Advertisement for orthosearch.org.uk
Results 501 - 520 of 1344
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 107 - 115
1 Jun 2020
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP

Aims

Metaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system.

Methods

We reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m2 (18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6).


Bone & Joint 360
Vol. 9, Issue 1 | Pages 35 - 39
1 Feb 2020


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims

A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation.

Methods

This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 699 - 708
1 Jun 2020
Nieuwenhuijse MJ Vehmeijer SBW Mathijsen NMC Keizer SB

Aims

Short, bone-conserving femoral components are increasingly used in total hip arthroplasty (THA). They are expected to allow tissue-conserving implantation and to render future revision surgery more straightforward but the long-term data on such components is limited. One such component is the global tissue-sparing (GTS) stem. Following the model for stepwise introduction of new orthopaedic implants, we evaluated early implant fixation and clinical outcome of this novel short-stem THA and compared it to that of a component with established good long-term clinical outcome.

Methods

In total, 50 consecutive patients ≤ 70 years old with end-stage symptomatic osteo-arthritis were randomized to receive THA with the GTS stem or the conventional Taperloc stem using the anterior supine intermuscular approach by two experienced hip surgeons in two hospitals in the Netherlands. Primary outcome was implant migration. Patients were followed using routine clinical examination, patient reported outcome using Harris Hip Score (HHS), Hip Disability And Osteoarthritis Outcome Score (HOOS), EuroQol five-dimension questionnaire (EQ5D), and Roentgen Stereophotogrammetric Analysis (RSA) at three, six, 12, and 24 months. This study evaluated the two-year follow-up results.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 322 - 332
1 Jun 2020
Zhao H Yeersheng R Kang X Xia Y Kang P Wang W

Aims

The aim of this study was to examine whether tourniquet use can improve perioperative blood loss, early function recovery, and pain after primary total knee arthroplasty (TKA) in the setting of multiple-dose intravenous tranexamic acid.

Methods

This was a prospective, randomized clinical trial including 180 patients undergoing TKA with multiple doses of intravenous tranexamic acid. One group was treated with a tourniquet during the entire procedure, the second group received a tourniquet during cementing, and the third group did not receive a tourniquet. All patients received the same protocol of intravenous tranexamic acid (20 mg/kg) before skin incision, and three and six hours later (10 mg/kg). The primary outcome measure was perioperative blood loss. Secondary outcome measures were creatine kinase (CK), CRP, interleukin-6 (IL-6), visual analogue scale (VAS) pain score, limb swelling ratio, quadriceps strength, straight leg raising, range of motion (ROM), American Knee Society Score (KSS), and adverse events.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 606 - 610
1 May 2020
Nicholson JA Slader B Martindale A Mckie S Robinson CM

Aims

The primary aim of this study was to evaluate the efficacy of distension arthrography in the treatment of adhesive capsulitis of the shoulder. The secondary aim was to assess which patient and procedural factors predicted the recurrence of symptoms after the procedure.

Methods

All patients referred to our shoulder clinic over a ten-year period, between 2008 and 2018, with a clinical diagnosis of capsulitis and symptoms persisting for more than six months, were offered treatment with a distension arthrogram. All procedures were performed by one of five musculoskeletal radiologists, with a combination of steroid, local anaesthetic, and a distention volume of 10 ml, 30 ml, or 50 ml. Patient demographics, procedural details, recurrence of symptoms, and the need for further intervention were evaluated.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 212 - 219
1 Feb 2020
Ræder BW Figved W Madsen JE Frihagen F Jacobsen SB Andersen MR

Aims

In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years.

