The aim of this study was to report a single surgeon series of
consecutive patients with moderate hallux valgus managed with a
percutaneous extra-articular reverse-L chevron (PERC) osteotomy. A total of 38 patients underwent 45 procedures. There were 35
women and three men. The mean age of the patients was 48 years (17
to 69). An additional percutaneous Akin osteotomy was performed
in 37 feet and percutaneous lateral capsular release was performed
in 22 feet. Clinical and radiological assessments included the type
of forefoot, range of movement, the American Orthopedic Foot and
Ankle (AOFAS) score, a subjective rating and radiological parameters. The mean follow-up was 59.1 months (45.9 to 75.2). No patients
were lost to follow-up.Aims
Patients and Methods
We have reviewed the results of 106 intertrochanteric osteotomies performed for osteonecrosis of the femoral head. The average age at operation was 47.5 years. At two years from operation 71% of the hips had a
The aims of this study were to describe the course of non-operatively
managed, bilateral Perthes’ disease, and to determine specific prognostic
factors for the radiographic and clinical outcome. We identified 40 children with a mean age of 5.9 years (1.8 to
13.5), who were managed non-operatively for bilateral Perthes’ disease
from our prospective, multicentre study of this condition, which
included all children in Norway who were diagnosed with Perthes’
disease in the five-year period between 1996 and 2000. All children
were followed up for five years. The hips were classified according to the Catterall classification.
A modified three-group Stulberg classification was used as an outcome
measure, with a spherical femoral head being defined as a good outcome,
an oval head as fair, and a flat femoral head as a poor outcome. Aims
Patients and Methods
The custom triflange is a patient-specific implant
for the treatment of severe bone loss in revision total hip arthroplasty
(THA). Through a process of three-dimensional modelling and prototyping,
a hydroxyapatite-coated component is created for acetabular reconstruction.
There are seven level IV studies describing the clinical results
of triflange components. The most common complications include dislocation
and infection, although the rates of implant removal are low. Clinical
results are promising given the challenging problem. We describe
the design, manufacture and implantation process and review the
clinical results, contrasting them to other methods of acetabular
reconstruction in revision THA. Cite this article:
We reviewed 34 consecutive patients (18 female-16 male) with
isthmic spondylolysis and grade I to II lumbosacral spondylolisthesis
who underwent in situ posterolateral arthodesis between the L5 transverse
processes and the sacral ala with the use of iliac crest autograft.
Ten patients had an associated scoliosis which required surgical correction
at a later stage only in two patients with idiopathic curves unrelated
to the spondylolisthesis. No patient underwent spinal decompression or instrumentation
placement. Mean surgical time was 1.5 hours (1 to 1.8) and intra-operative
blood loss 200 ml (150 to 340). There was one wound infection treated
with antibiotics but no other complication. Radiological assessment
included standing posteroanterior and lateral, Ferguson and lateral flexion/extension
views, as well as CT scans. Aims
Methods
Dislocation of the acromioclavicular joint is
a relatively common injury and a number of surgical interventions
have been described for its treatment. Recently, a synthetic ligament
device has become available and been successfully used, however,
like other non-native solutions, a compromise must be reached when
choosing non-anatomical locations for their placement. This cadaveric
study aimed to assess the effect of different clavicular anchorage points
for the Lockdown device on the reduction of acromioclavicular joint
dislocations, and suggest an optimal location. We also assessed
whether further stability is provided using a coracoacromial ligament
transfer (a modified Neviaser technique). The acromioclavicular
joint was exposed on seven fresh-frozen cadaveric shoulders. The
joint was reconstructed using the Lockdown implant using four different
clavicular anchorage points and reduction was measured. The coracoacromial
ligament was then transferred to the lateral end of the clavicle,
and the joint re-assessed. If the Lockdown ligament was secured
at the level of the conoid tubercle, the acromioclavicular joint
could be reduced anatomically in all cases. If placed medial or
2 cm lateral, the joint was irreducible. If the Lockdown was placed
1 cm lateral to the conoid tubercle, the joint could be reduced
with difficulty in four cases. Correct placement of the Lockdown
device is crucial to allow anatomical joint reduction. Even when the
Lockdown was placed over the conoid tubercle, anterior clavicle
displacement remained but this could be controlled using a coracoacromial
ligament transfer. Cite this article:
If a modular convertible total shoulder system
is used as a primary implant for an anatomical total shoulder arthroplasty,
failure of the prosthesis or the rotator cuff can be addressed by
converting it to a reverse shoulder arthroplasty (RSA), with retention
of the humeral stem and glenoid baseplate. This has the potential
to reduce morbidity and improve the results. In a retrospective study of 14 patients (15 shoulders) with a
mean age of 70 years (47 to 83) we reviewed the clinical and radiological
outcome of converting an anatomical shoulder arthroplasty (ASA)
to a RSA using a convertible prosthetic system (SMR system, Lima,
San Daniele, Italy). The mean operating time was 64 minutes (45 to 75). All humeral
stems and glenoid baseplates were found to be well-fixed and could
be retained. There were no intra-operative or early post-operative
complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the
mean visual analogue scale for pain had decreased from 8 pre-operatively
to 1, the mean American Shoulder and Elbow Surgeons Score from 12
to 76, the mean Oxford shoulder score from 3 to 39, the mean Western
Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and
the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the
