Advertisement for orthosearch.org.uk
Results 41 - 60 of 4512
Results per page:
Bone & Joint Open
Vol. 2, Issue 7 | Pages 552 - 561
28 Jul 2021
Werthel J Boux de Casson F Burdin V Athwal GS Favard L Chaoui J Walch G

Aims

The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts.

Methods

In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 690 - 695
1 May 2016
Dodd A Osterhoff G Guy P Lefaivre KA

We performed a systematic review of the literature pertaining to the functional outcomes of the surgical management of acetabular fractures. A total of 69 articles met our inclusion criteria, revealing that eight generic outcome instruments were used, along with five specific instruments. The majority of studies reported outcomes using a version of the d’Aubigne and Postel score, which has not been validated for use in acetabular fracture. Few validated outcome measures were reported. No psychometric testing of outcome instruments was performed. The current assessment of outcomes in surgery for acetabular fractures lacks scientific rigour, and does not give reliable outcome data for either scientific comparison or patient counselling. Take home message: The use of non-validated functional outcome measures is a major limitation of the current literature pertaining to surgical management of acetabular fractures; future studies should use validated outcome measures to ensure the legitimacy of the reported results. Cite this article: Bone Joint J 2016;98-B:690–5


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 3 - 9
1 Jan 2015
Hossain FS Konan S Patel S Rodriguez-Merchan EC Haddad FS

The routine use of patient reported outcome measures (PROMs) in evaluating the outcome after arthroplasty by healthcare organisations reflects a growing recognition of the importance of patients’ perspectives in improving treatment. Although widely embraced in the NHS, there are concerns that PROMs are being used beyond their means due to a poor understanding of their limitations. This paper reviews some of the current challenges in using PROMs to evaluate total knee arthroplasty. It highlights alternative methods that have been used to improve the assessment of outcome. Cite this article: Bone Joint J 2015;97-B:3–9


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1435 - 1437
1 Nov 2020
Katakura M Mitchell AWM Lee JC Calder JD


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 420 - 426
1 May 1999
Dawson J Fitzpatrick R Carr A

We have developed a 12-item questionnaire for completion by patients presenting with shoulder instability. A prospective study of 92 patients was undertaken involving two assessments, approximately six months apart, performed in an outpatient department. Each patient completed the new questionnaire and the SF36 form. An orthopaedic surgeon completed the Constant shoulder score and the Rowe assessment. The new questionnaire and the Rowe clinical score each achieved a large standardised effect size (≥0.8) and compared favourably with relevant items on the SF36. By contrast, the Constant score barely registered any effect, confirming that it may be relatively insensitive to changes in clinical status for this particular condition. The questionnaire provides a measurement of outcome for shoulder instability which is short, practical, reliable, valid and sensitive to changes of clinical importance


Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson correlation coefficient (r) between PROMs and SANE scores was -0.76 (p < 0.001) for DASH and -0.72 (p < 0.001) for PRWE, respectively. Limits of agreement between PROMs and ‘100-SANE’ scores were met for at least 93% of the data points. In subgroup analysis, there were significant negative correlations between PROMs and SANE scores for all age groups and for follow-up of more than six months. The correlation coefficient between PRWE subcategories and SANE score was -0.67 (p < 0.001) for PRWE pain score and -0.69 (p < 0.001) for PRWE function score, respectively. Conclusion. We found a significant correlation between postoperative SANE and PROMs in patients treated with a volar locking plate for a distal radial fracture. The SANE score is thus a reliable indicator of outcome for patients who undergo surgical treatment for a radial fracture. Cite this article: Bone Joint J 2020;102-B(6):744–748


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1556 - 1560
1 Nov 2014
Canavese F Charles YP Dimeglio A Schuller S Rousset M Samba A Pereira B Steib J

Assessment of skeletal age is important in children’s orthopaedics. We compared two simplified methods used in the assessment of skeletal age. Both methods have been described previously with one based on the appearance of the epiphysis at the olecranon and the other on the digital epiphyses. We also investigated the influence of assessor experience on applying these two methods. Our investigation was based on the anteroposterior left hand and lateral elbow radiographs of 44 boys (mean: 14.4; 12.4 to 16.1 ) and 78 girls (mean: 13.0; 11.1 to14.9) obtained during the pubertal growth spurt. A total of nine observers examined the radiographs with the observers assigned to three groups based on their experience (experienced, intermediate and novice). These raters were required to determined skeletal ages twice at six-week intervals. The correlation between the two methods was determined per assessment and per observer groups. Interclass correlation coefficients (ICC) evaluated the reproducibility of the two methods. The overall correlation between the two methods was r = 0.83 for boys and r = 0.84 for girls. The correlation was equal between first and second assessment, and between the observer groups (r ≥ 0.82). There was an equally strong ICC for the assessment effect (ICC ≤ 0.4%) and observer effect (ICC ≤ 3%) for each method. There was no significant (p < 0.05) difference between the levels of experience. The two methods are equally reliable in assessing skeletal maturity. The olecranon method offers detailed information during the pubertal growth spurt, while the digital method is as accurate but less detailed, making it more useful after the pubertal growth spurt once the olecranon has ossified. Cite this article: Bone Joint J 2014;3:1556–60


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1128 - 1135
14 Sep 2020
Khoshbin A Haddad FS Ward S O hEireamhoin S Wu J Nherera L Atrey A

Aims

The rate of dislocation when traditional single bearing implants are used in revision total hip arthroplasty (THA) has been reported to be between 8% and 10%. The use of dual mobility bearings can reduce this risk to between 0.5% and 2%. Dual mobility bearings are more expensive, and it is not clear if the additional clinical benefits constitute value for money for the payers. We aimed to estimate the cost-effectiveness of dual mobility compared with single bearings for patients undergoing revision THA.

Methods

We developed a Markov model to estimate the expected cost and benefits of dual mobility compared with single bearing implants in patients undergoing revision THA. The rates of revision and further revision were calculated from the National Joint Registry of England and Wales, while rates of transition from one health state to another were estimated from the literature, and the data were stratified by sex and age. Implant and healthcare costs were estimated from local procurement prices and national tariffs. Quality-adjusted life-years (QALYs) were calculated using published utility estimates for patients undergoing THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1321 - 1329
1 Oct 2012
Sarmah SS Patel S Hossain FS Haddad FS

Radiological assessment of total and unicompartmental knee replacement remains an essential part of routine care and follow-up. Appreciation of the various measurements that can be identified radiologically is important. It is likely that routine plain radiographs will continue to be used, although there has been a trend towards using newer technologies such as CT, especially in a failing knee, where it provides more detailed information, albeit with a higher radiation exposure. The purpose of this paper is to outline the radiological parameters used to evaluate knee replacements, describe how these are measured or classified, and review the current literature to determine their efficacy where possible


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 705 - 713
1 Jul 2004
Bhat M McCarthy M Davis TRC Oni JA Dawson S

We treated 50 patients with fractures of the waist of the scaphoid in a below-elbow plaster cast for up to 13 weeks. Displacement of the fragments was assessed independently by two observers using MRI and radiographs performed within two weeks of injury. The MRI assessments showed that only the measurement of sagittal translation of the fragments and an overall assessment of displacement had satisfactory inter- and intra-observer reproducibility and revealed that nine of the 50 fractures were displaced. Only three of the 49 fractures with adequate follow-up failed to unite, and all were displaced with more than 1 mm of translation in the sagittal plane. If the MRI assessment of displacement of the fracture was used as the measurement of choice, assessment of displacement on the initial scaphoid series of radiographs showed a sensitivity of between 33% and 47% and a positive predictive value of between 27% and 86%. Neither observer was able correctly to identify more than 33% to 47% of the displaced fractures from the plain radiographs. Although the overall assessment of displacement and gapping and translation in the coronal plane on the plain radiographs influenced the rate of union, none of these parameters identified all three fractures which failed to unite. We conclude that the assessment of displacement of scaphoid fractures on MRI can probably be used to assess the likelihood of union although the small number of nonunions limits the power of the study. In contrast, the assessment of displacement on routine radiography is inaccurate and of less value in predicting union


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 439 - 445
1 Nov 1977
Anderson E Frank P Henshaw J Rae H

A new cosmetic weight-relieving brace which utilises stainless steel and light alloy in its structure is described. A clinical assessment of thirty-six patients (four bilateral cases) has shown the Salford Cosmetic brace to be suitable for over 80 per cent of patients attending for assessment. Five patients rejected the brace, and the reasons are discussed. Contra-indications which emerged during the assessment included limb shortening of more than 5 centimetres; fixed equinus of more than 10 degrees; and fixed deformity of the knee of more than 10 degrees. The safety and durability of the brace, first demonstrated in laboratory tests, are confirmed. Further possible development is outlined


