Adolescent idiopathic scoliosis affects about
3% of children. Non-operative measures are aimed at altering the natural
history to maintain the size of the curve below 40° at skeletal
maturity. The application of braces to treat spinal deformity pre-dates
the era of evidence-based medicine, and there is a paucity of irrefutable
prospective evidence in the literature to support their use and
their effectiveness has been questioned. This review considers this evidence. The weight of the evidence
is in favour of bracing over observation. The most recent literature
has moved away from addressing this question, and instead focuses
on developments in the design of braces and ways to improve compliance. Cite this article:
The period of post-operative treatment before surgical wounds
are completely closed remains a key window, during which one can
apply new technologies that can minimise complications. One such
technology is the use of negative pressure wound therapy to manage
and accelerate healing of the closed incisional wound (incisional
NPWT). We undertook a literature review of this emerging indication
to identify evidence within orthopaedic surgery and other surgical
disciplines. Literature that supports our current understanding
of the mechanisms of action was also reviewed in detail. Objectives
Methods
We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone >
2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped. Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease.
The April 2013 Oncology Roundup360 looks at: the margin for error; new money for old risks; hindquarter amputation; custom tumour jigs; preserving the tibial epiphysis; how long is long enough?; genomics and radiation-induced bone tumours; and India ink.
As many as 25% to 40% of unicompartmental knee
replacement (UKR) revisions are performed for pain, a possible cause
of which is proximal tibial strain. The aim of this study was to
examine the effect of UKR implant design and material on cortical
and cancellous proximal tibial strain in a synthetic bone model.
Composite Sawbone tibiae were implanted with cemented UKR components
of different designs, either all-polyethylene or metal-backed. The tibiae
were subsequently loaded in 500 N increments to 2500 N, unloading
between increments. Cortical surface strain was measured using a
digital image correlation technique. Cancellous damage was measured
using acoustic emission, an engineering technique that detects sonic
waves (‘hits’) produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences
between implants at 1500 N and 2500 N in the proximal 10 mm only
(p <
0.001), with relative strain shielding in metal-backed implants.
Acoustic emission showed significant differences in cancellous bone
damage between implants at all loads (p = 0.001). All-polyethylene implants
displayed 16.6 times the total number of cumulative acoustic emission
hits as controls. All-polyethylene implants also displayed more
hits than controls at all loads (p <
0.001), more than metal-backed
implants at loads ≥ 1500 N (p <
0.001), and greater acoustic
emission activity on unloading than controls (p = 0.01), reflecting
a lack of implant stiffness. All-polyethylene implants were associated
with a significant increase in damage at the microscopic level compared
with metal-backed implants, even at low loads. All-polyethylene
implants should be used with caution in patients who are likely
to impose large loads across their knee joint. Cite this article:
The aim of our study was to investigate whether placing of the femoral component of a hip resurfacing in valgus protected against spontaneous fracture of the femoral neck. We performed a hip resurfacing in 20 pairs of embalmed femora. The femoral component was implanted at the natural neck-shaft angle in the left femur and with a 10° valgus angle on the right. The bone mineral density of each femur was measured and CT was performed. Each femur was evaluated in a materials testing machine using increasing cyclical loads. In specimens with good bone quality, the 10° valgus placement of the femoral component had a protective effect against fractures of the femoral neck. An adverse effect was detected in osteoporotic specimens. When resurfacing the hip a valgus position of the femoral component should be achieved in order to prevent fracture of the femoral neck. Patient selection remains absolutely imperative. In borderline cases, measurement of bone mineral density may be indicated.
Our understanding of the origin of hip pain in
degenerative disorders of the hip, including primary osteoarthritis, avascular
necrosis and femoroacetabular impingement (FAI), is limited. We
undertook a histological investigation of the nociceptive innervation
of the acetabular labrum, ligamentum teres and capsule of the hip,
in order to prove pain- and proprioceptive-associated marker expression.
These structures were isolated from 57 patients who had undergone
elective hip surgery (44 labral samples, 33 ligamentum teres specimens,
34 capsular samples; in 19 patients all three structures were harvested).
A total of
15 000 histological sections were prepared that were investigated
immunohistochemically for the presence of protein S-100, 68 kDa
neurofilament, neuropeptide Y, nociceptin and substance P. The tissues
were evaluated in six representative areas. Within the labrum, pain-associated free nerve ending expression
was located predominantly at its base, decreasing in the periphery.
