Advertisement for orthosearch.org.uk
Results 501 - 520 of 1199
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 783 - 786
1 Sep 1996
Pech J Sosna A Rybka V Pokorný D

Arthrodesis of the wrist is a standard operation which is indicated for severe rheumatoid arthritis in which destruction is too advanced for more conservative procedures, or after failure of previous surgery. We have developed an L-shaped plate designed for this purpose. It provides rigid internal fixation with the wrist in the neutral position and utilises bone grafts obtained from the distal ulna and the carpal bones. We have carried out 29 successful fusions between 1992 and 1995. In all 29 patients synovectomy and resection of the head of the ulna were performed; 11 also had reconstruction of ruptured extensor tendons. All the patients obtained bony union, pain relief and improved function


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 129 - 131
1 Jan 1990
Lee E Goh J Helm R Pho R

Ten adults were studied two to seven years after resection of a fibula for use as a free vascularised bone graft. Six had no symptoms in the donor leg, four had some aching, weakness or paraesthesia and three had definite weakness of the long toe flexors and extensors. All knees and ankles were clinically and radiologically stable, but the distal fibular remnant was osteoporotic in nine patients. Gait analysis of the donor leg and the contralateral normal leg showed definite differences, which could be attributed to weakness of the deep muscles caused by loss of their normal origin and to the change in load transmission through the fibula


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 561 - 565
1 Aug 1986
Pritchett J

Deformity of the forearm is common in patients with hereditary multiple exostoses, producing cosmetic and functional impairment in which shortening of the ulna is a significant factor. The results of ulnar lengthening in 10 forearms of eight patients are reported. Lengthening was performed by osteotomy of the shaft followed immediately by a bone graft and internal fixation, or by gradual distraction with an external fixator. In all patients the appearance was improved and the range of radial deviation at the wrist was increased. In most patients forearm movement and radial head stability were improved. Partial recurrence of the deformity was seen during the follow-up of skeletally immature patients, but in general ulnar lengthening was found to be a useful operation


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 205 - 210
1 Mar 2002
Toh S Narita S Arai K Nakashima K Tsubo K

The clinical results of 26 digits (18 patients) lengthened by distraction callotasis were evaluated and the factors which influenced healing were analysed. There were 14 men and four women, with a mean age of 39 years. All digits had suffered traumatic amputation. There were eight thumbs and 18 fingers. The level of the site of the osteotomy was at the proximal metaphysis in ten, the middle diaphysis in 13 and the distal metaphysis in three. Although the proposed length was achieved in 23 of the 26 digits, five required additional bone grafts. The rate of healing was 96 days/cm in the digits without complications such as callus fracture or poor callus formation, and 158 days/cm in those with complications. Lengthening at the proximal metaphysis gave a better result than at the diaphysis or distal metaphysis


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 257 - 260
1 Mar 1992
Mont M Maar D Krackow K Hungerford D

Retrospective review of 730 consecutive primary uncemented and cemented total hip arthroplasties revealed 19 intra-operative hoop-stress fractures of the femoral neck. These were incomplete, linear, and minimally displaced. Management was by cerclage wiring (12), bone graft and cerclage (two), further impaction (two), and the use of cement (three), with no change from our standard postoperative management and rehabilitation. Eighteen patients had excellent or good results with an average Harris hip score of 93. Radiographically, all but one patient had Engh stability-fixation scores consistent with stable bone ingrowth. We conclude that hoop-stress fractures of the proximal femur, properly managed, do not detract from the results of total hip arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1073 - 1075
1 Nov 1990
Fern E Stockley I Bell M

Five patients with Boyd type II congenital pseudarthrosis of the tibia underwent excision of the pseudarthrosis and double onlay bone grafting. Stability was maintained by extending intramedullary rods. Clinical union was achieved in all cases at a mean of 8.6 months (range six to 11). The rods extended by 15.7% (range 2% to 31.4%) as growth occurred. One rod was removed because of infection and a vascularised free fibular graft was subsequently performed. The extending rods provided stability while union occurred and did not require revision as the legs grew. The rods can be removed easily and have not jeopardized further surgical options


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 605 - 611
1 Jul 1990
Court-Brown C Christie J McQueen M

We present the results of using the Grosse-Kempf interlocking nail in the management of 125 closed and type I open tibial fractures. The mean time to union was 16.7 weeks and no fracture required bone grafting. Mobilisation of the patient and the range of joint movement were better than with other methods of treating tibial fractures. There was a 1.6% incidence of infection; 40.8% of patients had knee pain and 26.4% needed to have the nail removed. Other complaints were minor. We suggest that closed intramedullary nailing with an interlocking nail system is an excellent method of treating closed and type I open tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 266 - 267
1 Mar 1986
Baciu C

We report the results of a simple technique of ankle arthrodesis which is, however, indicated only when the foot can be reduced manually to a functional position. A special milling-cutter with an expulsion piston is used to obtain a cylindrical bone graft which is reintroduced having been reversed from left to right and rotated through 90 degrees. The operation is simple and very rapid. It has been performed on 72 patients, 62 of whom have been followed up for an average of six years. Fifty-seven were painless with bony fusion in a functional position; one was solid and painless but in valgus. In only four patients were the results unsatisfactory


Bone & Joint 360
Vol. 8, Issue 3 | Pages 11 - 13
1 Jun 2019


Bone & Joint 360
Vol. 7, Issue 5 | Pages 30 - 33
1 Oct 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 68 - 73
1 Jan 2003
Keating JF Hajducka CL Harper J

We used calcium-phosphate cement combined with minimal internal fixation to treat 49 fractures of the lateral tibial plateau. There were 25 split depression fractures, 22 pure depression fractures and two bicondylar fractures. Anatomical reduction was obtained in 38 fractures, satisfactory reduction in nine and imperfect reduction in two. Of 44 patients reviewed at one year, 33 were rated as having an excellent reduction. Functional outcome as measured by the Rasmussen score was good or excellent at six months in 92% (44/48) of patients and in 95% (42/44) at one year. Eight (16%) showed some loss of reduction of the plateau. In seven of these the loss of reduction was slight (< 3 mm) and no action was taken. One patient with a deep infection had gross loss of reduction and a poor functional outcome. Calcium-phosphate cement is a useful alternative to bone grafting for the treatment of fractures of the tibial plateau


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 150 - 154
1 Jan 1994
Bilic R Zdravkovic V Boljevic Z

A computer-assisted method of preoperative planning was used to create virtual models of the deformed distal end of the radius after malunion of a fracture. By comparison with a similar model of the uninjured wrist, values were calculated for the angles and lengths to be corrected by osteotomy. Shifts of the distal fragment were analysed for 33 deformed wrists, 27 of which underwent corrective osteotomy and bone grafting. In more than half the cases there was dorsal or volar shift of 3 mm or more. The accuracy of the correction was measured by comparing the three-dimensional models before and after osteotomy with the model of the normal wrist. The volar and ulnar inclination angles of the articular surface of the radius and the radial length were regularly restored to normal


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1113 - 1116
1 Nov 2000
Keating JF Blachut PA O’Brien PJ Court-Brown CM

Reamed intramedullary nailing was carried out on 57 Gustilo grade-IIIB tibial fractures in 55 patients. After debridement, there was substantial bone loss in 28 fractures (49%). The mean time to union was 43 weeks (14 to 94). When there was no bone loss, the mean time to union was 32 weeks; it was 45 weeks if there was bone loss. Fractures complicated by infection took a mean of 53 weeks to heal. Revision nailing was necessary in 13 fractures (23%) and bone grafting in 15 (26%). In ten fractures (17.5%) infection developed, in four within six weeks of injury and in six more than four months later. Of these, nine were treated successfully, but one patient required an amputation because of osteomyelitis. Our results indicate that reamed intramedullary nailing is a satisfactory treatment for Gustilo grade-III tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 977 - 983
1 Sep 2000
Patel VR Menon DK Pool RD Simonis RB

We used the Ilizarov circular external fixator to treat 16 patients with persistent nonunion of the diaphysis of the humerus despite surgical treatment. All patients had pain and severe functional impairment of the affected arm. In ten, nonunion followed intramedullary nailing. We successfully treated these by a closed technique. The nail was left in place and the fracture compressed over it. The fractures of the other six patients had previously been fixed by various methods. We explored these nonunions, removed the fixation devices and excised fibrous tissue and dead bone before stabilising with the Ilizarov fixator. In five patients union was achieved. Bone grafting was not required. In the single patient in whom treatment failed, there had been a severely comminuted open fracture. All except one patient had reduction of pain, and all reported an improvement in function


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 374 - 378
1 May 1989
de Boer H Wood M

We report a retrospective review of 62 consecutive patients who had a vascularised fibular transfer to reconstruct a large skeletal defect. We were particularly interested in the bone dynamics of the vascularised graft, since fractures occurred in 25% of the cases at an average time of eight months after surgery. Hypertrophy was more common when the limb was mechanically loaded; it was enhanced where the graft was not bypassed by internal fixation. The length of the graft and the use of additional bone graft material had no influence on the incidence of stress fracture or on hypertrophy. We conclude that a vascularised graft should be protected against fatigue fracture during the first year, and that a gradual increase in mechanical loading will enhance remodelling and hypertrophy


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 561 - 564
1 Dec 1982
Hanai K Inouye Y Kawai K Tago K Itoh Y

In this series, 15 patients with ossification of the posterior longitudinal ligament underwent anterior decompression to relieve moderate or severe myelopathy, which in 11 included urinary disturbance. The operation consisted of partial resection of the vertebrae, release of the ossified plaque from the surrounding tissue and the insertion of an iliac bone graft. The extent of ossification was confirmed by computerised tomography before and after operation. The plaque was completely detached and moved forward in half of the patients, but only partially moved in the remainder. Symptoms improved considerably. Urinary disturbance disappeared in all patients, but sensory disturbance was left in most. Two patients had prolonged symptoms which were not relieved despite the complete release of the ossified defect


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 367 - 375
1 Aug 1981
Morrissy R Riseborough E Hall J

Forty cases of congenital pseudarthrosis of the tibia were reviewed. The results were assessed so as to emphasise function rather than simply the presence or absence of union. At the time of review, 14 patients had undergone amputation; eight others had non-union or tenuous union. No surgical procedure except the Farmer operation (a composite skin and bone pedicle graft from the other leg) showed any clear superiority. Among the factors associated with a poor result were considerable shortening, older children, and rapid resorption of the bone graft. It is felt that congenital pseudarthrosis of the tibia is a biological problem and not merely a mechanical one; consequently biological approaches to its treatment are needed


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1409 - 1415
1 Nov 2018
Marson BA Deshmukh SR Grindlay DJC Ollivere BJ Scammell BE

Aims

Local antibiotics are used in the surgical management of foot infection in diabetic patients. This systematic review analyzes the available evidence of the use of local antibiotic delivery systems as an adjunct to surgery.

Materials and Methods

Databases were searched to identify eligible studies and 13 were identified for inclusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 312 - 318
1 May 1973
Christensen NO

1. The Küntscher method of intramedullary reaming and nail fixation was applied to thirty-five cases of non-union of the lower extremity, twenty femurs and fifteen tibias. A bone graft was generally not used. 2. Most of the patients were allowed to bear weight and to exercise the joints within a few days of the operation. Additional measures such as pre-operative surgery for infection or distraction of shortening were used in some cases. 3. The pseudarthrosis healed in all cases, even when infection was present. The nails were generally not removed until after healing had occurred. 4. It is concluded that the Küntscher method gives remarkably rapid consolidation and restoration of function even in difficult cases of non-union of shaft fracture, particularly of the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 2 | Pages 286 - 291
1 May 1965
Fitzpatrick SC

1. A thirty-two-year-old man has been under treatment for twelve years for primary hydatid disease of the body of the third lumbar vertebra. 2. The second lumbar vertebra became involved, as were the soft tissues over a wide area, but the spinal canal was not affected. 3. A hydatid cyst was found in the left lung. 4. Management included stabilisation of the spine by bone graft, desensitisation to hydatid antigen, removal of the diseased vertebral bodies, pedicles and processes, the use of saturated solution of sodium chloride as a scolicide and the dilation of secondary ureteral strictures. 5. The patient, although not cured, has been enabled to "live with his disease" to earn his living and enjoy tennis and swimming