Advertisement for orthosearch.org.uk
Results 41 - 60 of 1527
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 428 - 431
1 May 1994
Naito M Ogata K Shiota E Nakamoto M Goya T

We retrospectively reviewed 17 hip arthroplasties in 15 patients having haemodialysis for chronic renal failure. The duration of haemodialysis before the operation averaged 8.6 years and the average age of the patients was 61 years. All patients were followed for more than two years (mean 4.6 years). Six arthroplasties in four patients had failed due to loosening, and one of these patients died from undiagnosed infection of both hips at 7.6 years after the operation. General skeletal abnormalities caused by maintenance haemodialysis may explain the high incidence of loosening and it is important to be aware of the danger of postoperative infection. The risk-to-benefit ratio of hip arthroplasty is high in patients on haemodialysis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 195 - 199
1 Mar 1996
Dickob M Martini T

We implanted 300 uncoated cementless PM prostheses into 271 patients and followed 251 (92.6%) of them for four to seven years. By then 37 had already been revised for aseptic and three for septic loosening. The survival rate with implant failure as the endpoint was 88.8% for the cup and 85.3% for the stem after six years. There was a higher risk of implant loosening in congenital dysplasia, unilateral hip arthroplasty and obesity. The results of 225 unrevised hip replacements were assessed by questionnaire. Only 27.4% of the patients were completely free from pain and 17.9% had pain on walking any distance or at all times. The walking distance was for less than 30 minutes in 40%. Because of the poor results in comparison with other prostheses we do not recommend further use of the uncoated PM prosthesis


Bone & Joint Open
Vol. 3, Issue 7 | Pages 536 - 542
11 Jul 2022
Karayiannis PN Agus A Bryce L Hill JC Beverland D

Aims

Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT.

Methods

TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims

Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA).

Methods

We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 818 - 821
1 Aug 2003
Hsieh P Chen L Lee M Chen C Yang W Shih C

We retrospectively reviewed 45 hip arthroplasties which were performed over a period of 20 years in 38 patients with cirrhosis of the liver. There was a high perioperative 30-day complication rate (26.7%). Advanced cirrhosis was associated with a higher risk of complications (p = 0.004) as also was increased age, a high level of creatinine, a low level of albumin, a low platelet count, ascites, encephalopathy and an increased operative blood loss. The survival of the prosthesis at five years was 77.8% and infection was a major cause of failure. In view of the high rate of early complications and the limited longevity of the prosthesis, surgeons who perform hip arthroplasty on such patients should counsel them appropriately preoperatively


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 367 - 371
1 May 1992
Acurio M Friedman R

We reviewed retrospectively 25 hip arthroplasties in 25 patients with sickle-cell haemoglobinopathy and osteonecrosis. The mean age of the ten women and 15 men at the onset of hip symptoms was 25 years, and at surgery 30 years (16 to 45); 66% had either SS or S-thal disease, 20% sickle-cell trait, and the remainder SC disease. The mean follow-up was 8.6 years (two to 18). Fourteen (40%) of the arthroplasties had been revised at a mean of 7.5 years after the primary procedure and nine other hips were either radiographically and/or symptomatically loose. The overall complication rate was 49% and the infection rate 20%. The risk-to-benefit ratio of hip arthroplasty in sickle-cell haemoglobinopathy is high


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 184 - 191
1 Feb 2017
Pierrepont J Hawdon G Miles BP Connor BO Baré J Walter LR Marel E Solomon M McMahon S Shimmin AJ

Aims. The pelvis rotates in the sagittal plane during daily activities. These rotations have a direct effect on the functional orientation of the acetabulum. The aim of this study was to quantify changes in pelvic tilt between different functional positions. Patients and Methods. Pre-operatively, pelvic tilt was measured in 1517 patients undergoing total hip arthroplasty (THA) in three functional positions – supine, standing and flexed seated (the moment when patients initiate rising from a seated position). Supine pelvic tilt was measured from CT scans, standing and flexed seated pelvic tilts were measured from standardised lateral radiographs. Anterior pelvic tilt was assigned a positive value. Results. The mean pelvic tilt was 4.2° (-20.5° to 24.5°), -1.3° (-30.2° to 27.9°) and 0.6° (-42.0° to 41.3°) in the three positions, respectively. The mean sagittal pelvic rotation from supine to standing was -5.5° (-21.8° to 8.4°), from supine to flexed seated was -3.7° (-48.3° to 38.6°) and from standing to flexed seated was 1.8° (-51.8° to 39.5°). In 259 patients (17%), the extent of sagittal pelvic rotation could lead to functional malorientation of the acetabular component. Factoring in an intra-operative delivery error of ± 5° extends this risk to 51% of patients. Conclusion. Planning and measurement of the intended position of the acetabular component in the supine position may fail to predict clinically significant changes in its orientation during functional activities, as a consequence of individual pelvic kinematics. Optimal orientation is patient-specific and requires an evaluation of functional pelvic tilt pre-operatively. Cite this article: Bone Joint J 2017;99-B:184–91


