A successful outcome following treatment of nonunion requires the correct identification of all of the underlying cause(s) and addressing them appropriately. The aim of this study was to assess the distribution and frequency of causative factors in a consecutive cohort of nonunion patients in order to optimise the management strategy for individual patients presenting with nonunion. Causes of the nonunion were divided into four categories: mechanical; infection; dead bone with a gap; and host. Prospective and retrospective data of 100 consecutive patients who had undergone surgery for long bone fracture nonunion were analysed.Objectives
Methods
The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase.
Fractures of the tibial shaft are common injuries,
but there are no long-term outcome data in the era of increased surgical
management. The aim of this prospective study was to assess the
clinical and functional outcome of this injury at 12 to 22 years.
Secondary aims were to determine the short- and long-term mortality,
and if there were any predictors of clinical or functional outcome
or mortality. From a prospective trauma database of 1502 tibial
shaft fractures in 1474 consecutive adult patients, we identified
a cohort of 1431 tibial diaphyseal fractures in 1403 patients, who
fitted our inclusion criteria. There were 1024 men, and mean age
at injury was 40.6 years. Fractures were classified according to
the AO system, and open fractures graded after Gustilo and Anderson.
Requirement of fasciotomy, time to fracture union, complications,
incidence of knee and ankle pain at long-term follow-up, changes in
employment and the patients’ social deprivation status were recorded.
Function was assessed at 12 to 22 years post-injury using the Short
Musculoskeletal Function Assessment and short form-12 questionnaires.
Long-term functional outcome data was available for 568 of the surviving
patients, 389 were deceased and 346 were lost to follow-up. Most
fractures (90.7%, n = 1363) united without further intervention.
Fasciotomies were performed in 11.5% of patients; this did not correlate
with poorer functional outcome in the long term. Social deprivation
was associated with a higher incidence of injury but had no impact
on long-term function. The one-year mortality in those over 75 years
of age was 29 (42%). At long-term follow-up, pain and function scores
were good. However, 147 (26%) reported ongoing knee pain, 62 (10%)
reported ankle pain and 97 (17%) reported both. Such joint pain correlated
with poorer functional outcome. Cite this article:
Infected nonunion of a long bone continues to
present difficulties in management. In addition to treating the infection,
it is necessary to establish bony stability, encourage fracture
union and reconstruct the soft-tissue envelope. We present a series of 67 infected nonunions of a long bone in
66 patients treated in a multidisciplinary unit. The operative treatment
of patients suitable for limb salvage was performed as a single
procedure. Antibiotic regimes were determined by the results of
microbiological culture. At a mean follow-up of 52 months (22 to 97), 59 patients (88%)
had an infection-free united fracture in a functioning limb. Seven
others required amputation (three as primary treatment, three after
late failure of limb salvage and one for recalcitrant pain after
union). The initial operation achieved union in 54 (84%) of the salvaged
limbs at a mean of nine months (three to 26), with recurrence of
infection in 9%. Further surgery in those limbs that remained ununited
increased the union rate to 62 (97%) of the 64 limbs treated by
limb salvage at final follow-up. The use of internal fixation was
associated with a higher risk of recurrent infection than external
fixation. Cite this article:
The February 2015 Trauma Roundup360 looks at: Evaluating the syndesmosis in ankle fractures; Calcaneal fracture management an ongoing problem; Angular stable locking in low tibial fractures did not improve results; Open fractures: do the seconds really count?; Long-term outcomes of tibial fractures; Targeted performance improvements in pelvic fractures
Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest. The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion.
We present two cases of metastatic lung cancer which occurred at the site of a previously united tibial fracture. Both patients were treated with a locked intramedullary nail. The patients presented with metastases at the site of their initial fracture approximately 16 and 13 months after injury respectively. We discuss this unusual presentation and review the relevant literature. We are unaware of any previous reports of a metastatic tumour occurring at the site of an orthopaedic implant used to stabilise a non-pathological fracture. These cases demonstrate the similar clinical presentation of infection and malignancy: a diagnosis which should always be considered in such patients.
Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device. The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.
This study explores the relationship between
delay to surgical debridement and deep infection in a series of
364 consecutive patients with 459 open fractures treated at an academic
level one trauma hospital in North America. The mean delay to debridement for all fractures was 10.6 hours
(0.6 to 111.5). There were 46 deep infections (10%). There were
no infections among the 55 Gustilo-Anderson grade I open fractures.
