Advertisement for orthosearch.org.uk
Results 541 - 560 of 968
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 497 - 503
1 May 2002
Hedström M åström K Sjöberg H Dalén N Sjöberg K Brosjö E

A total of 63 women who had an operation for a fracture of the hip was randomly allocated to one year of treatment either with anabolic steroids, vitamin D and calcium (anabolic group) or with calcium only (control group). The thigh muscle volume was measured by quantitative CT. The bone mineral density of the hip, femur and tibia was assessed by quantitative CT and dual-energy x-ray absorptiometry and of the heel by quantitative ultrasound. Quantitative CT showed that the anabolic group did not lose muscle volume during the first 12 months whereas the control group did (p< 0.01). There was less bone loss in the proximal tibia in the anabolic group than in the control group. The speed of gait and the Harris hip score were significantly better in the anabolic group after six and 12 months. Anabolic steroids, even in this moderate dose, given in combination with vitamin D and calcium had a beneficial effect on muscle volume, bone mineral density and clinical function in this group of elderly women


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 624 - 629
1 Jul 1993
Jacobsson S Djerf K Gillquist J Hammerby S Ivarsson I

We compared two cementless femoral components, the 'isoelastic' Butel stem and the more rigid PCA design, in a randomised, prospective study of 56 patients with a mean follow-up of 4 years (2 to 5). Patients were matched in 28 pairs, and one of each pair was treated with each femoral component. The isoelastic stem gave fewer signs of stress shielding radiologically, but both the Harris hip score and the visual analogue pain scale showed significantly inferior results at the two-year and three-year follow-up. The overall failure rates for the femoral components were 43% for the Butel and 11% for the PCA. These results contrast with those of earlier experimental and clinical studies, in which isoelastic properties appeared to be advantageous. This review emphasises the importance of controlled studies before an altered or new design of prosthesis is released on to the market for general use


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 303 - 310
1 Mar 2019
Kim S Lim Y Kwon S Jo W Heu J Kim Y

Aims

The purpose of this study was to examine whether leg-length discrepancy (LLD) following unilateral total hip arthroplasty (THA) affects the incidence of contralateral head collapse and subsequent THA in patients with bilateral osteonecrosis, and to determine factors associated with subsequent collapse.

Patients and Methods

We identified 121 patients with bilateral non-traumatic osteonecrosis who underwent THA between 2003 and 2011 to treat a symptomatic hip, and who also exhibited medium-to-large lesions (necrotic area ≥ 30%) in an otherwise asymptomatic non-operated hip. Of the 121 patients, 71 were male (59%) and 50 were female (41%), with a mean age of 51 years (19 to 71) at the time of initial THA. All patients were followed for at least five years and were assessed according to the presence of a LLD (non-LLD vs LLD group), as well as the LLD type (longer non-operated side vs shorter non-operated side group).


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 212 - 216
1 Mar 1990
Eskola A Santavirta S Konttinen Y Hoikka V Tallroth K Lindholm T

In 16 patients we used uncemented Lord prostheses at revision operations for aggressive granulomatosis after cemented hip arthroplasties; in 12 bone grafts also were used. In 13 hips the granulomatous lesions were multifocal, and in one the acetabular component was involved. There was no evidence of infection in any case: all the patients had normal ESR and CRP levels. The revision operation was performed on average 9.4 years after the primary replacement; the mean age at revision was 64 years. On radiographs, the bone around the prosthesis had consolidated by an average of 16 months. At follow-up, two to six years later (mean 3.5 years) there had been no recurrences, nine patients had an excellent Mayo hip score, five were good and two fair


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 548 - 554
1 May 2000
Bankes MJK Catterall A Hashemi-Nejad A

Valgus extension osteotomy (VGEO) is a salvage procedure for ‘hinge abduction’ in Perthes’ disease. The indications for its use are pain and fixed deformity. Our study shows the clinical results at maturity of VGEO carried out in 48 children (51 hips) and the factors which influence subsequent remodelling of the hip. After a mean follow-up of ten years, total hip replacement has been carried out in four patients and arthrodesis in one. The average Iowa Hip Score in the remainder was 86 (54 to 100). Favourable remodelling of the femoral head was seen in 12 hips. This was associated with three factors at surgery; younger age (p = 0.009), the phase of reossification (p = 0.05) and an open triradiate cartilage (p = 0.0007). Our study has shown that, in the short term, VGEO relieves pain and corrects deformity; as growth proceeds it may produce useful remodelling in this worst affected subgroup of children with Perthes’ disease


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 213 - 216
1 Mar 1996
Alexeeff M Mahomed N Morsi E Garbuz D Gross A Latner AJ

We report 11 patients having revision of total hip arthroplasty using massive structural allografts for failure due to sepsis and associated bone loss. All patients had a two-stage reconstruction and the mean follow-up was 47.8 months (24 to 72). Positive cultures were obtained at the first stage in nine of the 11 patients, with Staphylococcus epidermidis being the most common organism. The other two patients had draining sinuses with negative cultures. There was no recurrence of infection in any patient. The mean increase in the modified Harris hip score was 45 and all the grafts appeared to have united to host bone. Two patients required additional procedures, but only one was related to the allograft. Complications included an incomplete sciatic nerve palsy and one case of graft resorption. Our results support the use of massive allografts in failed septic hip arthroplasty in which there is associated bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 185 - 190
1 Mar 1996
Dawson J Fitzpatrick R Carr A Murray D

We developed a 12-item questionnaire for completion by patients having total hip replacement (THR). A prospective study of 220 patients was undertaken before operation and at follow-up six months later. Each completed the new questionnaire as well as the SF36, and some the Arthritis Impact Measurement Scales (AIMS). An orthopaedic surgeon assessed the Charnley hip score. The single score derived from the questionnaire had a high internal consistency. Reproducibility was examined by test-retest reliability and was found to be satisfactory. The validity of the questionnaire was established by obtaining significant correlation in the expected direction with the Charnley scores and relevant scales of the SF36 and the AIMS. Sensitivity to change was assessed by analysing the differences between the preoperative scores and those at the follow-up. The standardised effect size for the new questionnaire compared favourably with that for the SF36 and the AIMS. The new questionnaire provides a measure of outcome for THR which is short, practical, reliable, valid and sensitive to clinically important changes


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 536 - 539
1 May 2019
Cassidy RS O hEireamhoin S Beverland DE

Aims

The aim of this retrospective audit was to determine the route of referral or presentation of patients requiring revision following primary total hip arthroplasty (THA).

Patients and Methods

A total of 4802 patients were implanted with an Orthopaedic Data Evaluation Panel (ODEP) 10A* cementless implant (Corail/Pinnacle) between 2005 and 2015; 80 patients with a mean age of 67.8 years (sd 10.8) underwent a subsequent revision. The primary outcome measure was route of referral for revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 191 - 198
1 Mar 2003
Hasegawa Y Sakano S Iwase T Iwasada S Torii S Iwata H

Segmental collapse occurs in the early stage of a vascular necrosis (AVN) of the femoral head, and is associated with a poor prognosis. Since it develops at a relatively young age, the long-term outcome after total hip replacement is a major concern. We have compared the long-term results of pedicle bone grafting (PBG) with those of transtrochanteric rotational osteotomy (TRO). In the PBG group there were 23 men (27 hips) and three women (4 hips) with a mean age at the time of surgery of 38 years and a mean follow-up of 13 years. In the TRO group there were 44 men (55 hips) and 19 women (22 hips) with a mean age at the time of surgery of 39 years and a mean follow-up of seven years. Failure was defined as a need for total hip replacement or a Harris hip score below 70. The long-term results were similar for the two groups. The survival rates at five and ten years were 85% and 67%, respectively, in the PBG group, and 71% and 61%, respectively, in the TRO group, according to Kaplan-Meier survivorship analysis. In the TRO group patients in stage II had significantly better results that those in stage III


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 814 - 821
1 Nov 1992
Pellegrini V Hughes S Evarts C

We implanted 57 uncemented cobalt-chrome porous-coated collarless femoral components into 51 patients (mean age 49 years). At review, five to eight years postoperatively, good or excellent results were recorded in 70% by the Mayo Clinic hip evaluation and in 84% by the Harris hip score. Revision for aseptic loosening of the femoral stem was necessary in only one hip. Thigh pain diminished with time and was present in only two hips at the time of review. Endosteal bone formation was seen at the junction of the smooth and the porous segments of the stem in 94% of hips and in 60% it continued after three years. In 90% of hips, proximal femoral atrophy did not progress after three years. Discontinuous radiolucent lines were seen around 30% of stems, most commonly in zones I, IV and VII. They were not progressive in 94% and their presence did not correlate with the clinical outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 177 - 184
1 Mar 2004
Daniel J Pynsent PB McMinn DJW