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 867 - 875
1 Jul 2011
Rolfson O Kärrholm J Dahlberg LE Garellick G

We present the development and results of a nationwide, prospective, observational follow-up programme including patient-reported outcome measures (PROMs) for the Swedish Hip Arthroplasty Register. The programme started in 2002 and has gradually expanded to include all units performing total hip replacement in Sweden. The self-administered PROMs protocol comprises the EQ-5D instrument, the Charnley class categorisation and visual analogue scales for pain and satisfaction. These current analyses include 34 960 total hip replacements with complete pre- and one-year post-operative questionnaires. Patients eligible for total hip replacement generally report low health-related quality of life and suffer from pain. One year post-operatively the mean EQ-5D index increased to above the level of an age- and gender-matched population, with a considerable reduction of pain (p < 0.001). Females, younger patients and those with Charnley category C reported a lower EQ-5D index pre-operatively than males, older patients and Charnley category A or B, respectively (all p < 0.001). In a multivariable regression analysis Charnley category C, male gender and higher age were associated with less improvement in health-related quality of life (p < 0.001). Nationwide implementation of a PROMs programme requires a structured organisation and effective data capture. Patients’ response rates to the Registry are good. The continuous collection of PROMs permits local and national improvement work and allows for further health-economic evaluation


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 725 - 727
1 Sep 1994
James P Butcher I Gardner E Hamblen D

We investigated the incidence of cephalosporin-resistant bacteria in infected hip arthroplasties. Of 740 patients having hip replacement or related procedures performed over three years, 30 had positive bacteriological cultures from tissue removed at the time of surgery. In 18 of the 30 cultures Staphylococcus epidermidis was grown and 12 of these were methicillin-resistant. A prospective study of skin swabs taken from 100 consecutive patients at the time of admission for THR showed methicillin-resistant Staphylococcus epidermidis in 25. This cephalosporin-resistant organism was shown to be the commonest proven cause of infection, and its presence as a skin commensal raises important questions about current antibiotic prophylaxis for joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 289 - 296
1 Aug 1975
Jones DA Lucas HK O"Driscoll M Price CHG Wibberley B

The significance of cobalt as a cause of symptoms after McKee hip arthroplasty is discussed. Seven patients are described in whom such arthroplasties became unsatisfactory after periods varying from nine months to four years. Six of these patients were cobalt-positive but nickel-and chrome-negative on patch testing. Macroscopic and histological necrosis of bone, muscle and joint capsule around the prostheses was found in five patients whose hips were explored. The symptoms were progressive pain, a feeling of instability, and in two cases spontaneous dislocation. Radiological features included acetabular fracture, bone resorption, loosening and dislocation of the prosthesis. Increased cobalt concentrations (determined by atomic absorption spectrophotometry) in the urine of four patients and in a variety of tissues in one patient are presented. Patch testing is recommended in the investigation of patients with troublesome McKee hip arthroplasties


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1128 - 1135
14 Sep 2020
Khoshbin A Haddad FS Ward S O hEireamhoin S Wu J Nherera L Atrey A

Aims

The rate of dislocation when traditional single bearing implants are used in revision total hip arthroplasty (THA) has been reported to be between 8% and 10%. The use of dual mobility bearings can reduce this risk to between 0.5% and 2%. Dual mobility bearings are more expensive, and it is not clear if the additional clinical benefits constitute value for money for the payers. We aimed to estimate the cost-effectiveness of dual mobility compared with single bearings for patients undergoing revision THA.