Methods

A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 550 - 555
1 May 2020
Birch N Todd NV

The cost of clinical negligence in the UK has continued to rise despite no increase in claims numbers from 2016 to 2019. In the US, medical malpractice claim rates have fallen each year since 2001 and the payout rate has stabilized. In Germany, malpractice claim rates for spinal surgery fell yearly from 2012 to 2017, despite the number of spinal operations increasing. In Australia, public healthcare claim rates were largely static from 2008 to 2013, but private claims rose marginally. The cost of claims rose during the period. UK and Australian trends are therefore out of alignment with other international comparisons. Many of the claims in orthopaedics occur as a result of “failure to warn”, i.e. lack of adequately documented and appropriate consent. The UK and USA have similar rates (26% and 24% respectively), but in Germany the rate is 14% and in Australia only 2%. This paper considers the drivers for the increased cost of clinical negligence claims in the UK compared to the USA, Germany and Australia, from a spinal and orthopaedic point of view, with a focus on “failure to warn” and lack of compliance with the principles established in February 2015 in the Supreme Court in the case of Montgomery v Lanarkshire Health Board. The article provides a description of the prevailing medicolegal situation in the UK and also calculates, from publicly available data, the cost to the public purse of the failure to comply with the principles established. It shows that compliance with the Montgomery principles would have an immediate and lasting positive impact on the sums paid by NHS Resolution to settle negligence cases in a way that has already been established in the USA.

Cite this article: Bone Joint J 2020;102-B(5):550–555.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 458 - 462
1 Apr 2020
Limberg AK Tibbo ME Pagnano MW Perry KI Hanssen AD Abdel MP

Aims

Varus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs.

Methods

A total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10).


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 310 - 314
1 Aug 1978
Shaw N Chatterjee R

The results of fifty-one Manchester knee arthroplasties in forty-one patients are reviewed and discussed. Excellent and good results were obtained in 85.4 per cent of arthroplasties. Varus and valgus deformity can be corrected and stability preserved or restored. Complications occurred in only twelve patients but resolved in all except one


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 867 - 874
1 Jun 2010
Hanna SA Sewell MD Aston WJS Pollock RC Skinner JA Cannon SR Briggs TWR

Segmental resection of malignant bone disease in the femoral diaphysis with subsequent limb reconstruction is a major undertaking. This is a retrospective review of 23 patients who had undergone limb salvage by endoprosthetic replacement of the femoral diaphysis for a primary bone tumour between 1989 and 2005. There were 16 males and seven females, with a mean age of 41.3 years (10 to 68). The mean overall follow-up was for 97 months (3 to 240), and 120 months (42 to 240) for the living patients. The cumulative patient survival was 77% (95% confidence interval 63% to 95%) at ten years. Survival of the implant, with failure of the endoprosthesis as an endpoint, was 85% at five years and 68% (95% confidence interval 42% to 92%) at ten years. The revision rate was 22% and the overall rate of re-operation was 26%. Complications included deep infection (4%), breakage of the prosthesis (8%), periprosthetic fracture (4%), aseptic loosening (4%), local recurrence (4%) and metastases (17%). The 16 patients who retained their diaphyseal endoprosthesis had a mean Musculoskeletal Tumour Society score of 87% (67% to 93%). They were all able to comfortably perform most activities of daily living. Femoral diaphyseal endoprosthetic replacement is a viable option for reconstruction following segmental resection of malignant bone disease. It allows immediate weight-bearing, is associated with a good long-term functional outcome, has an acceptable complication and revision rate and, most importantly, does not appear to compromise patient survival


Bone & Joint 360
Vol. 9, Issue 2 | Pages 19 - 23
1 Apr 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1617 - 1621
1 Dec 2005
O’Shea K Quinlan JF Kutty S Mulcahy D Brady OH

We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with femoral revision using an uncemented extensively porous-coated implant. A retrospective clinical and radiographic assessment of 22 patients with a mean follow-up of 33.7 months was performed. The mean time from the index procedure to fracture was 10.8 years. There were 17 patients with a satisfactory result. Complications in four patients included subsidence in two, deep sepsis in one, and delayed union in one. Concomitant acetabular revision was required in 19 patients. Uncemented extensively porous-coated femoral stems incorporate distally allowing stable fixation. We found good early survival rates and a low incidence of nonunion using this implant


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 82 - 89
1 Jan 2020
Coenders MJ Mathijssen NMC Vehmeijer SBW

Aims

The aim of this study was to report our experience at 3.5 years with outpatient total hip arthroplasty (THA).