In contrast, the distribution within the ligamentum teres showed
a high local concentration in the centre. The hip capsule had an
almost homogeneous marker expression in all investigated areas. This study showed characteristic distribution profiles of nociceptive
and pain-related nerve fibres, which may help in understanding the
origin of hip pain. Cite this article:
We conducted a randomised controlled trial to
determine whether active intense pulsed light (IPL) is an effective treatment
for patients with chronic mid-body Achilles tendinopathy. A total
of 47 patients were randomly assigned to three weekly therapeutic
or placebo IPL treatments. The primary outcome measure was the Victorian
Institute of Sport Assessment – Achilles (VISA-A) score. Secondary
outcomes were a visual analogue scale for pain (VAS) and the Lower
Extremity Functional Scale (LEFS). Outcomes were recorded at baseline,
six weeks and 12 weeks following treatment. Ultrasound assessment
of the thickness of the tendon and neovascularisation were also
recorded before and after treatment. There was no significant difference between the groups for any
of the outcome scores or ultrasound measurements by 12 weeks, showing
no measurable benefit from treatment with IPL in patients with Achilles tendinopathy. Cite this article:
We investigated whether an asymmetric extension
gap seen on routine post-operative radiographs after primary total
knee replacement (TKR) is associated with pain at three, six, 12
and 24 months’ follow-up. On radiographs of 277 patients after primary
TKR we measured the distance between the tibial tray and the femoral
condyle on both the medial and lateral sides. A difference was defined
as an asymmetric extension gap. We considered three groups (no asymmetric
gap, medial-opening and lateral-opening gap) and calculated the
associations with the Western Ontario and McMaster Universities
osteoarthritis index pain scores over time. Those with an asymmetric extension gap of ≥ 1.5 mm had a significant
association with pain scores at three months’ follow-up; patients
with a medial-opening extension gap reported more pain and patients
with a lateral-opening extension gap reported less pain (p = 0.036).
This effect was still significant at six months (p = 0.044), but had
lost significance by 12 months (p = 0.924). When adjusting for multiple
cofounders the improvement in pain was more pronounced in patients
with a lateral-opening extension gap than in those with a medial-opening extension
gap at three (p = 0.037) and six months’ (p = 0.027) follow-up. Cite this article:
The December 2012 Spine Roundup360 looks at: the Japanese neck disability index; adjacent segment degeneration; sacroiliac loads determined by limb length discrepancy; whether epidural steroids improve outcome in lumbar disc herniation; spondylodiscitis in infancy; total pedicle screws; and iliac crest autograft complications.
Intra-operative, peri-articular injection of
local anaesthesia is an increasingly popular way of controlling
pain following total knee replacement. The evidence from this study suggests that it is safe to use
peri-articular injection in combination with auto-transfusion of
blood from peri-articular drains during knee replacement surgery.
Reverse total shoulder replacement (RTSR) depends
on adequate deltoid function for a successful outcome. However, the
anterior deltoid and/or axillary nerve may be damaged due to prior
procedures or injury. The purpose of this study was to determine
the compensatory muscle forces required for scapular plane elevation
following RTSR when the anterior deltoid is deficient. The soft
tissues were removed from six cadaver shoulders, except for tendon
attachments. After implantation of the RTSR, the shoulders were
mounted on a custom-made shoulder simulator to determine the mean
force in each muscle required to achieve 30° and 60° of scapular
plane elevation. Two conditions were tested: 1) Control with an
absent supraspinatus and infraspinatus; and 2) Control with anterior
deltoid deficiency. Anterior deltoid deficiency resulted in a mean
increase of 195% in subscapularis force at 30° when compared with
the control (p = 0.02). At 60°, the subscapularis force increased
a mean of 82% (p <
0.001) and the middle deltoid force increased
a mean of 26% (p = 0.04). Scapular plane elevation may still be possible following an RTSR
in the setting of anterior deltoid deficiency. When the anterior
deltoid is deficient, there is a compensatory increase in the force
required by the subscapularis and middle deltoid. Attempts to preserve
the subscapularis, if present, might maximise post-operative function.
The February 2013 Knee Roundup360 looks at: mobile-bearing TKRs; arthroscopic ACL reconstruction; the use of chondrocytes for osteochondral defects; ACL reconstruction and the return to pivoting sports; ACLs and the MOON study; the benefit of knee navigation; and trabecular metal.