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 723 - 727
1 Nov 1988
Waddell G Reilly S Torsney B Allan D Morris E Di Paola M Bircher M Finlayson D

We aimed to develop a better understanding and method of rating the success or failure of low back surgery by studying 185 patients prospectively. Identical pre-operative and postoperative assessment by an independent observer included pain, disability, physical impairment, psychological distress and illness behaviour. Outcome was assessed by the patient, by the observer and by return to work. There was 96% follow-up at two years. Correlation co-efficients varied considerably between the various measures of outcome, both patient and observer appearing to base their assessment mainly on postoperative status rather than on any change produced by surgery. The observer was influenced most by postoperative pain, disability and physical impairment. Patients were influenced most by residual physical impairment, type of surgery and proportional change in disability. Return to work was moderately influenced by postoperative disability and to a larger extent by social and work-related factors. We developed a simple formula to judge overall success or failure which accurately reproduced the combined assessment of patient and observer. If surgical audit is to be meaningful it must be based on an improved understanding of how the outcome of surgery should be assessed


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims

The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture.

Methods

All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1167 - 1174
1 Sep 2016
Mineta K Goto T Wada K Tamaki Y Hamada D Tonogai I Higashino K Sairyo K

Aims. Femoroacetabular impingement (FAI) has been highlighted and well documented primarily in Western countries and there are few large studies focused on FAI-related morphological assessment in Asian patients. We chose to investigate this subject. Patients and Methods. We assessed the morphology of the hip and the prevalence of radiographic FAI in Japanese patients by measuring predictors of FAI. We reviewed a total of 1178 hips in 695 men and 483 women with a mean age of 58.2 years (20 to 89) using CT images that had been obtained for reasons unrelated to symptoms from the hip. We measured the lateral centre edge angle, acetabular index, crossover sign, alpha angle and anterior femoral head-neck offset ratio. Results. A total of 441 hips (37.4%) had pincer-type deformity (41.7% men, 31.3% women) and 534 (45.3%) had cam-type deformity (54.4% men, 32.3% women). Moreover, 773 hips (65.6%) had at least one parameter that predisposes to FAI (74.0% men, 53.6% women) and 424 hips (36.0%) had two or more parameters (43.6% men, 25.0% women). Conclusion. The prevalence of radiographic FAI was common in Japanese patients who are generally considered to have dysplastic hips. Cite this article: Bone Joint J 2016;98-B:1167–74


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 229 - 232
1 Mar 1996
Conboy VB Morris RW Kiss J Carr AJ

We have analysed the Constant-Murley (1987) assessment for 25 patients with shoulder pathology. We found the score easy to use, with low inter- and intraobserver errors, but sufficiently imprecise in repeated measurements to give concern in its use for clinical follow-up of patients. We have calculated 95% confidence limits for a single assessment to be within 16 to 20 points in most cases. In addition, we found that all our subjects with instability as their main problem scored within five points of the maximum; this suggests that the scoring method may need to be revised for use on these patients


Bone & Joint Research
Vol. 3, Issue 3 | Pages 69 - 75
1 Mar 2014
Parsons N Griffin XL Achten J Costa ML

Objectives. To study the measurement properties of a joint specific patient reported outcome measure, a measure of capability and a general health-related quality of life (HRQOL) tool in a large cohort of patients with a hip fracture. Methods. Responsiveness and associations between the Oxford Hip Score (a hip specific measure: OHS), ICEpop CAPability (a measure of capability in older people: ICECAP-O) and EuroQol EQ-5D (general health-related quality of life measure: EQ-5D) were assessed using data available from two large prospective studies. The three outcome measures were assessed concurrently at a number of fixed follow-up time-points in a consecutive sequence of patients, allowing direct assessment of change from baseline, inter-measure associations and validity using a range of statistical methods. Results. ICECAP-O was not responsive to change. EQ-5D was responsive to change from baseline, with an estimated standardised effect size for the two datasets of 0.676 and 0.644 at six weeks and four weeks respectively; this was almost as responsive to change as OHS (1.14 at four weeks). EQ-5D correlated strongly with OHS; Pearson correlation coefficients were 0.74, 0.77 and 0.70 at baseline, four weeks and four months. EQ-5D is a moderately good predictor of death at 12 months following hip fracture. Furthermore, EQ-5D reported by proxies (relatives and carers) behaves similarly to self-reported scores. Conclusions. Our findings suggest that a general HRQOL tool such as EQ-5D could be used to measure outcome for patients recovering from hip fracture, including those with cognitive impairment. Cite this article: Bone Joint Res 2014;3:69–75


