Advertisement for orthosearch.org.uk
Results 541 - 560 of 796
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius.

We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs).

The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs).

The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques.

However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed.

Cite this article: Bone Joint J 2015;97-B:1370–6.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 35 - 37
1 Jun 2017


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 563 - 565
1 May 2017
Perry DC Griffin XL Dritsaki M Costa ML Parsons N


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 221 - 228
1 Feb 2015
Zhang X Li Y Wen S Zhu H Shao X Yu Y

We report a new surgical technique of open carpal tunnel release with subneural reconstruction of the transverse carpal ligament and compare this with isolated open and endoscopic carpal tunnel release.

Between December 2007 and October 2011, 213 patients with carpal tunnel syndrome (70 male, 143 female; mean age 45.6 years; 29 to 67) were recruited from three different centres and were randomly allocated to three groups: group A, open carpal tunnel release with subneural reconstruction of the transverse carpal ligament (n = 68); group B, isolated open carpal tunnel release (n = 92); and group C, endoscopic carpal tunnel release (n = 53).

At a mean final follow-up of 24 months (22 to 26), we found no significant difference between the groups in terms of severity of symptoms or lateral grip strength. Compared with groups B and C, group A had significantly better functional status, cylindrical grip strength and pinch grip strength. There were significant differences in Michigan Hand Outcome scores between groups A and B, A and C, and B and C. Group A had the best functional status, cylindrical grip strength, pinch grip strength and Michigan Hand Outcome score.

Subneural reconstruction of the transverse carpal ligament during carpal tunnel decompression maximises hand strength by stabilising the transverse carpal arch.

Cite this article: Bone Joint J 2015;97-B:221–8


Bone & Joint 360
Vol. 6, Issue 1 | Pages 45 - 45
1 Feb 2017


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius.

The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care.

There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000.

Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits.

Cite this article: Bone Joint J 2015;97-B:1082–9.


Bone & Joint Research
Vol. 6, Issue 7 | Pages 423 - 432
1 Jul 2017
van der Stok J Hartholt KA Schoenmakers DAL Arts JJC

Objectives

The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery.

Methods

A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.


Bone & Joint Research
Vol. 6, Issue 5 | Pages 323 - 330
1 May 2017
Pijls BG Sanders IMJG Kuijper EJ Nelissen RGHH

Objectives

Infection of implants is a major problem in elective and trauma surgery. Heating is an effective way to reduce the bacterial load in food preparation, and studies on hyperthermia treatment for cancer have shown that it is possible to heat metal objects with pulsed electromagnetic fields selectively (PEMF), also known as induction heating. We therefore set out to answer the following research question: is non-contact induction heating of metallic implants effective in reducing bacterial load in vitro?

Methods

Titanium alloy cylinders (Ti6Al4V) were exposed to PEMF from an induction heater with maximum 2000 watts at 27 kHz after being contaminated with five different types of micro-organisms: Staphylococcus epidermidis; Staphylococcus aureus; Pseudomonas aeruginosa; spore-forming Bacillus cereus; and yeast Candida albicans. The cylinders were exposed to incremental target temperatures (35°C, 45°C, 50°C, 55°C, 60°C, 65°C, 70°C) for up to 3.5 minutes.


Bone & Joint 360
Vol. 5, Issue 2 | Pages 31 - 33
1 Apr 2016


Bone & Joint 360
Vol. 5, Issue 6 | Pages 46 - 46
1 Dec 2016


Bone & Joint 360
Vol. 6, Issue 1 | Pages 26 - 29
1 Feb 2017



The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 147 - 150
1 Feb 2017
Costa ML Tutton E Achten J Grant R Slowther AM

Traditionally, informed consent for clinical research involves the patient reading an approved Participant Information Sheet, considering the information presented and having as much time as they need to discuss the study information with their friends and relatives, their clinical care and the research teams. This system works well in the ‘planned’ or ‘elective’ setting. But what happens if the patient requires urgent treatment for an injury or emergency?