The results of conventional hip replacement in young patients with osteoarthritis have not been encouraging even with improvements in the techniques of fixation and in the bearing surfaces. Modern metal-on-metal hip resurfacing was introduced as a less invasive method of joint reconstruction for this particular group. This is a series of 446 hip resurfacings (384 patients) performed by one of the authors (DJWM) using cemented femoral components and hydroxyapatite-coated uncemented acetabular components with a maximum follow-up of 8.2 years (mean 3.3). Their survival rate, Oxford hip scores and activity levels are reviewed. Six patients died due to unrelated causes. There was one revision (0.02%) out of 440 hips. The mean Oxford score of the surviving 439 hips is 13.5. None of the patients were told to change their activities at work or leisure; 31% of the men with unilateral resurfacings and 28% with bilateral resurfacings were involved in jobs that they considered heavy or moderately heavy; 92% of men with unilateral hip resurfacings and 87% of the whole group participate in leisure-time sporting activity. The extremely low rate of failure in spite of the resumption of high level occupational and leisure activities provides early evidence of the suitability of this procedure for young and active patients with arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 564 - 568
1 Jul 1991
Kershaw C Atkins R Dodd C Bulstrode C

The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sepsis, two for persistent pain, and one each for fracture and recurrent dislocation. A further six hips were radiologically and symptomatically loose. Pain was mild or absent in 83%. Over half were able to walk a mile or more; 70% flexed more than 70 degrees; 15% had a flexion deformity, but in only 7% was this more than 10 degrees. The mean Harris hip score was 74. Survival at five years was 95% and at 10 years, 77%


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 430 - 433
1 May 1991
Fredin H Sanzen L Sigurdsson B Unander-Scharin L

Total arthroplasty was performed on 21 congenitally dislocated hips in 18 women. In all cases the femoral head was dislocated cranially at least one-fifth of the height of the pelvis. The components were both cemented, the acetabulum being replaced to its original position. The acetabular roof was reconstructed by bone graft in 13 hips, and trochanteric osteotomy was done in 18 hips. The patients were assessed at a median follow-up time of 7.5 years when their median age was 54 years. Nine patients had been revised or required revision. At follow-up the average functional score (according to Charnley) was 6 for pain, 4 for walking ability and 5 for range of motion. The Harris hip score was 82. The patients' subjective evaluation of their satisfaction with the late results on a visual analogue scale was 93, range 23 to 100. The high loosening rate in such patients demands regular follow-up and preparedness for revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 2 - 8
1 Jan 1990
Haddad R Cook S Brinker M

We reviewed 134 primary noncemented porous-coated total hip replacements in 125 patients: 64 were DePuy AML prostheses, 20 were Howmedica PCA and 50 were Implant Technology LSF. The prostheses had been in situ for an average of 36 months, 40 months and 24 months respectively. The average pre-operative Harris hip scores were 38.2 for AML, 33.2 for PCA, and 41.0 for the LSF prostheses. The average postoperative scores were 80.7 for AML, 83.8 for the PCA, and 91.5 for LSF. Thigh or groin pain associated with the prosthesis was present in 30% of AML, 30% PCA and 8% of the LSF cases. The clinical and radiographic review showed better early results with the LSF prostheses than the others; this seemed to be related to the implant design, which provided improved initial stability and more physiological transfer of load


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 969 - 974
1 Sep 2003
Drescher W Fürst M Hahne HJ Helfenstein A Petersen W Hassenpflug J

The treatment of osteonecrosis of the femoral head (FHN) is controversial. It mainly occurs in young patients in whom total hip replacement is best avoided because of an increased risk of revision. The objective of this long-term follow-up study was to evaluate the outcome of intertrochanteric flexion osteotomy as a hip joint preserving operation for FHN. Over a 19-year period we carried out 70 intertrochanteric flexion osteotomies for FHN in 64 patients. The mean follow-up was 10.4 years (3.0 to 20.3). The overall mean Harris hip score increased from 51 points preoperatively to 71 points postoperatively. Six patients (9%) developed early postoperative complications. A total of 19 hips (27%) underwent total hip arthroplasty at a mean of 8.7 years after osteotomy. The five-year survival rate was 90%. Survival rates of hips in Ficat stage 2 were higher than those in stages 3 or 4. Hips with a preoperative necrotic angle of < 200° had a better survival probability than those with a necrotic angle > 200°. Our findings suggest that flexion osteotomy is a safe and effective procedure in Ficat stage 2 and 3 FHN, preferably with a necrotic angle of < 200°


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 229 - 234
1 Mar 1994
Wright J Rudicel S Feinstein A

We aimed to assess individual differences in complaints in patients just before total hip replacement (THR) and the importance attached to the relief of each of them. In a pilot study, using open-ended interviews, we identified 16 main complaints, four of which (night pain, unequal leg length and discomfort during sexual and recreational activities) were not included in any of the six hip-rating scales in general use. Each of the 16 complaints was then assessed in 72 patients and rated for severity and the relative importance of relief. From this we calculated a severity-importance rating for each complaint and a patient-specific score for all complaints. The 72 patients had a mean age of 64 years (17 to 92) and 51% were men. The most important reasons for wanting a THR were day pain and walking difficulty, but the complaints mentioned above and not included in standard hip scores were also important. Greater attention to the individual requirements of patients might improve evaluation of the outcome of orthopaedic treatments


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 209 - 214
1 Mar 2003
Aldinger PR Breusch SJ Lukoschek M Mau H Ewerbeck V Thomsen M

We followed the first 354 consecutive implantations of a cementless, double-tapered straight femoral stem in 326 patients. Follow-up was at a mean of 12 years (10 to 15). The mean age of the patients was 57 years (13 to 81). At follow-up, 56 patients (59 hips) had died, and eight (eight hips) had been lost to follow-up. Twenty-five hips underwent femoral revision, eight for infection, three for periprosthetic fracture and 14 for aseptic loosening. The overall survival was 92% at 12 years (95% CI 88 to 95). Survival with femoral revision for aseptic loosening as an endpoint was 95% (95% CI 92 to 98). The median Harris hip score at follow-up was 84 points (23 to 100). Radiolucent lines (< 2 mm) in Gruen zones 1 and 7 were present in 38 (16%) and 34 hips (14%), respectively. Radiolucencies in zones 2 to 6 were found in five hips (2%). The results for mid- to long-term survival with this femoral component are encouraging and compare with those achieved in primary cemented total hip arthroplasty. The high rate of loosening of the cup and the high rate of pain are, however, a source of concern


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 214 - 217
1 Mar 1985
Taine W Armour P

The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 83 - 89
1 Jan 2001
Koo K Song H Yang J Yang P Kim J Kim Y

The rate of success of transtrochanteric rotational osteotomy for osteonecrosis of the femoral head may be improved if patients are preselected using MRI. We have used three criteria for selection for osteotomy (i) minor collapse of the infarcted area, loss of congruity or the crescent sign, without narrowing of the joint space or acetabular involvement (ii) patients younger than 55 years and with a painful hip (iii) patients with an intact area constituting an arc of more than 120° between the central vertical line of the femoral head and the posterior or anterior margin of the necrotic portion as seen on a midsagittal MRI. Seventeen patients were selected, with a follow-up of more than 42 months. A bone scan four weeks after operation showed adequate perfusion of the proximal segment in all hips. The hip score of Merle d’Aubigné et al improved from 13.5 points before operation to 17.2 points at the latest follow-up. Further collapse of the femoral head did not occur. The use of MRI instead of plain radiographs for the selection of patients has improved the success rate of transtrochanteric rotational osteotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 74 - 77
1 Jan 1996
Norman-Taylor FH Palmer CR Villar RN

Total hip and total knee arthroplasty both provide a considerable improvement in quality of life, but there is no evidence to suggest that one is more successful than the other. We studied 72 patients in a prospective trial before and after total hip or total knee replacement. We recorded scores for disability and distress derived from the Harris hip score and the British Orthopaedic Association knee assessment score, and used them to generate quality of life (QoL) scores using the Rosser Index Matrix immediately before and at one year after surgery. The patients awaiting knee replacement had significantly lower QoL scores than those awaiting hip replacement (p = 0.011). The QoL scores at one year were high and almost identical for both groups (p = 0.46). Further analysis showed that gender and weight were not significant predictors of improvement of QoL scores, but age (p = 0.03) and whether the hip or knee was replaced (p = 0.006) were significant factors