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 122 - 127
1 Jan 2017
Weinberg DS Narayanan AS Moore TA Vallier HA

Aims. The best time for definitive orthopaedic care is often unclear in patients with multiple injuries. The objective of this study was make a prospective assessment of the safety of our early appropriate care (EAC) strategy and to evaluate the potential benefit of additional laboratory data to determine readiness for surgery. Patients and Methods. A cohort of 335 patients with fractures of the pelvis, acetabulum, femur, or spine were included. Patients underwent definitive fixation within 36 hours if one of the following three parameters were met: lactate < 4.0 mmol/L; pH ≥ 7.25; or base excess (BE) ≥ -5.5 mmol/L. If all three parameters were met, resuscitation was designated full protocol resuscitation (FPR). If less than all three parameters were met, it was designated an incomplete protocol resuscitation (IPR). Complications were assessed by an independent adjudication committee and included infection; sepsis; PE/DVT; organ failure; pneumonia, and acute respiratory distress syndrome (ARDS). . Results. In total, 66 patients (19.7%) developed 90 complications. An historical cohort of 1441 patients had a complication rate of 22.1%. The complication rate for patients with only one EAC parameter at the point of protocol was 34.3%, which was higher than other groups (p = 0.041). Patients who had IPR did not have significantly more complications (31.8%) than those who had FPR (22.6%; p = 0.078). Regression analysis showed male gender and injury severity score to be independent predictors of complications. Conclusions. This study highlights important trends in the IPR and FPR groups, suggesting that differences in resuscitation parameters may guide care in certain patients; further study is, however, required. We advocate the use of the existing protocol, while research is continued for high-risk subgroups. . Cite this article: Bone Joint J 2017;99-B:122–7


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 3 | Pages 423 - 425
1 Aug 1949
Brown JT

1. The end-results of conservative treatment of supraspinatus tears have been studied in a series of 109 patients graded on a clinical basis, and in a further series of twenty-seven patients assessed initially by procaine infiltration. 2. In 87 per cent. of patients with mild lesions, full function was regained in an average period of five and a half weeks. In more than 50 per cent. of patients with apparently severe lesions, there was full functional recovery in eleven to thirteen weeks. 3. Clinical assessment, other than as mild or apparently severe, is unreliable in the early stages. 4. Procaine infiltration of recent tears, by abolishing pain and spasm, allows more accurate assessment of supraspinatus function and gives a more clear indication as to the advisability of conservative or early operative treatment. If such infiltration of the torn segment of tendon fails to restore voluntary abduction power, early operative repair is indicated. 5. Six patients with negative procaine tests, in whom the shoulder cuff was subsequently explored, all showed extensive tears


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid. The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture. The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 19 - 23
1 Jan 2014
Sabharwal S Gauher S Kyriacou S Patel V Holloway I Athanasiou T

We evaluated the quality of guidelines on thromboprophylaxis in orthopaedic surgery by examining how they adhere to validated methodological standards in their development. A structured review was performed for guidelines that were published between January 2005 and April 2013 in medical journals or on the Internet. A pre-defined computerised search was used in MEDLINE, Scopus and Google to identify the guidelines. The AGREE II assessment tool was used to evaluate the quality of the guidelines in the study. . Seven international and national guidelines were identified. The overall methodological quality of the individual guidelines was good. ‘Scope and Purpose’ (median score 98% interquartile range (IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%, IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’ (median score 68%, IQR 45% to 75%) and ‘Editorial Independence’ (median score 71%, IQR 68% to 75%) had the lowest scores. . These findings reveal that although the overall methodological quality of guidelines on thromboprophylaxis in orthopaedic surgery is good, domains within their development, such as ‘Applicability’ and ‘Editorial Independence’, need to be improved. Application of the AGREE II instrument by the authors of guidelines may improve the quality of future guidelines and provide increased focus on aspects of methodology used in their development that are not robust. Cite this article: Bone Joint J 2014;96-B:19–23