This article reviews the legal framework which governs informed consent in the emergency setting, discusses how the approach taken may vary according to the details of the emergency and the treatment required, and reports on the patients’ view of providing consent following a serious injury. We then provide some practical tips for managing the process of informed consent in the context of injuries and emergencies.

Cite this article: Bone Joint J 2017;99-B:147–150.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 32 - 34
1 Dec 2016


Bone & Joint 360
Vol. 5, Issue 6 | Pages 37 - 39
1 Dec 2016


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 218 - 223
1 Feb 2016
Scalise J Jaczynski A Jacofsky M

Aims

The eccentric glenosphere was principally introduced into reverse shoulder arthroplasty to reduce the incidence of scapular notching. There is only limited information about the influence of its design on deltoid power and joint reaction forces.

The aim of our study was to investigate how the diameter and eccentricity of the glenosphere affect the biomechanics of the deltoid and the resultant joint reaction forces.

Methods

Different sizes of glenosphere and eccentricity were serially tested in ten cadaveric shoulders using a custom shoulder movement simulator.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1070 - 1076
1 Aug 2014
Hannemann PFW van Wezenbeek MR Kolkman KA Twiss ELL Berghmans CHJ Dirven PAMGM Brink PRG Poeze M

We hypothesised that the use of pulsed electromagnetic field (PEMF) bone growth stimulation in acute scaphoid fractures would significantly shorten the time to union and reduce the number of nonunions in a randomised, double-blind, placebo-controlled multicentre trial. A total of 102 patients (78 male, 24 female; mean age 35 years (18 to 77)) from five different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly allocated to PEMF (n = 51) or placebo (n = 51) and assessed with regard to functional and radiological outcomes (multiplanar reconstructed CT scans) at 6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing did not differ significantly between the active PEMF group and the placebo group. We concluded that the addition of PEMF bone growth stimulation to the conservative treatment of acute scaphoid fractures does not accelerate bone healing.

Cite this article: Bone Joint J 2014; 96-B:1070–6.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 237 - 244
1 Feb 2017
Vegt AEVD Grond R Grüschke JS Boomsma MF Emmelot CH Dijkstra PU Sluis CKVD

Aims

The aim of this study was to compare the Push Ortho Thumb Brace CMC and a custom-made orthosis in the treatment of patients with primary osteoarthritis of the carpometacarpal joint of the thumb. Our outcome measures were pain scores, tests of hand function, patient satisfaction and patient preference.

Patients and Methods

A multicentre crossover randomised controlled trial was conducted which included 63 patients (44 women) with primary osteoarthritis of the carpometacarpal joint of the thumb. Of these, 59 patients with a mean age of 60.1 years (standard deviation 8.2), completed the study. Patients used both orthoses for two weeks with a two-week washout period in-between. Pain was measured on a 10-cm visual analogue scale. Hand function was assessed using the Jebsen Taylor Hand Function test, Nine Hole Peg Test, key grip, pinch grip and Functional Index for Hand Osteoarthritis. Patient preference was assessed using the Dutch version of the Quebec User Evaluation of Satisfaction with Assistive Technology score.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 383 - 392
1 Mar 2017
Handoll HH Keding A Corbacho B Brealey SD Hewitt C Rangan A

Aims

The PROximal Fracture of the Humerus Evaluation by Randomisation (PROFHER) randomised clinical trial compared the operative and non-operative treatment of adults with a displaced fracture of the proximal humerus involving the surgical neck. The aim of this study was to determine the long-term treatment effects beyond the two-year follow-up.

Patients and Methods

Of the original 250 trial participants, 176 consented to extended follow-up and were sent postal questionnaires at three, four and five years after recruitment to the trial. The Oxford Shoulder Score (OSS; the primary outcome), EuroQol 5D-3L (EQ-5D-3L), and any recent shoulder operations and fracture data were collected. Statistical and economic analyses, consistent with those of the main trial were applied.