Advertisement for orthosearch.org.uk
Results 41 - 56 of 56
Results per page:
Bone & Joint Research
Vol. 3, Issue 3 | Pages 60 - 68
1 Mar 2014
Langton DJ Sidaginamale RP Holland JP Deehan D Joyce TJ Nargol AVF Meek RD Lord JK

Objectives

Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing has been debated, with some investigators stating that only protocols involving hundreds of thousands of measurement points are sufficient. We looked to examine this assumption and to apply the findings to the clinical arena.

Methods

We examined the effects on the calculated material loss from a ceramic femoral head when different CMM scanning parameters were used. Calculated wear volumes were compared with gold standard gravimetric tests in a blinded study.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 12 - 16
1 Oct 2014

The October 2014 Knee Roundup360 looks at: microfracture equivalent to OATS; examination better than MRI in predicting hamstrings re-injury; a second view on return to play with hamstrings injuries; dislocation risks in the Oxford Unicompartmental Knee; what about the tibia?; getting on top of lateral facet pain post TKR; readmission in TKR; patient-specific instrumentation; treating infrapatellar saphenous neuralgia; and arthroscopy in the middle-aged.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 22 - 24
1 Aug 2013

The August 2013 Trauma Roundup360 looks at: reverse oblique fractures do better with a cephalomedullary device; locking screws confer no advantage in tibial plateau fractures; it’s all about the radius of curvature; radius of curvature revisited; radial head replacement in complex elbow reconstruction; stem cells in early fracture haematoma; heterotrophic ossification in forearms; and Boston in perspective.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1621 - 1621
1 Dec 2010
Paterson JMH


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154).

Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications.

We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 315 - 320
1 Mar 2006
Field RE Singh PJ Latif AMH Cronin MD Matthews DJ

We describe the results at five years of a prospective study of a new tri-tapered polished, cannulated, cemented femoral stem implanted in 51 patients (54 hips) with osteoarthritis. The mean age and body mass index of the patients was 74 years and 27.9, respectively. Using the anterolateral approach, half of the stems were implanted by a consultant orthopaedic surgeon and half by six different registrars. There were three withdrawals from the study because of psychiatric illness, a deep infection and a recurrent dislocation. Five deaths occurred prior to five-year follow-up and one patient withdrew from clinical review.

In the remaining 51 hips the mean pre-operative Oxford hip score was 47 points which decreased to 19 points at five years (45 hips). Of the stems 49 (98%) were implanted within 1° of neutral in the femoral canal. The mean migration of the stem at five years was 1.9 mm and the survivorship for aseptic loosening was 100%. There was no significant difference in outcome between the consultant and registrar groups. At five years, the results were comparable with those of other polished, tapered, cemented stems. Long-term surveillance continues.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1414 - 1421
1 Nov 2008
Arya AP Klenerman L

The Jaipur foot was developed for barefoot amputees by Professor P. K. Sethi. He used local artisans and readily available materials. The prosthesis was cheap and could be made in one hour. It enabled amputees to work in rural conditions, muddy and wet fields and to climb trees. It has been widely used in India, South East Asia and Africa, where local variations to the design have now been made.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (sd) as endpoints. The Constant score was found to improve from a mean of 26.8 (sd 10.3) pre-operatively to 57.6 (sd 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (sd 27.4) pre-operatively to 125° (sd 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (sd 6.5) pre-operatively to 30.3° (sd 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years.

Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1284 - 1290
1 Oct 2008
Ihle M Mai S Pfluger D Siebert W

In a prospective study, 93 unselected consecutive uncemented hip arthroplasties were performed in 80 patients using the titanium-coated RM acetabular component and the CLS femoral component. The mean age of the patients at operation was 52 years (28 to 81). None were lost to follow-up. In the 23 patients who had died (26 hips) only one acetabular component had been revised. In the 57 living patients (67 hips), 13 such revisions had been performed. Of the 14 revisions, seven were for osteolysis, five for loosening and two for infection.

Survival analysis of this implant showed a total probability of survival of 83% (95% confidence interval 73 to 90), with all revisions as the endpoint, and a probability of 94% (95% confidence interval 87 to 98) with revision for aseptic loosening as the endpoint, indicating reliable long-term fixation of the titanium-coated RM acetabular component.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 935 - 940
1 Jul 2010
McCalden RW Charron KD Yuan X Bourne RB Naudie DD MacDonald SJ

This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised controlled trial in which 17 patients received a dedicated radiostereometric CPCS stem and 17 a radiostereometric Exeter stem. No difference was found in any of the outcome measures pre-operatively or post-operatively between groups. At two years, the mean subsidence for the CPCS stem was nearly half that seen for the Exeter stem (0.77 mm (−0.943 to 1.77) and 1.25 mm (0.719 to 1.625), respectively; p = 0.032). In contrast, the mean internal rotation of the CPCS stem was approximately twice that of the Exeter (1.61° (−1.07° to 4.33°) and 0.59° (0.97° to 1.64°), respectively; p = 0.048). Other migration patterns were not significantly different between the stems. The subtle differences in designs may explain the different patterns of migration.

Comparable migration with the Exeter stem suggests that the CPCS design will perform well in the long term.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function.

No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1579 - 1582
1 Dec 2009
Starks I Roberts S White SH

We present a prospective review of the two-year functional outcome of 37 Avon patellofemoral joint replacements carried out in 29 patients with a mean age of 66 years (30 to 82) between October 2002 and March 2007. No patients were lost to follow-up. This is the first independent assessment of this prosthesis using both subjective and objective analysis of outcome. At two years the median Oxford knee score was 39 (interquartile range 32 to 44), the median American Knee Society objective score was 95 (interquartile range 90 to 100), the median American Knee Society functional score was 85 (interquartile range 60 to 100), and the median Melbourne Knee score was 28 (interquartile range 21 to 30). Two patients underwent further surgery. Only one patient reported an unsatisfactory outcome.

We conclude that the promising early results observed by the designing centre are reproducible and provide further support for the role of patellofemoral joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1454 - 1459
1 Nov 2006
Brouwer RW Bierma-Zeinstra SMA van Raaij TM Verhaar JAN

A prospective, randomised, controlled trial compared two different techniques of high tibial osteotomy with a lateral closing wedge or a medial opening wedge, stabilised by a Puddu plate. The clinical outcome and radiological results were examined at one year.

The primary outcome measure was the achievement of an overcorrection of valgus of 4°. Secondary outcome measures were the severity of pain (visual analogue scale), knee function (Hospital for Special Surgery score), and walking distance.

Between January 2001 and April 2004, 92 patients were randomised to one or other of the techniques. At follow-up at one year the post-operative hip-knee-ankle angle was 3.4° (± 3.6° sd) valgus after a closing wedge and 1.3° (± 4.7° sd) of valgus after an opening wedge. The adjusted mean difference of 2.1° was significant (p = 0.02). The deviation from 4° of valgus alignment was 2.7° (± 2.4° sd) in the closing wedge and 4.0° (± 3.6° sd) in the opening-wedge groups. The adjusted mean difference of 1.67° was also significant (p = 0.01).

The severity of pain, knee score and walking ability improved in both groups, but the difference was not significant.

Because of pain, the staples required removal in 11 (23%) patients in the closing-wedge group and a Puddu plate was removed in 27 (60%) patients in the opening-wedge group. This difference was significant (p < 0.001).

We conclude that closing-wedge osteotomy achieves a more accurate correction with less morbidity, although both techniques had improved the function of the knee at one year after the procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 730 - 737
1 Jun 2009
Carrington NC Sierra RJ Gie GA Hubble MJW Timperley AJ Howell JR

The first 325 Exeter Universal stems (309 patients) implanted at the originating centre were inserted between March 1988 and February 1990 by a group of surgeons with differing experience. In this report we describe the clinical and radiological results at a mean of 15.7 years (14.7 to 17.3) after operation with no loss to follow-up. There were 97 patients (108 hips) with replacements still in situ and 31 (31 hips) who had undergone a further procedure. With an endpoint of revision for aseptic loosening, the survivorship at 17 years was 100% and 90.4% for the femoral and acetabular component, respectively. The mean Merle D’Aubigné and Postel scores at review were 5.4 (sd 0.97) for pain and 4.5 (sd 1.72) for function. The mean Oxford score was 38.4 (sd 9.8) (0 to 48 worst-to-best scale) and the mean combined Harris pain and function score was 73.2 (sd 16.9). Radiological review showed excellent preservation of bone stock in the proximal femur and no failures of the femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 972 - 975
1 Jul 2006
Spencer JMF Day RE Sloan KE Beaver RJ

Our aim was to assess the intra- and inter-observer reliability in the establishment of the anterior pelvic plane used in imageless computer-assisted navigation. From this we determined the subsequent effects on version and inclination of the acetabular component.

A cadaver model was developed with a specifically-designed rod which held the component tracker at a fixed orientation to the pelvis, leaving the anterior pelvic plane as the only variable. Eight surgeons determined the anterior pelvic plane by palpating and registering the bony landmarks as reference points. The exact anterior pelvic plane was then established by using anatomically-placed bone screws as reference points.

The difference between the surgeons was found to be highly significant (p < 0.001). The variation was significantly larger for anteversion (sd 9.6°) than for inclination (sd 6.3°). The present method for registering pelvic landmarks shows significant inaccuracy, which highlights the need for improved methods of registration before this technique is considered to be safe.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1574 - 1579
1 Dec 2006
Pihlajamäki HK Ruohola J Weckström M Kiuru MJ Visuri TI

The incidence and long-term outcome of undisplaced fatigue fractures of the femoral neck treated conservatively were examined in Finnish military conscripts between 1970 and 1990.

From 106 cases identified, 66 patients with 70 fractures were followed for a mean of 18.3 years (11 to 32). The original medical records and radiographs were studied and physical and radiological follow-up data analysed for evidence of risk factors for this injury. The development of avascular necrosis and osteoarthritis was determined from the follow-up radiographs and MR scans.

The impact of new military instructions on the management of hip-related pain was assessed following their introduction in 1986. The preventive regimen (1986) improved awareness and increased the detected incidence from 13.2 per 100 000 service-years (1970 to 1986) to 53.2 per 100 000 (1987 to 1990). No patient developed displacement of the fracture or avascular necrosis of the femoral head, or suffered from adverse complications. No differences were found in MRI-measured hip joint spaces at final follow-up. The mean Harris Hip Score was 97 (70 to 100) and the Visual Analogue Scale 5.85 mm (0 to 44).

Non-operative treatment, including avoidance of or reduced weight-bearing, gave favourable short- and long-term outcomes. Undisplaced fatigue fractures of the femoral neck neither predispose to avascular necrosis nor the subsequent development of osteoarthritis of the hip.