Methods

In this prospective cohort study, we included all patients who were planned to receive primary THA through the anterior approach between 1 April 2014 and 1 October 2017. Patient-related data and surgical information were recorded. Patient reported outcome measures (PROMs) related to the hip and an anchor question were taken preoperatively, at six weeks, three months, and one year after surgery. All complications, readmissions, and reoperations were registered.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 890 - 892
1 Sep 1999
Rickman M Saleh M Gaines PA Eyres K

Osteotomies are commonly carried out in orthopaedic surgery, particularly in limb reconstruction. Complications are uncommon provided that sufficient care is taken and a sound technique used. We describe three cases of formation of false aneurysm after osteotomy, with acute, delayed and asymptomatic onset. The diagnosis was supported by ultrasound investigation, and confirmed by angiography. Embolisation with coils was a successful method of treatment. We recommend a safe method of osteotomy with good bone exposure and adequate soft-tissue protection


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 506 - 512
1 Apr 2020
de Bodman C Ansorge A Tabard A Amirghasemi N Dayer R

Aims

The direct posterior approach with subperiosteal dissection of the paraspinal muscles from the vertebrae is considered to be the standard approach for the surgical treatment of adolescent idiopathic scoliosis (AIS). We investigated whether or not a minimally-invasive surgery (MIS) technique could offer improved results.

Methods

Consecutive AIS patients treated with an MIS technique at two tertiary centres from June 2013 to March 2016 were retrospectively included. Preoperative patient deformity characteristics, perioperative parameters, power of deformity correction, and complications were studied. A total of 93 patients were included. The outcome of the first 25 patients and the latter 68 were compared as part of our safety analysis to examine the effect of the learning curve.


Bone & Joint Open
Vol. 1, Issue 3 | Pages 29 - 34
13 Mar 2020
Stirling P Middleton SD Brenkel IJ Walmsley PJ

Introduction

The primary aim of this study was to describe a baseline comparison of early knee-specific functional outcomes following revision total knee arthroplasty (TKA) using metaphyseal sleeves with a matched cohort of patients undergoing primary TKA. The secondary aim was to compare incidence of complications and length of stay (LOS) between the two groups.

Methods

Patients undergoing revision TKA for all diagnoses between 2009 and 2016 had patient-reported outcome measures (PROMs) collected prospectively. PROMs consisted of the American Knee Society Score (AKSS) and Short-Form 12 (SF-12). The study cohort was identified retrospectively and demographics were collected. The cohort was matched to a control group of patients undergoing primary TKA.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1178 - 1182
1 Sep 2006
Stanley JK Penn DS Wasseem M

Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human cadavers. An osteotomy of the supinator tuberosity was performed and reflected as a single unit with the attached annular ligament. Excellent exposure of the head of the radius was achieved, replacement of the head was undertaken and the osteotomy site repaired. The elbows were stable and had a full range of movement. The approach was then carried out on 13 patients for elective replacement of the head and was found to be safe and reproducible. In the patient group all osteotomies united, the elbows were stable and had an improved range of supination and pronation. There was no change in flexion and extension of the elbow. Complications included a haematoma and a reflex sympathetic dystrophy. The modified posterior approach provides excellent access to the head and neck of the radius, gives good stability of the elbow and allows early mobilisation of the joint


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 650 - 652
1 Jul 1993
Birch N Sly C Brooks S Powles D

We report a prospective, randomised, controlled trial of the effect of either a non-steroidal anti-inflammatory drug (diclofenac sodium) or physiotherapy on the recovery of knee function after arthroscopy. At 42 days after surgery there was no significant benefit from either form of postoperative treatment compared with the control group. Complications attributable to the anti-inflammatory drug occurred in 9.6% of the patients so treated. Neither the routine administration of a non-steroidal anti-inflammatory agent nor routine physiotherapy is justified after arthroscopy of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 1 | Pages 74 - 83
1 Feb 1950
Murray RC Forrai E

1. Study of 200 cases investigated by pneumarthrography has shown that the introduction of air or oxygen into the knee joint is followed by a specific reaction characterised by transient localised eosinophilia in synovial membrane and synovial fluid. 2. Complications after meniscectomy seem to be more frequent when operation is performed during the phase of eosinophil reaction. 3. The significance of these observations has been discussed in relation to other causes ofeosinophilia and it is suggested that this method of local production of eosinophils may be of experimental importance