We analysed retrospectively the risk factors
leading to femoral overgrowth after flexible intramedullary nailing
in 43 children (mean age 7.1 years (3.6 to 12.0)) with fractures
of the shaft of the femur. We reviewed their demographic data, mechanism
of injury, associated injuries, the type and location of the fractures,
the nail–canal diameter (NCD) ratios and femoral overgrowth at a
mean follow-up of 40.7 months (25.2 to 92.7). At that time, the
children were divided into two groups, those with femoral overgrowth
of <
1 cm (Group 1), and those with overgrowth of ≥ 1 cm (Group
2). The mean femoral overgrowth of all patients was 0.6 cm at final
follow-up. Overgrowth of ≥ 1 cm was noted in 11 children (25.6%).
The NCD ratio was significantly lower in Group 2 than in Group 1,
with an odds ratio of 30.0 (p = 0.003). We believe that a low NCD ratio is an indicator of an unstable
configuration with flexible intramedullary nailing, and have identified
an association between a low NCD ratio and femoral overgrowth resulting
in leg-length discrepancy after flexible intramedullary nailing
in paediatric femoral shaft fractures. Cite this article:
This study provides recommendations on the position
of the implant in reverse shoulder replacement in order to minimise
scapular notching and osteophyte formation. Radiographs from 151
patients who underwent primary reverse shoulder replacement with
a single prosthesis were analysed at a mean follow-up of 28.3 months
(24 to 44) for notching, osteophytes, the position of the glenoid
baseplate, the overhang of the glenosphere, and the prosthesis scapular
neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four
Grade 2) and 47 (31.1%) had an osteophyte. In patients without either
notching or an osteophyte the baseplate was found to be positioned
lower on the glenoid, with greater overhang of the glenosphere and
a lower PSNA than those with notching and an osteophyte. Female patients
had a higher rate of notching than males (13.3% Based on these findings we make recommendations on the placement
of the implant in both male and female patients to avoid notching
and osteophyte formation. Cite this article:
We have compared four computer-assisted methods to measure penetration of the femoral head into the acetabular component in total hip replacement. These were the Martell Hip Analysis suite 7.14, Rogan HyperOrtho, Rogan View Pro-X and Roman v1.70. The images used for the investigation comprised 24 anteroposterior digital radiographs and 24 conventional acetate radiographs which were scanned to provide digital images. These radiographs were acquired from 24 patients with an uncemented total hip replacement with a follow-up of approximately eight years (mean 8.1; 6.3 to 9.1). Each image was measured twice by two blinded observers. The mean annual rates of penetration of the femoral head measured in the eight-year single image analysis were: Martell, 0.24 (SD 0.19); HyperOrtho, 0.12 (SD 0.08); View Pro-X, 0.12 (SD 0.06); Roman, 0.12 (SD 0.07). In paired analysis of the six-month and eight-year radiographs: Martell, 0.35 (SD 0.22); HyperOrtho, 0.15 (SD 0.13); View Pro-X, 0.11 (SD 0.06); Roman, 0.11 (SD 0.07). The intra- and inter-observer variability for the paired analysis was best for View Pro-X and Roman software, with intraclass correlations of 0.97, 0.87 and 0.96, 0.87, respectively, and worst for HyperOrtho and Martell, with intraclass correlations of 0.46, 0.13 and 0.33, 0.39, respectively. The Roman method proved the most precise and the most easy to use in clinical practice and the software is available free of charge. The Martell method showed the lowest precision, indicating a problem with its edge detection algorithm on digital images.
Symptomatic cobalt toxicity from a failed total
hip replacement is a rare but devastating complication. It has been reported
following revision of fractured ceramic components, as well as in
patients with failed metal-on-metal articulations. Potential clinical
findings include fatigue, weakness, hypothyroidism, cardiomyopathy,
polycythaemia, visual and hearing impairment, cognitive dysfunction,
and neuropathy. We report a case of an otherwise healthy 46-year-old
patient, who developed progressively worsening symptoms of cobalt
toxicity beginning approximately six months following synovectomy
and revision of a fractured ceramic-on-ceramic total hip replacement
to a metal-on-polyethylene bearing. The whole blood cobalt levels
peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy.
Implant retrieval analysis confirmed a loss of 28.3 g mass of the
cobalt–chromium femoral head as a result of severe abrasive wear
by ceramic particles embedded in the revision polyethylene liner.
Autopsy findings were consistent with heavy metal-induced cardiomyopathy. We recommend using new ceramics at revision to minimise the risk
of wear-related cobalt toxicity following breakage of ceramic components. Cite this article: