even when partially degenerated at the time of TKR, remained functional and provided adequate stability at a long-term follow-up. Cite this article: Bone Joint J 2013;95-B:917–22


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 391 - 395
1 May 1998
Schreurs BW Slooff TJJH Buma P Gardeniers JWM Huiskes R

We report a long-term review of 60 acetabular components revised using impacted, morsellised bone allografts and a cemented polyethylene cup. The acetabular defects were cavitary (37) or combined (23). Follow-up was for a mean 11.8 years (10 to 15). Further revision was needed in five hips, two for septic and three for aseptic loosening. The overall survival rate at 11.8 years was 90%; excluding the septic cases it was 94%. Acetabular reconstruction with impacted morsellised cancellous grafts and cement gives satisfactory long-term results


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1238 - 1246
1 Jul 2021
Hemmerling KJ Weitzler L Bauer TW Padgett DE Wright TM

Aims

Dual mobility implants in total hip arthroplasty are designed to increase the functional head size, thus decreasing the potential for dislocation. Modular dual mobility (MDM) implants incorporate a metal liner (e.g. cobalt-chromium alloy) in a metal shell (e.g. titanium alloy), raising concern for mechanically assisted crevice corrosion at the modular liner-shell connection. We sought to examine fretting and corrosion on MDM liners, to analyze the corrosion products, and to examine histologically the periprosthetic tissues.

Methods

A total of 60 retrieved liners were subjectively scored for fretting and corrosion. The corrosion products from the three most severely corroded implants were removed from the implant surface, imaged using scanning electron microscopy, and analyzed using Fourier-transform infrared spectroscopy.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 852 - 855
1 Aug 2002
Norton MR Vhadra RK Timperley AJ

We have found poor mid-term results in a multisurgeon series of 94 Johnson-Elloy (Accord) total knee replacements. A total of 27 knees (29%) has required revision, in 26 for aseptic loosening. Only 18 (19%) remain in situ, and these give poor function, are painful and most show radiological evidence of early failure. At 12 to 13 years the survival rate is 43% (confidence interval 29 to 57) with failure requiring revision as the endpoint. Proximal migration of the femoral component is associated with considerable loss of bone stock. We believe that all patients who have this implant should be recalled for regular review in order to anticipate this problem


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 805 - 806
1 May 2021
Magan AA Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 573 - 576
1 Jul 1998
Howie DW Middleton RG Costi K

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regularly and none was lost to follow-up. After a minimum follow-up of nine years, four matt but no polished stems had been revised for aseptic loosening. Polished stems subsided slightly within the cement mantle early, but did not loosen


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 631 - 635
1 Jul 2002
Norton MR Yarlagadda R Anderson GH

We report catastrophic early failure of a cemented total hip replacement comprising a modular femoral component with a Zirconia ceramic head and an acetabular component of cross-linked ultra-high molecular-weight polyethylene (Hylamer). Between 1995 and 1999 we implanted 29 hips in 26 patients with a mean age of 49.2 years. Survivorship analysis in this group revealed a failure rate of 67.6% at five years. All hips which failed did so because of aseptic loosening with progressive osteolysis or radiolucencies. We therefore recommend early and regular review of all patients with this combination of implants and early revision surgery in order to avoid massive bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 303 - 306
1 Mar 1995
Wyssa B Raut V Siney P Wroblewski B

We reviewed 54 patients at a mean follow-up of 4 years 4 months after rerevisions for failure of Charnley low-friction arthroplasty. Rerevision for aseptic loosening in 26 hips was satisfactory; there were no clinical failures and at the latest radiological assessment only one stem and three sockets showed signs of loosening. By contrast, nine of 20 multiple revisions for recurrent dislocation failed, as did five of eight multiple revisions for deep infection. There was radiological evidence of loosening in one stem and nine sockets in the former group and in three stems and five sockets in the latter


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 89 - 93
1 Jan 1988
Kershaw C Themen A

The results of 132 Attenborough total knee replacements after a follow-up period of from four to 10 years are presented. Long-term relief of pain and improvement in stability and walking distance were maintained in over two-thirds. The cumulative survivorship with the prosthesis in situ, little or no pain and no radiological loosening was 65% at six years. Problems with wound healing were common, and there was a complication rate of 20% in primary replacements, including a deep-infection rate of 3.5%. Almost 20% of the prostheses needed revision because of aseptic loosening, and there is evidence of radiological and clinical loosening in a further 7.5%


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 603 - 608
1 Jul 1997
Massoud SN Hunter JB Holdsworth BJ Wallace WA Juliusson R

We have studied aseptic loosening of the femoral component in 76 patients with primary total hip replacement using the Capital prosthesis. The mean follow-up was 26 months (10 to 37). Twelve femoral components (16%) were definitely and eight (10%) were possibly loose. They were characterised by a thin cement mantle (p < 0.001) and excessive residual cancellous bone in the proximomedial region (p < 0.01). We recommend that the cement mantle around the prosthesis should be 2 to 3 mm and that further long-term studies are needed to evaluate the wear properties of titanium-nitride-coated titanium femoral heads


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 375 - 377
1 Apr 2000
Inao S Matsuno T

We carried out primary cemented total hip arthroplasty (THA) on 25 hips in 21 patients with developmental dysplasia of the hip, using autogenous acetabular bone grafts. The socket was placed at the level of the true acetabulum and bone from the femoral neck was used as graft. Five hips were excluded, leaving 20 which were followed up for a mean of 12.9 years (10 to 18). The mean modified Merle d’Aubigné and Postel functional scores were 5.6 for pain, 4.3 for mobility and 4.2 for range of movement. Radiological examination showed aseptic loosening in three sockets but not in the stems. The bone grafts had united and showed no evidence of late failure


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1206 - 1214
1 Jul 2021
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A

Aims

We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty.

Methods

In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.


Bone & Joint 360
Vol. 10, Issue 3 | Pages 20 - 23
1 Jun 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 216 - 219
1 Mar 2002
Kim Y Kim J Oh S

We describe the results of total knee arthroplasty (TKA) undertaken for severe, neurosyphilitic Charcot arthropathy in ten patients (19 knees). A cemented condylar, constrained prosthesis was implanted in all but two knees. The mean follow-up was 5.2 years (5 to 6). The mean knee score before operation was 36.5 points (30 to 42) which improved to 76 points (58 to 90) after operation as judged by the Hospital for Special Surgery score. At final follow-up three knees (16%) had aseptic loosening which required salvage by an arthrodesis, six (31%) were functioning poorly and ten (53%) were satisfactory. We conclude that although Charcot arthropathy is not an absolute contraindication to total knee replacement, there is a high incidence of serious complications


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 388 - 395
1 Apr 2004
Sirveaux F Favard L Oudet D Huquet D Walch G Mole D

We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted. This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a massive tear of the cuff but should be reserved for elderly patients


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 338 - 346
1 Feb 2021
Khow YZ Liow MHL Lee M Chen JY Lo NN Yeo SJ

Aims

This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA.

Methods

Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 865 - 869
1 Aug 2002
Wicart P Mascard E Missenard G Dubousset J

Failure of massive knee endoprostheses implanted for malignant tumours of the distal femur in children presents a difficult problem. We present the results of rotationplasty undertaken under these circumstances in four boys. They had been treated initially at a mean age of 9.5 years for a stage-IIB malignant tumour of the distal femur by resection and implantation of a massive knee endoprosthesis. After a mean period of eight years and a mean of four operative procedures, there was failure of the endoprosthesis because of aseptic loosening in two and infection in two. Function was poor with a mean Musculoskeletal Tumor Society score of 7.5/30, and considerable associated psychological problems. At a mean follow-up of 4.5 years after rotationplasty there was excellent function with a mean score of 27.5/30 and resolution of the psychological problems


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1156 - 1161
1 Nov 2000
Rafiq M Worthington T Tebbs SE Treacy RBC Dias R Lambert PA Elliott TSJ

Coagulase-negative staphylococci produce an exocellular glycolipid antigen which has potential as a serological marker of infection in bone. The value of this newly detected antigen was investigated by enzyme-linked immunosorbent assay (ELISA) in 15 patients with culture-proven infection of prostheses caused by Gram-positive bacteria. The antigen was purified by gel-permeation chromatography from the culture supernatants of coagulase-negative staphylococci grown in a chemically defined medium. There were significant differences (p < 0.0001) between the serum IgG and IgM levels in patients with infection due to Gram-positive staphylococci and those of a control group of 32 patients with no infection. The ELISA test, which has potential for the diagnosis of infection, may be valuable in distinguishing between staphylococcal infection around prostheses and aseptic loosening


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1222 - 1230
1 Jul 2021
Slullitel PA Garcia-Barreiro GG Oñativia JI Zanotti G Comba F Piccaluga F Buttaro MA

Aims

We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty.

Methods

We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.