Advertisement for orthosearch.org.uk
Results 561 - 580 of 951
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1454
1 Nov 2018
Green CM Buckley SC Hamer AJ Kerry RM Harrison TP

Aims

The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction.

Patients and Methods

Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study.


Bone & Joint Research
Vol. 8, Issue 6 | Pages 275 - 287
1 Jun 2019
Clement ND Bardgett M Merrie K Furtado S Bowman R Langton DJ Deehan DJ Holland J

Objectives

Our primary aim was to describe migration of the Exeter stem with a 32 mm head on highly crosslinked polyethylene and whether this is influenced by age. Our secondary aims were to assess functional outcome, satisfaction, activity, and bone mineral density (BMD) according to age.

Patients and Methods

A prospective cohort study was conducted. Patients were recruited into three age groups: less than 65 years (n = 65), 65 to 74 years (n = 68), and 75 years and older (n = 67). There were 200 patients enrolled in the study, of whom 115 were female and 85 were male, with a mean age of 69.9 years (sd 9.5, 42 to 92). They were assessed preoperatively, and at three, 12 and, 24 months postoperatively. Stem migration was assessed using Einzel-Bild-Röntgen-Analyse (EBRA). Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), EuroQol-5 domains questionnaire (EQ-5D), short form-36 questionnaire (SF-36,) and patient satisfaction were used to assess outcome. The Lower Extremity Activity Scale (LEAS), Timed Up and Go (TUG) test, and activPAL monitor (energy expelled, time lying/standing/walking and step count) were used to assess activity. The BMD was assessed in Gruen and Charnley zones.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 11 - 17
1 Jan 1995
Havelin L Espehaug B Vollset S Engesaeter L

The Norwegian Arthroplasty Register recorded 24,408 primary total hip replacements from 1987 to 1993; 2907 of them (13%) were performed with uncemented femoral components. We have compared the results of eight different designs, each used in more than 100 patients. Survivorship of the components was estimated by the Kaplan-Meier method using revision for aseptic loosening of the femoral component as the end-point. At 4.5 years, the estimated probability of revision for aseptic loosening for all implants was 4.5%, for the Bio-Fit stem 18.6% (n = 210) and for the Femora stem 13.6% (n = 173). The PM-Prosthesis and the Harris/Galante stem prostheses needed revision in 5.6% and 3.6%, respectively. The clockwise threaded stem of the Femora implant needed revision in 20% of right hips, but in only 4% of left hips. The short-term results of the four best uncemented femoral components (Corail, LMT, Profile and Zweimuller) were similar to those for cemented stems, with revision for loosening in less than 1% at 4.5 years. The importance of the control of innovative designs and the registration of early results is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 835 - 842
1 Sep 1999
Allain J Le Mouel S Goutallier D Voisin MC

Between January 1988 and January 1991 we performed 100 consecutive cemented total hip replacements using a zirconia head, a titanium alloy stem and a polyethylene cup. We reviewed 78 of these hips in 61 patients in detail at a mean of 5.8 years (1 to 9). Aseptic loosening was seen in 11 hips (14%). Eight needed revision. In total, 37 cups (47.5%) showed radiolucent lines, all at the cement-bone interface, with 18 (23%) involving all the interface. Of the 78 femoral implants, 17 (21.7%) showed radiolucent lines, and two, which had a complete line of more than 1 mm thick, definite endocortical osteolyses. There was also an abnormally high incidence of osteolysis of more than 2 mm at the calcar. Survivorship analysis showed that only 63% were in situ at eight years. These worrying results led us to abandon the use of zirconia heads, since at the same hospital, using the same femoral stem, cement and polyethylene cup, but with alumina femoral heads, the survival rate was 93% at nine years. We discuss the possible reasons for the poor performance of zirconia ceramic


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 111 - 116
1 Jan 1986
Walker S Sharma P Parr N Cavendish M

We have reviewed 105 Liverpool Mark II knee replacements in 71 patients to assess survival and long-term results. Assessment was both clinical and radiological, using a modification of the British Orthopaedic Association knee function assessment chart, and analysis was by the survivorship method as advocated by Tew and Waugh. The follow-up period was between 13 and 113 months with 42 prostheses being in situ for over six years. Eight knees (7.6%) have been revised or arthrodesed because of infection or loosening, giving a cumulative success rate of 89% after seven years based on prosthesis survival alone. Of the remaining knees, 71.1% were either free of pain or caused only minimal pain. The cumulative success rate as judged by the stricter criteria of the prosthesis being in situ and causing little or no pain suggested a 50% survival between 73 and 96 months. Most patients (77.3%) were enthusiastic or satisfied with their results. Complications included deep wound infection (8.6%), and loosening which needed further surgery (11.4%)


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1133 - 1135
1 Sep 2018
Pairon P Haddad FS


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1033 - 1042
1 Aug 2018
Kayani B Konan S Pietrzak JRT Huq SS Tahmassebi J Haddad FS

Aims

The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA.

Patients and Methods

This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (sd 6.8) vs 64.1 years (sd 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (sd 2.7) vs 28.1 kg.m2 (sd 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 842 - 845
1 Aug 2000
Wroblewski BM Siney PD Fleming PA Bobak P

The calcar femorale is a vertical plate of bone lying deep to the lesser trochanter and is formed as a result of traction of the iliopsoas which separates the femoral cortex into two distinct layers, the calcar femorale and the medial femoral cortex. They fuse together proximally to form the medial femoral neck. A stem placed centrally will abut against the calcar femorale with little or no space for cement. Clearing of the calcar will offer space for a cement layer, which will support the stem proximally on the posterior aspect. We compared two consecutive groups of Charnley low-friction arthroplasties, with and without clearing of the calcar. In 330 patients who had an arthroplasty without clearing the calcar, there were ten revisions for aseptic loosening of the stem and six other stems were considered ‘definitely loose’, giving a rate of failure of 4.8%. In 111 patients in whom the calcar was cleared there was only one revision for aseptic loosening and no stems were classed as ‘definitely loose’, giving a rate of failure of 0.9%. Survivorship analysis has again shown the need for long-term follow-up; the differences became clear after ten years but because of the relatively small numbers, statistical analysis is not yet applicable. We now clear the calcar femorale routinely and advocate optimal access to the medullary canal and insertion of the stem in the area of the piriform fossa


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 415 - 425
1 Apr 2019
Thewlis D Bahl JS Fraysse F Curness K Arnold JB Taylor M Callary S Solomon LB

Aims

The purpose of this exploratory study was to investigate if the 24-hour activity profile (i.e. waking activities and sleep) objectively measured using wrist-worn accelerometry of patients scheduled for total hip arthroplasty (THA) improves postoperatively.

Patients and Methods

A total of 51 THA patients with a mean age of 64 years (24 to 87) were recruited from a single public hospital. All patients underwent THA using the same surgical approach with the same prosthesis type. The 24-hour activity profiles were captured using wrist-worn accelerometers preoperatively and at 2, 6, 12, and 26 weeks postoperatively. Patient-reported outcomes (Hip Disability and Osteoarthritis Outcome Score (HOOS)) were collected at all timepoints except two weeks postoperatively. Accelerometry data were used to quantify the intensity (sedentary, light, moderate, and vigorous activities) and frequency (bouts) of activity during the day and sleep efficiency. The analysis investigated changes with time and differences between Charnley class.


Bone & Joint 360
Vol. 8, Issue 1 | Pages 10 - 12
1 Feb 2019


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 573 - 581
1 May 2019
Almaguer AM Cichos KH McGwin Jr G Pearson JM Wilson B Ghanem ES

Aims

The purpose of this study was to compare outcomes of combined total joint arthroplasty (TJA) (total hip arthroplasty (THA) and total knee arthroplasty (TKA) performed during the same admission) versus bilateral THA, bilateral TKA, single THA, and single TKA. Combined TJAs performed on the same day were compared with those staged within the same admission episode.

Patients and Methods

Data from the National (Nationwide) Inpatient Sample recorded between 2005 and 2014 were used for this retrospective cohort study. Postoperative in-hospital complications, total costs, and discharge destination were reviewed. Logistic and linear regression were used to perform the statistical analyses. p-values less than 0.05 were considered statistically significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 609 - 615
1 Jul 1997
Gotoh E Inao S Okamoto T Ando M

We treated 31 consecutive patients of mean age 43 years (22 to 59) with severe osteoarthritis of the hip secondary to dysplasia by valgus-extension osteotomy. The clinical results were analysed for factors which may have affected the outcome. The procedure was carried out only on one side and was combined with a Chiari pelvic osteotomy in four patients. The angle of valgus was between 30 and 40° with 10 to 20° of extension. The mean follow-up was 15 years (12 to 18). Clinical evaluation using Charnley’s modification of the system of Merle d’Aubigné and Postel showed that the mean score for pain had improved from 2.3 before operation to 4.2 at 15 years, and function from 2.3 to 4.2. Range of movement had decreased from 4.2 to 3.5. Fifteen patients (48.4%) had a pain score of 5 or 6 and were evaluated as satisfactory. Kaplan-Meier survivorship analysis showed a survival rate of 51% at 15 years after operation. Two preoperative factors had a significant positive correlation with the radiological results, namely the thickness of the capital drop osteophyte and the length of the roof osteophyte. We suggest that this procedure is effective for advanced osteoarthritis in the dysplastic hip in young and active patients if these factors are satisfactory on the preoperative radiographs


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1157 - 1161
1 Sep 2018
Brown TS Fehring KA Ollivier M Mabry TM Hanssen AD Abdel MP

Aims

Recurrent infection following two-stage revision total hip arthroplasty (THA) for prosthetic joint infection (PJI) is a devastating complication. The purpose of this study was to report the survival of repeat two-stage revision hip arthroplasty, describe complications, and identify risk factors for failure.

Patients and Methods

We retrospectively identified 19 hips (19 patients) that had undergone repeat two-stage revision THA for infection between 2000 to 2013. There were seven female patients (37%) and the mean age was 60 years (30 to 85). Survival free from revision was assessed via Kaplan–Meier analysis. The patients were classified according to the Musculoskeletal Infection Society (MSIS) system, and risk factors for failure were identified. Mean follow-up was four years (2 to 11).


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 351 - 356
1 May 1995
Malkani A Settecerri J Sim F Chao E Wallrichs S

We reviewed retrospectively 50 consecutive total hip arthroplasties with proximal femoral replacement prostheses in 49 patients. All the patients had massive bone loss. There were 31 women and 18 men who had undergone a mean of 3.1 hip operations. At the last review, 15 patients had died and two had been lost to follow-up, so that 32 patients (33 hips) were available for assessment. The mean age of the patients at the time of the operation was 60.6 years. The mean length of clinical follow-up was 11.1 +/- 4 years, and mean radiographic follow-up was 7.6 +/- 3.2 years. The average preoperative Harris hip score was 46 +/- 13 points, which improved to 80 +/- 10 points after one year and to 76 +/- 16 points at the latest follow-up. The most frequent complication was dislocation, which occurred in 11 hips. Four femoral components and seven acetabular prostheses were revised because of aseptic loosening. With revision at the end point, survivorship after total hip arthroplasty with a proximal femoral replacement prosthesis was predicted to be 64% at 12 years. Although our preliminary results of hip salvage with a proximal femoral replacement prosthesis were encouraging, a longer follow-up has shown a higher rate of failure


Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives

The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic.

Methods

We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 435 - 442
1 Apr 2019
Zambianchi F Franceschi G Rivi E Banchelli F Marcovigi A Nardacchione R Ensini A Catani F

Aims

The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA).

Patients and Methods

Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as “good” and “bad” if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 303 - 310
1 Mar 2019
Kim S Lim Y Kwon S Jo W Heu J Kim Y

Aims

The purpose of this study was to examine whether leg-length discrepancy (LLD) following unilateral total hip arthroplasty (THA) affects the incidence of contralateral head collapse and subsequent THA in patients with bilateral osteonecrosis, and to determine factors associated with subsequent collapse.

Patients and Methods

We identified 121 patients with bilateral non-traumatic osteonecrosis who underwent THA between 2003 and 2011 to treat a symptomatic hip, and who also exhibited medium-to-large lesions (necrotic area ≥ 30%) in an otherwise asymptomatic non-operated hip. Of the 121 patients, 71 were male (59%) and 50 were female (41%), with a mean age of 51 years (19 to 71) at the time of initial THA. All patients were followed for at least five years and were assessed according to the presence of a LLD (non-LLD vs LLD group), as well as the LLD type (longer non-operated side vs shorter non-operated side group).


Bone & Joint Research
Vol. 8, Issue 2 | Pages 65 - 72
1 Feb 2019
Cowie RM Aiken SS Cooper JJ Jennings LM

Objectives

Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation.

Methods

A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).


Bone & Joint 360
Vol. 8, Issue 1 | Pages 13 - 16
1 Feb 2019