humeral stem, two had stress shielding. There were no fatigue fractures
of the acromion but four cases of grade 1 scapular notching. The use of a convertible prosthetic system to revise a failed
ASA reduces morbidity and minimises the rate of complications. The
mid-term clinical and radiological results of this technique are
promising. Cite this article:
The leading indication for revision total hip
arthroplasty (THA) remains aseptic loosening owing to wear. The younger,
more active patients currently undergoing THA present unprecedented
demands on the bearings. Ceramic-on-ceramic (CoC) bearings have
consistently shown the lowest rates of wear. The recent advances,
especially involving alumina/zirconia composite ceramic, have led
to substantial improvements and good results Alumina/zirconia composite ceramics are extremely hard, scratch
resistant and biocompatible. They offer a low co-efficient of friction
and superior lubrication and lower rates of wear compared with other
bearings. The major disadvantage is the risk of fracture of the
ceramic. The new composite ceramic has reduced the risk of fracture
of the femoral head to 0.002%. The risk of fracture of the liner
is slightly higher (0.02%). Assuming that the components are introduced without impingement,
CoC bearings have major advantages over other bearings. Owing to
the superior hardness, they produce less third body wear and are
less vulnerable to intra-operative damage. The improved tribology means that CoC bearings are an excellent
choice for young, active patients requiring THA. Cite this article:
We reviewed all 717 manuscripts published in the 1997 issues of the British and American volumes of the Journal of Bone and Joint Surgery and in Clinical Orthopaedics and Related Research, from which 33 randomised, controlled trials were identified. The results and sample sizes were used to calculate the statistical power of the study to distinguish small (0.2 of standard deviation), medium (0.5 of standard deviation), and large (0.8 of standard deviation) effect sizes. Of the 33 manuscripts analysed, only three studies (9%) described calculations of sample size. To perform post-hoc power assessments and estimations of deficiencies of sample size, the standard effect sizes of Cohen (small, medium and large) were calculated. Of the 25 studies which reported negative results, none had adequate power (β <
0.2) to detect a small effect size and 12 (48%) lacked the power necessary to detect a large effect size. Of the 25 studies which did not have an adequate size of sample to detect small differences, the average used was only 10% of the required number. Our findings suggest that randomised, controlled trials in clinical orthopaedic research utilise sample sizes which are too small to ensure statistical significance for what may be
Hip resurfacing has been proposed as an alternative
to traditional total hip arthroplasty in young, active patients.
Much has been learned following the introduction of metal-on-metal resurfacing
devices in the 1990s. The triad of a well-designed device, implanted
accurately, in the correct patient has never been more critical
than with these implants. Following Food and Drug Administration approval in 2006, we studied
the safety and effectiveness of one hip resurfacing device (Birmingham
Hip Resurfacing) at our hospital in a large, single-surgeon series.
We report our early to mid–term results in 1333 cases followed for
a mean of 4.3 years (2 to 5.7) using a prospective, observational
registry. The mean patient age was 53.1 years (12 to 84); 70% were
male and 91% had osteoarthritis. Complications were few, including
no dislocations, no femoral component loosening, two femoral neck
fractures (0.15%), one socket loosening (0.08%), three deep infections
(0.23%), and three cases of metallosis (0.23%). There were no destructive
pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship
in males under the age of 50 was 100%. We believe this is the largest
United States series of a single surgeon using a single resurfacing
system. Cite this article:
An extensive review of the spinal and arthroplasty
literature was undertaken to evaluate the effectiveness of local
antibiotic irrigation during surgery. The efficacy of antibiotic
irrigation for the prevention of acute post-operative infection
after total joint arthroplasty was evaluated retrospectively in
2293 arthroplasties (1990 patients) between January 2004 and December
2013. The mean follow-up was 73 months (20 to 139). One surgeon
performed all the procedures with minimal post-operative infection. The intra-operative protocol included an irrigation solution
of normal saline with vancomycin 1000 mg/l and polymyxin 250 000
units/l at the rate of 2 l per hour. No patient required re-admission
for primary infection or further antibiotic treatment. Two morbidly obese
patients (two total hip arthroplasties) developed subcutaneous fat
necrosis requiring debridement and one was revised because the deep
capsular sutures were contaminated by the draining subcutaneous
haematoma. One patient who had undergone total knee arthroplasty
had unrecognised damage to the lateral superior geniculate artery
and developed a haematoma that became infected secondarily four
months after the surgery and underwent revision. The use of antibiotic irrigation during arthroplasty surgery
has been highly effective for the prevention of infection in the
author’s practice. However, it should be understood that any routine
prophylactic use of antibiotics may result in resistant organisms,
and the wise stewardship of the use of antibiotics is an important
part of surgical practice. Cite this article:
The treatment of bone loss in revision total
knee arthroplasty has evolved over the past decade. While the management
of small to moderate sized defects has demonstrated good results
with a variety of traditional techniques (cement and screws, small
metal augments, impaction bone grafting or modular stems), the treatment of
severe defects continues to be problematic. The use of a structural
allograft has declined in recent years due to an increased failure
rate with long-term follow-up and with the introduction of highly
porous metal augments that emphasise biological metaphyseal fixation.
Recently published mid-term results on the use of tantalum cones
in patients with severe bone loss has reaffirmed the success of
this treatment strategy. Cite this article:
Given the increasing number of total hip arthroplasty
procedures being performed annually, it is imperative that orthopaedic
surgeons understand factors responsible for instability. In order
to treat this potentially complex problem, we recommend correctly
classifying the type of instability present based on component position, abductor
function, impingement, and polyethylene wear. Correct classification
allows the treating surgeon to choose the appropriate revision option
that ultimately will allow for the best potential outcome. Cite this article:
We describe our technique and rationale using
hybrid fixation for primary total hip arthroplasty (THA) at the Hospital
for Special Surgery. Modern uncemented acetabular components have
few screw holes, or no holes, polished inner surfaces, improved
locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented
sockets can be combined with highly cross-linked polyethylene liners,
which have demonstrated very low wear and osteolysis rates after
ten to 15 years of implantation. The results of cement fixation
with a smooth or polished surface finished stem have been excellent,
virtually eliminating complications seen with cementless fixation
like peri-operative femoral fractures and thigh pain. Although mid-term
results of modern cementless stems are encouraging, the long-term
data do not show reduced revision rates for cementless stems compared
with cemented smooth stems. In this paper we review the conduct
of a hybrid THA, with emphasis on pre-operative planning, surgical
technique, hypotensive epidural anaesthesia, and intra-operative
physiology. Cite this article:
The aims of this study were to report functional
outcomes of salvage procedures for patients with cerebral palsy (CP)
who have chronic dislocation of the hip using validated scoring
systems, and to compare the results of three surgical techniques. We reviewed 37 patients retrospectively. The mean age at the
time of surgery was 12.2 years (8 to 22) and the mean follow-up
was 56 months (24 to 114). Patients were divided into three groups:
14 who underwent proximal femoral resection arthroplasty (PFRA group
1), ten who underwent subtrochanteric valgus osteotomy (SVO group 2),
and 13 who underwent subtrochanteric valgus osteotomy with resection
of the femoral head (SVO with FHR group 3). All patients were evaluated
using the Caregiver Priorities and Child Health Index of Life with
Disabilities (CPCHILD) and the Pediatric Quality of Life Inventory
(PedsQL). Significant improvements occurred in most CPCHILD and PedsQL
subsection scores following surgery in all patients, without significant
differences between the groups. There were 12 post-operative complications.
Less severe complications were seen in group 1 than in groups 2
and 3. Salvage surgery appears to provide pain relief in patients with
CP who have painful chronic dislocation of the hip. The three salvage
procedures produced similar results, however, we recommend the use
of PFRA as the complications are less severe. Take home message: Salvage surgery can be of benefit to patients
with CP with chronic painful hip dislocation, but should be limited
to selected patients considering complications. Cite this article:
Oxidised zirconium was introduced as a material for femoral components
in total knee arthroplasty (TKA) as an attempt to reduce polyethylene
wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected
database to assess the ten year survival and clinical and radiological
outcomes of an oxidised zirconium total knee arthroplasty with the
Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis
Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS)
and a patient satisfaction scale were used to assess outcome.Aims
Methods
The purpose of this study was to develop a prognostic model for
predicting survival of patients undergoing surgery owing to metastatic
bone disease (MBD) in the appendicular skeleton. We included a historical cohort of 130 consecutive patients (mean
age 64 years, 30 to 85; 76 females/54 males) who underwent joint
arthroplasty surgery (140 procedures) owing to MBD in the appendicular
skeleton during the period between January 2003 and December 2008.
Primary cancer, pre-operative haemoglobin, fracture Aims
Methods
1. A series of 154 patients who underwent anterior cervical discectomy and fusion has been studied. A detailed analysis of the first eighty-four patients who have been observed for periods of from one to eight and a half years is described. In sixty-eight patients the fusion was done with a keystone type of graft, in seventeen by a dowel (Cloward) graft. 2. Despite a preponderance of multiple level fusions in the keystone series,