In arthritis of the varus knee, a high tibial
osteotomy (HTO) redistributes load from the diseased medial compartment
to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women)
with 42 varus, arthritic knees who underwent HTO and dynamic correction
using a Garches external fixator until they felt that normal alignment
had been restored. The mean age of the patients was 54.11 years
(34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3
to 10) post-operatively. Radiographs, gait analysis and visual analogue
scores for pain were measured pre- and post-operatively, at one
year and at medium-term follow-up (mean six years; 2 to 10). Failure
was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal
groups with high (17 patients) or low (19 patients) adductor moments.
After correction, a statistically significant (p <
0.001, At final follow-up, after a mean of 15.9 years (12 to 20), there
was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of
adductor moment group, with a mean time to conversion to knee arthroplasty
of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment
of medial compartment osteoarthritis of the knee but does not last
in the long-term. Cite this article:
Although infrequent, a fracture of the cuboid can lead to significant
disruption of the integrity of the midfoot and its function. The
purpose of this study was to classify the pattern of fractures of
the cuboid, relate them to the mechanism of injury and suggest methods
of managing them. We performed a retrospective review of patients with radiologically
reported cuboid fractures. Fractures were grouped according to commonly
occurring patterns of injury. A total of 192 fractures in 188 patients
were included. They were classified into five patterns of injury.Aims
Patients and Methods
Rib fracture fixation by orthopaedic and cardiothoracic surgeons has become increasingly popular for the treatment of chest injuries in trauma. The literature, though mainly limited to Level II and III evidence, shows favourable results for operative fixation. In this paper we review the literature and discuss the indications for rib fracture fixation, surgical approaches, choice of implants and the future direction for management. With the advent of NICE guidance and new British Orthopaedic Association Standards for Trauma (BOAST) guidelines in production, the management of rib fractures is going to become more and more commonplace.
The mainstay of surgical correction of hallux valgus is first
metatarsal osteotomy, either proximally or distally. We present
a technique of combining a distal chevron osteotomy with a proximal
opening wedge osteotomy, for the correction of moderate to severe
hallux valgus. We reviewed 45 patients (49 feet) who had undergone double osteotomy.
Outcome was assessed using the American Orthopaedic Foot and Ankle
Society (AOFAS) and the Short Form (SF) -36 Health Survey scores.
Radiological measurements were undertaken to assess the correction. The mean age of the patients was 60.8 years (44.2 to 75.3). The
mean follow-up was 35.4 months (24 to 51).Aims
Patients and Methods
Our aim was to determine whether, based on the current literature,
bariatric surgery prior to total hip (THA) or total knee arthroplasty
(TKA) reduces the complication rates and improves the outcome following
arthroplasty in obese patients. A systematic literature search was undertaken of published and
unpublished databases on the 5 November 2015. All papers reporting
studies comparing obese patients who had undergone bariatric surgery
prior to arthroplasty, or not, were included. Each study was assessed
using the Downs and Black appraisal tool. A meta-analysis of risk ratios
(RR) and 95% confidence intervals (CI) was performed to determine
the incidence of complications including wound infection, deep vein
thrombosis (DVT), pulmonary embolism (PE), revision surgery and
mortality.Aims
Methods
Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and post-operative version and inclination of the glenoid were
measured on CT scans, using 3D planning automatic software. During
surgery, a congruent 3D-printed PSG was applied onto the glenoid
surface, thus determining the entry point and orientation of the
central guide wire used for reaming the glenoid and the introduction
of the component. Manual segmentation was performed on post-operative
CT scans to compare the planned and the actual position of the entry
point (mm) and orientation of the component (°).Aims
Patients and Methods
This study compared the long-term results following Salter osteotomy
and Pemberton acetabuloplasty in children with developmental dysplasia
of the hip (DDH). We assessed if there was a greater increase in
pelvic height following the Salter osteotomy, and if this had a
continued effect on pelvic tilt, lumbar curvature or functional outcomes. We reviewed 42 children at more than ten years post-operatively
following a unilateral Salter osteotomy or Pemberton acetabuloplasty.
We measured the increase in pelvic height and the iliac crest tilt
and sacral tilt at the most recent review and at an earlier review
point in the first decade of follow-up. We measured the lumbar Cobb angle
and the Short Form-36 (SF-36) and Harris hip scores were collected
at the most recent review.Aims
Patients and Methods
Patients with osteoarthritis of the knee commonly have degenerative
meniscal tears. Arthroscopic meniscectomy is frequently performed,
although the benefits are debatable. Recent studies have concluded
that there is no role for arthroscopic washout in osteoarthritis
of the knee. Our aim was to perform a systematic review to assess
the evidence for the efficacy of arthroscopic meniscectomy in patients
with meniscal tears and degenerative changes in the knee. A literature search was performed, using the PubMed/MEDLINE database,
for relevant articles published between 1975 and 2015. A total of
six studies, including five randomised controlled trials and one
cross-sectional study of a prospective cohort, met the inclusion
criteria. Relevant information including study design, operations,
the characteristics of the patients, outcomes, adverse events and
further operations were extracted.Aims
Patients and Methods
This prospective randomised controlled trial was designed to
evaluate the outcome of both the MRI- and CT-based patient-specific
matched guides (PSG) from the same manufacturer. A total of 137 knees in 137 patients (50 men, 87 women) were
included, 67 in the MRI- and 70 in the CT-based PSG group. Their
mean age was 68.4 years (47.0 to 88.9). Outcome was expressed as
the biomechanical limb alignment (centre hip-knee-ankle: HKA-axis)
achieved post-operatively, the position of the individual components
within 3° of the pre-operatively planned alignment, correct planned
implant size and operative data (e.g. operating time and blood loss).Aims
Patients and Methods
Until now, there has been no consensus as to whether stemmed
acetabular components are appropriate for use in patients undergoing
revision total hip arthroplasty (THA) who have major acetabular
defects or pelvic discontinuity. We wished to address this deficiency
in the literature. We carried out a retrospective study of 35 patients (six men
and 29 women) with a mean age of 68 years (37 to 87), with major
acetabular defects who underwent revision THA between 2000 and 2012.Aim
Patients and Methods
To investigate the longevity of uncemented fixation of a femoral
component in total hip arthroplasty (THA) in patients with Dorr
type C proximal femoral morphology. A total of 350 consecutive uncemented THA in 320 patients were
performed between 1983 and 1987, by a single surgeon using the Taperloc
femoral component. The 63 patients (68 hips) with Dorr type C proximal
femoral morphology were the focus of this review. The mean age of
the patients was 69 years (24 to 88) and mean follow-up was 16.6
years (ten to 29). Survival analysis included eight patients (eight
hips) who died without undergoing revision surgery prior to obtaining
ten years follow-up. All 55 surviving patients (60 hips) were available
for clinical assessment and radiographic review. As a comparator
group, the survival and implant fixation in the remaining 282 THAs
(257 patients) with Dorr type A and B morphology were evaluated.
The mean age of these patients was 52 years (20 to 82).Aims
Patients and Methods
We review our experience of Coonrad-Morrey total elbow arthroplasty
(TEA) for fractures of the distal humerus in non-rheumatoid patients
with a minimum of ten years follow-up. TEA through a triceps splitting approach was peformed in 37 non-rheumatoid
patients for a fracture of the distal humerus between 1996 and 2004.
One patient could not be traced and 17 had died before the tenth
anniversary of their surgery. This left 19 patients with a minimum
follow-up of ten years to form the study group. Of these, 13 patients
were alive at the time of final review. The other six had died,
but after the tenth anniversary of their elbow arthroplasty. Their
clinical and radiological data were included in the study. Aims
Patients and Methods