Among the grade II and III injuries, a statistically significant
increase in the rate of deep infection was found for each hour of
delay (OR = 1.033: 95% CI 1.01 to 1.057). This relationship shows
a linear increase of 3% per hour of delay. No distinct time cut-off
points were identified. Deep infection was also associated with
tibial fractures (OR = 2.44: 95% CI 1.26 to 4.73), a higher Gustilo-Anderson
grade (OR = 1.99: 95% CI 1.004 to 3.954), and contamination of the
fracture (OR = 3.12: 95% CI 1.36 to 7.36). These individual effects
are additive, which suggests that delayed debridement will have
a clinically significant detrimental effect on more severe open
fractures. Delayed treatment appeared safe for grade 1 open fractures. However,
when the negative prognostic factors of tibial site, high grade
of fracture and/or contamination are present we recommend more urgent
operative debridement. Cite this article:
The February 2014 Trauma Roundup360 looks at: predicting nonunion; compartment Syndrome; octogenarian RTCs; does HIV status affect decision making in open tibial fractures?; flap timing and related complications; proximal humeral fractures under the spotlight; restoration of hip architecture with bipolar hemiarthroplasty in the elderly; and short
The October 2013 Trauma Roundup360 looks at: Radiological, electromagnetic or just leave it out altogether?: distal locking in intramedullary nailing; Internal fixation of radiation-induced pathological fractures of the femur has a high rate of failure; Obesity and trauma; Short and sweet?: antibiotics in open fractures; Extremity injuries more important than previously thought?; Cement nails tiptop for osteomyelitis; Oxygen measurements for compartment syndrome?
We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.
Radiological imaging is necessary in a wide variety
of trauma and elective orthopaedic operations. The evolving orthopaedic
workforce includes an increasing number of pregnant workers. Current
legislation in the United Kingdom, Europe and United States allows
them to choose their degree of participation, if any, with fluoroscopic procedures.
For those who wish to engage in radiation-prone procedures, specific
regulations apply to limit the radiation dose to the pregnant worker
and unborn child. This paper considers those aspects of radiation protection, the
potential effects of exposure to radiation in pregnancy and the
dose of radiation from common orthopaedic procedures, which are
important for safe clinical practice.
Controversy continues to surround the management
of patients with an open fracture of the lower limb and an associated
vascular injury (Gustilo type IIIC). This study reports our 15-year
experience with these fractures and their outcome in 18 patients
(15 male and three female). Their mean age was 30.7 years (8 to
54) and mean Mangled Extremity Severity Score (MESS) at presentation
was 6.9 (3 to 10). A total of 15 lower limbs were salvaged and three underwent
amputation (two immediate and one delayed). Four patients underwent
stabilisation of the fracture by external fixation and 12 with an
internal device. A total of 11 patients had damage to multiple arteries
and eight had a vein graft. Wound cover was achieved with a pedicled
flap in three and a free flap in six. Seven patients developed a
wound infection and four developed nonunion requiring further surgery.
At a mean follow-up of five years (4.1 to 6.6) the mean visual analogue
scale for pain was 64 (10 to 90). Depression and anxiety were common.
Activities were limited mainly because of pain, and the MESS was
a valid predictor of the functional outcome. Distal tibial fractures
had an increased rate of nonunion when associated with posterior
tibial artery damage, and seven patients (39%) were not able to
return to their previous occupation.
Fluoronavigation is an image-guided technology which uses intra-operative fluoroscopic images taken under a real-time tracking system and registration to guide surgical procedures. With the skeleton and the instrument registered, guidance under an optical tracking system is possible, allowing fixation of the fracture and insertion of an implant. This technology helps to minimise exposure to x-rays, providing multiplanar views for monitoring and accurate positioning of implants. It allows real-time interactive quantitative data for decision-making and expands the application of minimally invasive surgery. In orthopaedic trauma its use can be further enhanced by combining newer imaging technologies such as intra-operative three-dimensional fluoroscopy and optical image guidance, new advances in software for fracture reduction, and new tracking mechanisms using electromagnetic technology. The major obstacles for general and wider applications are the inability to track individual fracture fragments, no navigated real-time fracture reduction, and the lack of an objective assessment method for cost-effectiveness. We believe that its application will go beyond the operating theatre and cover all aspects of patient management, from pre-operative planning to intra-operative guidance and postoperative rehabilitation.
We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment. The use of intramedullary nails prevented recurrence of deformity and refracture.