Methods

We developed a Markov model to estimate the expected cost and benefits of dual mobility compared with single bearing implants in patients undergoing revision THA. The rates of revision and further revision were calculated from the National Joint Registry of England and Wales, while rates of transition from one health state to another were estimated from the literature, and the data were stratified by sex and age. Implant and healthcare costs were estimated from local procurement prices and national tariffs. Quality-adjusted life-years (QALYs) were calculated using published utility estimates for patients undergoing THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1623 - 1626
1 Dec 2008
Kulkarni A Partington P Kelly D Muller S

Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by ‘reverse calibration’ of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere. The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 475 - 478
1 May 1993
Lieberman Huo M Schneider R Salvati E Rodi S

We reviewed the plain radiographs, bone scans and hip aspiration results of 54 patients with painful hip arthroplasties which had been explored surgically, to compare the results of the investigations with the operative findings. For acetabular loosening, the sensitivity and specificity of bone scanning were 87% and 95%, with an accuracy of 90%: for serial plain radiography sensitivity was 95%, specificity 100% and accuracy 97%. For femoral component loosening, bone scan sensitivity was 85%, specificity 100% and accuracy 89%: the sensitivity of plain radiography was 100%, with specificity 92% and accuracy 98%. Technetium bone scanning did not provide additional information with regard to loosening and is not necessary in the routine investigation of a painful hip arthroplasty. Serial pain radiography is the most effective method of detecting loosening, and bone scanning is useful only when radiography is inconclusive with regard to loosening or infection


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 11 - 15
1 Jan 2024
Jain S Lamb JN Pandit H

Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in primary total hip arthroplasty (THA) in the UK. Due to low rates of aseptic loosening, they have largely replaced more traditional composite beam (CB) cemented stems. However, there is now emerging evidence from multiple joint registries that PTS stems are associated with higher rates of postoperative periprosthetic femoral fracture (PFF) compared to their CB stem counterparts. The risk of both intraoperative and postoperative PFF remains greater with uncemented stems compared to either of these cemented stem subtypes. PFF continues to be a devastating complication following primary THA and is associated with high complication and mortality rates. Recent efforts have focused on identifying implant-related risk factors for PFF in order to guide preventative strategies, and therefore the purpose of this article is to present the current evidence on the effect of cemented femoral stem design on the risk of PFF.

Cite this article: Bone Joint J 2024;106-B(1):11–15.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 74 - 81
1 May 2024
Callary SA Broekhuis D Barends J Ramasamy B Nelissen RGHH Solomon LB Kaptein BL

Aims

The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) – the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) – using virtual modelling.

Methods

Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants.


Aims

The aim of this study was to evaluate the healthcare costs and benefits of enoxaparin compared to aspirin in the prevention of symptomatic venous thromboembolism (VTE) after total hip arthroplasty (THA) or total knee arthroplasty (TKA) using data from the CRISTAL trial.

Methods

This trial-based economic analysis reports value for money as incremental cost per quality-adjusted life-year (QALY) gained in 2022 Australian dollars, compared to a single threshold value of AUD$70,000 per QALY. Event costs were estimated based on occurrence of VTEs and bleeds, and on published guidelines for treatment. Unit costs were taken from Australian sources. QALYs were estimated using CRISTAL six-month follow-up data. Sensitivity analyses are presented that vary the cost of VTE treatment, and extend the analyses to two years.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims

The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit.

Methods

Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1020 - 1029
1 Sep 2023
Trouwborst NM ten Duis K Banierink H Doornberg JN van Helden SH Hermans E van Lieshout EMM Nijveldt R Tromp T Stirler VMA Verhofstad MHJ de Vries JPPM Wijffels MME Reininga IHF IJpma FFA

Aims

The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures.

Methods

A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1025 - 1031
1 Sep 2022
Thummala AR Xi Y Middleton E Kohli A Chhabra A Wells J

Aims

Pelvic tilt is believed to affect the symptomology of osteoarthritis (OA) of the hip by alterations in joint movement, dysplasia of the hip by modification of acetabular cover, and femoroacetabular impingement by influencing the impingement-free range of motion. While the apparent role of pelvic tilt in hip pathology has been reported, the exact effects of many forms of treatment on pelvic tilt are unknown. The primary aim of this study was to investigate the effects of surgery on pelvic tilt in these three groups of patients.

Methods

The demographic, radiological, and outcome data for all patients operated on by the senior author between October 2016 and January 2020 were identified from a prospective registry, and all those who underwent surgery with a primary diagnosis of OA, dysplasia, or femoroacetabular impingement were considered for inclusion. Pelvic tilt was assessed on anteroposterior (AP) standing radiographs using the pre- and postoperative pubic symphysis to sacroiliac joint (PS-SI) distance, and the outcomes were assessed with the Hip Outcome Score (HOS), International Hip Outcome Tool (iHOT-12), and Harris Hip Score (HHS).


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 31 - 37
1 Mar 2024
Bunyoz KI Tsikandylakis G Mortensen K Gromov K Mohaddes M Malchau H Troelsen A

Aims

In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients.

Methods

A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively.