The outcome of total knee arthroplasty (TKA) is not always satisfactory.
The purpose of this study was to identify satisfaction and biomechanical
features characterising the gait of patients who had undergone TKA
with either an anatomical single radius design or a medial pivot
design. We hypothesised that the latter would provide superior function. This is a study of a subset of patients recruited into a prospective
randomised study of a single radius design Aims
Patients and Methods
This study investigates the reporting of health-related quality of life (HRQoL) in patients following hip fracture. We compare the relative merits and make recommendations for the use for two methods of measuring HRQoL; (i) including patients who died during follow-up and (ii) including survivors only. The World Hip Trauma Evaluation has previously reported changes in HRQoL using EuroQol-5D for patients with hip fractures. We performed additional analysis to investigate the effect of including or excluding those patients who died during the first four months of the follow-up period.Objectives
Methods
The aim of this independent multicentre study was to assess the
mid-term results of mobile bearing unicondylar knee arthroplasty
(UKA) for isolated lateral osteoarthritis of the knee joint. We retrospectively evaluated 363 consecutive, lateral UKAs (346
patients) performed using the Oxford domed lateral prosthesis undertaken
in three high-volume knee arthroplasty centres between 2006 and
2014. Mean age of the patients at surgery was 65 years (36 to 88)
with a mean final follow-up of 37 months (12 to 93)Aims
Patients and Methods
To compare the early management and mortality of older patients
sustaining major orthopaedic trauma with that of a younger population
with similar injuries. The Trauma Audit Research Network database was reviewed to identify
eligible patients admitted between April 2012 and June 2015. Distribution
and severity of injury, interventions, comorbidity, critical care
episodes and mortality were recorded. The population was divided
into young (64 years or younger) and older (65 years and older) patients.Aims
Patients and Methods
Fracture clinics are often characterised by the referral of large
numbers of unselected patients with minor injuries not requiring
investigation or intervention, long waiting times and recurrent
unnecessary reviews. Our experience had been of an unsustainable
system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order
to rationalise and regulate access to our fracture service. The
British Orthopaedic Association’s guidelines have required a prospective evaluation
of this change of practice, and we report our experience and results. We review the management of all 12 069 patients referred to our
service in the calendar year 2014, with a minimum of one year follow-up
during the calendar year 2015. Aims
Patients and Methods
The aim of this study was to determine whether patients with
metal-on-metal (MoM) arthroplasties of the hip have an increased
risk of cardiac failure compared with those with alternative types
of arthroplasties (non-MoM). A linkage study between the National Joint Registry, Hospital
Episodes Statistics and records of the Office for National Statistics
on deaths was undertaken. Patients who underwent elective total
hip arthroplasty between January 2003 and December 2014 with no
past history of cardiac failure were included and stratified as
having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty.
The primary outcome measure was the time to an admission to hospital
for cardiac failure or death. Analysis was carried out using data
from all patients and from those matched by propensity score.Aims
Patients and Methods
The aim of this study was to determine whether the rates of revision
for metal-on-metal (MoM) total hip arthroplasties (THAs) with Pinnacle
components varied according to the year of the initial operation,
and compare these with the rates of revision for other designs of
MoM THA. Data from the National Joint Registry for England and Wales included
36 mm MoM THAs with Pinnacle acetabular components which were undertaken
between 2003 and 2012 with follow-up for at least five years (n
= 10 776) and a control group of other MoM THAs (n = 13 817). The
effect of the year of the primary operation on all-cause rates of revision
was assessed using Cox regression and interrupted time-series analysis.Aims
Patients and Methods
A clicky hip is a common referral for clinical and sonographic
screening for developmental dysplasia of the hip (DDH). There is
controversy regarding whether it represents a true risk factor for
pathological DDH. Therefore a 20-year prospective, longitudinal,
observational study was undertaken to assess the relationship between
the presence of a neonatal clicky hip and pathological DDH. A total of 362 infants from 1997 to 2016 were referred with clicky
hips to our ‘one-stop’ paediatric hip screening clinic. Hips were
assessed clinically for instability and by ultrasound imaging using
a simplified Graf/Harcke classification. Dislocated or dislocatable
hips were classified as Graf Type IV hips.Aims
Patients and Methods
The number of patients undergoing arthroscopic surgery of the
hip has increased significantly during the past decade. It has now
become an established technique for the treatment of many intra-
and extra-articular conditions affecting the hip. However, it has
a steep learning curve and is not without the risk of complications.
The purpose of this systematic review was to determine the prevalence
of complications during and following this procedure. Preferred Reporting Items for Systematic Reviews and Meta-Analyses
guidelines were used in designing this study. Two reviewers systematically
searched the literature for complications related to arthroscopy
of the hip. The research question and eligibility criteria were
established Aims
Materials and Methods
A fracture of the hip is the most common serious orthopaedic
injury, and surgical site infection (SSI) is one of the most significant
complications, resulting in increased mortality, prolonged hospital
stay and often the need for further surgery. Our aim was to determine
whether high dose dual antibiotic impregnated bone cement decreases the
rate of infection. A quasi-randomised study of 848 patients with an intracapsular
fracture of the hip was conducted in one large teaching hospital
on two sites. All were treated with a hemiarthroplasty. A total
of 448 patients received low dose single-antibiotic impregnated
cement (control group) and 400 patients received high dose dual-antibiotic impregnated
cement (intervention group). The primary outcome measure was deep
SSI at one year after surgery.Aims
Patients and Methods
Anatomical total knee arthroplasty alignment
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
The National Institute for Health and Care Excellence
has issued guidelines that state fusion for non-specific low back
pain should only be performed as part of a randomised controlled
trial, and that lumbar disc replacement should not be performed.
Thus, spinal fusion and disc replacement will no longer be routine
forms of treatment for patients with low back pain. This annotation
considers the evidence upon which these guidelines are based. Cite this article:
The primary aim of this independent prospective randomised trial
was to compare serum metal ion levels for ceramic-on-metal (CoM)
and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty
(THA). Our one-year results demonstrated elevation in metal ion
levels above baseline with no significant difference between the
CoM and MoM groups. This paper reviews the five-year data. The implants used in each patient differed only in respect to
the type of femoral head (ceramic or metal). At five-year follow-up
of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available
for comparison.Aims
Patients and Methods
Total knee arthroplasty (TKA) is a cost effective
and extremely successful operation. As longevity increases, the demand
for primary TKA will continue to rise. The success and survivorship
of TKAs are dependent on the demographics of the patient, surgical
technique and implant-related factors. Currently the risk of failure of a TKA requiring revision surgery
ten years post-operatively is 5%. The most common indications for revision include aseptic loosening
(29.8%), infection (14.8%), and pain (9.5%). Revision surgery poses
considerable clinical burdens on patients and financial burdens
on healthcare systems. We present a current concepts review on the epidemiology of failed
TKAs using data from worldwide National Joint Registries. Cite this article:
The optimal method of tibial component fixation remains uncertain
in total knee arthroplasty (TKA). Hydroxyapatite coatings have been
applied to improve bone ingrowth in uncemented designs, but may
only coat the directly accessible surface. As peri-apatite (PA)
is solution deposited, this may increase the coverage of the implant
surface and thereby fixation. We assessed the tibial component fixation
of uncemented PA-coated TKAs Patients were randomised to PA-coated or cemented TKAs. In 60
patients (30 in each group), radiostereometric analysis of tibial
component migration was evaluated as the primary outcome at baseline,
three months post-operatively and at one, two and five years. A
linear mixed-effects model was used to analyse the repeated measurements.Aims
Patients and Methods